ESSICKAIR N31D Evaporative Cooler Owner’s Manual
- July 10, 2024
- ESSICKAIR
Table of Contents
N31D Evaporative Cooler
“`html
Essick N55S Evaporative Cooler
Specifications:
-
Models: 3000 DD, 3000 SD, 4001 DD, 4001 SD, 5000 DD, 5000 SD,
N31D, N30S, N43/48D, N40/45S, N56/66D, N55/65S -
Power: 120V or 240V A.C., single phase, 60 Hz
-
Safety Features: Grounded motor and pump, automatic thermal
overload switch
Product Usage Instructions:
Safety Rules:
-
Read all instructions carefully.
-
Electrical hook up should be done by a qualified
electrician. -
Always turn OFF POWER and UNPLUG motor and pump before
maintenance. -
Operates on either 120V or 240V A.C., single phase, 60 Hz
current. -
Pump receptacle is for grounded evaporative cooler pump
only.
Evaporative Cooling:
Evaporative cooling works by moving air over wet surfaces where
water evaporates and heat is absorbed. This unit draws air across
wet filter pads to cool the air through evaporation.
Operation:
-
To enhance cooling performance, pre-wet the pads by running the
pump before starting the blower if the pads are dry. -
Coolers can be used without water for ventilation. When outside
air is cool or humidity is high, the water pump can be turned
off. -
Install with a thermostat and attic exhaust dampers for
automatic operation.
Open Windows To Exhaust Air:
To ensure effective cooling, open windows to exhaust old air.
Proper ventilation is crucial for optimal performance of the
evaporative cooler.
FAQ:
Q: Can I use this cooler without water?
A: Yes, this cooler can be used without water for ventilation
purposes when outside air is cool or humidity is high.
Q: How often should I pre-wet the pads?
A: Pre-wet the pads by running the pump for a few minutes before
starting the blower if the pads are dry for best cooling
performance.
“`
This Owner’s Manual is provided and hosted by Appliance Factory Parts.
ESSICK N55S Owner’s Manual
Shop genuine replacement parts for ESSICK N55S
Find Your ESSICK Evaporative Cooler Parts – Select From 70 Models ——– Manual
continues below ——–
CHAMPION·ESSICK
Evaporative Cooler Manual
Models
3000 DD 3000 SD 4001 DD 4001 SD 5000 DD 5000 SD
N31D N30S N43/48D N40/45S N56/66D N55/65S
Read carefully all of this manual before installing the unit.
Circle the model of your cooler and record the serial number below.
Encierre con un circulo el modelo de su enfriador y escribe el número de serie
abajo.
Serial #
Número De Serie
Lea con cuidad todo este manual antes de instalar la unidad.
Read And Save These Instructions
Vea el Español en el interior
Safety Rules
1. Read instructions carefully. 2. Electrical hook up should be done by a
qualified electrician, so
that all electrical wiring will conform to your local standards. 3. Always
turn OFF POWER and UNPLUG motor and pump inside
the cooler before installing or performing any maintenance. 4. Your cooler
will run on either 120V or 240V A.C., single phase,
60 Hz (cycle) current. 5. Motor and pump have a grounded, molded plug and an
automatic
thermal overload switch which will shut motor off when it overheats. The motor
will restart automatically when it cools down. 6. Pump receptacle is for
grounded evaporative cooler pump only. Do not plug anything else into
receptacle. WARNING: To reduce the risk of fire or electric shock, do not use
this fan with any “solid-state fan speed control device.”
Evaporative Cooling
Evaporative cooling is nature’s way of cooling. When air is moved over a wet
surface, water is evaporated and heat is absorbed. When stepping out of a
swimming pool with the wind blowing, evaporative cooling makes you feel cool,
even though the air may be warm. The human body itself is cooled primarily by
the evaporation of perspiration.
This unit works on the same principle. Air is drawn across wet filter pads
where the air is cooled by evaporation and then circulated throughout the
building. It is this combination of cooled air and the movement of air over
the skin which makes it feel cool.
Unlike refrigeration systems which recirculate the air, an evaporative cooler
continually brings in fresh air while exhausting old air. You are completely
replacing the air every 2 to 4 minutes by opening windows or doors or a
combination of both. The air is always fresh, not stale, laden with smoke and
odors as happens with refrigerated air conditioning.
Operation
For the best cooling performance, if the pads are dry, pre-wet the pads by
running the pump for a few minutes before starting the blower.
These coolers may be used without water for ventilation purposes. When outside
air is cool (for example, at night) or when humidity is high, the water pump
can be turned off.
A cooler can also be installed with a thermostat and attic exhaust dampers to
provide completely automatic operation.
Open Windows To Exhaust Air
An often misunderstood concept of evaporative cooling is the amount of air
that should be exhausted. How much should you open your windows? The fact is
that most people do not open their windows enough. The following two methods
will help you determine the amount to open your windows.
CFM Method
You should allow an opening of at least 2 square feet (288 square inches) for
each 1000 CFM rating of your unit. Example: At 3654 CFM, model 4001 DD with a
1/2 hp motor requires 7.3 square feet (1052 square inches) of opening
(3654/1000 * 2 = 7.3). Multiply the number of windows by window width in
inches and divide this into the number of square inches required for your size
unit. This will give you the height to open windows. In this example, four 36
inch wide windows should be opened 7.3 inches each.
110503-1
www.championcooler.com
8-08
Champion Air Balancing Method
1. Take a piece of tissue paper and cut it lengthwise into 3 equal strips. 2.
Turn your cooler on high cool. 3. Open one window at least six inches wide in
each room that you want
to cool. 4. Take the piece of tissue paper and put it up against the screen of
the open
window furthest from the cooler discharge opening. Let go of it. It will do
one of three things.
IF
It falls down.
THEN CLOSE all of the windows one inch and try step 4 again.
IF
It plasters itself to the screen.
THEN OPEN all of the windows one inch and try step 4 again.
IF
It stays on the screen lightly.
THEN PERFECT. You are done. Enjoy your cooler.
NOTES: · When switching to low cool, you must rebalance your home. Repeat step
4. · Once you balance your home you can cool some areas more than others by
opening those windows more and closing the others by the same amount. Repeat
step 4 to make sure your home is still air balanced.
Installation
NOTE: The pump comes installed. The belt, motor pulley, and motor cord and
float are included in the cabinet, the motor is shipped separately.
CAUTION: Make sure that the mounting surface is strong enough to support the
operating weight of the cooler when in use.
(For operating weight, see Specification Table.) CAUTION: Never plug in cooler
until installation is complete
and unit has been tested for rigidity.
· Install Duct Adapters. If desired, a 4 piece duct adapter is available as an
optional accessory. Call 1-800-643-8341
to obtain these from the factory. Align the holes in the duct adapter to the
holes in the blower opening and attach using the provided screws (see Fig. 1).
Repeat for all four sides. Note: All 4 pieces are identical except for models
5000SD & N55/65S which have an offset piece which attaches to the bottom of
the outlet. To install this offset piece, remove the screws holding the cut-
off plate and slide the offset duct adapter between the blower opening and the
cutoff plate. You may need to loosen other screws to do this. Line up the
holes and secure with the screws previously removed.
Motor Installation
· Install motor cord. For typical 120V operation, connect motor cord to motor
using the following color code: Black – Hi, Red – Low, White – Com., Green –
Ground. (See Wiring Diagrams)
· Mount motor. Install blower motor in the motor mount yokes, adjusting the
yoke if necessary. Fasten with the provided mounting clips (see Fig. 2).
Duct Adapter
Cut-Off Plate
Fig. 1
Motor Clips
Adjustable
Fig. 2 Yoke
Motor Pulley
· Install pulley. Install the adjustable motor pulley so that it aligns with the blower drive pulley (see Fig. 3) and tighten set screw.
Blower Housing
Blower Pulley
Fig. 3
Electrical Installation
WARNING: Disconnect all electrical service that will be used
for this unit before you begin the installation.
2
· Remove junction box. The electrical junction box is located in the upper inside corner of the cooler cabinet. Remove the two screws and remove the junction box (Fig. 4). Slide receptacles into slots in junction box.
Screws
Junction Box
Clip
Fig. 4
· Hook up electrical. Electrical hook up should be done by a qualified
electrician, so that all electrical wiring will conform to your local
standards. This unit is suppled with a 120V pump. For 240V pump operation, a
240V pump must be purchased. The fan and pump receptacles will support both
120V and 240V installations. See the wiring diagrams for 120V and 240V
installations. Note: Clip pump cord onto cord clip located on the bottom of
the junction box to keep cord our of the water. IMPORTANT: When a single speed
motor is used, do not use the red lead on the receptacle and motor plug
wiring. Tape off end of both of the red leads.
CAUTION: Pump receptacle is for grounded evaporative cooler pump only. Do not
plug anything else into receptacle.
WARNING: Make sure the cooler cabinet is properly grounded to a suitable
ground connection for maximum safety.
Wiring Diagrams
Pump Motor
Hi Lo Com. Ground
Black Red White Green
Blower Motor
120 Volts
Blue/Black White Brown Orange Green
Black Red White Orange Green
Pump
Hi Lo Com.
Ground
To Switch
= Wire Nut
Pump Motor
Hi Lo Com. Ground
Black Red Orange Green
Blower Motor
240 Volts
Blue/Black White Brown Orange Green
Black Red White Orange Green
Pump
Hi Lo Com. Ground
To Switch
= Wire Nut
Fig. 5
Water Connection
· Install overflow assembly. Place drain nipple through the hole in the pan,
with the rubber washer between the pan and the head of the drain nipple (Fig.
6). Screw on nut and draw up tight against bottom of pan. Insert the overflow
pipe in the nipple to retain water. The overflow pipe may be removed to drain
the pan when necessary. A garden hose may be screwed on the drain nipple to
drain water away from your unit.
· Connect water supply line. Find the closest supply of water. Use a saddle
valve (Fig. 7) to connect 1/4″ tubing to the cold water supply or use a
Sillcock and water valve connected to an outside faucet (Fig. 8). Place the
nut and ferrule on the tubing and tighten the nut until water tight.
IMPORTANT: Do not connect the water supply to any soft water applications.
Soft water will cause corrosion and decrease the life of the cooler.
Overflow Pipe
Nipple Rubber Washer Bottom Pan Nut
Fig. 6
1/4″ Tubing Saddle Valve
Fig. 7
Cold Water Pipe
110503-1
Water Supply Valve Ferrule Nut
· Install float and attach water line to float. The float may be installed in
either the corner post or bracket (see Fig. 9). If you have model 3000DD/N31D
then the float should be mounted to the bracket. Refer to figure 10 for
installation instructions. Insert the float (1) thru the hole in the corner
post or bracket. Install the washer (2) and nut (3). Tighten to keep the float
from turning. Place the nut (5) and ferrule (4) on the water supply line.
Connect to float fitting and tighten until water tight.
· Fill pan. Allow water to fill to within 1″ of top of pan and adjust float to
maintain this water level. This can be accomplished by bending the float rod.
Faucet
Sillcock
Fig. 8
Corner Post
Bracket
Float
· Level water troughs. Operate pump until pads are saturated. Check each trough to see if water is evenly dispersed in the trough. If they are not, loosen adjustment bolts and level trough. Retighten bolts. Check to see that all pads are saturated with water and that there are no dry spots or openings in the pads.
Fig. 9
1
6 5 4 3 2
Fig. 10
Bleed-Off
Installation of the bleed-off kit is recommended to increase the life of the
cooler. A bleed-off system is designed to prevent scale build up by
continually removing a small percent of the water in the pan.
· Install Bleeder Tee and Tubing.
Refer to figure 11. Cut the pump Pump Hose
hose and insert the barbed ends of the bleeder tee into each cut end. Insert one end of the bleeder tubing onto the bleeder tee and run the other end out of the cooler
Bleeder Tee Bleeder Tubing
Restrictor Overflow
through the overflow pipe. Note: A
restrictor clamp is provided which, if desired, may be installed onto the
Fig. 11
bleeder tubing to restrict the amount of water being bleed off. The amount
of water to bleed off depends on the quality of the water in your area. Start
with 1-2 gal/hr and increase if needed.
Amperage Draw And Belt Tension
This unit is equipped with an adjustable motor drive pulley for adjusting the
blower wheel speed to the proper loading on different duct systems. It is
important that the motor drive pulley is adjusted to correct size to assure
maximum air delivery without damage to the motor. Be sure to follow these
instructions carefully.
· Adjust drive pulley. After the unit is completely installed, adjust the drive pulley to the least diameter and adjust belt tension. See the maintenance section for adjusting belt tension.
· Start cooler. Install all pad frames, start pump, and allow to operate until pads are wet.
· Check amperage. With pads wet and unit started, check amperage draw with an amperage meter.
· Adjust pulley if necessary. If amperage draw is less than motor rating, turn
off electrical power and remove pad frame. Unplug motor inside cooler, this
will protect you from someone turning on unit while you are working inside.
This should be done for your
110503-1
Decrease Amperage
Fig. 12
safety. Adjust pulley to a larger diameter and readjust belt tension, plug
motor in, install pad frame, and retest amperage draw. Repeat this process
until correct amperage draw is attained. Increasing motor pulley diameter
increases amperage draw. Decreasing motor pulley diameter decreases amperage
draw (see Fig. 12).
CAUTION: Do not operate cooler with larger amperage draw
than specified on motor plate.
NOTE: No attempt should be made to completely install this unit without the
aid of an electrician or someone familiar with testing amperage draw. Failure
to comply with these instructions may void your warranty.
Maintenance
WARNING: Before doing any maintenance be sure power is off. At the time you
remove a pad frame be sure to unplug motor and pump. This is for your safety.
Spring Start-Up
· Clean pump. Cleaning the pump is necessary once a year at start-up. For
your safety, turn unit off and unplug motor and pump. Remove the pump
from the mount slot. Remove the base of the pump (Fig. 13). Clean the
pump and turn the impeller to ensure free operation. Remove the pump
spout and check for any blockage.
After cleaning, reinstall the base onto the pump. Press firmly to
Remove Base
make sure it is secure. Reattach
the pump to the mount in the cooler
using the plastic retainer to ensure
that the pump will not overturn. Do
not forget to replace the spout and
Impeller
water delivery tube onto the pump outlet.
Fig. 13
· Oil bearings. The blower bearings and cooler motor in this unit should be
oiled with a few drops of non-detergent 20/30 weight oil once each year. The
motor does not need oil if it has no oil lines for oiling. Motors that have no
lines are lifetime oiled at the factory and require no further oiling for the
life of the unit.
CAUTION: Do not over oil. Over oiling can cause motor burn
out, due to excessive oil getting into motor winding.
· Change Pads. The pads should be replaced once or twice a season, depending upon the length of the season. At the beginning and at mid season a clean pad is more absorbent and efficient and will deliver substantially more cool air.
· Check belt tension. A 3 lb. force should deflect the belt 3/4 inches (see Fig. 14). Readjust belt if needed.
3 Lb. 3/4 Inches
· Check bleed-off valve to be sure it is not clogged.
Fig. 14
WINTER SHUT DOWN
· Drain water. Always drain all of the water out of the cooler and water
supply line when not in use for prolonged periods, and particularly at the end
of the season. Keep the water line disconnected from both the unit and water
supply so that it does not freeze.
· Unplug motor and pump. When cooler is not used for extended periods, unplug
the motor and pump from inside cooler.
· Cover unit. To protect the life of the finish, a cover for the unit is
suggested in extended periods of non use.
By following the operating, installation, and maintenance suggestions as
outlined, you can get many years of efficient and satisfactory service from
your cooler. In the event additional information is desired, your dealer will
be more than glad to assist you in every possible way.
3
Troubleshooting
Problem Possible Cause
Remedy
Failure to 1. No electrical power to
start or no air unit
delivery
· Fuse blown
· Circuit breaker tripped
· Electric cord unplugged
or damaged
2. Belt too loose or tight
3. Motor overheated
· Belt too tight · Blower bearings dry · Motor pulley diameter
too large 4. Motor locked
1. Check power
· Replace fuse · Reset breaker · Plug in cords or
replace if damaged 2. Adjust belt tension 3. Determine cause of
overheating · Adjust belt tension · Oil blower bearings · Adjust pulley to
cor-
rect diameter 4. Replace motor
Inadequate air delivery with cooler running
1. Insufficient air exhaust 2. Belt too loose
3. Pads plugged 4. Motor underloaded
1. Open windows or doors to increase air flow
2. Adjust belt tension or replace if needed
3. Replace pads 4. Adjust pulley to full
load ampere rating of motor
Inadequate cooling
1. Inadequate exhaust in house
2. Pads not wet
· Pads plugged · Open spots in pads · Trough holes clogged
· Pump not working properly
1. Open windows or doors to increase air flow
2. Check water distribution system
· Replace pads · Repack pads · Clean trough and
unplug holes · Replace or clean pump
(Unplug unit)
Problem Possible Cause
Remedy
Motor cycles on and off
1. Low voltage 2. Excessive belt tension 3. Blower shaft tight or
locked 4. Bearings dry 5. Motor pulley diameter
too large causing motor overload
1. Check voltage 2. Adjust belt tension 3. Oil or replace bearings
(Unplug unit) 4. Oil bearings 5. Adjust pulley so full
load ampere rating of motor is not exceeded
Noisy
1. Bearings dry 2. Wheel rubbing blower
housing 3. Loose parts
1. Oil bearings 2. Inspect and realign
(Unplug unit) 3. Tighten loose parts
Musty or unpleasant odor
1. Stale or stagnate water in cooler
2. Pads mildewed or clogged
3. Pads not wetting properly
· Trough holes clogged · Pump not working
properly
1. Drain pan and clean pads
2. Replace pads
3. Check water distribution system
· Clean · Replace or clean pump
(Unplug unit)
Water draining onto roof
1. Float arm not adjusted properly
2. Overflow assembly leaking
1. Adjust float
2. Tighten nut and overflow pipe.
Excessive humidity in house
1. Inadequate exhaust
1. Open doors or windows
Register your product online at www.championcooler.com/eac/onlineregistration- eac.htm
Limited Warranty
This warranty is extended to the original purchaser of an evaporative cooler installed and used under normal conditions. It does not cover damages incurred through accident, neglect, or abuse by the owner. We do not authorize any person or representative to assume for us any other or different liability in connection with this product.
Terms And Conditions Of The Warranty For Eight Years from date of Purchase, we will replace the original base assembly if water leakage should occur due to rust out.
For One Year from date of Purchase, we will replace any original component provided by Champion Cooler which fails due to any defect in material or factory workmanship only.
Exclusions From The Warranty We are not responsible for replacement of cooler pads. These are disposable components and should be replaced periodically. We are not responsible for any incidental or consequential damage resulting from any malfunction.
We are not responsible for any damage received from the use of water softeners, chemicals, descale material, plastic wrap, or if a motor of a higher horsepower than what is shown on the serial plate is used in the unit.
We are not responsible for the cost of service calls to diagnose cause of trouble, or labor charge to repair and/or replace parts.
How To Obtain Service Under This Warranty Contact the Dealer where you purchased the evaporative cooler. If for any reason you are not satisfied with the response from the dealer, contact the Customer Service Department: 5800 Murray Street, Little Rock, Arkansas 72209. 1-800-643-8341. E-mail: info@championcooler.com.
This limited warranty applies to original purchaser only.
4
110503-1
Replacement Parts List / Lista De Piezas De Recambio
When ordering parts, please be sure to furnish the following information on all orders. Failure to do so may delay your order. / Al pedir piezas, incluya toda la información siquiente con su pedido. El no proporcionar toda esta información resultará en una demora.
Cooler model number / El modelo de su enfriador
Cooler serial number / Número de serie de la unidad
Motor HP / C.V. del motor
Description and part number / Descripción y número de pieza
Date of purchase / Fecha de compra
No.
3000 DD
N° Description / Descripción
N31D
1. Top Pan / Tapa —————————————————————————————-222903-003
2. Bottom Pan / Base De La Caja ———————————————————————322907-002
3. Louvered Side / Reja Lateral ———————————————————————–224006-003
4. Water Trough / Canal De Agua———————————————————————226003-001
5. Aspen Pads / Filtros De Paja ———————————————————————–110091
6. Pad Retainers / Soporte Para El Filtro ————————————————————3PW-4
7. Corner Post, With Float Hole / Poste De Esquina, Con Agujero Para Flotador ————224003-008
8. Corner Post, No Float Hole / Poste De Esquina, Sin Agujero Para Flotador—————-224003-026
8a. Corner Post, For Pump Mount / Poste De Esquina, Para Montar La Bomba —————-224003-038
9. Cut-Off Plate / Placa Limitadora ——————————————————————224002-001
10. Blower Housing / Caja De La Rueda————————————————————–324106-202
11. Blower Wheel / Rueda——————————————————————————-12BW
12. Shaft, Blower Wheel / Eje De La Rueda ———————————————————-110182
13. Bearings, Blower Wheel Shaft / Cojinetes Del Eje De La Rueda —————————–110351
14. Pulley, Blower Wheel / Polea De La Rueda——————————————————110274
15. Drive Belt / Correa———————————————————————————–110211
16. Motor / Motor—————————————————————————————–*
17. Pulley, Motor / Polea Del Motor ——————————————————————-110277
18. Motor Mount / Montura Del Motor—————————————————————-314003-002
19. Motor Mount Clips / Seguros Para Montar Motor ———————————————-314005-001
20. Electrical Cord, Motor (115V) / Cable Eléctrico Del Motor (115V) ————————–110364
20. Electrical Cord, Motor (230V) / Cable Eléctrico Del Motor (230V) ————————110372-2
21. Float Valve / Flotador ——————————————————————————-FL-C
22. Pump Mount / Montura De La Bomba ————————————————————218001-030
23. Pump Screen / Malla Para La Bomba————————————————————-281001-001
24. Pump Assembly / Bomba—————————————————————————-110436
25. Pump Retainer / Sujetador De La Bomba———————————————————110714
26. Air Baffle / Bafle De Aire —————————————————————————224112-001
27. Float Bracket / Soporte Del Flotador————————————————————–216001-003
28. Tube, Water Delivery / Tubo De Agua————————————————————-310716
30. Over Flow Assembly / Montaje De Desagüe—————————————————–3OA-1
31. Water Distributor Assembly / Sistema Del Distribuidor De Agua—————————–3D-4
32. Holder, Water Distributor / Soporte Para El Distribuidor De Agua ————————–110574
34. Electrical Junction Box / Caja De Empalme —————————————————–320106-002
35. Receptacle, Motor / Tomacorriente Del Motor—————————————————110393
36. Receptacle, Pump / Tomacorriente De La Bomba ———————————————–110361
37. Bearing Mount, Right / Montura Del Cojinete, Derecha —————————————-
38. Bearing Mount, Left / Montura Del Cojinete, Izquierda—————————————–
39. Motor Mount Support, Right / Soporte Para El Montura Del Motor, Derecho—————
40. Motor Mount Support, Left / Soporte Para El Montura Del Motor, Izquierdo —————
41. Channel Retainer Support / Soporte Para El Retendedor De Canal ————————–
42. Bleed-Off Kit / Equipo De Purga —————————————————————–310586
4001 DD N43/48D 220901-002 320905-007 224007-005 226003-002 110098 3PW-5 224003-034 224003-035 224003-039 224004-002 324107-007 16BW 110183 110351 110275 110215 * 110278 314003-004 314005-001 110364 110372-2 FL-C 218001-031 281001-001 110436 110714 216001-003 310716 3OA-1 3D-5 110574 320106-002 110393 110361 310586
5000 DD N56/66D 220903-002 320906-005 224008-003 226003-003 110092 3PW-6 224003-025 224003-010 224003-040 224004-003 324111-001 20BW 110183 110351 110276 110214 * 110278 314003-008 314005-001 110364 110372-2 FL-C 218001-031 281001-001 110436 110714 224108-003 216001-003 310716 3OA-1 3D-6 110574 320106-002 110393 110361 214114-001 214114-001 214114-002 214114-002 218114-001 310586
- See motor specification table. / Vea la tabla de especificaciones del motor. 230V motor cord is optional and not supplied with cooler. / Cable eléctrico del motor de 230V es opcional y no se envía con el enfriador. NOTE: Standard hardware items may be purchased from your local hardware store. NOTA: Artículos de uso corriente pueden comprarse en la ferretería de su localidad.
110503-1
5
Parts Drawing / Dibujo De Piezas
3000DD, 4001DD, 5000DD N31D, 43/48D, 56/66D
General Specifications / Especificaciones Generales
Model No. HP
Modelo
C.V.
3000DD & N31D
1/3
4001DD & 1/3
N43/48D
1/2
5000DD & 1/2
N56/66D
3/4
3000SD & N30S
1/3
4001SD & 1/3
N40/45S
1/2
5000SD & 1/2
N55/65S
3/4
Weight (lbs.)
Peso (libras)
*Dry
*Operating
Seco
Lleno
125
175
165
232
166
233
222
305
226
309
116
193
154
268
155
269
204
353
208
357
- Includes motor weight / Incluye el peso del motor.
6
Cabinet Dimensions (in.)
Dimensiones De La Caja (pulgadas)
Height
Width
Depth
Altura
Anchura Profundidad
33 7/16
28 1/8
28 1/8
Duct Opening (in.)
Abertura De Ducto (pulgadas)
Width
Height
Anchura
Altura
13 5/8
13 5/8
34 1/2
34 1/8
34 1/8
17 3/4
17 3/4
42 7/16
39
39
19 3/4
19 3/4
33 7/16
28 1/8
28 1/8
13 5/8
13 5/8
34 1/2
34 1/8
34 1/8
17 3/4
17 3/4
42 7/16
39
39
19 3/4
19 3/4
110503-1
Parts Drawing / Dibujo De Piezas
3000SD, 4001SD, 5000SD N30S, N40/45S, N55/65S
Motor Specifications / Especificaciones Del Motor
Model No. Modelo
3000DD, N31D, 3000SD & N30S
HP Motor Part # Speed Volts *Amperage Motor Pulley Part # C.V. Motor – N° Velocidad Voltios Amperaje Polea Del Motor – N°
1/3
110444 110445
1 2
115
7.2
110277
Drive Belt Part # Correa – N°
110211 (4L-450)
1/3 4001DD, N43/48D,
110444 110445
1 2
115
7.2
4001SD & N40/45S 1/2
110446 110447
1 2
115
9.8
110278
110215 (4L-560)
1/2 5000DD, N56/66D, 5000SD & N55/65S
3/4
110446 110447
110448 110449
1 2
115
9.8
1 2
115
13.8
110278
(DD, D) 110214 (4L-690) (SD, S) 110213 (4L-670)
- 1/2″ Bore x Adjustable O.D. / Taladro de 1/2 pulgadas x Diámetro Externo Ajustable. ** Amperage shown is from National Electric Code. Use motor nameplate for more accurate amp reading. / El amperaje listado es del código
eléctrico nacional. Utilice el amperaje indicado en la place del motor para un amperaje más exacto.
110503-1
7
Replacement Parts List / Lista De Piezas De Recambio
When ordering parts, please be sure to furnish the following information on all orders. Failure to do so may delay your order. / Al pedir piezas, incluya toda la información siquiente con su pedido. El no proporcionar toda esta información resultará en una demora.
Cooler model number / El modelo de su enfriador
Cooler serial number / Número de serie de la unidad
Motor HP / C.V. del motor
Description and part number / Descripción y número de pieza
Date of purchase / Fecha de compra
No.
3000 SD
N° Description / Descripción
N30S
1. Top Pan / Tapa ……………………………………………………………………………………………………222903-002
2. Bottom Pan / Base De La Caja……………………………………………………………………………..222904-003
3. Louvered Side / Reja Lateral………………………………………………………………………………..224006-003
4. Water Trough / Canal De Agua …………………………………………………………………………….226003-001
5. Aspen Pads / Filtros De Paja ……………………………………………………………………………….110091
5a. Glass Fiber Pads / Filtros De Vidrio ………………………………………………………………………-
6. Pad Retainers / Soporte Para La Esponja ………………………………………………………………3PW-4
7. Corner Post, With Float Hole / Poste De Esquina, Con Agujero Para Flotador ………….224003-004
8. Corner Post, For Pump Mount / Poste De Esquina, Para Montar La Bomba ………………224003-041
9. Front Panel / Panel De Frente ………………………………………………………………………………224106-001
10. Cut-Off Plate / Placa Limitadora ………………………………………………………………………….224002-001
11. Blower Housing / Caja De La Rueda …………………………………………………………………….324106-102
12. Blower Wheel / Rueda…………………………………………………………………………………………12BW
13. Shaft, Blower Wheel / Eje De La Rueda ………………………………………………………………..110182
14. Bearings, Blower Wheel Shaft / Cojinetes Del Eje De La Rueda ………………………………110351
15. Pulley, Blower Wheel / Polea De La Rueda……………………………………………………………110274
16. Drive Belt / Correa ……………………………………………………………………………………………..110211
17. Motor / Motor …………………………………………………………………………………………………….*
18. Pulley, Motor / Polea Del Motor …………………………………………………………………………..110277
19. Motor Mount / Montura Del Motor……………………………………………………………………….314003-006
20. Motor Mount Clips / Seguros Para Montar Motor ………………………………………………….314005-001
21. Electrical Cord, Motor (115V) / Cable Eléctrico Del Motor (115V)…………………………..110364
21. §Electrical Cord, Motor (230V / Cable Eléctrico Del Motor (230V) …………………………§110372-2
22. Float Valve / Flotador………………………………………………………………………………………….FL-C
23. Pump Mount / Montura De La Bomba …………………………………………………………………..218001-031
24. Pump Screen / Malla Para La Bomba……………………………………………………………………281001-001
25. Pump Assembly / Bomba……………………………………………………………………………………..110436
26. Pump Retainer / Sujetador De La Bomba ………………………………………………………………110714
28. Tube, Water Delivery / Tubo De Agua……………………………………………………………………310716
29. Duct Adapters / Adaptores Del Conducto……………………………………………………………..324016-001
30. Over Flow Assembly / Montaje De Desagüe ………………………………………………………….3OA-1
31. Water Distributor Assembly / Sistema Del Distribuidor De Agua ……………………………..3D-2
32. Holder, Water Distributor / Soporte Para El Distribuidor De Agua …………………………..110574
34. Electrical Junction Box / Caja De Empalme …………………………………………………………..320106-002
35. Receptacle, Motor / Tomacorriente Del Motor ……………………………………………………….110393
36. Receptacle, Pump / Tomacorriente De La Bomba……………………………………………………110361
37. Float Bracket / Soporte Del Flotador …………………………………………………………………….216001-003
38. Bleed-Off Kit / Equipo De Purga………………………………………………………………………….310586
39. Air Baffle / Bafle De Aire …………………………………………………………………………………….-
4001 SD N40/45S 220901-001 220902-002 224007-005 226003-002 110098 110129-003 3PW-5 224003-034 224003-039 224105-005 224004-001 324107-206 16BW 110183 110351 110275 110215 * 110278 314003-004 314005-001 110364 §110372-2 FL-C 218001-031 281001-001 110436 110714 310716 324016-002 3OA-1 3D-10 110574 320106-002 110393 110361 216001-003 310586 222119-002
5000 SD N55/65S 220903-001 220905-006 224008-003 226003-003 110092 3PW-6 224003-006 224003-043 222108-004 224004-001 324108-004 20BW 110183 110351 110276 110213 * 110278 314003-004 314005-001 110364 §110372-2 FL-C 218001-031 281001-001 110436 110714 310716 324016-003 3OA-1 3D-9 110574 320106-002 110393 110361 216001-003 310586 224108-003
- See motor specification table. / Vea la tabla de especificaciones del motor. Optional Accessory. Not included with unit. / Accesorio opcional. No incluido con la unidad. § 230V motor cord is optional and not supplied with cooler. / Cable eléctrico del motor de 230V es opcional y no se envía con el enfridor. NOTE: Standard hardware items may be purchased from your local hardware store. NOTA: Artículos de uso corriente pueden comprarse en la ferretería de su localidad.
8
110503-1
Lea y Conserve Estas Instrucciones
Reglas De Seguridad
1. Lea las instrucciones con cuidado. 2. Las conexiones eléctricas deben ser
hechas por un electricista com-
petente, para que todo el cableado eléctrico cumpla con los requisitos
establecidos en su localidad. 3. Siempre CORTE LA CORRIENTE y DESCONECTE el
motor y la bomba en el interior del aparato antes de instalar o realizar
cualquier labor de mantenimiento. 4. Su enfriador funciona con corriente
alterna de 120V o 240V, de una fase y 60 Hz. (ciclos). 5. El motor y la bomba
están provistos de clavijas moldeadas, con toma de tierra, y se apagarán
automáticamente en caso de sobrecalentamiento. Los motores volverán a
funcionar cuando se enfrían.
ADVERTENCIA: Para reducir el riesgo de incendio o toques eléctricos, no use
este ventilador con ningún “dispositivo de estado sólido para controlar la
velocidad del ventilador.”
Enfriamiento Por Evaporación
El enfriamiento por medio de evaporación es la manera de la naturaleza de
refrescarse. Cuando el aire se mueve sobre una superficie mojada, se evapora
el agua y se absorbe el calor. Al salir de una piscina con el viento que sopla
usted se siente fresco, aunque el aire puede ser caliente. El cuerpo humano sí
mismo es refrescado principalmente por la evaporación del sudor.
Este enfriador funciona usando el mismo principio. El aire se traza a través
de los filtros mojados donde el aire se enfría por medio de evaporación y
después circula a través del edificio. Se hace frío de la sensación cuando
tiene esta combinación del aire enfriado y del movimiento del aire sobre la
piel.
A diferencia de los acondicionadores de aire que recirculan el aire, un
enfriador evaporativo trae continuamente por dentro el aire fresco mientras
agota el aire viejo. Se reemplaza completamente el aire cada 2 a 4 minutos,
abriendo las ventanas o las puertas o una combinación de ambas. El aire es
siempre fresco, no es viciado, cargado de humo y olores como ocurre con los
sistemas de aire acondicionado a base de refrigeración.
Funcionamiento
Para que no salga aire caliente al principio, prenda sólo la bomba durante
unos cuantos minutos; luego prenda también el motor del ventilador.
Su unidad puede ser utilizada sin agua para proporcionar ventilación
solamente. Cuando hace fresco (por ejemplo, de noche) o cuando la humedad es
alta, la bomba de agua puede ser apagada.
La unidad puede ser instalada también con termostato y reguladores de escape
en el ático para obtener un funcionamiento totalmente automático.
¿Cuánto Debe Abrir Las Ventanas?
Un concepto a menudo entendido mal de enfriamiento por evaporación es la
cantidad de aire que debe ser agotada. Cuánto debe usted abrir sus ventanas?
El hecho es que la mayoría de la gente no abre sus ventanas bastante. Los dos
métodos siguientes le ayudarán.
El Método De PCM
Usted debe dejar una abertura de dos pies cuadrados por cada 1000 P.C.M. (pies
cúbicos por minuto), según la capacidad de su modelo.
110503-1
Ejemplo: El Modelo 4001 DD con un motor de 1/2 C.V. y con un rendimiento de 3654 P.C.M. requiere 7,3 pies cuadrados (1051 pulgadas cuadradas) de abertura (3654/1000 * 2 = 7,3). Ahora, multiplique el número de las ventanas por el ancho de las mismas; luego divida esta cantidad entre el número de pulgadas cuadradas requeridas para su unidad. El resultado le dice hasta qué altura hay que abrir las ventanas. En este ejemplo, cuatro ventanas que miden 36 pulgadas (0,9 m.) de ancha se deben abrir 7,3 pulgadas por cada una.
El Método De Equilibrar El Aire
1. Tome un pedazo de papel de seda y córtelo a lo largo en 3 tiras iguales.
2. Ponga en marcha a su enfriador a “High-Cool”. 3. Abra una ventana por lo
menos seis pulgadas de ancho en cada sitio
que usted desee refrescar. 4. Tome un pedazo de papel de seda y póngalo contra
la pantalla de la
ventana abierta más lejos de la apertura del enfriador. Suéltalo al papel de
seda. Hará una de tres cosas:
SI: ENTONCES:
Se caiga. CIERRE todas las ventanas una pulgada e intente el paso 4 otra vez.
SI: ENTONCES:
Se queda contra la pantalla con fuerza. ABRA todas las ventanas una pulgada e intente el paso 4 otra vez.
SI: ENTONCES:
Se queda ligeramente contra la pantalla. PERFECTO. Se ha acabado. Goce del aire refrescante.
NOTAS: · Al poner el enfriador a “low-cool”, usted debe reequilibrar el aire
de
su hogar. Repita el paso 4. · Al equilibrar el aire de su hogar usted puede
refrescar algunas áreas
más que otras abriendo esas ventanas más y cerrando las otras por la misma
cantidad. Repita el paso 4. Asegurarse de que el aire de su hogar sea
equilibrado.
Instalación
NOTA: Los enfriadores vienen con la bomba instalada. La banda, la polea del
motor, y el cable del motor y el flotador están incluidos en la unidad. El
motor se envía por separado.
PRECAUCIÓN: La superficie en que ha de colocarse el enfriador deberá aguantar
el peso completo de la unidad cuando ésta está en funcionamiento. (Para saber
este peso, vea la tabla de especificaciones.)
PRECAUCIÓN: No conecte el enfriador hasta que la instalación esté completa y
se haya comprobado la estabilidad del mismo.
· Instale los adaptadores del conducto. Un adaptador del conducto
de 4 pedazos es disponible como un accesorio opcional. Llame 1-
800-643-8341 para obtener éstos de la fábrica. Alinee los agujeros en los adaptadores con los agujeros en los lados del salida y sujételos
Adaptor De Conducto
con los tornillos proporcionados (véase fig.
1). Nota: Los 4 pedazos son idénticos a ex-
cepción del modelos 5000SD y N55/65S, lo
cuales tienen un pedazo formado que sujeta
al fondo del salida. Para instalar este pedazo
formado, quite los tornillos de la placa limita-
dora y deslice el pedazo formado entre la placa
limitadora y la salida. Puede necesitar aflojar
otros tornillos para realizar esto. Alinee los agujeros y sujete el adaptador con los tornillos quitados previamente.
Placa Limitadora
Fig. 1
9
Instalación Del Motor
· Instale el cable del motor. Para la instalación típica de 120V, conecte el
cable al motor usando las claves de colores siguientes: Negro – Alto, Rojo –
Bajo, Blanco – Común, Verde – Tierra. (Vea la esquema del cableado).
· Monte el motor. Instale el motor del ventilador en las horquillas de la montura. Ajuste la horquilla ajustable si es necesario y sujete el motor con los seguros (véase fig. 2).
· Instale la polea del motor. Instale la polea ajustable del motor para que queda alineada con la polea del ventilador (véase fig. 3) y apriete el tornillo.
Seguros
Polea Del Motor
Caja De La Rueda
Polea Del Ventilador
Horquilla
Fig. 2 Ajustable
Fig. 3
Instalación Eléctrica
ADVERTENCIA: Desconecte todos los servicios eléctricos
que serán usados en esta unidad antes de instalar el enfriador.
· Quite la caja de empalme. La caja de empalme se encuentra en el rincón superior del interior del enfriador. Quite los dos tornillos de la caja y quite la caja de empalme (fig. 4). Deslice las tomacorrientes a la ranura de la caja de empalme.
Tornillos
Caja De Empalme
Fig. 4
· Conecte el cableado eléctrico. Las conexiones eléctricas deben ser hechas
por un electricista competente, para que todo el cableado eléctrico cumpla con
los requisitos establecidos por su localidad. Esta unidad viene equipado con
una bomba de 120V. Para la alimentación de 240V, necesita comprar una bomba de
240V. Las tomas de corriente del ventilador y bomba soportan ambas
instalaciones de 120V y 240V. Vea las esquemas del cableado para las
instalaciones de 120V y 240V en la página 11. Nota: Sujete el cable de la
bomba en el clip situado en el fondo de la caja de empalme para no tocar el
agua. IMPORTANTE: Con un motor de una sola velocidad, no use la línea roja en
el cableado del enchufe y la clavija del motor. Envuelva el extremo de ambas
líneas rojas con cinta eléctrica.
PRECAUCIÓN: Enchufe una bomba del enfriador evaporativo solamente y nada más
al receptáculo de la bomba.
ADVERTENCIA: Asegúrese de que el enfriador tiene una conexión apropiada a toma
de tierra.
Conectar El Agua
· Instale el montaje de desagüe. Pase la boquilla por el agujero de la
bandeja, colocando la arandela de goma entre la bandeja y la cabeza de
la boquilla (véase fig. 5). Coloque la tuerca en la boquilla y atorníllela
hasta que quede apretada contra la parte
inferior de la bandeja. Inserte el tubo de desagüe en la boquilla para retener
Tubo De Desagüe
el agua. El tubo de desagüe se puede
Boquilla Roscada
quitar para desaguar el agua de la bandeja cuando sea necesario. Se puede conectar una manguera de jardín a la boquilla para
Arandela De Goma Bandeja
Tuerca
desaguar el agua hacia otra parte.
Fig. 5
· Conecte el tubo de abastecimiento de agua. Encuentre el abastecimiento de
agua más cercano. Utilice la válvula de la montura (fig. 6) para conectar la
tubería del cobre de 1/4 pulgada con el abastecimiento de agua fría de la
casa, o utilice una llave de paso y la válvula de agua
10
conectada con un grifo exterior (fig. 7). Coloque la tuerca y la férula en el
tubo y apriete bien la tuerca para impedir que gotee el agua. IMPORTANTE: No
conecte el abastecimiento de agua con ninguna aplicación de agua blanda. El
agua blanda disminuirá la vida del enfriador.
· Instale el flotador y conecte el tubo de agua al flotador. Instale el
flotador en el poste de esquina o el soporte según indica la figura 8. Si
tiene el modelo 3000DD/N31D, instale el flotador en el soporte solamente.
Véase la figura 9 para las instrucciones de instalar el flotador. Inserte el
flotador (1) por el agujero en el poste o el soporte. Instale la arandela de
hule (2) y la tuerca (3). Apriete la tuerca para que el flotador no de vuelta.
Ponga la tuerca (5) y la férula (4) en le línea de abastecimiento de agua (6).
Conecte la línea al flotador y apriete la tuerca hasta que no salga agua.
· Llene la bandeja con agua. Permita que se llene la bandeja con agua hasta
una altura de una pulgada por debajo del borde superior de la bandeja y ajuste
el flotador para que mantenga este nivel. Esto se puede lograr torciendo la
varilla del flotador para arriba o para abajo.
Tubería Del
Cobre
Válvula De
La Montura
Fig. 6
Abastecimiento De Agua Fría
Grifo
Válvula De Agua Ferula Tuerca
Llave De Paso
Fig. 7
Poste De Esquina
Soporte
Fig. 8
1
Flotador 6
5 4 3 2
Fig. 9
· Nivele los canales de agua. Ponga a funcionar la bomba hasta saturar de agua
los filtros. Luego revise cada canal para ver si la distribución del agua es
pareja. Si no es así, afloje los tornillos de ajuste y nivele cada canal.
Vuelva a apretar los tornillos. Compruebe que todos los filtros hayan quedado
saturados de agua y que no contengan áreas secas o roturas.
Sistema de Purga
Recomendamos instalar la sistema de purga para aumentar la vida del enfriador.
La sistema de purga es diseñada prevenir la acumulación de escama en el agua
quitando continuamente una cantidad pequeña del agua en la bandeja.
· Instale la te y tubo de pur-
ga. Véase la figura 10. Corte
el tubo del bomba e inserte Tubo De Bomba
los extremos estriados de la te a cada uno extremo
Te De Purga Tubo De Purga
cortado del tubo. Instale el tubo de purga insertando un
Reductor Tubo De Desagüe
extremo sobre la te y el otro
extremo pasando hacía afue-
ra del enfriador por medio
Fig. 10
del tubo de desagüe.
Nota: Está provisto con un reductor de flujo de agua lo cual, si desea,
se puede instalar en el tubo de purga para restringir la cantidad del agua
purgado. La cantidad de agua purgado depende de la calidad de agua
en su área. Comience con 1 a 2 galones por hora y aumente si está
necesitado.
Amperio Y Tensión De La Correa
Esta unidad viene equipada de una polea ajustable que permite ajustar la
velocidad del ventilador segun la capacidad del motor en diferentes sistemas
110503-1
de conductos. Es importante que la polea del motor sea ajustada al tamaño correcto para asegurar el máximo rendimiento sin dañar el motor. Siga cuidadosamente estas instrucciones.
· Ajuste la polea del motor. Después de instalar el enfriador completo, ajuste la polea al diámetro mínimo y ajuste la tensión de la correa. Vea la sección de mantenimiento para ajustar la tensión de la correa.
· Poner en marcha la unidad. Instale todas las rejas con los filtros, prenda la bomba y permita que siga funcionando hasta que todos los filtros estén mojados.
· Revise el amperio. Con los filtros mojados y la unidad en funcionamiento, revise el amperio del motor con un medidor de amperio.
· Ajuste la polea si es necessario. Si la lectura de amperio es menos
del valor especificado del motor, apague la unidad y quite la reja con
el filtro. Desconecte el motor dentro de la caja para protegerse en caso
de que alguien intente poner en marcha el enfriador mientras usted está
trabajando. Esto hay que hacerlo por su propia seguridad. Ajuste la
polea a un diámetro mas grande y vuelva
a ajustar la tensión de la banda. Conecte
el motor, coloque la reja y compruebe de nuevo el amperio. Repita estos pasos hasta obtener la lectura de amperio correcta. El
Disminuir Amperio
incrementar el diámetro de la polea, incre-
menta también el amperio; el disminuir el diámetro de la polea, disminuye también el
Fig. 11
amperio (véase fig. 11).
PRECAUCIÓN: No permita que funcione esta unidad si toma
mas amperio del que se indica la placa del motor.
NOTA: No se debe intentar la instalación completa de esta unidad sin la ayuda de un electricista o alguien que sepa medir el amperio. Si usted no sigue esta instrucción, podrá ser anulada su garantía.
Mantenimiento
ADVERTENCIA: Antes de hacer cualquier mantenimiento, compruebe que la
corriente esté apagada. Al quitar una reja, desconecte el motor y la bomba
dentro de la caja. Esto es por su seguridad.
Puesta En Marcha En La Primavera
· Cambie los filtros. Debe cambiar los filtros de paja una o dos veces durante
cada temporada, según la duración de ésta. Al principio y a mediados de la
temporada, un filtro limpio es más absorbente y eficiente y producirá un mayor
volumen de aire frío.
· Limpie la bomba. Es necesario limpiar la bomba una vez al principio de cada
año. Por su propia seguridad, apague la unidad y desconecte el
motor y la bomba. Quite el sujetador de plástico de la montura y jale la bomba, deslizándola hacia
Quite La Base
usted. Quite la base de la bomba
(véase fig 12). Limpie la bomba.
Dé le vuelta a la hélice para ve-
rificar que se mueve libremente.
hélice
Quite el pico de la bomba y vea si está obstruido. Después de lim-
Fig. 12
piar, reinstale la base en la bomba.
Presione firmemente para asegurarse de que es segura. Vuelva a colocar
la bomba en la unidad y fíjela en su montura con el sujetador de plástico.
Esto impedirá que se caiga la bomba al agua, lo que dañaría el motor.
No se olvide de volver a conectar el tubo de agua a la bomba.
· Lubrique los cojinetes. Los cojinetes de la rueda y el motor del venti-
lador deben ser lubricados usando unas gotas de un aceite no detergente
de densidad 20/30 una vez al año. No obstante, los motores sin tuberías
para aceite no necesitan ser lubricados. Estos motores son lubricados
en la fábrica de por vida y no requieren nunca ninguna lubricación.
PRECAUCIÓN: No lubrique demás. El agregar demasiado aceite
puede ocasionar que se queme el motor, a causa del aceite entrando al
interior del motor.
3 Libras
· Compruebe la tensión de la
3/4 Pulgadas
banda. Una fuerza de 3 libras debe desviar la banda 3/4 pulgadas (véase fig. 13). Ajuste la banda si es necesario.
Fig. 13
· Compruebe la válvula de desahogo para verificar que no está obstruida.
Preparar La Unidad Para El Invierno
· Drene el agua. Drene siempre toda el agua de la unidad y del tubo de
abastecimiento de agua cuando no use el enfriador durante períodos
prolongados, especialmente al fin de la temporada. El tubo debe quedarse
desconectado del enfriador y del abastecimiento de agua para que no lo
congele.
· Desconecte el motor y la bomba. Cuando no se utiliza el enfriador por
períodos extendidos, desconecte el motor y la bomba dentro del enfriador.
· Cubra la unidad. Para proteger y alargar la vida útil del acabado, se
sugiere cubrir el enfriador durante períodos largos cuando no sea utilizado.
Si usted sigue estas sugerencias en cuanto a instalación, operación y
mantenimiento, podrá disfrutar de muchos años de servicio eficiente y
satisfactorio de este enfriador. Si desea más información, su concesionario
tendrá mucho gusto en ayudarle con respecto a cualquier duda o pregunta.
Bomba
Alto Bajo Común Tierra
Negro Rojo Blanco Verde
Motor Del Ventilador
110503-1
120 Voltios
Esquemas Del Cableado
Azul/Negro Blanco Marrón Naranja Verde
Negro Rojo Blanco Naranja Verde
Bomba
Alto Bajo Común
Tierra
A Interruptor
= Empalme De Plástico
Bomba
Alto Bajo Común Tierra
Negro Rojo Naranja Verde
Motor Del Ventilador
240 Voltios
Azul/Negro Blanco Marrón Naranja Verde
Negro Rojo Blanco Naranja Verde
Bomba
Alto Bajo Común Tierra
A Interruptor
= Empalme De Plástico
11
La Localización De Averías
Problema Causa Posible
Remedio
No arranca o no sale aire
1. No llega corriente · Fusible fundido · Cortacircuito desactivado
· Cable eléctrico dañado 2. Banda muy floja o
apretada 3. Motor recalentado · Banda muy apretada
· Cojinetes de la rueda están secos
· Diámetro de la polea del motor demasiado grande
4. Motor parado
1. Revise la corriente · Cambie el fusible · Restablecer el cortacir-
cuito · Reemplace el cable 2. Ajuste la tensión de la
banda 3. Determine la causa · Ajuste la tensión de la
banda · Lubrique los cojinetes
· Ajústela al diámetro correcto
4. Cambie el motor
Sale poco aire cuando la unidad está funcionando
1. Insuficiente abertura para que salga el aire
2. Poca tensión en la banda
3. Filtros obstruidos 4. Agua insuficiente en los
filtros
1. Abra las ventanas o las puertas para aumentar el flujo de aire
2. Ajuste la tensión o cambie la banda
3. Cambie los filtros 4. Limpie el sistema de dis-
tribución y los agujeros del canal
Enfriamiento inadecuado
1. El agotamiento del aire es inadecuado
2. Los filtros no están mojados
· Filtros obstruidos · Filtros agujereados
· Agujeros de los canales obstruidos
· Bomba no funciona
1. Abra más las ventanas o puertas
2. Revise la distribución de agua
· Cambie los filtros · Acomode la paja en el
filtro · Límpielos
· Cámbiela o límpiela (Desconecte la unidad)
Problema Causa Posible
Remedio
Motor se apaga 1. Voltaje deficiente y se enciende 2. Demasiada tensión en la
banda 3. Eje del ventilador
atorado
4. Cojinetes secos 5. Diámetro de la polea del
motor demasiado grande dando por resultado sobrecarga del motor
1. Compruebe el voltaje 2. Ajuste la tensión de la
banda 3. Lubrique o cambie los
cojinetes (Desconecte la unidad) 4. Lubrique los cojinetes 5. Ajuste la polea
para no exceder el grado a carga plena del amperio del motor
Hace Ruido
1. Cojinetes secos 2. Rueda roza contra caja
de la rueda 3. Partes sueltas
1. Lubrique los cojinetes 2. Inspeccione y alinee
(Desconecte la unidad) 3. Apriételas
Demasiada 1. Insuficiente salida de aire humedad en la casa
1. Abra las puertas o las ventanas
Olor a encerrado, olor desagradable
1. Agua estancado en la unidad
2. Los filtros tienen moho o son obstruidos.
3. Los filtros son secos
· Agujeros del canal tapados
· Bomba no trabaja adecuada
1. Desagüe y limpie los filtros
2. Cambie los filtros
3. Revise la distribución de agua
· Límpielos
· Reemplace o limpie la bomba (Desconecte la unidad)
El agua está 1. El flotador no se ajusta
drenando sobre correctamente
el tejado.
2. El montaje de desagüe se
está escapando
1. Ajuste el flotador 2. Apriete la tuerca y el
tubo de desagüe
Registre su producto en línea a: www.championcooler.com/eac /onlineregistration-eac.htm
Garantía Limitada
La presente garantía se extiende al comprador original de un enfriador evaporativo instalado y utilizado bajo condiciones normales. No cubre daños ocurridos por accidente, descuido o abuso por parte del propietario. No autorizamos que ninguna otra persona o representante asuma por nosotros cualquier otra o diferente responsabilidad en relación con este producto.
Términos y Condiciones De La Garantía Durante Ocho Años a partir de la fecha de compra, nosotros reemplazaremos la base original del enfriador en caso de que goteara agua debido a oxidación.
Durante Un Año a partir de la fecha de compra, reemplazaremos cualquier componente original proporcionado por Champion Cooler que falle debido a cualquier defecto de material o mano de obra en la fábrica solamente.
Exclusiones De La Garantía No somos responsables por reemplazar los filtros del enfriador. Estos son componentes desechables y deben cambiarse periódicamente. No somos responsables por daños que resulten a consecuencia de alguna falla de funcionamiento.
No somos responsables por cualquier daño producido por el uso de suavizadores de agua, productos químicos, materiales desincrustantes, envolturas de plástico, o si se usa en esta unidad un motor de mayor potencia de la que se indica en la placa de número de serie.
No somos responsables por el costo del servicio para diagnosticar la causa del problema ni por la mano de obra necesaria para reparar y/o reemplazar piezas.
Como Obtener Servicio Bajo Esta Garantía Póngase en contacto con el concesionario que le vendió el enfriador. Si por alguna razón usted no queda satisfecho con la respuesta por parte del Concesionario, comuníquese con el departamento de servicio al cliente: 5800 Murray Street, Little Rock, Arkansas 72209. 1-800-643-8341. Correo electrónico: info@championcooler.com.
Esta garantía limitada se aplica al comprador original solamente.
12
110503-1
References
- pregunta.de jetzt kaufen!
- Serie.no | Størst på tegneserier
- Repair Your Grill: Shop Replacement Parts for 24,880 Models
- Essick Evaporative Cooler Parts - Select From 70 Models
Read User Manual Online (PDF format)