UFO MicroLED 5000T Illuminator User Guide
- July 12, 2024
- UFO
Table of Contents
- UFO MicroLED 5000T Illuminator
- INTRODUCTION
- MODELS COVERED BY THIS USER GUIDE UFO MIC5000T DMX
- INSTALLATION
- OPERATION
- SETTING THE DMX ADDRESS
- MAINTENANCE AND SAFETY GUIDANCE
- MAINTENANCE LOG
- TROUBLESHOOTING
- TECHNICAL SPECIFICATION
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
UFO MicroLED 5000T Illuminator
Product Specifications
- Product Name: MicroLED 5000T Illuminator
- Model: UFO MIC5000T DMX
- Power Supply: 12V Power Supply Unit or 12V Constant Voltage Driver
- DMX Data Connection: RJ45 sockets at the rear of the Illuminator
Operation
DMX Data Connection: Connect the DMX data cables to the RJ45 sockets at
the rear of the Illuminator following the pin details provided in the manual.
Make sure to terminate the DMX universe with a 120-ohm resistor for optimal
performance.
FAQ
Q: Can the LED array and heatsink be replaced?
A: Yes, the LED array and heatsink in this illuminator can be replaced
when they reach the end of their life. Contact UFO for specific replacement
details.
PLEASE READ THIS USER GUIDE BEFORE INSTALLING, OPERATING OR PERFORMING MAINTENANCE ON THE ILLUMINATOR UNIT
INTRODUCTION
- Thank you for purchasing this UFO illuminator/luminaire.
- To ensure that the illuminator is set up optimally and gives a long service life, please read this user guide before installing, operating or performing any maintenance on the unit.
- Please keep this User Guide for future reference. This User Guide is laid out in three sections
- Installation -details on how to connect your luminaire
- Operation – details how to programme and set up your luminaire
- Maintenance – maintenance log, troubleshooting guide, technical specification
MODELS COVERED BY THIS USER GUIDE UFO MIC5000T DMX
IMPORTANT
- This product must be installed in accordance with the applicable installation code, by a person familiar with the construction and operation of the product, and the hazards involved.
- These illuminators are not mains dimmable.
- The LED array and heatsink in this illuminator can be replaced when it reaches end of life. Contact UFO for details.
- Type Y Attachment: If the external flexible cable or cord of this luminaire or associated
- PSU/driver is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person to avoid a hazard.
- Location: Do not locate this illuminator closer than 200mm from any flammable surface.
- Clearance / Ventilation: It is imperative that a gap of 200mm is left around the unit. This is to allow air to circulate and prevent overheating. The location must have free ventilation and must not have an ambient temperature higher than that specified for the luminaire.
- Mounting: This luminaire comes with an integral mounting plate for securing the unit to a vertical or horizontal surface. Refer to the instruction sheet supplied with the plate.
- Warning: Never look directly at the luminaire through the fiber port of the illuminator.
- Warning: The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 2.7 metres is not expected.
INSTALLATION
MOUNTING
This luminaire is supplied with a separate mounting plate. If using the
mounting plate refer to the fitting instructions supplied with it.
POWER SUPPLY REQUIREMENTS
This luminaire is powered by a 12V Power Supply Unit or 12V Constant Voltage
Driver. Remove the PSU/driver from its box.
Connect the jack plug into the socket in the back, and the illuminator is now
ready for connection.
OPERATION
CONNECTION
There are 3 connections required – the fiber port, the mains supply and the
DMX cable. The fiber port should be connected first. Connect and secure the
fiber optic connector into the silver collar and secure using the M5 locking
screw
RJ45 DMX data sockets are provided at the rear of the Illuminator.
DMX data connection details are as follows.
Note:
A termination resistor of 120Ώ should be fitted at the end of DMX universes
across DMX + and DMX-. Although systems having a few devices and short cable
runs may work well without, it is always recommended that a termination plug
be fitted
Plug the mains plug into the electrical supply socket. Switch on power the led
Indicator will illuminate and the Illuminator will start up automatically.
Before connecting up to DMX control it is recommended that the Illuminator be
tested in Standalone manual control
STANDALONE CONTROL
To enter Standalone Mode switch DIP Switch 10 ON (down) and the twinkle wheel
will turn slowly. The Illuminator can now be controlled using the DIP switch
on the rear as shown in the following table. Colors can be mixed by switching
ON different colors at the same time
WHITE COLOURS
In the table above, dip switches 7 and 8 are white only. 9 is rainbow white
(white with varying colors)
REMOTE DMX CONTROL
Now set the DMX address and connect up the Illuminators with the Remote
Controller using the RJ45 sockets provided on the back of the Illuminator – it
doesn’t matter which socket is used.
SETTING THE DMX ADDRESS
The DMX address of each illuminator is set manually using the DIP switch
accessible on the rear panel. Each switch number 1-9 indicates a binary number
which added together make up the DMX address.
Alternatively use the online calculator from:
http://www.sabretechnology.co.uk/calc.asp
Example on right
- – On
- – Off
- – Off
- On
- – Off
- – On
- – On
- – Off
- – Off
- – Off
= Address 105
Each illuminator occupies 5 DMX channels see Channel Table below
The Twinkle wheel oscillates backwards and forwards avoiding the open segment. When Channel 5 value is set to 0 the Twinkle wheel will stop opposite the open segment to give full light.
Please note that Canary (bright yellow) is difficult to achieve using the composite colors, and as such is a poor match.
MAINTENANCE AND SAFETY GUIDANCE
MAINTENANCE
To ensure a long working life and the safe, reliable operation of the
illuminator, it is very important to maintain it properly and ensure it is
installed in an appropriate and safe location.
Before performing any maintenance on the illuminator it should be disconnected
from the power supply and allowed to cool down.
- The illuminator vents should be blown out with compressed air at least every 12 months, or more often if located in a dusty environment.
- After the illuminator has been installed, check the vents to ensure they are clear of dust and debris. Blow out with compressed air if required.
- The body of the illuminator can be cleaned using a soft damp cloth. Do not use any abrasives on the unit.
Note that a record of all maintenance MUST be kept in the table below, indicating what maintenance was undertaken. This must be dated and is required for warranty purposes.
SAFETY GUIDANCE
- A gap of 200mm (8”) MUST be left around the unit. This is to allow air to circulate and prevent overheating. The location must have free ventilation and must not have an ambient temperature higher than that specified for the luminaire.
- The outer body of the illuminator may become hot – keep away from all combustible materials and DO NOT locate this illuminator within 200mm (8”) of any flammable surface.
- The illuminator must not be run without the fiber optic harness fitted.
MAINTENANCE LOG
TROUBLESHOOTING
TECHNICAL SPECIFICATION
United Kingdom • United States • Germany • Europe • UAE
Universal Fiber Optics Ltd Home Place \ Coldstream TD12 4DT \ UK +44 (0)1890
883416 www.ufo.lighting
Universal Fiber Optics USA LLC 1749 Northgate Blvd Sarasota \ FL34234 \ USA
941-343-8115
www.fiberopticlighting.com
UFO Licht GmbH
Friendsfactory AG \ Gutenbergstraße 1 85737 Munchen \ Deutschland +49 (0)9491
955880 www.ufo-licht.de
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>