powerCON NAC3MX-W-TOP True Outdoor Protection IP65 Locking Male Cable Instruction Manual

July 17, 2024
powerCON

NAC3MX-W-TOP True Outdoor Protection IP65 Locking Male Cable

Specifications:

  • Rated IP: IP65

  • Compliance: IEC 60799, IEC 60320-1, UL 60320-1, CSA C22.2 No.
    60320-1

  • Ratings: 16A 250V AC (1.5 – 2.5 mm2), 20A 250V AC
    (16 – 12 AWG)

  • Approved Cables: H07RN-F, H05VV-F, SOOW, SJOOW

Product Usage Instructions:

Assembly Information:

  1. Place the bushing and chuck over the cable.

  2. Use cable lubricant for easier assembly.

  3. Separate the housing from the bushing with the cable remaining
    in the bushing.

  4. Prepare the cable as shown and slide it into the contacts,
    clamping with the screw.

Disassembly:

Open twist lock for disassembly.

Safety Information:

Caution: Do not expose the connection to
bending forces to ensure protection category.

Safety Warning: Replace the connector in case
of any broken parts or excessive wear and tear.

Application and Safety Instructions:

Assembly:

  • Use appropriate personal protective equipment when assembling
    and processing the product.

  • Neutrik components must only be assembled with designated and
    specified components.

  • Replacement parts are suitable only when used in combination
    with designated components.

Application:

  • The product is intended for installation in electronic
    equipment or similar devices.

  • Not for use in medical applications or potentially explosive
    environments.

  • Appliance couplers are not for use as climbing aids. Indoor use
    only.

Operation:

FAQ:

Q: What should I do if I encounter bending forces on the

connection?

A: Avoid exposing the connection to bending
forces to maintain the protection category. Do not attach loads to
the cable or allow free-dangling cable windings.

Q: Can I use the product in medical applications?

A: No, the product is not intended for use in
medical applications.

R
PRODUCT MANUAL powerCON® TRUE1® TOP | NAC3MX-W-TOP

1 APPLICATION & SAFETY INSTRUCTION

P IP 65 RATED
APPLICATION:
· The powerCON® TRUE1® system is certified as appliance couplers with breaking capacity according to IEC 60320-1, EN IEC 60320-1, UL 60320-1, CSA C22.2 No. 60320-1.
· It serves to supply power to an appliance and from an appliance to other equipment. · To be installed by qualified person only. · Appliance couplers acc. to IEC 60320-1 are suitable to be used in cord sets and interconnection cord
sets acc. to IEC 60799

POWER IN
APPLIANCE INLET NAC3MPX-TOP NAC3MPX-WOT-TOP

POWER OUT
APPLIANCE OUTLET NAC3FPX-TOP NAC3FPX-WOT-TOP NAC3FPX-ST-TOP

POWER IN / POWER OUT u Combination APPLIANCE INLET / APPLIANCE OUTLET NAC3PX- TOP

CONNECTOR NAC3FX-W-TOP
Products are in compliance with:

PLUG CONNECTOR NAC3MX-W-TOP
IEC 60320-1 EN IEC 60320-1

Ratings: Conductor cross section:

16A 250V AC 1.5 – 2.5 mm2

CONNECTOR NAC3FX-W-TOP

PLUG CONNECTOR NAC3MX-W-TOP

UL 60320-1 CSA C22.2 No. 60320-1

20A 250V AC 16 – 12 AWG

CABLE LIST
Approved cables: H07RN-F H05VV-F
Approved cables: SOOW SJOOW
BDA 542 V5

3 x 1.5 mm2
ü ü

3 x 2.5 mm2
ü

16/3 AWG
-S -S

14/3 AWG
-L -S

12/3 AWG
-L -L
ð
Page 1

R
PRODUCT MANUAL – powerCON® TRUE1® I NAC3MX-W-TOP

2 ASSEMBLY INFORMATION

A

40 – 50 mm

NAC3MX-W 12650

22050

P S JET E

i

22500

B

NAC3MX-W 12650 22050 22500

P S JET E

Place the bushing (1) and chuck (2) over the cable.
Important: Chuck and Bushing cannot be placed over the cable after the assembly of the insert.
i For easier assembly please use a cable lubricante. Recommendation: Wire Pulling Lubricant – LUB-I/0.95 from 3MTM
Separate the housing from the bushing (cable remain in bushing)

C

Place chuck over the cable.

D IEC 60320-1 EN IEC 60320-1

20 mm
[0.787″]

8 mm
[0.32″]

E IEC 60320-1
EN IEC 60320-1

PE 23 mm [0.9″]

N

L

Torx size

T8

Torque Value 0.7 Nm (6.2 inch pound / 0.52 lb.ft)

UL 60320-1 CSA C22.2 No. 60320-1

L

N

Prepare cable as shown. UL 60320-1 CSA C22.2 No. 60320-1

20 mm
[0.787″]

8 mm
[0.32″]

PE 23 mm [0.9″]

Slide the cable into the contacts and clamp with the screw with Torx size T8.

Wiring
L Þ N Þ
Þ

VDE brown blue green / yellow

UL black white green

BDA 542 V5

ð
Page 2

R
PRODUCT MANUAL – powerCON® TRUE1® I NAC3MX-W-TOP

F

Important:

Align rubber key

and latch.

NAC3MX-W 12650 22050 22500

P S JET E

1. Important: Push and turn simultaneously.
3.

Slide chuck onto insert (1) and then both into housing (2).
Important: Align the chuck by positioning the nose into keyway.

Torque Value 2.0 Nm

G

PRESS FIRMLY

Wrench size 13 mm

NAC3MX-W 12650

22050

P S JET E

22500

Slide the cable clamp (3) bushing up the cable and tighten it with the tool (4) as shown (5).
Important: Black O-ring to hide to achieve IP protection (6).
(Tool available: Art. No. HTAC)

3 FOR DISASSEMBLY
OPEN TWIST LOCK!
1. Press with screw driver to unlock 2. Turn bushing 360°. 3. Repat step 1 + 2 until bushing is unscrewed.

4 SAFETY INFORMATION

CAUTION

NAC3FXP -SW JET E
22050 LIECHTENSTEIN
FORCE

To ensure protection category, do not expose the connection to bending forces (e.g. do not attach loads to the cable, no free-dangling cable windings etc.).

1. 2.
BDA 542 V5

SAFETY WARNING For safety and certification reasons the connector must be replaced in case of any broken parts or excessive wear and tear.
ð
Page 3

R
PRODUCT MANUAL – powerCON® TRUE1® I NAC3MX-W-TOP
5 Application and Safety Instructions
A Assembly
l When assembling and processing the product, ensure the use of appropriate personal protective equipment.
l Neutrik components must only be assembled with designated and specified components. l Replacement parts are suitable only when used in combination with the designated
components. The product’s characteristics are guaranteed only in the intended combination. B Application
l The product is exclusively intended for installation in electronic equipment or similar devices. l The product is not intended for use in medical applications. l The product is not intended for use in potentially explosive or flammable environments. l Appliance couplers are not intended for use as climbing aids. Caution: Electrical hazards! l For indoor use only . C Operation
l Before plugging in, check the contact area for dry surfaces. l Product surfaces may cause burns at elevated ambient temperatures. Ensure the use of appropriate
protective equipment. l Neutrik products should only be combined with products from Neutrik Group brands.
D Cleaning
l Clean only with dry and lint-free materials or compressed air. l The product must not be cleaned while under load. The product may only be cleaned while it is not
connected to any voltage and without the use of cleaning agents.
E Damages
l Handle products with care. l In case of visible damages, check the suitability of the product for use.
6 More Information on the website
https://www.neutrik.com/en/product/nac3mx-w-top

Document No.: BDA 542 V5

Date:

2024-03-13

Neutrik AG I LI-9494 Schaan

www.neutrik.com

Data subject to change without prior notice. © 2024 NEUTRIK®. NEUTRIK®, powerCON are registered trademark of Neutrik AG. ALL RIGHTS RESERVED.

Page 4

A brand of the Neutrik Group

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals