BioLite Charge 100 Max Power Bank Instruction Manual
- July 11, 2024
- BioLite
Table of Contents
BioLite Charge 100 Max Power Bank
ANATOMY
-
Wireless Charging Pad
Up To 15W. Works with MagSafe. -
Action Button
Wake the unit, check status, and change sync behavior. -
Charge Level Indicators
Battery level plus temperature alerts. -
Wireless Charging Indicator
PORTS
USER INTERFACE
Action Button
- Press to initiate charge out and display charge level
- Hold to stop charge out
Charge Level Indicators
- During charge in, the highest indicator will blink to indicate the amount of charge left.
- First indicator flashing signals 0% charge. Connect to a charging source.
- All indicators flashing signals an over or under temperature warning. Allow your device to return to operating temperature (see VII).
Wireless Charging Indicator
- Pulses white when wireless charging is active
- Fast flash means Wireless Protection is enabled. This occurs when a foreign object is detected or the device temperature too high.
CHARGING YOUR DEVICES
Multi-Device Charging
Charge 100 Max can accommodate up to 120W of simultaneous charging. Example scenario:
CHARGING YOUR POWER BANK
PRO TIP
If your laptop came with a USB-C charger it can be used to fast-charge your Charge 100 Max.
PASS-THROUGH CHARGING
Charge 100 Max can simultaneously accept charge from a dedicated source and provide charge out to connected devices. Note the maximum charge-in power is 65W. So if connected devices are drawing more than the charge supply, the internal battery will eventually drain to 0%.
BI-DIRECTIONAL DEVICES
In normal use, Charge 100 Max will charge automatically from a standard wall charger with no interaction required.
- Some USB-C PD-enabled devices have ports that can act bi-directionally as either a SOURCE (providing charge output) or a SINK (accepting charge input). In some rare occasions, you may want to charge up your power bank from a laptop, tablet, power bank or power station that is acting as a bi-directional device. 0:809
- The C1 USB-C PD port on Charge 100 MAX will default to SOURCE or CHARGE OUT when connected to another bi-directional device such as the BioLite BaseCharge Power Station.
- To allow the C1 port to accept a charge FROM a bi-directional device, double press the Action Button. To return the C1 port to provide a charge TO a bi-directional device, double pres the Action Button again.
TECHNICAL SPECIFICATIONS
Charge 100 Max 91.25 Wh Power Bank
BATTERY
- 91.25Wh (18.25V, 5,000mAh).
- Eq. Capacity: 3.65V, 25,000mAh
INPUTS
- USB-C PD, up to 65W
CHARGE TIME
- 1.5 h by 65W USB-C PD
- (SOLD SEPARATELY)
OUTPUTS
- (2x) USB-C PD
- 100W, 5V/3A, 9V/3A, 12V/3A
- 15V/3A, 20V/5A
- (1x) USB-C
- 15W, 5V/3A
- (1x) USB-A
- 15W, 5V/3A
Wireless Pad
- Up to 15W. Works with MagSafe.
TOTAL OUTPUT POWER
- 120W
- WEIGHT
- 580 g (20.5 oz)
DIMENSIONS
- 5.5 x 4.4 x 1.4 in
- 140 x 112 x 35 mm
SAFETY & COMPLIANCE
- Battery operating range: -4°F to 104°F (-20°C to 40°C)
- Use and recharge at least once every 6 months
- Do not disassemble
- Do not expose to liquids
- Avoid dropping
- Do NOT insert foreign objects into any of the ports
- Do NOT use near flames or cooking
- Observe all input/output ratings and use only appropriate cables & connectors
- Use included BioLite USB-C cable. BioLite does not guarantee performance or compatibility with 3rd party devices or accessories.
FCC Statement
FCC COMPLIANCE STATEMENT
This device complies with part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference 1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party\ responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.f this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirements. The device can be used in portable exposure conditions without restriction.
FCC ID: 2A3GZCBD
IC: 23414-CBD
To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be installed and operated with a minimum distance between 0cm the radiator and your body. Use only the supplied antenna.
IC CAUTION
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference, including interference that may cause undesired operation of the device.
EU COMPLIANCE STATEMENT
BioLite Inc. hereby declares that this device is in compliance with the essential requirements and other relevant provisions of the R&TTE Directive. A copy of the EU Declaration of Conformity is available online at bioliteenergy.com/euro-compliance. BioLite’s EU representative is Global VAT Compliance BV, VAT no. – NL822312852B01, Loire 192, 2491AM, The Hague, Netherlands. PROP 65
- Warning: Cancer and Reproductive Harm
- www.P65Warnings.ca.gov
IMPORTANT: BEFORE YOUR FIRST USE
-
Charge To Full Before Using Or Storing
This will help prolong the life of the battery. -
Register Your Charge 100 Max & Receive A Third Year Of Coverage On Us
Your serial number is required for registration and is located on the back of your product.
BioLite Warranty – US, Canada & EU
BioLite Charge 100 Max has a 2-year limited warranty. Should this product not function properly under normal use within 2 years of purchase, contact BioLite (bioliteenergy.com/contact) to complete the required troubleshooting process. If this process determines that the product has an irreparable manufacturing flaw, you will be directed to return the unit to the point of purchase for a full replacement at no charge. This warranty does not cover any damage or malfunction arising from misuse, improper maintenance, negligence, normal wear and tear, or accident. See reverse for international warranty policies.
For Setup, Tips and More:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>