Specifications
- Model: AL200190
- Product Components:
- Activated charcoal filter (AA200100)
- Air recirculation module 90cm (AA200890)
- Regenerable air recirculation module 90cm (AA200892)
- Installation kit surface mounting (AA200900)
- Installation kit remote motor (AA200910)
- Installation kit (seamless combination) 90cm downdraft extractor 200 series
- Features:
- Extendable table ventilation
- Flush installation
- Perfect for frameless induction cooktops
- Transparent ventilation screen for discreet integration
- Ambient lighting through glass edges
- Guided Air technology for high vapor catch rate
- Energy Efficiency:
- Energy efficiency class: A
- Energy consumption: 37.8 kWh/year
- Ventilation efficiency class: A
- Grease filter efficiency class: C
- Sound level: min. 41 dB / max. 62 dB normal mode
- Connection:
- Total connected load: 300 W
- Power consumption standby/display off: 0.4 W
Product Usage Instructions
Installation:
Follow the instructions provided in the user manual for proper installation. Ensure the installation kit is used correctly to guarantee stability and functionality.
Operation:
- Activate the unit using the designated controls.
- Adjust the ventilation settings according to your cooking needs.
Maintenance:
- R egularly clean the grease filter to maintain efficiency.
- Check and replace the activated charcoal filter as needed.
Frequently Asked Questions
- Q: How can I switch off the WiFi module?
- A: Please refer to the user manual for specific instructions on switching off the WiFi module.
- Q: What should I do for installation in a single worktop cut-out?
- A: Use the installation accessory VA200090 between the appliances, including a connection strip and furniture supports for cabinet stability.
Models
- AL200190
- AA200100:
- Activated charcoal filter
- AA200890:
- Air recirculation module 90cm
- AA200892:
- Regenerable air recircul. module 90cm
- AA200900:
- Installation kit surface mounting AL200
- AA200910:
- Installation kit remote motor
- VA200090:
- Installation kit (seamless combin.) 90cm
Product Information
downdraft extractor 200 series 90 cm, flush installation AL200190
Extendable table ventilation, when not in use can be completely lowered into the worktop Perfect in combination with frameless induction cooktops 90 cm wide for flush mounting Transparent ventilation screen for discreet integration in the kitchen space Ambient lighting through the glass edges Guided Air technology ensures high vapour catch rate across the whole cooktop
Output
- Performance and noise level, output level 3/Intensive:
- Air output according to EN 61591. Sound power level according to EN 60704-3. Sound pressure level according to EN 60704-2-13. Odour reduction for air recirculation in accordance with EN 61591.
Air extraction:
-
519 / 833m³/h.
-
62 / 71 dB (A) re 1 pW.
-
Air recirculation (with standard activated filters):
-
472 / 620m³/h.
65 / 71 dB (A) re 1 pW. -
Odour reduction: > 90 %
Features
Cooktop-based ventilation control. Automatic function with sensor-controlled run-on function. 3 electronically controlled power levels and 1 intensive mode. Grease filter saturation indicator. Activated charcoal filter saturation indicator. 2 large-scale metal grease filters included, easy to remove, dishwasher-safe. Overflow capacity 170 ml in grease filter. Additional capacity 600 ml in the remote fan unit. Activated charcoal filter easily removeable from above for air recirculation system. Gaggenau Black anodized aluminium frame. 1 user interface to set the power levels and 1 user interface to control the Guided Air technology. Fan technology with highly efficient, brushless DC motor (BLDC). Flexible installation of the fan unit at the front (for a compact wall solution), at the back (without loss of drawer space), or at a distance from the appliance. Home network integration for digital services (Home Connect) wireless via WiFi. The use of the Home Connect functionality depends on the Home Connect services, which are not available in every country. For further information please check: home-connect.com.
Consumption data
- Energy efficiency class A at a range of energy
- efficiency classes from A+++ to D.
- Energy consumption 37.8 kWh/year.
- Ventilation efficiency class A.
- Illumination efficiency class -.
- Grease filter efficiency class C.
- Sound level min. 41 dB / max. 62 dB normal mode.
Planning notes
Compatible with frameless cooktops 400 series (CX 492) or 200 series (CI 292), in a single worktop cut-out. The table ventilation can be installed in the cabinet or between two (e.g. for an island installation deeper than 100 cm).Width of the cabinets 90 cm, 100 cm or 120 cm. No upper cabinets should be installed above the table ventilation to maintain optimum performance.
The following distance should be observed:
- 50 cm left and right of the table ventilation to the wall or neighboring tall cabinets. – 5 cm from the table ventilation frame to the wall. Installation is possible in worktops made of stone, synthetics or solid wood. Heat resistance and watertight sealing of the cut edges must be observed. Concerning other materials please consult the worktop manufacturer. To install the fan unit at a distance, an installation kit is required (with spare covers for closing air outlets). Maximum distance 3 m. In air extraction a one-way flap with a maximum opening pressure of 65 Pa should be installed. In air extraction mode, always ensure adequate fresh air in the room if the appliance is being operated at the same time as a chimney-vented fireplace. For optimum performance in air recirculation, we recommend an outflow surface area of at least 400 cm². For air recirculation an air recirculation module is required.
Connection
Total connected load 300 W. Power consumption standby/display off 0.4 W. Please check the user manual for how to switch off the WiFi module. For installation in a single worktop cut-out the installation accessory VA 200 090 must be placed between the appliances. This includes a connection strip and furniture supports that ensure cabinet stability.
Installation Instruction
- A Fxelible appalace in the lanni a Tuton, at the back at a distance Fan unit must always be accessible (We Win Not recommend for non-thermal insulated outer wallo Hoor Measurements in mm
AL 200 in combination with frameless cooktop CX 492 / Cl 292 in\ a single cut- out
Flush installation
View from above
AL 200 in combination with frameless cooktop CX 492 / Cl 292 in a single cut- out
Flush installation
AL 200 in combination with frameless cooktop CX 492 / Cl 292 in a single cut- out
Flush installation
Cross section
- A: 6.5+05 mm
- B: 2.5 mm
- C: Fill with silicone
- D: Front
- E: Table ventilation
- F: Induction cooktop
Measurements in mm
AL 200 in combination with induction cooktop in 2 separate cut-outs
View from above
AL 200 in combination with induction cooktop in 2 separate cut-outs
Surface installation
AL 200 in combination with induction cooktop in 2 separate cut-outs
Flush installation
- A: Incl. 2 mm silicone joint all around
- B: 5.5 mm
- C: 9.5 mm
Measurements in mm
AL 200 in combination with induction cooktop in 2 separate cut-outs
Side view
- A: ≥ 20 mm from the Guided Air suction area to a cabinet wall
- B: ≥ 60 mm for air recirculation
- ≥ 100 mm for air extraction with ducting in the plinth
Measurements in mm
AL 200 in combination with frameless cooktop VI 492 in a single cut-out
Flush installation
View from above
AL 200 in combination with frameless cooktop VI 492 in a single cut-out
Flush installation
AL 200 in combination with frameless cooktop VI 492 in a single cut-out
Flush installation
Longitudinal section
- A: 6.5+0.5 mm
- B: 2.5 mm
- C: 13.5 mm
- D: Fill with silicone
Measurements in mm
AL 200 in combination with frameless cooktop VI 492 in a single cut-out
Flush installation
Cross section
- A: 6.5+0.5 mm
- B: 2.5 mm
- C: Fill with silicone
- D: Front
- E: Table ventilation
- F: Induction cooktop
- Measurements in mm
AL 200 190 with AA 200 910
- A: Access to the complete cover must be ensured even after installation Cover can be installed on the front or the rear from the appliance
Measurements in mm
AL 200 in combination with frameless cooktop VI 492 in a single cut-out
Flush installation Side view
- A: Front thickness
- B: ≥ 60 mm for air recirculation
- ≥ 100 mm for air extraction with ducting in the plinth
- C: ≥ 850 mm for air extraction with ducting in the plinth
- D: ≥ 20 mm from the Guided Air suction area to a cabinet wall
Measurements in mm
Side view
- A: Front thickness
- B: ≥ 60 mm for air recirculation
- ≥ 100 mm for air extraction with ducting in the plinth
- C: ≥ 850 mm for air extraction with ducting in the plinth
- D: ≥ 20 mm from the Guided Air suction area to a cabinet wall
Measurements in mm
Longitudinal section
- A: 6.5+0.5 mm
- B: 2.5 mm
- C: 13.5 mm
- D: Fill with silicone
Measurements in mm
Side view
- A: Front thickness
- B: ≥ 60 mm for air recirculation
- ≥ 100 mm for air extraction with ducting in the plinth
- C: ≥ 850 mm for air extraction with ducting in the plinth
- D: ≥ 20 mm from the Guided Air suction area to a cabinet wall
Measurements in mm
AL 200 in combination with frameless cooktop CX 492 / Cl 292 in a single cut-out
Flush installation Side view
- A: Front thickness
- B: ≥ 60 mm for air recirculation
- ≥ 100 mm for air extraction with ducting in the plinth
- C: ≥ 850 mm for air extraction with ducting in the plinth
- D: ≥ 20 mm from the Guided Air suction area to a cabinet wall
Measurements in mm
References