PEDROLLO SAR 40 Lift and Collection Stations User Guide

July 18, 2024
pedrollo

SAR 40
Lift and collection stations

INSTALLATION AND USE

The SAR 40 lift and collection stations are designed to handle clear water, rainwater, and wastewater from household drains like washing machines, dishwashers, and sinks, especially in situations where connection to the main sewer system is impractical or impossible due to distance or gravity constraints. The SAR 40 stations are compact and easy to install in basements, single-residence garages, or even underground

COMPONENTS INCLUDED
※ 40 litres polyethylene tank with a non-walkable and non-driveable cover.
※ Single-phase submersible pump.
※ Standard 5-metres power cable .
※ Swing check valve for models with drainage pumps only (for clear wastewater).

AVAILABLE UPON REQUEST
※ SAR 40 lift station, equipped with a single-phase submersible pump with a float switch, based on your specific requirements.
※ 10-metres power cable.
※ Full-flow check valve (for external installation) designed for vortex and grinder pumps.

※ SAR 40 with grinder pump

TYPE| POWER (P2)| MAXIMUM FLOW RATE litres/min| PREVALENCE MAX metres|
---|---|---|---|---
kW| HP
**TRITUS-TX| ****0.55| ****0.75| ****90| ****11.5**|

※ Suitable for sewage

※ Start of production  06.2024

※ SAR 40 with drainage pumps

TYPE| POWER (P2)| MAXIMUM FLOW RATE litres/min| PREVALENCE MAX metres|
---|---|---|---|---
kW| HP
**TOP 1 -GM| ****0.25| ****0.33| ****160| ****6.0|
****
RXm 1 -GM| ****0.25| ****0.33| ****160| ****7.0**|

※ Suitable for clear wastewater

※ SAR 40 with vortex pumps

TYPE| POWER (P2)| MAXIMUM FLOW RATE litres/min| PREVALENCE MAX metres|
---|---|---|---|---
kW| HP
**TOP 2 VORTEX-GM| ****0.37| ****0.50| ****155| ****7.0|
****
TEX 2| ****0.37| ****0.50| ****220| ****8.3**|


※ Suitable for dirty waste water

DIMENSIONS AND WEIGHT

KEY:
I collection pipe connection
U discharge pipe connection
S ventilation pipe connection

TYPE I(1) PORTSU(1) S(1) h kg
SAR 40 – TRITUS-TX 1½” 1¼” ½” 335
SAR 40 – TOP 1-GM 305 14.3
SAR 40 – RXm 1-GM 15.2
SAR 40- TOP 2 VORTEX-GM 335 144
SAR 40 – TEX 2 15.0

EXAMPLES OF INSTALLATION

PEDROLLO SAR 40 Lift and Collection Stations - DIMENSIONS AND
WEIGHT1

SAR 100
Lift and collection stations

INSTALLATION AND USE
SAR 100 lift and collection stations are designed to handle clear water, rainwater, and wastewater from household drains like washing machines, dishwashers, sinks, and toilets, especially in situations where connection to the main sewer system is impractical or impossible due to distance or gravity constraints. The SAR 100 stations are compact and easy to install either on the floor or underground, both inside and outside of single or two-family homes.

COMPONENTS INCLUDED
※ 100 litres polyethylene tank with a non-walkable and non-driveable cover.
※ Single-phase submersible pump.
※ Standard 10-metres power cable.
※ Electrical panel (only for SAR 100-TIGm 1.1 and 1.3)

AVAILABLE UPON REQUEST

※ SAR 100 lift station, equipped with a singlephase submersible pump with a float switch, based on your specific requirements

※ SAR 100 with drainage pumps

TYPE| POWER (P2)| MAXIMUM FLOW RATE

litres/min

| PREVALENCE MAX

metres

|
---|---|---|---|---
kW| HP
**TOP 3| ****0.55| ****0.75| ****260| ****10.0**|


**RXm 3| ****0.55| ****0.75| ****220| ****11.5**|


**Dm 10| ****0.75| ****1.0| ****300| 15.5|
****
Dm 20| ****0.75| ****1.0| ****250| ****19.0**

※ SAR 100 with vortex pumps

TYPE| POWER (P2)| MAXIMUM FLOW RATE litres/min| PREVALENCE MAX metres|
---|---|---|---|---
kW| HP
**TOP 3-VORTEX| ****0.55| ****0.75| ****170| ****8.2|
****
RXm 3/20| ****0.55| ****0.75| ****240| ****9.5|
****
ZXm 2/30| ****0.55| ****0.75| ****320| ****12.5|
****
VXm 10/35| ****0.75| ****1.0| ****400| ****10.0**|

※ suitable for dirty waste water
※ SAR 100 with grinder pumps (TRITUS)

TYPE| POWER (P2)| MAXIMUM FLOW RATE litres/min| PREVALENCE MAX metres|
---|---|---|---|---
kW| HP
TIGm 0.55| 0.55| 0.75| 130| 14.5|


TIGm 0.75| 0.75| 1.0| 140| 17.5
TIGm 1.1| 1.1| 1.5| 150| 22.5
TIGm 1.3| 1.3| 1.75| 250| 20.5

DIMENSIONS AND WEIGHT

KEY:
I collection pipe port
U discharge pipe connection
S ventilation pipe port

TYPE| 1| PORTS
U(1)| S| 11| 12| kg
---|---|---|---|---|---|---
SAR 100 – TOP 3| DN 110| 1¼”| DN 50| 145| 100| 29.0
SAR 100 – RXm 3| 1¼”| 29.9
SAR 100- Dm 10| 1¼”| 36.3
SAR 100- Dm 20| 1¼”| 36.3
SAR 100-TOP 3-VORTEX| 1¼”| 29.1
SAR 100- RXm 3/20| 1¼”| 30.0
SAR 100- ZXm 2/30| 1¼”| 33.1
SAR 100- VXm 10/35| 1¼”| 37.5
SAR 100- TIGm 0.55| 1¼”| 38.2
SAR 100- TIGm 0.75| 1¼”| 38.3
SAR 100- TIGm 1.1| 1¼”| 40.6
SAR 100- TIGm 1.3| 1¼”| 40.6

(1) Male threaded connection

SAR 250
Lift and collection stations

PEDROLLO SAR 40 Lift and Collection Stations -
stations

INSTALLATION AND USE
SAR 250 lift and collection stations are designed to handle clear water, rainwater, and wastewater from household and civil drains like washing machines, dishwashers, sinks, and toilets, especially in situations where connection to the main sewer system is  impractical or impossible due to distance or  gravityconstraints. SAR 250 stations are compact and easy to install, suitable for floor or underground placement, both indoors and outdoors of multi-unit buildings.

COMPONENTS INCLUDED
※ SAR 250 polyethylene tank with a non-driveable cover that can support pedestrian traffic up to a maximum of 100 kg.
※ Single-phase submersible pump.
※ Electrical panel (only for SAR 250-TIGm 1.1 and 1.3).
※ Standard 10-metres power cable.

AVAILABLE UPON REQUEST
※ SAR 250 lift station, equipped with a sin-gle-phase submersible pump with a float switch, based on your specific requirements.
※ Three-phase submersible pump
※ Alarm kit (Code: KSKIT-ALLARME) equipped with electrical panel, self-powered siren, and float
※ 300 mm extension kit (Code No. KSKIT-308MA) for installing the “SAR” tank at greater depths
※ “SAR” Stations with check valve and ball valve in the discharge pipe.
※ SAR 250 with drainage pumps

TYPE| POWER (P2)| MAXIMUM FLOW RATE litres/min| PREVALENCE MAX metres|
---|---|---|---|---
kW| HP
TOP 3| 0.55| 0.75| 260| 10.0|
TOP 4| 0.75| 1.0| 320| 12.5
TOP 5| 0.92| 1.25| 360| 15.0
**RXm 3| ****0.55| 0.75| ****220| ****11.5|
Dm 10| 0.75| 1.0| 300| 15.5|
Dm 20| 0.75| 1.0| 250| 19.0
Dm 30| 1.1| 1.5| 275| 26.0**

※ suitable for clear wastewater

※ SAR 250  with VORTEX pumps

TYPE| POWER (P2)| MAXIMUM FLOW RATE litres/min| PREVALENCE MAX metres|
---|---|---|---|---
kW| HP
**RXm 3/20| ****0.55| ****0.75| ****240| ****9.5|
****
ZXm 2/40| ****0.55| ****0.75| ****400| ****11|
****
VXm 10/35| ****0.75| ****1| ****400| ****10|
****
VXm 15/35| ****1.1| ****1.5| ****500| ****13.5
****
VXm 15/50| ****1.1| ****1.5| ****650| ****11**

※ suitable for dirty waste water

※ SAR 250 with grinder pumps (TRITUS)

TYPE| POWER (P2)| MAXIMUM FLOW RATE litres/min| PREVALENCE MAX metres|
---|---|---|---|---
kW| HP
**TIGm 0.75| ****0.75| ****1.0| ****140| ****17.5**|


TIGm 1.1| **1.1| ****1.5| ****150| ****22.5
****
TIGm 1.3| ****1.3| ****1.75| ****250| ****20.5**

※  suitable for sewage water

DIMENSIONS AND WEIGHT

TYPE PORTS kg
I U ( 1) S
SAR 250 – TOP 3

DN 110

| 1¼”|

DN 50

| 49.7
SAR 250 – TOP 4| 1½”| 53.3
SAR 250 – TOP 5| 1½”| 54.3
SAR 250 – RXm 3| 1¼”| 50.6
SAR 250 – Dm 10| 1½”| 57.0
SAR 250 – Dm 20| 1½”| 57.0
SAR 250 – Dm 30| 1½”| 60.4
SAR 250 RXm 3/20| 1¼”| 50.7
SAR 250 – ZXm 2/40| 1½”| 53.8
SAR 250 – VXm 10/35| 1½”| 58.2
SAR 250 – VXm 15/35| 1½”| 61.0
SAR 250 – VXm 15/50| 2″| 61.5
SAR 250 – TIGm 0.75| 1½”| 59.0
SAR 250 TIGm 1.1| 1½”| 61.3
SAR 250 – TIGm 1.3| 1½”| 61.3

(1) Male threaded connection

KEY:
I collection pipe port
U discharge pipe connection
S ventilation pipe port

SAR 550
Lift and collection stations

INSTALLATION AND USE
The SAR 550 lift and collection stations are designed to handle clear water, rainwater, or dirty water from civil and industrial drains, where the sewer network is too far away or not accessible by gravity.
The SAR 550 stations are compact and easy to install on the floor or underground, both indoors and outdoorsof residential buildings, offices, public establishments, courtyards, and parking facilities, for sewage or rainwater disposal.

COMPONENTS INCLUDED
※ 550 litres polyethylene tank with a non-driveable cover that can support pedestrian traffic up to a maximum of 100 kg.
※ Two single-phase pumps (without float switches)pre-installed and already connected to a controlpanel.
※ Standard 10-metres power cable .
※ Electrical panel (E2 model).
※ Three float switches with the following functions:

  1. Alternating activation of one of the two pumps
  2. Activation of the second pump at maximum level
  3. Shutdown of the pump at minimum level

AVAILABLE UPON REQUEST
※ SAR 550 lift station, equipped with two single-phase pumps, based on yourspecific requirements.
※ Three-phase submersible pump.
OPTIONAL
※ Alarm kit (Code: KSKIT-ALLARME) equipped with electrical panel, self-powered siren, and float
※ 300 mm extension kit (Code No. KSKIT-308MA) for installing the “SAR” tank at greater depths
※ “SAR” Stations with check valve and ball valve in the discharge pipe

※ SAR 550 with drainage pumps

TYPE| POWER (P2)| MAXIMUM FLOW RATE [1]  pump litres/min| PREVALENCE MAX metres|
---|---|---|---|---
kW| HP
**TOP 4| ****0.75| ****1| ****320| ****12.5**|


**TOP 5| ****0.92| 1.25| 360| ****15
****
Dm 10| ****0.75| ****1| ****300| ****15.5|
****
Dm 20| ****0.75| ****1| ****250| ****19
****
Dm 30| ****1.1| ****1.5| ****275| ****26**

※ suitable for clear wastewater

※ SAR 550  with VORTEX pumps

TYPE| POWER (P2)| MAXIMUM FLOW RATE [1] pump

litres/min

| PREVALENCE MAX

metres

|
---|---|---|---|---
kW| HP
**VXm 10/35| ****0.75| ****1| ****400| ****10|
****
VXm 15/35| ****1.1| ****1.5| ****500| ****13.5
****
VXm 10/50| ****0.75| ****1| ****550| ****8.5
****
VXm 15/50| ****1.1| ****1.5| ****650| ****11
****
BCm 10/50| ****0.75| ****1| ****600| ****11|
****
BCm 15/50| ****1.1| ****1.5| ****750| ****14**

※ SAR 550 with grinder pumps (TRITUS)

TYPE| POWER (P2)| MAXIMUM FLOW RATE [1]  pump litres/min| PREVALENCE MAX

metres

|
---|---|---|---|---
kW| HP
TIGm 0.75| 0.75| 1| 140| 17.5|


TRm 0.9| 0.9| 1.25| 170| 15
TRm 1.1| 1.1| 1.5| 140| 21.5
TRm 1.3| 1.3| 1.75| 220| 22.5
TRm 1.5| 1.5| 2| 270| 25
TRm 2.2 AP| 2.2| 3| 275| 35

※ suitable for sewage water
(*) On request “SAR” stations with coupling feet and guide pipes for pump descent

DIMENSIONS AND WEIGHT

PEDROLLO SAR 40 Lift and Collection Stations -
Extension1

KEY:
I collection pipe port
U discharge pipe connection
S ventilation pipe port

SAR 550 | 50 Hz

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals