tuya TLC2101 Smart Wired Water Tank Indicator User Manual

July 23, 2024
Tuya

tuya TLC2101 Smart Wired Water Tank Indicator User Manual

overview

Thank you for purchasing the Wired/Wireless Ultrasonic Liquid Sensor with Display.
Theultrasoniclevelsensormeasuresthelevelwithoutcontactwiththeliquid.
Thesensorsendsanultrasonicsignal,whichisreflectedbackfromtheliquid surface.Thefilllevelcanthusbedetermined.Thesensorcanbeusedforoil and water tanks.

  • Radioultrasonicsensorformonitoringthefillinglevelofatank/live transmission
  • Canbeusedforvariousliquids,sincetheultrasonicsensordoesnot resultindirectliquidcontact
  • DetectRange:10cmto250cmcanmeasurehightanks
  • Wirelessrange:100m(withoutobstacles/withoutinterference)
  • High and Low liquid alarm function
  • Ideal for retrofitting water/oil tanks
  • With surface thermometer and room thermometer

mountthesensoronthetank

Thesensorshouldbeinthemiddleofthetankandnotonaliquidinlet.Thiscan falsifythemeasurementresult.Pleaserefertothefollowingpicturesforthebest installationpositions.Theholeshouldbe72mm.

display program

  1. Press and hold button 2) (Menu) for 3 seconds. This takes you to the programming mode. If there is no operation for 10 seconds, the controller automatically exits the programming mode

  2. Press button (menu) to access the 3 setting options 1. Time/2. Tank /3, Alarm

  3. Set time As shown in the picture. When the “TIME” letter appears at the bottom of the monitor screen, the device enters the time setting: press the button to increase and decrease the time to calibrate, click the button to switch the hour/minute setting

  4. Key (Menu) to go to the next step

  5. Adjust tank height
    1st value: As shown in the picture. When the “TANK” letter appears at the bottom of the display screen and the water level icon under the water tank flashes, the device enters the low water level setting of the water tank: 2.5M in the display is the distance setting from the ultrasonic sensor to the bottom of the water tank. Set the actual distance from the sensor to the low level of the water tank by pressing the button +
    Example: The tank is 2.5m high (distance from sensor to floor). So set 2.5m

  6. Key (Menu) to go to the next step.

  7. Set alarm: As shown in the picture. When the “ALARM” letter appears at the bottom of the display screen, the device enters the alarm level setting press to set the alarm level in percentage of the water tank level. Each grid is 10%.

  8. To complete the programming process and save the settings, press button 2(menu) for 3 seconds Or no operation for 10 seconds to exit Note: Alarm Beeping can be mute by press Model Switching

technical specifications:

  • Model:WiredSmartTLC2101/WirelessSmartTLC2101WL
  • Sensor dimensions/weight:71mmx95mm/143g
  • Displaydimensions:85x95mmx43mm
  • TransferRangewithoutobstacles:100m

Click the button to switch the mode
2nd value. As shown in the picture. When the “TANK” letter appears at the bottom of the display screen and the water level icon on the water tank flashes, the device enters the high-water level setting of the water tank D. 1M in the display is to set the distance from the ultrasonic sensor to the high-water level of the water tank. Set the actual distance from the sensor to the high level of the water tank by pressing the button
Example: 0.2m distance between the sensor and the max. Ming quantity full level. So set 0.2m

  • Power adapter: DC9V/1A
  • Consumption : 100mA
  • Ultrasound frequency: 40kHz
  • Working temperatures: 0 to 70°C
  • Liquid measurement radius: 10-250cm
  • Degree of protection IP66

ATTENTION!

SAFETY INSTRUCTIONS

in particular, the product must not be used in the following cases and for the following purposes: Potentially explosive environment-When operating in potentially explosive areas, sparking can lead to deflagration, fire or explosions

  • Use as a safety device The product does not replace the function of a limit indicator on the heating oil tank
  • Use with aggressive liquids
  • Use as overfill protection
  • Use for biling purposes (the product is not calibrated)
  • In connection with products that directly or indirectly serve human, health or life-saving purposes, or the operation of which may pose a risk to people animals or propert