QTL QOM-eLED-60 Outdoor Power Supplies Instruction Manual
- July 20, 2024
- QTL
Table of Contents
- Important Information
- Housing
- Mounting Options
- Connecting and Configuring the LINEAR drive 100D/180D
- Primary Wiring
- Secondary Wiring
- Control Wiring
- Manual Configuration
- Other Features
- Wiring Installation
- CSA Requirements
- CUSTOMER SUPPORT
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
QTL QOM-eLED-60 Outdoor Power Supplies
Important Information
- Must be installed by licensed electrician.
- Installation must be in accordance with DMX512-A standard
- DMX Shield must be grounded to Earth Ground at a single point external to power supply
WARNING
Risk of Fire / Electric Shock
Transformer should be installed by a Licensed electrician in accordance with the N.E.C. and all local codes in force.
LOW VOLTAGE LIGHTING SYSTEM &
LANDSCAPE LIGHTING SYSTEMS
CLASS: 3425-15
3425-95
3402-15
3402-95
- Wear rubber shoes and work on a sturdy wooden or fiberglass ladder.
- This power supply must be installed according to the National Electric
- Code and local codes and ordinances.
- This power supply is to be installed and serviced only by an licensed electricians.
- This power supply is to be installed so that it is not likely to be contacted by people.
- To avoid a hazard to children, account for all parts and destroy all packaging materials.
Housing
Mounting Options
NOTE:
- To order additional lengths of wire for connection in the secondary. Please call factory for availability.
- QOM must be installed as shown.
Connecting and Configuring the LINEAR drive 100D/180D
Primary Wiring
Commonly Asked Questions
-
How can I verify my installation?
Apply AC input, verify display turns on : This confirms AC input wiring Run “Visual Test Run” : This verifies wiring of LEDs. Make sure LEDs turning on go in same order as the Test Run -
I don’t have a controller yet, how can I keep my lights on?
Change the Mode to “COLOR” : This allows to manually set a specific color to be on
Adjust the Hue or WHITE to achieve the desired color : This sets that specific color -
My LEDs aren’t coming out the right color. They look like white has been added in Verify the Network Resolution
“NETW RES” : Default is 8 BT Check your DMX Programming. Stick controllers come with RGB programs by default. This will cause RGBW LEDs
to show Pink vs. Red
Secondary Wiring
Control Wiring
DMX Connections
WARNING: Risk of electrical shock. May result in serious injury or death.
Disconnect power before servicing or installing.
CAUTION: The device may only be connected and installed by a qualified
electrician. All applicable regulations, legislation and building codes must
be observed. Incorrect installation of the device can cause irreparable damage
to the device and the connected LEDs.
Manual Configuration
-
Select mode of operation
-
Set LED groups:
-
Standalone operation – Colour*-
or
Standalone operation – Show –
or
Networked operation DMX –
- The colour menu depends on the LED group settings you have selected in step 2.
Other Features
-
Visual test run
-
Locking the configuration:
-
Reset to factory defaults
Wiring Installation
QOM-eLED+DMX : for exterior
CSA Requirements
- Suitable for indoor and outdoor use
- This power supply must be installed according to the National Electric Code and local codes and ordinances and in accordance with applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
- Wear rubber shoes and work on a sturdy wooden or fiberglass ladder.
- This power supply is to be installed in a location where it is not likely to be contacted by non-electricians.
- To avoid a hazard to children, account for all parts and destroy all packaging materials.
- DMX shield wire must be grounded to earth ground at a single point external to power supply.
CUSTOMER SUPPORT
© 2024 QTL. All rights reserved | 155 Hill St. Milford,
CT 06460 | 203-367-8777 |
sales@QTL.lighting | QTL.lighting
Specification subject to change. Rev-06-11-24