Danfoss Type 077B7 Service Thermostats Installation Guide

July 23, 2024
Danfoss

Danfoss Type 077B7 Service Thermostats

Danfoss-Type-077B7-Service-Thermostats-product

Specifications

  • Model Numbers: 077B218, 077B223, 077B7099, 077B7100, 077B7101,077B7102, 077B7103, 077B7104, 077B7105, 077B7108, 077B7109,  077B7274, 077B7242, 077B7049
  • Length of Capillary: L = 1200 +30/-0 mm
  • Min. Sensor Length Mounted on Evaporator: LS = 95-105 mm (varies based on model)
  • Usage: Service thermostats for various refrigeration appliances

Product Usage Instructions

Installation Guide
Follow the guidelines provided in the installation guide for proper setup of the service thermostats.

Setting Adjustment
Adjust the cut-in and cut-out temperatures as needed for your specific appliance using the designated settings.

Sensor Length Requirements
Ensure the minimum sensor length mounted on the evaporator is met according to the specifications mentioned for each model.

Cold Setting Position
Select the desired cold setting position (3 or 4) based on your cooling requirements.

Additional Information
For more detailed usage instructions and troubleshooting tips, refer to the complete user manual provided with the product.

Frequently Asked Questions (FAQ)
Q: What is the recommended sensor length for the evaporator?
A: The recommended minimum sensor length mounted on the evaporator varies between 95mm to 105mm depending on the specific model.

Installation Guide

Service thermostats
Type 077B7

Danfoss-Type-077B7-Service-Thermostats- \(2\) Danfoss-Type-077B7-Service-Thermostats- \(3\) Danfoss-Type-077B7-Service-Thermostats-
\(5\) Danfoss-Type-077B7-Service-Thermostats-
\(6\)

Accessories for 077B7099

Danfoss-Type-077B7-Service-Thermostats- \(8\) Danfoss-Type-077B7-Service-Thermostats- \(1\)

  • The 077B….EBD, 077B….L EBD can be applied on systems with R290 and R600a as the working fluid.
  • For countries where safety standards are not an indispensable part of the safety system Danfoss recommends the installer to get a third-party approval of the system containing flammable refrigerant.

Note: All temperatures at 760 mm Hg (except 077B7242 at 700 mm Hg).

Danfoss A/S Climate Solutions • danfoss.com
+45 7488 2222 Any logues description adVertisements etc. and water made available in writing, orally, electronics, online or sid downed, small be considered in amative, all is clay binding it auc to anualS, extent, explicit reference is made in a quotation or order confirmation. Danfoss cannot accept any responsibility for possible errors in catalogs, brochures, videos and other material. Danfoss reserves the right to alter its products without notice. This also applies to products ordered but not delivered provided that such alterations can be made without changes to form, fit or function of the product. All trademarks in this material are property of Danfoss A/S or Danfoss group companies. Danfoss and the Danfoss logo are trademarks of Danfoss A/S. All rights reserved.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals