PEDROLLO SAR 40 Lift and Collection Stations User Guide
- July 18, 2024
- pedrollo
Table of Contents
SAR 40
Lift and collection stations
INSTALLATION AND USE
The SAR 40 lift and collection stations are designed to handle clear water, rainwater, and wastewater from household drains like washing machines, dishwashers, and sinks, especially in situations where connection to the main sewer system is impractical or impossible due to distance or gravity constraints. The SAR 40 stations are compact and easy to install in basements, single-residence garages, or even underground
COMPONENTS INCLUDED
※ 40 litres polyethylene tank with a non-walkable and non-driveable cover.
※ Single-phase submersible pump.
※ Standard 5-metres power cable .
※ Swing check valve for models with drainage pumps only (for clear
wastewater).
AVAILABLE UPON REQUEST
※ SAR 40 lift station, equipped with a single-phase submersible pump with a
float switch, based on your specific requirements.
※ 10-metres power cable.
※ Full-flow check valve (for external installation) designed for vortex and
grinder pumps.
※ SAR 40 with grinder pump
TYPE| POWER (P2)| MAXIMUM FLOW RATE litres/min|
PREVALENCE MAX metres|
---|---|---|---|---
kW| HP
**TRITUS-TX| ****0.55| ****0.75| ****90| ****11.5**|
※ Suitable for sewage
※ Start of production 06.2024
※ SAR 40 with drainage pumps
TYPE| POWER (P2)| MAXIMUM FLOW RATE litres/min|
PREVALENCE MAX metres|
---|---|---|---|---
kW| HP
**TOP 1 -GM| ****0.25| ****0.33| ****160| ****6.0|
****RXm 1 -GM| ****0.25| ****0.33| ****160| ****7.0**|
※ Suitable for clear wastewater
※ SAR 40 with vortex pumps
TYPE| POWER (P2)| MAXIMUM FLOW RATE litres/min|
PREVALENCE MAX metres|
---|---|---|---|---
kW| HP
**TOP 2 VORTEX-GM| ****0.37| ****0.50| ****155|
****7.0|
****TEX 2| ****0.37| ****0.50| ****220| ****8.3**|
※ Suitable for dirty waste water
DIMENSIONS AND WEIGHT
KEY:
I collection pipe connection
U discharge pipe connection
S ventilation pipe connection
TYPE | I(1) PORTSU(1) | S(1) | h | kg |
---|---|---|---|---|
SAR 40 – TRITUS-TX | 1½” | 1¼” | ½” | 335 |
SAR 40 – TOP 1-GM | 305 | 14.3 | ||
SAR 40 – RXm 1-GM | 15.2 | |||
SAR 40- TOP 2 VORTEX-GM | 335 | 144 | ||
SAR 40 – TEX 2 | 15.0 |
EXAMPLES OF INSTALLATION
SAR 100
Lift and collection stations
INSTALLATION AND USE
SAR 100 lift and collection stations are designed to handle clear water,
rainwater, and wastewater from household drains like washing machines,
dishwashers, sinks, and toilets, especially in situations where connection to
the main sewer system is impractical or impossible due to distance or gravity
constraints. The SAR 100 stations are compact and easy to install either on
the floor or underground, both inside and outside of single or two-family
homes.
COMPONENTS INCLUDED
※ 100 litres polyethylene tank with a non-walkable and non-driveable cover.
※ Single-phase submersible pump.
※ Standard 10-metres power cable.
※ Electrical panel (only for SAR 100-TIGm 1.1 and 1.3)
AVAILABLE UPON REQUEST
※ SAR 100 lift station, equipped with a singlephase submersible pump with a float switch, based on your specific requirements
※ SAR 100 with drainage pumps
TYPE| POWER (P2)| MAXIMUM FLOW RATE
litres/min
| PREVALENCE MAX
metres
|
---|---|---|---|---
kW| HP
**TOP 3| ****0.55| ****0.75| ****260| ****10.0**|
**RXm 3| ****0.55| ****0.75| ****220| ****11.5**|
**Dm 10| ****0.75| ****1.0| ****300| 15.5|
****Dm 20| ****0.75| ****1.0| ****250| ****19.0**
※ SAR 100 with vortex pumps
TYPE| POWER (P2)| MAXIMUM FLOW RATE litres/min|
PREVALENCE MAX metres|
---|---|---|---|---
kW| HP
**TOP 3-VORTEX| ****0.55| ****0.75| ****170|
****8.2|
****RXm 3/20| ****0.55| ****0.75| ****240| ****9.5|
****ZXm 2/30| ****0.55| ****0.75| ****320| ****12.5|
****VXm 10/35| ****0.75| ****1.0| ****400| ****10.0**|
※ suitable for dirty waste water
※ SAR 100 with grinder pumps (TRITUS)
TYPE| POWER (P2)| MAXIMUM FLOW RATE litres/min|
PREVALENCE MAX metres|
---|---|---|---|---
kW| HP
TIGm 0.55| 0.55| 0.75| 130| 14.5|
TIGm 0.75| 0.75| 1.0| 140| 17.5
TIGm 1.1| 1.1| 1.5| 150| 22.5
TIGm 1.3| 1.3| 1.75| 250| 20.5
DIMENSIONS AND WEIGHT
KEY:
I collection pipe port
U discharge pipe connection
S ventilation pipe port
TYPE| 1| PORTS
U(1)| S| 11| 12| kg
---|---|---|---|---|---|---
SAR 100 – TOP 3| DN 110| 1¼”| DN 50| 145| 100| 29.0
SAR 100 – RXm 3| 1¼”| 29.9
SAR 100- Dm 10| 1¼”| 36.3
SAR 100- Dm 20| 1¼”| 36.3
SAR 100-TOP 3-VORTEX| 1¼”| 29.1
SAR 100- RXm 3/20| 1¼”| 30.0
SAR 100- ZXm 2/30| 1¼”| 33.1
SAR 100- VXm 10/35| 1¼”| 37.5
SAR 100- TIGm 0.55| 1¼”| 38.2
SAR 100- TIGm 0.75| 1¼”| 38.3
SAR 100- TIGm 1.1| 1¼”| 40.6
SAR 100- TIGm 1.3| 1¼”| 40.6
(1) Male threaded connection
SAR 250
Lift and collection stations
INSTALLATION AND USE
SAR 250 lift and collection stations are designed to handle clear water,
rainwater, and wastewater from household and civil drains like washing
machines, dishwashers, sinks, and toilets, especially in situations where
connection to the main sewer system is impractical or impossible due to
distance or gravityconstraints. SAR 250 stations are compact and easy to
install, suitable for floor or underground placement, both indoors and
outdoors of multi-unit buildings.
COMPONENTS INCLUDED
※ SAR 250 polyethylene tank with a non-driveable cover that can support
pedestrian traffic up to a maximum of 100 kg.
※ Single-phase submersible pump.
※ Electrical panel (only for SAR 250-TIGm 1.1 and 1.3).
※ Standard 10-metres power cable.
AVAILABLE UPON REQUEST
※ SAR 250 lift station, equipped with a sin-gle-phase submersible pump with a
float switch, based on your specific requirements.
※ Three-phase submersible pump
※ Alarm kit (Code: KSKIT-ALLARME) equipped with electrical panel, self-powered
siren, and float
※ 300 mm extension kit (Code No. KSKIT-308MA) for installing the “SAR” tank at
greater depths
※ “SAR” Stations with check valve and ball valve in the discharge pipe.
※ SAR 250 with drainage pumps
TYPE| POWER (P2)| MAXIMUM FLOW RATE litres/min|
PREVALENCE MAX metres|
---|---|---|---|---
kW| HP
TOP 3| 0.55| 0.75| 260| 10.0|
TOP 4| 0.75| 1.0| 320| 12.5
TOP 5| 0.92| 1.25| 360| 15.0
**RXm 3| ****0.55| 0.75| ****220| ****11.5|
Dm 10| 0.75| 1.0| 300| 15.5|
Dm 20| 0.75| 1.0| 250| 19.0
Dm 30| 1.1| 1.5| 275| 26.0**
※ suitable for clear wastewater
※ SAR 250 with VORTEX pumps
TYPE| POWER (P2)| MAXIMUM FLOW RATE litres/min|
PREVALENCE MAX metres|
---|---|---|---|---
kW| HP
**RXm 3/20| ****0.55| ****0.75| ****240| ****9.5|
****ZXm 2/40| ****0.55| ****0.75| ****400| ****11|
****VXm 10/35| ****0.75| ****1| ****400| ****10|
****VXm 15/35| ****1.1| ****1.5| ****500| ****13.5
****VXm 15/50| ****1.1| ****1.5| ****650| ****11**
※ suitable for dirty waste water
※ SAR 250 with grinder pumps (TRITUS)
TYPE| POWER (P2)| MAXIMUM FLOW RATE litres/min|
PREVALENCE MAX metres|
---|---|---|---|---
kW| HP
**TIGm 0.75| ****0.75| ****1.0| ****140| ****17.5**|
TIGm 1.1| **1.1| ****1.5| ****150| ****22.5
****TIGm 1.3| ****1.3| ****1.75| ****250| ****20.5**
※ suitable for sewage water
DIMENSIONS AND WEIGHT
TYPE | PORTS | kg |
---|---|---|
I | U ( 1) | S |
SAR 250 – TOP 3 |
DN 110
| 1¼”|
DN 50
| 49.7
SAR 250 – TOP 4| 1½”| 53.3
SAR 250 – TOP 5| 1½”| 54.3
SAR 250 – RXm 3| 1¼”| 50.6
SAR 250 – Dm 10| 1½”| 57.0
SAR 250 – Dm 20| 1½”| 57.0
SAR 250 – Dm 30| 1½”| 60.4
SAR 250 – RXm 3/20| 1¼”| 50.7
SAR 250 – ZXm 2/40| 1½”| 53.8
SAR 250 – VXm 10/35| 1½”| 58.2
SAR 250 – VXm 15/35| 1½”| 61.0
SAR 250 – VXm 15/50| 2″| 61.5
SAR 250 – TIGm 0.75| 1½”| 59.0
SAR 250 – TIGm 1.1| 1½”| 61.3
SAR 250 – TIGm 1.3| 1½”| 61.3
(1) Male threaded connection
KEY:
I collection pipe port
U discharge pipe connection
S ventilation pipe port
SAR 550
Lift and collection stations
INSTALLATION AND USE
The SAR 550 lift and collection stations are designed to handle clear water,
rainwater, or dirty water from civil and industrial drains, where the sewer
network is too far away or not accessible by gravity.
The SAR 550 stations are compact and easy to install on the floor or
underground, both indoors and outdoorsof residential buildings, offices,
public establishments, courtyards, and parking facilities, for sewage or
rainwater disposal.
COMPONENTS INCLUDED
※ 550 litres polyethylene tank with a non-driveable cover that can support
pedestrian traffic up to a maximum of 100 kg.
※ Two single-phase pumps (without float switches)pre-installed and already
connected to a controlpanel.
※ Standard 10-metres power cable .
※ Electrical panel (E2 model).
※ Three float switches with the following functions:
- Alternating activation of one of the two pumps
- Activation of the second pump at maximum level
- Shutdown of the pump at minimum level
AVAILABLE UPON REQUEST
※ SAR 550 lift station, equipped with two single-phase pumps, based on
yourspecific requirements.
※ Three-phase submersible pump.
OPTIONAL
※ Alarm kit (Code: KSKIT-ALLARME) equipped with electrical panel, self-powered
siren, and float
※ 300 mm extension kit (Code No. KSKIT-308MA) for installing the “SAR” tank at
greater depths
※ “SAR” Stations with check valve and ball valve in the discharge pipe
※ SAR 550 with drainage pumps
TYPE| POWER (P2)| MAXIMUM FLOW RATE [1] pump
litres/min| PREVALENCE MAX metres|
---|---|---|---|---
kW| HP
**TOP 4| ****0.75| ****1| ****320| ****12.5**|
**TOP 5| ****0.92| 1.25| 360| ****15
****Dm 10| ****0.75| ****1| ****300| ****15.5|
****Dm 20| ****0.75| ****1| ****250| ****19
****Dm 30| ****1.1| ****1.5| ****275| ****26**
※ suitable for clear wastewater
※ SAR 550 with VORTEX pumps
TYPE| POWER (P2)| MAXIMUM FLOW RATE [1] pump
litres/min
| PREVALENCE MAX
metres
|
---|---|---|---|---
kW| HP
**VXm 10/35| ****0.75| ****1| ****400| ****10|
****VXm 15/35| ****1.1| ****1.5| ****500| ****13.5
****VXm 10/50| ****0.75| ****1| ****550| ****8.5
****VXm 15/50| ****1.1| ****1.5| ****650| ****11
****BCm 10/50| ****0.75| ****1| ****600| ****11|
****BCm 15/50| ****1.1| ****1.5| ****750| ****14**
※ SAR 550 with grinder pumps (TRITUS)
TYPE| POWER (P2)| MAXIMUM FLOW RATE [1] pump litres/min| PREVALENCE MAX
metres
|
---|---|---|---|---
kW| HP
TIGm 0.75| 0.75| 1| 140| 17.5|
TRm 0.9| 0.9| 1.25| 170| 15
TRm 1.1| 1.1| 1.5| 140| 21.5
TRm 1.3| 1.3| 1.75| 220| 22.5
TRm 1.5| 1.5| 2| 270| 25
TRm 2.2 AP| 2.2| 3| 275| 35
※ suitable for sewage water
(*) On request “SAR” stations with coupling feet and guide pipes for pump
descent
DIMENSIONS AND WEIGHT
KEY:
I collection pipe port
U discharge pipe connection
S ventilation pipe port
SAR 550 | 50 Hz