Altronix NetWay5BTQ Series Hardened Outdoor 802.3bt 4PPoE Switch Installation Guide
- July 25, 2024
- Altronix
Table of Contents
- Altronix NetWay5BTQ Series Hardened Outdoor 802.3bt 4PPoE Switch
- Product Usage Instructions
- FAQ
- Models Include
- Overview
- Features
- Installation Instructions
- Technical Specifications
- Typical Application
- Configuring NetWay5BTQ for Network Connection
- VLans
- Typical VLan Setup
- NetWay5BTQPL
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Altronix NetWay5BTQ Series Hardened Outdoor 802.3bt 4PPoE Switch
Specifications
- Model: NetWay5BTQ Series
- Number of Ports: 5
- Power Supply: 48-56V UL Listed ITE power supply
- Power per Port: 90W
- Total Power: 240W
Product Usage Instructions
Overview
The Altronix NetWay5BTQ Series are LINQ Managed Hardened 802.3bt 4PPoE Switches designed to provide network data uplink and power to IP devices such as access controllers and cameras.
Features
- Auto-negotiation
- LEDs for each port
- Networking of multiple remote devices without running multiple cables
Installation Instructions
NetWay5BTQ/NetWay5BTQPL
- Mount the board/backplane in the desired location/enclosure using the included hardware.
- Connect NetWay5BTQ to a power source and Ethernet devices:
- Power NetWay5BTQ using a 48-56V ITE power supply like Altronix PoE240 or PoE360.
- Connect the power source to the [GND +56V] terminals and the Data source to the [Data Input] RJ45 jack.
- Connect Access Control boards, Altronix LINQ units, or other IP devices to the [Port 1 – Port 4] RJ45 jacks.
NetWay5BTQWPN/NetWay5BTQWP/NetWay5BTQWPX
- Remove the backplane from the enclosure before drilling. Ensure hardware will not interfere with circuit board components.
- Mark and drill desired inlets on the enclosure for wiring. Use NEMA-type 4X-rated fittings for the enclosure flange.
- Secure the enclosure with appropriate fasteners compatible with the mounting surface.
- Pole Mount: Refer to detailed instructions in the manual.
FAQ
Q: Can the NetWay5BTQ Series switches be powered by any power supply?
A: No, the switches should be powered by a 48-56V UL-listed ITE power supply like Altronix PoE240 or PoE360 for proper functionality.
Q: What is the maximum power output per port of the NetWay5BTQ Series?
A: Each port can deliver up to 90W, with a total power output of 240W across all ports.
NetWay5BTQ Series
LINQ Managed Hardened 802.3bt 4PPoE Switches
Models Include
NetWay5BTQWP
-
* 5-port Managed Hardened 802.3bt 4PPoE
- Switch with Power Supply/Charger
- NEMA4/4X, IP66-rated Outdoor enclosure.
- NetWay5BTQWPX
- 5-port Managed Hardened 802.3bt 4PPoE
- Switch with Power Supply/Charger
- NEMA4/4X, IP66-rated Outdoor enclosure.
- Accommodates up to four (4)
- 12VDC/4AH batteries.
- NetWay5BTQWPN
- 5-port Managed Hardened 802.3bt 4PPoE Switch
- NEMA4/4X rated outdoor enclosure
- NetWay5BTQX
- 5-port Managed Hardened 802.3bt 4PPoE
- Switch with Power Supply/Charger
- NEMA1-rated Indoor enclosure.
- NetWay5BTQPL
- 5-port Managed Hardened PoE Switch with
- Power Supply/Charger
- Backplane version.
- NetWay5BTQ
- 5-port Managed Hardened
- 802.3bt 4PPoE Switch
- Board Only
Overview
- Altronix NetWay5BTQ Series are LINQ Managed by Hardened 802.3bt 4PPoE Switches. They provide a network data uplink and four (4) IEEE802.3af/3at/3bt PoE ports rated at 90W each, with 240W total power.
- They can power IP devices, such as PoE access controllers and cameras. Other applications may include integrating network door access systems with video surveillance.
For unmanaged switches see NetWay5BT Series
Features
Input:
-
* 115VAC, 60Hz, 1.8A or 230VAC, 50/60Hz, 1A.
- NetWay5BTQ/NetWay5BTQWPN:
- 48-56V UL Listed ITE power supply.
Output:
- Four (4) IEEE802.3af/3at/3bt PoE ports rated at 90W each.
- Single data uplink port.
Ethernet Ports:
- Five (5) 10/100/1000 Mbps ports.
- Connectivity: RJ45, auto-crossover.
- Wire type: 4-pair CAT5e or higher structured cable.
- Distance: up to 100m.
- Speed: 10/100/1000 Mbps, half/full duplex, auto negotiation.
LINQ Technology:
- Remote network management allows for camera/ device reset and monitoring.
- PoE port management via Dashboard IP management program.
- Provides local and/or remote access to critical information via LAN/WAN.
- Email and Windows Dashboard Alert notifications report real-time diagnostics.
- The event log tracks history.
LED Indicators:
- Individual PoE On LEDs for each port.
- Individual IP Link status, 100/1000Base-T/active LEDs for each port.
VLAN:
- Multiple management VLAN assignments.
- 802.1Q Tagged VLAN.
- Up to 10 VLAN groups. ID Range 2-4095.
- Applications:
- Allows to power up to four (4) IP devices and network multiple remote devices without the need for running multiple cables from the main switch/server.
Environmental:
- Operating Ambient Temperature:
- 30ºC to 70ºC (– 22ºF to 158ºF).
Storage Temperature:
- 0ºC to 85ºC (– 40ºF to 185ºF).
- Humidity: 20 to 85%, non-condensing.
- Operating Altitude: – 304.8 to 2,000m.
Mechanical:
NetWay5BTQ:
- Dimensions (L x W x D approx.):
- 5.9” x 3.6” x 0.75” (150mm x 91.4mm x 19mm).
NetWay5BTQWPN
- NEMA 4X, IP66-rated enclosure for outdoor use.
- Dimensions (H x W x D approx.): 9.5” x 7.32” x 4.92”
- (241.3mm x 185.9mm x 125mm).
NetWay5BTQWP:
- NEMA4/4X, IP66-rated enclosure for outdoor use.
- Dimensions (H x W x D approx.): 13.31” x 11.31” x 5.59”
- (338.1mm x 287.3mm x 142mm).
NetWay5BTQWPX:
- NEMA4/4X, IP66-rated enclosure for outdoor use.
- Accommodates sealed lead acid or gel type or LiFePO4 (Lithium Iron Phosphate) 12VDC batteries.
- Dimensions (H x W x D approx.): 17.53” x 15.3” x 6.67”
- (445.3mm x 388.6mm x 169.4mm).
NetWay5BTQPL
- Dimensions (H x W x D approx.): 10.75” x 8.875” x 2.375”
- (273.1mm x 225.4mm x 60.3mm).
NetWay5BTQX:
- Dimensions (H x W x D approx.): 13.5” x 13” x 3.25” (342.9mm x 330.2mm x 83mm).
Installation Instructions
Wiring methods shall be by the National Electrical Code/NFPA 70/ANSI, and with
all local codes and authorities having jurisdiction. Wiring should be UL-
listed and/or Recognized wire suitable for the application.
All units should be installed by trained service personnel.
Installation NetWay5BTQ/NetWay5BTQPL:
- Mount board/backplane in the desired location/enclosure (mounting hardware included).
- NetWay5BTQ: Connect NetWay5BTQ to a power source and Ethernet devices: NetWay5BTQ can be powered by a 48-56V ITE power supply, e.g. Altronix PoE240 or PoE360 power supply/charger.
- Connect a power source to the [GND +56V] terminals carefully observing polarity (Fig. 1a).
- Connect a Data source to the [Data Input] RJ45 jack (Fig. 1b).
- Connect Access Control boards, Altronix LINQ units, or other IP devices to the [Port 1 – Port 4] RJ45 jacks (Fig. 1c). Refer to the corresponding Installation Guides for details.
NetWay5BTQWPN/NetWay5BTQWP/NetWay5BTQWPX:
- Remove the backplane from the enclosure before drilling. Do not discard hardware.
- Note: Make sure that hardware will not interfere with the components of the circuit board.
- Mark and drill desired inlets on the enclosure to facilitate wiring. Maximum NEMA type 4X rated fittings to be used are 0.5”. Follow the manufacturer’s specifications for the appropriate size opening.
- Note: Inlets for conduit fittings should only be made on the bottom of the enclosure.
- To facilitate wire entry utilize weather-tight NEMA-rated connectors (supplied), bushings, and cable.
- Clean out the inside of the enclosure before remounting circuit boards/backplanes.
- Mounting NEMA4/4X rated enclosure (Enclosure Dimensions):
- Wall mount: Mount the unit in the desired location. Mark and drill holes to line up with the top and bottom holes of the enclosure flange. Secure the enclosure with appropriate fasteners (e. g. screws and anchors; bolts and locking nuts, etc.) that are compatible with the mounting surface and are of sufficient length/construction to ensure a secure mount (Fig. 5).
- Pole Moun t: Refer to Fig. 6 – 11,
- Mount the backplane in an enclosure with hardware.
NetWay5BTQX:
- Mount the unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure. Install two (2) upper fasteners and screws in the wall with the screw heads protruding.
- Place the enclosure’s upper keyholes over the two (2) upper screws; level and secure. Mark the position of the lower two (2) holes. Remove the enclosure. Drill the lower holes and install two fasteners.
- Place the enclosure’s upper keyholes over the two (2) upper screws. Install the two (2) lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 16). Secure the enclosure to earth ground.
Power Connection
NetWay5BTQWP, NetWay5BTQWPX, NetWay5BTQX:
- Secure cabinet to earth ground. Connect AC power from the overcurrent protective device circuit breaker (20A @ 115VAC, 60Hz, 16A @ 230VAC, 50/60Hz) to the terminals marked [L, N] on the power supply board.
- Use 14AWG or larger for all power connections (Battery, DC output, AC input).
- Connect ground lug to earth or green branch wire (12AWG min.).
- Keep power-limited wiring separate from non-power-limited wiring (120VAC 60Hz Input, Battery Wires). A minimum 0.25” spacing must be provided.
- CAUTION: Do not touch exposed metal parts. Shut branch circuit power before installing or servicing equipment. There are no user-serviceable parts inside. Refer installation and servicing to qualified service personnel.
- When the use of stand-by batteries is desired, they can be LiFePO4 (lithium iron phosphate), lead acid, or gel type.
- If batteries are housed in a weather-proof enclosure (NetWay5BTQWP, NetWay5BTQWPX), they must be properly ventilated. Use Altronix Vent2 kit. Connect a battery to terminals marked [– BAT 24V +] on the power supply board.
- Note: When batteries are not used, a loss of AC will result in the loss of output voltage.
- Note: When using two 12V LiFePO4 (lithium iron phosphate) batteries, check with manufacturer specifications that batteries can be connected in series.
- For outdoor battery backup, the battery enclosure must have sufficient ventilation.
- Battery operational temperature should be rated 10-15ºC lower than the manufacturer’s rated high temperature.
NetWay5BTQ, NetWay5BTQWPN:
- Mount NetWay5BTQ/NetWay5BTQWPN in the desired enclosure/location (mounting hardware is included).
- NetWay5BTQ/NetWay5BTQWPN can be powered by a 48-56V ITE power supply, e.g. Altronix PoE240 or PoE360 power supply/charger.
Input/Data Connections:
- Connect a Data source to the [Data Input] RJ45 jack (Fig. 1b, pg. 4).
- Connect Access Control boards, Altronix LINQ units, or other IP devices to the [Port 1 – Port 4] RJ45 jacks (Fig. 1c, pg. 4). Refer to the corresponding Installation Guides for details.
Terminal and Port Identification: NetWay5BTQ PoE+ Switch
Terminal/Port Legend | Function/Description |
---|---|
GND +54V | Connect a 48-56 VDC UL-listed power source to these terminals |
carefully observing polarity. (Fig. 1a, )
Data Input| Can be used as a Data Uplink (Fig. 1b).
Port 1 – Port 4| Data and PoE/PoE+ (IEEE 802.3af, 802.3at, 802.3bt compliant)
ports (Fig. 1c).
Master Reset| Resets NetWay5BTQ to factory settings. See Factory Reset Option
, pg. 9 (Fig. 1d).
USB Port| Can be used as an option to configure the NetWay5BTQ for managed
operation (Fig. 1e ).
Technical Specifications
Parameter | Description |
---|---|
Input Power Requirements | NetWay5BTQWP, NetWay5BTQWPX, NetWay5BTQX, |
NetWay5BTQPL: 120VAC, 60Hz, 4.5A.
NetWay5BTQ/NetWay5BTQWPN: 48-56V from a UL Listed power source.
Output| Four (4) PoE/PoE+ ports. Single data uplink port.
**** Indicators| NetWay5BTQ: Individual PoE On LEDs for each port.
Individual IP Link status, 100/1000Base-T/active LEDs for each port.
**** Environmental Conditions| Operating Ambient Temperature: – 30ºC to 70ºC (– 22ºF to 158ºF).
Storage Temperature: – 40ºC to 85ºC (– 40ºF to 185ºF).
Humidity: 20 to 85%, non-condensing.
Operating Altitude: – 304.8 to 2,000m.
**** Weights (approx.)| Model| Product Weight| Shipping Weight
NetWay5BTQWP NetWay5BTQWPN NetWay5BTQWPX NetWay5BTQX NetWay5BTQPL NetWay5BTQ|
10.5 lb. (4.76 kg)
3.7 lb. (1.68 kg)
15 lb. (6.8 kg)
6.65 lb. (3.02 kg)
2.6 lb. (1.18 kg)
0.25 lb. (0.11 kg)
| 11.9 lb. (5.4 kg) 5 lb. (2.27 kg)
17.5 lb. (7.9kg) 7.55 lb. (3.42kg) 4.0 lb. (1.81kg) 0.75 lb. (0.34 kg)
Typical Application
To Networked Access Controllers, Devices & Cameras, and/or Altronix LINQ
Series Ethernet connections.
NetWay5PBTQWP, NetWay5PBTQWPX, NetWay5PBTQX, and NetWay5BTQPL are factory
connected to the Power Supply
Configuring NetWay5BTQ for Network Connection
- Please be sure to visit altronix.com for latest firmware and installation instructions
Factory Default Settings
- IP Address: 192.168.168.168
- User Name: admin
- Password: admin
- Set the static IP address for the laptop to be used for programming to the same network IP address as the NetWay5BTQ. The default address of the NetWay5BTQ is 192.168.168.168, E.I. 192.168.168.200.
- Connect one end of the network cable to the network jack on the NetWay5BTQ and the other to the network connection of the laptop.
- Open a browser on the computer and enter “192.168.168.168” into the address bar.
- A dialog box Authentication Required will appear requesting both user name and password. Enter the default values here. Click on the button labeled Log In.
- The status page of the NetWay5BTQ will appear. Click on the tab labeled Network Settings.
- This will open the Network Setting screen. In this screen, the MAC Address of the NetWay5BTQ module will be found along with the Network Settings and Email Settings.
Network Settings:
- In the IP Address Method field select the method that the IP Address for the NetWay5BTQ will be obtained (STATIC or DHCP), then follow the appropriate steps.
Static:
- A. IP Address : Enter the IP address assigned to the NetWay5BTQ by the network administrator.
- B. Subnet Mask: Enter the Subnet of the network.
- C. Gateway : Enter the TCP/IP gateway of the network access point (router) being used.
- Gateway configuration is required to properly receive emails from the device.
- D. HTTP Port: Enter the HTTP port number assigned to the NetWay5BTQ module by the network administrator to allow remote access and monitoring.
- The default inbound port setting is 80. HTTP is not encrypted and insecure.
- Even though HTTP can be used for remote access, it is recommended primarily for use with LAN connections.
- E. HTTPS Port: Enter the HTTPS port number assigned to the NetWay5BTQ module by the network administrator to allow remote access and monitoring.
- The default inbound port setting is 443.
- Being encrypted and more secure, HTTPS is highly recommended for remote access.
- F. Click the button labeled Submit Network Settings.
- A dialog box will display “New network settings will take effect after the server is rebooted”. Click OK.
DHCP:
- A. After selecting DHCP in the IP Address Method field click the button labeled Submit Network Settings.
- A dialog box will display “New network settings will take effect after the server is rebooted”. Click OK.
- Next, click on the button labeled Reboot Server. After rebooting the NetWay5BTQ will be set in the DHCP mode. The IP address will be assigned by the router when the NetWay5BTQ is connected to the network.
- It is recommended to have the assigned IP Address reserved to ensure continued access (see the network administrator).
- B. Subnet Mask: When operating in DHCP, the router will assign the subnet mask values.
- C. Gateway: Enter the TCP/IP gateway of the network access point (router) being used.
- D. HTTP Port: Enter the HTTP port number assigned to the NetWay5BTQ module by the network administrator to allow remote access and monitoring.
- The default inbound port setting is 80. HTTP is not encrypted and insecure. Even though HTTP can be used for remote access, it is recommended primarily for use with LAN connections.
Secure Network Setup (HTTPS):
To set up HTTPS for a Secure Network Connection, a Valid Certificate and Key
must be used. Certificates and Keys should be in a “.PEM” format.
Self Certifications should only be used for testing purposes as no actual
authentication is being performed. In a Self-Certified mode, the connection
will still state that it is unsecure.
How to upload the Certificate and Key to set HTTPS:
- Open the Tab Labeled “Security”
- Select the Tab Labeled “Email/SSL”
- Scroll to the bottom under “SSL Settings”
- Click “Select Certificate”
- Browse and select a valid Certificate to upload from the server
- Click “Select Key”
- Browse and select a valid Key to upload from the server
- Click “Submit Files”
- Once the Certificate and Key is uploaded successfully you can proceed with setting up HTTPS in Network Settings.
- A. HTTPS Port: Enter the HTTPS port number assigned to the NetWay5BTQ module by the network administrator to allow remote access and monitoring. The default inbound port setting is 443.
- Being encrypted and more secure, HTTPS is highly recommended for remote access.
- B. Click the button labeled Submit Network Settings.
- A dialog box will display “New network settings will take effect after the server is rebooted”. Click OK.
Factory Reset Option:
- Power the unit down. Allow approximately 30 seconds for the unit to power down completely.
- Depress the Factory Reset button on NetWay5BTQB while reapplying power to the unit (Fig. 1d).
- Continue holding the button until the LEDs on board go through the start-up cycle, then release the button.
- The unit returns to the original factory settings.
VLans
VLANs (Virtual Local Area Networks) are subnetworks that allow for the
grouping together of devices for improved network traffic as well as providing
higher security by allowing greater control over which devices have access to
each other.
It is important to plan how you will set up your devices for each VLAN.
Configuring VLAN on the Altronix NetWay5BTQ Series Switch:
- Ensure the Laptop or PC being used to program the vLan settings is on a port that will be assigned to your first vLan configuration. By default, the management portion of the software is assigned to vLan-1.
- CAUTION: Changing VID=1, the industry-standard VLAN HOST address to any other VID address should be done with caution and performed only locally, since the change will drop the original HOST connection.
- Local access then facilitates a physical reconnection to the respective port.
- Note: Only this vLan network allows access to IP management.
- In the Network Section click on the VLan Tab.
- Click Add vLan.
- Enter a name for the VLAN.
- Enter a VLAN ID, i.e. 10, 20, etc. Ensure this vLan ID is associated with a vLan set up on the main switch and that your Laptop or PC being used for programming is on this same ID.
- Note: vLan ID could be any value 2-4094.
- Assign vLan QOS (Quality of Service) priority. 0 = Lowest and 7 = Highest
- Pick a Trunk port (Tagged Ports). Trunk ports are typically the main connection for network traffic for each group. They are usually connected to a network switch, WAPs, etc.
- Pick the Access port(s) (Untagged Ports) associated with the vLan. Access Ports are typically used for Cameras, etc. If programming locally, ensure your laptop or PC is connected to one of these ports.
- Save Configuration.
- Repeat steps 2 – 9 to add another vLan.
- If the unit is accidently programmed incorrectly and you cannot get into the NetWay5BTQ series programming, physically moving ports of your PC connected to the main switch to a correct port (when being programmed remotely), or, as a last resort, completing a factory reset locally and reprogramming the unit.
- Advanced Port Settings:
Unknown VID Packet Forwarding Configuration:
- On ingress unknown VID, forward to a fixed set of ports. By default, no forwarding is set.
Configuration on Ingress Untagged Traffic:
- Trunk Port action for ingress UNTAGGED packets. By default do not drop packets.
Keep Tag on Egress:
- Select if you want ACCESS Port to keep the VLAN tag when sending egress packets.
- By default tags are stripped.
Preferred VLAN Forwarding:
- For ACCESS Ports that belong to more than one VLAN. Select preferred vLan to forward UNTAGGED ingress packets. By default preferred vLan is the last vLan created.
Typical VLan Setup
Any Ethernet port can be used for VLan pass-through
Wall Mount Installation
- Place the unit at the desired location and secure it with mounting screws (not included) (Fig. 4,
Pole Mounting Using Optional Pole Mount Kit
PMK1 (NetWay5BTQWPN and NetWay5BTQWP) or PMK2 (NetWay5BTQWPX):
This installation should be made by qualified service personnel. This product contains no serviceable parts. Pole mount kits are intended for use with Altronix outdoor-rated power supplies or accessories housed in WP1, WP2, WP3, and WP4 enclosures. Brackets are designed for use with the Wormgear Quick Release Straps (two included).
- Thread one (1) wormgear quick-release strap through the slots on the back of a mounting bracket (Fig. 5.
- Once the desired height of the top Pole Mount bracket is achieved, tighten the straps down by sliding open end of the strap through the locking mechanism on the strap, then tighten the screw with a flat head screwdriver or 5/16” hex socket driver (Fig. 6 and.
- Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket, tightening bolts with a 7/16” hex socket (Fig. 8).
- Thread the second wormgear quick-release strap through the slots on the back of the bottom mounting bracket (Fig. 8).
- Mount the enclosure onto the top bracket by inserting bolts through the flange of the enclosure and into the bracket, tightening bolts with a 7/16” hex socket (Fig. 9).
- Tighten the straps of the bottom bracket down by sliding the open end of the strap through the locking mechanism on the strap, then tighten the screw with a flathead screwdriver or 5/16” hex socket driver (Fig. 9).
- Clip excess straps.
NetWay5BTQPL
Mechanical Drawing and Dimensions (H x W x D approx.): 10.75” x 8.875” x 2.375” (273.1mm x 225.4mm x 60.3mm
NetWay5BTQWPN
Mechanical Drawing and Dimensions (H x W x D approx.): 9.5” x 7.32” x 4.92” (241.3mm x 185.9mm x 125mm)
NetWay5BTQWP
Mechanical Drawing and Dimensions (H x W x D approx.): 13.31” x 11.31” x 5.59” (338.1mm x 287.3mm x 142mm)
NetWay5BTQWPX
Mechanical Drawing and Dimensions (H x W x D approx.): 17.53” x 15.3” x 6.67” (445.3mm x 388.6mm x 169.4mm)
NetWay5BTQX
Mechanical Drawing and Dimensions (H x W x D approx.): 13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.6mm)
- Altronix is not responsible for any typographical errors.
- 140 58th Street, Brooklyn, New York 11220 USA
- phone: 718-567-8181
- fax: 718-567-9056
- website: www.altronix.com
- e-mail: info@altronix.com
- Lifetime Warranty
- NetWay5BTQ Series C06X
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>