BioLite BaseCharge 1500 Rechargeable Power Station Instruction Manual

June 4, 2024
BioLite

BioLite-LOGO

BioLite BaseCharge 1500 Rechargeable Power Station

BioLite-BaseCharge-1500-Rechargeable-Power-Station-
PRODUCT

ANATOMY

BioLite-BaseCharge-1500-Rechargeable-Power-Station-1

INTRODUCTION
The BaseCharge 1500 power station* is a li-ion (NMC) battery storage device. For power output BaseCharge 1500 includes a 110 V AC pure sine wave inverter for sensitive devices, as well as a number of DC ports including a regulated 12 V cigarette lighter, USB-A and USB-C ports, as well as wireless charging on the top deck of the unit. These ports can be used to power most indoor 110V appliances and small electrical devices. For charging inputs they include the HPP 110 V AC power supply unit and solar input capabilities. The BioLite SolarPanel 100 is recommended.
NOTE: The “1500” relates to the total watt-hour capacity of the power station, which is 1520.64 watt-hours.

TECHNICAL SPECIFICATIONS

BATTERY
1520.64 Wh (21.6 V, 70.4 Ah), Li-Ion (NMC)

INPUTS
Wall/Solar Input (HPP), 400 W (10-30 V DC, 20 A max) USB-C PD, 100 W

CHARGE MANAGEMENT
Maximum Power Point Tracking (MPPT)

AC OUTPUTS

  • US: (3x) 110 V, Pure Sine Wave, 1200 W
  • UK/EU/NZ/AUS: (3x) 230 V, Pure Sine Wave, 1200 W 2,400 W Surge Plug types
    • United States (Type A)
    • United Kingdom (Type G)
    • Europe (Type C)
    • New Zealand & Australia (Type I)

WIRELESS OUTPUT
10 W Wireless Charger

DC OUTPUTS

  • (1x) 12 V Carpo rt Output: 120 W
  • (2x) 12 V DC Barrel Ports: 120 W. 5.5 mm OD / 2.1 mm ID

CYCLE CAPACITY

80% capacity after 500 full charge cycles

USB OUTPUTS

  • (2x) USB-A: 5 V / 2.4 A
  • (2x) USB-C: 5 V / 3.0 A
  • (1x) USB-C PD: 5 V, 9 V, 12 V, 20 V / 5 A (100 W)

CHARGE TIME TO 80%

  • Included AC Wall Adapter: 13.5 hours
  • Included AC Wall Adapter + USB-C PD: 8 hours
  • Peak Input 4x SolarPanel 100: 4 hours

SHELF LIFE
Recharge every 6 months to prolong life 36 months storage capability

DIMENSIONS

  • 14.4 x 12.2 x 8.2 in
  • 367 x 310 x 209 mm

WEIGHT

  • 26.5 lbs
  • 12.1 kg

IN THE BOX

  • BaseCharge 1500 Power Station
  • Instruction Manual
  • 120 W AC Wall Adapter

WARRANTY

FOR CUSTOMERS IN THE UNITED STATES, CANADA, UK AND EU: BaseCharge has a 2 year limited warranty. Should this product not function properly under normal use within 2 years of purchase, contact your original point of purchase to complete the required troubleshooting process. If you purchased your product through Amazon or BioLiteEnergy.com, contact BioLite (bio liteenergy. com/contact) to complete the required troubleshooting process. If this process directed to return the unit to the point of purchase for a full replacement at no charge. This warranty does not cover any damage or malfunction arising from misuse, improper maintenance, negligence, normal wear and tear, or accident.
FOR ALL OTHER CUSTOMERS: Please contact your local supplier to obtain information regarding the applicable warranty for BioLite products in your BioLiteEnergy.com/International.

PORT OVERVIEW

BioLite-BaseCharge-1500-Rechargeable-Power-Station-2

POWERING A DEVICE

  1.  Plug in device to the corresponding port (FIG 10.1).
  2.  Press port activation button. The Port Indicator Light will turn to green (FIG 10.2) indicating “ON”.
  3.  The Easy-Read LCD Display will indicate the output wattage, and runtime until the BaseCharge is empty (FIG 10.3).
  4.  IMPORTANT: Press Port Activation Button to turn off port when not in use. This will help conserve power.

PORT INDICATOR LIGHTS BEHAVIOR

BioLite-BaseCharge-1500-Rechargeable-Power-Station-6

WIRELESS CHARGING

The base charge includes wireless charging for compatible devices. Put your wireless charging-compatible device on the top of the base charge, covering the wireless charging icon. Note that only one device can charge at a time. If the screen is not on, press any Port Activation Button to wake up the BaseCharge. Confirm the BaseCharge is displaying the wireless charging icon on the Easy-Read LCD screen to ensure your device is charging. The wireless charging will stop when the device is 100% charged or removed from the top deck.BioLite-BaseCharge-1500-Rechargeable-Power-
Station-7

EASY-READ LCD DISPLAY

BioLite-BaseCharge-1500-Rechargeable-Power-Station-8

  1.  Hours To Empty/Hours To Full: If input watts exceed output watts, the user interface will display “Hours To Full.” Conversely, if output watts exceed input watts, user interface will display “Hours To Empty.”
  2.  State Of Charge: Displays percentage battery remaining.
  3.  Output Wattage: Displays output wattage via USB-A, USB-C, USB-C PD, DC, AC and wireless charging.
  4.  Input Wattage: Displays input wattage via solar, USB-C PD, AC or a combination of the above if charging from multiple sources.
  5.  Error Code Icon: Indicates an error has occurred and you should check the Message Center for additional context.
  6.  Over Temperature Icon: BaseCharge is too hot. Cover your unit if in direct sunlight or take it indoors.
  7.  UnderTemperature Icon: BaseCharge is too cold. Take BaseCharge indoors.
  8.  Display: Turn display on and off.
  9.  Message Center & Energy Odometer: Displays status of unit, additional context for error codes or wattage consumed.
  10.  Wireless Charging Icon: Indicates that a device is actively charging on the Wireless Charging Pad.
  11.  See/Reset WH Used: Press to change Message Center to display watt-hours used since last reset. Press and hold to reset Energy Odometer.

ERROR CODES

HOT TEMPERATURE GAUGE
BaseCharge is getting hot. Turn off ports by pressing the button above each active port.

COLD TEMPERATURE GAUGE
BaseCharge is cold. Total capacity will be reduced until the temperature increases. Please bring inside.

RED TRIANGLE
Error. User Interface will notify you of the type of error.

To view the complete list of errors and their resolutions, scan the code to the right or visit BioLite.Help/BaseCharge1500

RESETTING YOUR BASE CHARGE

In very rare occasions, the BaseCharge may experience an error that causes the Easy-Read LCD display to become unresponsive. If this occurs, reset your BaseCharge to resume normal operation. To reset your BaseCharge, hold the DISPLAY button for 10 seconds.BioLite-BaseCharge-1500-Rechargeable-Power-
Station-11

CHARGING THE BASE CHARGE

There are three (3) ways to charge the BaseCharge 1500:

FROM A WALL OUTLET
Plug included AC adapter into the “SOLAR PANEL/CHARGER” PORT and indicator light will slowly pulse green. Charges to 80% in about 12.5 hours.

FROM USB-C
Plug USB-C cord (sold separately) into port and indicator light will slowly pulse green. Charges to 80% in about 15 hours.

FROM USB-C + WALL OUTLET
Plug included AC adapter into the “SOLAR PANEL/CHARGER” PORT and indicator light will slowly pulse green. Also plug USB-C cord (sold separately) into port and indicator light will slowly pulse green. Charges to 80% in about 8 hours.

RECHARGING FROM EMPTY
When the BaseCharge has been completely discharged (0%), and has been plugged into a power source, either solar or AC adapter, the ports will remain inactive until the state of charge has exceeded 1% . At that point, ports may be activated if needed.

SOLAR CHARGING

Maximize your input by connecting up to four (4) 100 W 12 V solar panels such as the BioLite SolarPanel 100. Connect to the BaseCharge using a 4×1 Chaining Adapter (sold separately).

CHARGING FROM SOLAR
Connect to HPP input via an HPP plug and indicator light will slowly pulse green. The BaseCharge is compatible with 12 V solar panels up to 400 W input. MC4 to HPP adapter sold separately for other solar panel brands. Charges fully at 400 W (4 panels) in about 4 hours (weather, angle and azimuth dependent ).BioLite-BaseCharge-1500-Rechargeable-Power-
Station-16

STORAGE & OPERATIONAL TEMPERATURES

LONG-TERM STORAGE
Ensure BaseCharge is ready to use by regularly inspecting the state of charge and topping up using the AC charger or solar input. If not in use for 12 months, continue to check the battery state of charge and top up every 3 – 4 months. *Ambient AC Load: The inverter for the 110 V AC ports has an ambient load of 10-15 W when the port is ON and not in use. Please deactivate all ports when the BaseCharge is not in use to reduce the drain on the battery.

OPERATIONAL TEMPERATURE RANGE

The BaseCharge Power Station operates best in temperatures between 30°F – 100°F (0°C – 37°C).

In cold temperatures ( <30°F/0°C): The
BaseCharge will have a reduced capacity while operating. Please keep insulated when using in outdoor, cold operation while keeping ventilations ports clear.

In hot conditions ( >100°F/37°C): If overheating, the BaseCharge will have a warning indicator. Please, do one or all of the following to allow the unit to cool:

  • Discontinue operation
  • Remove from direct sunlight
  • Ensure ventilation ports are not obstructed

WARNINGS

  • DO NOT insert foreign objects into ports or ventilation holes. Do not block ventilation holes.
  • DO NOT tamper with or open the outer casing.
  • DO NOT operate in wet or dusty conditions.
  • DO NOT stack objects on top of unit.
  • DO use and store in the upright position only

FREQUENTLY ASKED QUESTIONS

  • Q: Is this unit pure sine wave?
    A: Yes. The unit will not disrupt operation of appliances needing a pure sine wave, like a laptop.

  • Q: Can I use the BaseCharge unit while it is solar charging?
    A: Yes.

  • Q: Can I power an AC unit or heater?
    A: BioLite does not recommend that the BaseCharge power AC units or space heaters.

  • Q: Does BioLite BaseCharge 1500 work with non-BioLite solar panels?
    A: Yes, the BioLite BaseCharge 1500 can work with standard 12 V solar panels. It is not compatible with higher-voltage panels. If your non-BioLite panel utilizes an MC4 cord, note that the BioLite MC4-to-HPP adapter cord will be required for use (sold separately).

  • Q: Can I jump start a car?
    A: No. The BaseCharge is not the appropriate voltage to jump a standard lead acid vehicle battery.

  • Q: Can BaseCharge be stored outside?
    A: No. The unit should be stored inside in a cool, dry location. Do not expose your unit to extreme temperatures or moisture.

  • Q: Can I chain multiple BaseCharges together?
    A: BioLite does not recommend chaining BaseCharge units together.

  • Q: How can I estimate how long BaseCharge will power a device I want to use?
    A: The Easy-Read Smart Dashboard will calculate in real time the remaining hours left in the unit depending on level of charge, number of devices running, and if there is any power in. For more information on how to understand your power estimates, watch our video tutorials at BioLite.Help/BaseCharge1500.

  • Q: How many devices can I charge wirelessly at once?
    A: One device at a time can be charged wirelessly. The device must be directly on top of the wireless charging icon to receive a charge.

  • Q: What does the surge rating mean in the tech specs?
    A: Many devices that use a compressor or electric motor need a momentary spike in wattage to initiate the device. It then settles down to a lower, operational wattage. The BaseCharge can accommodate those “start-up” wattages with the surge capacity feature, but cannot sustain that surge wattage for longer periods of time.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BioLite User Manuals

Related Manuals