HAMPTON BAY HBLG5000 Room Air Conditioner Owner’s Manual

July 11, 2024
HAMPTON BAY

HAMPTON BAY HBLG5000 Room Air Conditioner

Product Information

Specifications:

  • Model: LG HBLG5000
  • Manufacturer: LG Electronics
  • Parts Compatibility: Genuine replacement parts available
  • Window Requirements: Detailed in manual
  • Electrical Data: Provided in manual

Product Usage Instructions

Safety Precautions:

Before operating the air conditioner, read and understand all safety precautions outlined in the manual. Some key safety points include:

  • Proper installation with assistance due to product weight
  • Avoid sharp edges
  • Do not operate with wet hands or in damp environments
  • Avoid directing air flow at room occupants only

About the Controls on the Air Conditioner:

The manual provides detailed information about the controls on the air conditioner, including air direction settings and care and maintenance instructions.

Features and Installation:

Learn about the features of the air conditioner and the installation requirements, such as window specifications and electrical data.

FAQ

  • Q: Where can I find the model and serial numbers of the air conditioner?
    • A: The model and serial numbers are located on a label on the side of each unit. You can also write them down in the space provided in the manual.
  • Q: What should I do if I encounter abnormal operation of the air conditioner?
    • A: Refer to the troubleshooting tips in the manual before calling for service. Many common problems can be resolved without professional assistance.
  • Q: Can I clean the air filter myself?
    • A: When removing the air filter, avoid touching the metal parts of the unit. Switch off the unit and unplug it before cleaning to prevent electric shock.

FOR YOUR RECORDS

Write down the model and serial numbers here:

  • Model #
  • Serial #

You can find them on a label on the side of each unit.

  • Dealer’s Name
  • Date Purchased
  • Staple your receipt here for proof of purchase.

READ THIS MANUAL

Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You’ll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all.

CAUTION

  • Contact an Authorized Service Center for repair or maintenance of this unit. Call 1-800-243-0000 to locate the nearest ASC.
  • The air conditioner is not intended for use by young children or invalids without supervision.
  • Young children should be supervised to ensure that they do not play with the air conditioner

Safety Precautions

To prevent injury to the user or other people and property damage, follow these instructions.

  • Incorrect operation due to ignoring instructions will cause harm or damage. The seriousness is classified by the following indications.
  • Because of the weight of the product, it is recommended that you have a helper to assist in the installation.
  • Use Caution! Sharp Edges!

WARNING This symbol indicates the possibility of death or serious injury.
CAUTION This symbol indicates the possibility of injury or damage to properties only

The meanings of symbols used in this manual are as shown below.

WARNING

Caution

About the Controls on the air conditioner

The controls will look like one of the following

Controls

FOR NORMAL COOLING

  1. Turn the operation switch to the High Cool or the Low Cool setting.
  2. Set the thermostat control to the desired temperature mark (the mid-point is a good starting position). If the room temperature is not satisfactory after a reasonable time, adjust the control to a cooler or warmer setting, as appropriate.

FOR MAXIMUM COOLING

  1. Turn the operation switch to the High Cool setting.
  2. Set the thermostat control to the largest temperature mark.

FOR QUIETER OPERATION

  1. Turn the operation switch to the Low Cool setting.
  2. Set the thermostat control as needed.

CAUTION

When the air conditioner has performed its cooling operation and is turned off or set to the fan position, wait at least 3 minutes before resetting to the cooling operation again.

Air Direction

  • ADJUSTING THE AIR DIRECTION USING THE HORIZONTAL AIR-DEFLECTOR CONTROL

Using the control tabs, the air flow can be directed to the left, right, straight ahead, or any combination of these directions.

Care and Maintenance

TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET.

TO CLEAN FILTER

The air filter will become dirty as it removes dust from the inside air. It should be washed at least every 2 weeks. If the air filter remains full of dust, the air flow will decrease and the cooling capacity will be reduced, possibly damaging the unit.

  1. Pull the inlet grille forward and pull out the air filter. (Fig. 1)
  2. Wash the air filter in warm 104°F (40°C) water.

Be sure to shake off all the water before replacing the filter.

CLEANING THE AIR CONDITIONER

  • The front grille and Inlet grille may be wiped with a cloth dampened in a mild detergent solution. (Fig. 2) The cabinet may be washed with mild soap or detergent and lukewarm water, then polished with Liquid Wax for Appliances.
  • To ensure continued peak efficiency, the condenser coils (outside of unit) should be checked periodically and cleaned if clogged with soot or dirt from the atmosphere.

HOW TO REMOVE THE FRONT GRILLE

  1. Remove the thermostat knob and the operation knob by pulling.
  2. Remove the screw securing the Front Grille. (Fig. 3)
  3. Push the grille up from the bottom and pull the top of the grille away from the case as the top tabs lift out of their slots. (Fig. 4)

Features and Installation

Learning parts name prior to installation will help you understand the installation procedure.

Features

  1. CABINET
  2. HORIZONTAL AIR DEFLECTOR
  3. COOL AIR DISCHARGE
  4. FRONT GRILLE
  5. INLET GRILLE
  6. AIR FILTER
  7. KNOBS
  8. AIR INTAKE
  9. UPPER GUIDE

Window Requirements

NOTE: All supporting parts should be secured to firm wood, masonry, or metal.

  1. This unit is designed for installation in standard double-hung windows with actual opening widths of 22″ to 36″. The upper and lower sash must open sufficiently to allow a clear vertical opening of 13″ from the bottom of the sash to the window stool.
  2. If a storm window presents interference, fasten a 2″ wide wood strip to the inner window sill across the full width of the sill. The wood strip should be thick enough to raise the height of the window sill so that the unit can be installed without interference by the storm window frame. See Fig. 5-2. The top of the wood strip should be approximately 3/4″ higher than the storm window frame (STORM WINDOW FRAME) or wood strip (OUTDOORS) to help condensation to drain properly to the outside.
  3. Install a second wood strip (approximately 6″ long by 11/2″ wide and same thickness as first strip) in the center of the outer sill flush against the back off the inner sill. This will raise the L bracket as shown Fig. 5-2.
  4. If the distance between STORM WINDOW FRAME and WOOD STRIP MOUNTED ON TOP OF INNER SILL is more than 1″, two of wood strips are not necessary.

Installation

A. BEFORE INSTALLATION

  1. Insert the guide panels into the guides of the air conditioner. Fasten the curtains to the unit with screws (TYPE A), as shown Fig. 6.
  2. Cut the adhesive-backed seal strip (TYPE D) to the window width.
    Remove the backing from the seal strip and attach the seal strip to the underside of the bottom window. (Fig. 7)

B. NOW START INSTALLATION

  1. LOCATING UNIT IN WINDOW

Open the window and mark center line on the center of the inner sill, as shown in Fig. 8.

  1. ATTACH L BRACKET

a. Install the L brackets behind the inner window sill, with the short side of bracket as shown. Use the

  1. crews (TYPE A) provided.

b. The bracket helps to hold unit securely in place. Be sure to place the bracket edge flush against the back of inner sill. See Fig. 9.

CAUTION

During the following step, hold unit firmly until the window sash is lowered to top channel behind side panel frames. Personal injury or property damage may result if unit falls from the window

INSTALL THE AIR CONDITIONER IN THE WINDOW

  • a. Carefully lift the air conditioner and slide it into the open window. Make sure the bottom guide of the air conditioner drops into the notches of the L bracket. See Fig. 9.

IMPORTANT :

When the air conditioner drops into the L bracket, the air conditioner will be centered in the window opening as shown in Fig. 10.

  • b. While steadying the air conditioner, carefully bring the window sash down behind the upper guide of the air conditioner, as shown in Fig. 11

SECURE THE GUIDE PANELS

Extend the guide panels (TYPE F) to fill the window opening using 4 screws (TYPE B) to secure them, as shown in Fig. 12.
INSTALL THE SASH SEAL AND SASH LOCK

  • a. Cut the sash seal (TYPE E) to the window width. Stuff the sash seal between the glass and the window to prevent air and insects from getting into the room, as shown in Fig. 12.
  • b. Fasten the L bracket using a screw (TYPE A), as shown in Fig. 12.
  • a. Remove the screws that secure the cabinet and base pan in the right side.
  • b. Fasten the suport bracket (TYPE G) using a removed screw. Attach the support bracket (TYPE G) in the inner window sill with a screw (TYPE B), as shown Fig. 13.

Window installation of room air conditioner is now completed. See ELECTRICAL DATA for attaching a power cord to an electrical outlet.

C. HOW TO SECURE THE DRAIN PIPE

In humid weather, excess water may cause the BASE PAN to overflow. To drain the water, remove the DRAIN CAP and secure the DRAIN PIPE to the rear hole of the BASE PAN. (Fig. 14) Press the drain pipe into the hole by pushing down and away from the fins to avoid injury.

REMOVAL FROM WINDOW

Turn the air conditioner off, disconnect the power cord, remove the L bracket, the screws, and the Support Bracket installed through the top and bottom of the guide panels, and save for reinstallation later. Close the guide panels. Keeping a firm grip on the air conditioner, raise the sash, and carefully tilt the air conditioner backward, draining any condensate. Lift the air conditioner from the window and remove the sash seal from between the windows.

Electrical Data

USE OF EXTENSION CORDS

Because of potential safety hazards, we strongly discourage the use of an extension cord. However, if you wish to use an extension cord, use a CSA- certified/UL-listed 3-wire (grounding) extension cord, rated 15A, 125V.

Before you call for service

Troubleshooting Tips save time and money! Review the chart below first and you may not need to call for service.

Normal Operating

  • You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
  • You may hear the thermostat click when the compressor cycles on and off.
  • Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.
  • The fan may run even when the compressor does not.

Abnormal Operation

Problem Possible Causes What To Do

Air conditioner does not start

| ■ The air conditioner is unplugged.| •  Make sure the air conditioner plug is pushed completely into the outlet.
The fuse is blown/circuit breaker is tripped.| •  Check the house fuse/circuit breaker box and replace the fuse or reset the breaker.
Power failure.| •  If power failure occurs, turn the mode control to Off. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload.

Air conditioner does not cool as it should

| ■ Airflow is restricted.| •  Make sure there are no curtains, blinds, or furniture blocking the front of the air conditioner.
The THERMOSTAT may not be set high enough.| •  Turn the knob to a higher number. The highest setting provides maximum cooling.
The air filter is dirty.| •  Clean the filter at least every 2 weeks. See the care and Maintenance section.
The room may have been hot.| •  When the air conditioner is first turned on, you need to allow time for the room to cool down.
Cold air is escaping.| •  Check for open furnace floor registers and cold air returns.
Cooling coils have iced up.| •  See Air Conditioner Freezing Up below.
Air conditioner freezing up| ■ Ice blocks the air flow and stops the air conditioner from cooling the room.| •  Set the mode control at High Fan or High Cool with thermostat at 1 or 2.