Danfoss AC398627135831 Key to Energy Efficiency Instruction Manual

July 23, 2024
Danfoss

Danfoss AC398627135831 Key to Energy Efficiency

Introduction

Retrofits: The key to energy efficiency, cost savings and decarbonization of SWRO’s installed base

Over the last century, and especially during the last few decades, desalination has become significantly more energy efficient. As we pointed out in our blog, A brief history of the energy intensity of desalination, since the first desalination plant appeared in 1928, technological innovation has driven down the specific energy consumption (SEC) from nearly 30 kWh/m3 for multi-stage flash thermal distillation to about 2 kWh/m3 for SWRO.

But as much of the installed base of desalination plants was built before the latest energy-saving technology was developed – in particular isobaric energy recovery devices (ERDs) and the most efficient high-pressure pumps – a good share of existing desalination capacity is more energy-intensive than it could be. In fact, much more.

Retrofitting desalination’s installed base for energy efficiency would help decarbonization and enable huge financial savings

In an article we created for Global Water Intelligence, we calculated the potential savings if the worldwide installed base of desalination plants (21,755 plants in all, with a combined capacity of 128 million m3 ) was as energy-efficient as it could be, i.e., with an SEC of 2 kWh/m3 , the current “state of the art.” Of course, this exercise was based on some assumptions, and the results must be taken with a grain of salt. Nonetheless, this ballpark estimate reveals the striking potential of retrofitting for energy efficiency:

  • educed energy consumption: Power plants would need to produce 73% less energy annually for desalination, or 247 tWh less than they do now.
  • Financial savings: Plant owners and operators would save €34.5 billion annually.
  • Decarbonization: The planet would be spared 111 million tons of CO2 annually – more, for example, than the entire country of Bangladesh emits each year.

In addition to these very significant energy savings, there are other good reasons to retrofit older SWRO plants. For example, the latest membrane technologies require less pressure than their predecessors. In addition, their higher recovery rates mean that less feed water is used and fewer chemicals are required for backwashing, reducing desalination’s impact on marine environments.

What do desal plant retrofits typically involve?

Everything mechanical eventually wears out and needs to be repaired or replaced. But retrofits for energy-saving focus on a handful of equipment types and configurations.

  • ERDs: If a plant has no ERDs or relies on non-isobaric technology such as Pelton turbines or turbochargers, then ERDs are always at the top of the list. As we described in our blog, Understanding the cost drivers of SWRO, ERDs alone can save up to 60% of total energy costs.
  • High-pressure pumps: Creating appropriate pressure requires 80% of an SWRO plant’s electricity usage. Replacing centrifugal pumps with axial piston technology reduces overall energy consumption by 20-30%.
  • Motors, pipes, and fittings : If ERDs are installed where none were before, then motors, pipes and fittings may need to change, too, in order to maintain consistent flow levels.
  • Membranes: As noted above, the latest membrane technologies require less pressure (i.e., less energy) in addition to requiring fewer chemicals.
  • Trains: Retrofits that include replacing Pelton turbines with isobaric ERDs often result in combining trains to continue using the installed high-pressure pumps and motors. While this has the advantage of saving cost, it has the disadvantage of decreasing redundancy in case of breakdowns or shutdowns due to maintenance.

If retrofitting is such a good idea, why don’t more plant owners and

operators do it?

Given the striking potential of retrofits to save energy, one would think that all desalination plant owners with older technology would already have switched out their old technology for the latest, best-in-class alternatives. Indeed, many have, and even more will do so in the future. Still, many others continue to wait.

Why? Poor awareness of the benefits of retrofitting, reluctance to be an early adapter of new technology, and the inertia of not fixing what hasn’t broken all matter. But the biggest reasons are CAPEX and payback time. As the old saying goes, it takes money to save money.

For some plant owners, access to the capital required to retrofit their plant is problematical. For others, a payback time of anything more than a year raises doubts – even though they could save energy, money, and CO2 over a longer time horizon. As we pointed out in our blog, Understanding SWRO’s total cost of ownership, relatively small CAPEX investments can have an outsized impact on OPEX and TCO. Still, not all desalination investment decisions are made with a TCO mindset.

We will see more retrofits of desalination plants in the future

As the world is increasingly focused on energy efficiency and having enough water for growing populations and industry, retrofits of desalination plants will be increasingly relevant in the future.
Much of the installed base would benefit from them, as money saved is money earned, just as CO2 emissions that are prevented do not add to global warming.

Climate change and growing awareness of the critical importance of decarbonization make the case for retrofits increasingly compelling. If the financial reasons outlined in this blog do not motivate owners and operators to retrofit for greater energy efficiency, carbon pricing and other forms of governmental regulation will likely add additional incentives.

Indeed, subsidies are already one way to encourage retrofits. Government action is important to shift attitudes and encourage action – see for example our blog, Energy-efficient SWRO should be part of the European Green Deal, to learn more about how the EU, for example, could encourage the transition from low-efficiency to high-efficiency desalination.

Danfoss A/S
High Pressure Pumps • danfoss.com • +45 7488 2222 • E-mail: highpressurepumps@danfoss.com

Any information, including, but not limited to information on selection of product, its application or use, product design, weight, dimensions, capacity or any other technical data in product manuals, catalogues descriptions, advertisements, etc. and whether made available in writing, orally, electronically, online or via download, shall be considered informative, and is only binding if and to the extent, explicit reference is made in a quotation or order confirmation. Danfoss cannot accept any responsibility for possible errors in catalogues, brochures, videos and other material.
Danfoss reserves the right to alter its products without notice. This also applies to products ordered but not delivered provided that such alterations can be made without changes to form, fit or function of the product. All trademarks in this material are property of Danfoss A/S or Danfoss group companies. Danfoss and the Danfoss logo are trademarks of Danfoss A/S. All rights reserved.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals