- Input Impedance: 1M
- Output Impedance: 1k
- Current Consumption: 250mA
- Voltage: 9V DC (Center Negative)
- Dimensions: Width: 75 mm / 2.95, Length: 111 mm / 4.37, Height: 43 mm / 1.69
- Weight: 250 g / 0.55 lb
Warning:
The Hyper Luminal has a current draw of 250mA. Only use a regulated 9V DC adapter with a center-negative plug. Unregulated power supplies and/or higher voltages may result in suboptimal noise performance and even damage your unit, voiding the warranty.
Warranty:
To activate the warranty, register your product on: mypedal.darkglass.com and enter the serial number on the back of your pedal. Contact support@darkglass.com before shipping a product for warranty claims.
Disclaimer:
The manufacturer states that the product meets the requirements set by EN55013, EN55020, EN60555-2, EN60555-3, RoHS, WEEE standards. Specifications are subject to change without notice.
EMC / EMI Compliance:
This equipment complies with Class B Digital device standards and FCC rules to minimize interference. Follow installation instructions to prevent harmful interference to radio communications.
Product Usage Instructions
- Power Supply:
- Ensure to use a regulated 9V DC adapter with a center-negative plug. Using unregulated power supplies or higher voltages may damage the unit and void the warranty.
- Connections:
- Connect your instrument to the input jack and your amplifier or recording device to the output jack. Ensure all connections are secure before powering on the unit.
- Controls:
- Refer to the manual or online resources for detailed information on the controls and settings of the Hyper Luminal Enhancer Series.
- Maintenance:
- Keep the unit clean and free from dust or debris. Avoid exposing it to extreme temperatures or moisture. Regularly check connections for any signs of wear or damage.
FAQ
-
Q: What should I do if my hyper-luminal unit stops functioning?
- A: Check the power supply connections, ensure correct voltage and polarity. If issues persist, contact customer support for assistance.
-
Q: Can I use a different power adapter with the Hyper Luminal?
- A: No, only use a regulated 9V DC adapter with a center-negative plug to avoid damaging the unit and voiding the warranty.
Specs
Controls
- Blend: Mixes the clean and effected signals. Unlike our distortions, it is placed before the Output control. So theHyper Luminal can also be used as a transparent booster with this control at minimum.
- Time: Sets the time constants (Attack and Release). You can use the Darkglass Suite to fine-tune and custom map the time constants, you can also assign different behaviors for each Mode.
- Output: Sets the overall output volume of the unit.
- Compression: Sets the overall amount of compression. This control also affects the internal makeup gain.
- Ratio: Adjusts the amount of compression.
- Mode: Select the unit’s Mode (BUS, FET, or SYM)
Technical Specifications
- Input Impedance: 1MΩ
- Output Impedance: 1kΩ
- Current Consumption: 250mA
- Voltage: 9V DC (Center Negative)
Dimensions
- Width: 75 mm / 2,95″
- Length: 111 mm/ 4,37″
- Height: 43 mm / 1,69″
- Weight: 250 g / 0,55 lb
Warning
The Hyper Luminal has a current draw of 250mA. Only use a regulated 9V DC adapter with a center-negative plug.Unregulated power supplies and/or higher voltages may result in suboptimal noise performance and even damage to your unit, voiding the warranty.
Warranty
To activate the warranty, we encourage you to register your product on:
http://mypedal.darkglass.com
and enter the serial number on the back of your pedal. Please contact usvia
email at support@darkglass.com before shipping
a product to us.
Disclaimer
In the interest of continuous improvement, specifications are subject to change without notice. If you have any questions, please don’t hesitate to contact us at www.darkglass.com The manufacturer claims that the above product fulfils the requirements as set by EN55013,EN55020, EN60555-2, EN60555-3, RoHS, WEEE. 1176®, and SSL® are registered trademarks of their respective companies. Names of factory modes are intended for descriptive purposes only and should not be construed as an endorsement or affiliation with the companies or products named. All product names are trademarks of their respective owners, which are in no way associated or affiliated withDarkglass Electronics.
EMC / EMI
This equipment has been tested and found to comply with the limits for a Class B Digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmfulinterference to radio communications. There is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning equipment off and on, the user is encouraged to try to correct the interference by one or more of the followingmeasures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
https://www.instagram.com/darkglasselectronics/
https://www.facebook.com/darkglasselectronics
https://www.youtube.com/user/darkglasseffects/videos
References
- Darkglass Electronics - Login
- Darkglass Electronics - Login
- Darkglass Electronics
- Darkglass Electronics
- Careers – Darkglass Electronics
- Creations – Darkglass Electronics
- Dealers – Darkglass Electronics
- Hyper Luminal Manual – Darkglass Electronics
- Privacy Policy – Darkglass Electronics
- Suite – Darkglass Electronics
- Login • Instagram
- Revolve Studio • Custom Web Design Services in Helsinki
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>