ESSICKAIR CS75 Evaporative Air Cooler Installation Guide
- July 11, 2024
- ESSICKAIR
Table of Contents
ESSICKAIR CS75 Evaporative Air Cooler
INSTALLATION OF EVAPORATIVE COOLERS
PREPARATION
- All electrical and duct work must comply with local and federal codes.
- Make arrangements to get the cooler from ground to roof (crane, hoist, etc.).
LOCATION
- Cooler should not be mounted near exhaust openings or vent pipes where fumes and odors can be drawn into cooler.
- Ensure mounting surface is strong enough to support the cooler. Operating weight will be much heavier than shipping weight.
- Locate cooler so that fresh air is drawn in; air is not recirculated.
ROOF MOUNT UNITS
- Select the location, taking into account roof construction and duct requirements. If rafters are cut when the roof opening is cut, be sure to strengthen them.
- Purchase or construct a platform to provide a level, mounting surface for the cooler. Always mount the cooler high enough to allow easy access to the drain fitting.
- Measure cooler or use the spec sheet to determine size of platform. Platform must be located so that the discharge opening of the cooler is in line with the ductwork. On pitched roofs, the platform frame may be covered with galvanized sheet steel or other weatherproof materials. An opening or removable panel must be left to allow access to the drain fitting. On down discharge coolers the duct should be fastened to the platform collar before cooler is set in place. The duct should have a standing flange for the cooler discharge opening to fit. Flash and seal the duct and roof opening to provide weather tightness.
CAUTION : TO AVOID RISK OF FIRE, ELECTRICAL SHOCK, OR SERIOUS PERSONAL
INJURY, BE SURE TO DISCONNECT POWER FROM UNIT BEFORE CLEANING OR SERVICING.
WARNING : TO REDUCE THE RISK OF FIRE OR SHOCK; DO NOT USE THIS FAN WITH
ANY SOLID STATE SPEED CONTROL DEVICE.
DUCT WORK
- The most important rule to follow when designing duct work is: AN EVAPORATIVE COOLER DEPENDS UPON A LARGE VOLUME OF AIR COMING OUT OF THE DUCT WORK AT HIGH VELOCITY IN ORDER TO COOL PROPERLY.
- Do not “reduce” the discharge opening of the cooler.
- Do not undersize the duct work and make it much smaller than the discharge opening. (In most cases, air conditioning duct work is too small for coolers.)
- Extra long ducts cause static pressure and will reduce airflow. They also pick up heat and diminish the effect of the cooled air.
- The motor pulley may be adjusted to compensate for ductwork.
- Sharp or abrupt bends hinder airflow.
- Poorly designed ceiling diffusers will ruin a successful installation. Install diffusers that are designed for use with evaporative coolers.
MOTOR INSTALLATION
After cooler is in place and level, remove the motor from the box and inspect for shipping damage. Ensure that the motor voltage, phase and horsepower are correct. Mount motor on motor mount as shown.
CS75/85, CD75/85
Secure motor to mount using the mounting straps provided. When using motors
with a 143T or 145T frame, remove the yolks from the motor mount and bolt the
motor to the motor mount using the slots provided.
CS11/16, CD11/16 & CD21
Mount the motor using the slots that align the motor pulley and blower pulley.
BELT ADJUSTMENT
An improperly adjusted belt will greatly shorten motor life. A deflection of
¾” with finger force will indicate proper adjustment. (Figure 1) Do not use
the motor pulley to adjust belt tension. Always use the motor mount to adjust
the belt. (Figure 1)
MOTOR PULLEY ADJUSTMENT
Before installing the motor pulley, loosen the set screw on the back side of
the pulley and turn the outside jaw of the pulley until it is fully closed.
Position the set screw over the closest flat spot in the thread and then open
the outside jaw of the pulley 4 or 5 turns. Position the set screw over the
closest flat spot in the thread and retighten the set screw. Place the pulley
on the motor shaft and tighten the front set screw. See figure 2. The CD21
coolers are equipped with double groove pulleys.
OVERFLOW PIPE INSTALLATION
Place the rubber washer onto the drain bushing. Slide the bushing through the
drain opening, in the cooler bottom, from the top side. Screw the nut onto the
bushing from under the cooler.
CAUTION : DO NOT HOOK THIS COOLER TO A WATER SOFTENER. THIS WILL VOID THE
WARRANTY.
WATER CONNECTION
CD75/85: Mount the float in the splash baffle as shown. CS75/85: Mount the
float in the float bracket. Route the ¼” water line through the corner post as
shown. Place the compression nut and ferrule onto the water line. Slide the
water line into the float and tighten the compression nut. See figure 4. As
the figure shows, the water level should remain ½” below the top of the
overflow tube. A screw is provided in the float to adjust water level; or the
float rod may be bent to adjust the level. 11/16 & 21: The float mounts in a
hole provided in the corner post (down draft) or front panel (side draft).
BLEEDOFF
In hard water areas, a bleed off kit may be installed to dispose of small
amounts of mineralized water allowing fresh water to replace it.
ELECTRICAL POWER
- The installation of electrical wiring must conform to all local and federal codes and should be done by a certified electrician.
- Connecting the motor and/or pump to the wrong voltage will void the warranty.
Warning : To avoid risk of electrical shock, disconnect the power before opening or attempting service on this unit.
Notice to Installer: The motor amperage must be set as close as possible to motor nameplate amps without the pump running.
WIRING DIAGRAMS
A 4” j box has been provided (75/85), in the unit, for wiring purposes. No
other wiring components will be provided. Single phase: one and two speed.
Three phase; one and two speed. Motor starter to be equipped with overload
relay sized to accommodate motor full load amps. Motor starters and overloads
are not supplied with units.
START UP
After installing cooler and before filling with water:
- Open windows and doors or other exhaust openings in building.
- Turn on cooler and check amperage at the incoming white lead, using clamp on ammeter. If amperage reads above motor name plate, refer to the motor pulley adjustment instructions (page 2) and open the pulley ½ turn. Restart cooler and recheck amperage. If amperage reads below motor name plate, close the pulley ½ turn. Restart cooler and recheck amperage.
- Turn on water to cooler and ensure that connections do not leak.
- Fill pan to ½” below top of overflow tube and ensure that the float cuts off water completely.
- Turn the switch to cool and check that water is coming from the water trays and that the pads are wetting evenly. There are screws at the top of the louvers to level the water trays.
MAINTENANCE
CAUTION : Turn off all electrical power to this unit before opening or
attempting any service. Occasionally inspect your cooler for leaks, loose
belt, blocked water lines, correct
belt alignment or excessive residue buildup on the pads. Inspect cabinet for
rust. If rust spots appear, sand and paint with a high-grade, corrosion
resistant paint.
OILING
Lube the blower bearings twice per year. Use SAE 20W or 30W, non-detergent oil
on bearings with oil cups and standard bearing grease on ball bearings. Oil
the blower motor if it is equipped with oil holes. Some motors are permanently
lubricated at the factory.
PAD REPLACEMENT
It is best to change pads at the end of the season. When old pads (covered by
minerals and salts) are left in the cooler during the wet winter months, there
is a greater possibility for corrosion.
- Remove the louver from the cooler.
- Unhook pad retainers from the sides of the louver and remove.
- Remove the old pad and discard.
- Clean any dirt or sediment that has built up on louver. Inspect the water tray and clean any dirt or sediment that has built up in the water slots. If louver has rust spots, sand and paint with a high-grade, corrosion resistant paint.
- Tuck new pad into louver, ensuring that there are no gaps to allow hot air to bypass the pad
- Replace the pad retainers.
LIMITED WARRANTY
This warranty is extended to the original purchaser only. It does not cover damages incurred during shipping or through accident, neglect, or abuse by the owner. Essick Air Products does not authorize any person or representative to assume any other or different liability in connection with this cooler.
TERMS AND CONDITIONS OF WARRANTY
The BOTTOM PAN is guaranteed against leakage due to rusting out for Five
Years. All other original parts provided by Essick Air Products are warranted
against defects in material or factory workmanship for One Year.
EXCLUSIONS FROM THE WARANTY
- Essick Air Products is not responsible for incidental or consequential damage resulting from any malfunction.
- Essick Air Products is not responsible for any damage occurring from the use of water softeners, chemicals, descale material, or if a higher horsepower motor than what Essick Air Products recommends is used in the unit.
- Essick Air Products is not responsible for the cost of service calls to diagnose cause of trouble, or labor charge to repair and/or replace parts.
HOW TO OBTAIN SERVICE UNDER THIS WARRANTY
Contact the Dealer where you purchased the evaporative cooler. If for any
reason you are not satisfied with the response from the dealer, contact
Customer Service Department: Essick Air Products Inc. 5800 Murray Street,
Little Rock, Arkansas 72209.
Phone 1-800-643-8341
CS75/85 & CD75/85 REPLACEMENT PARTS / REPUESTOS
ITEM
|
DESCRIPTION
|
DESCRIPCIÓN
| CS75/85| CD75/85
---|---|---|---|---
PART NO. NO. DE REF.| QTY. CAN.| PART NO. NO. DE REF.| QTY. CAN.
1| TOP| SUPERE| 70410| 1| 70380| 1
2| BOTTOM| FONDO| 70411| 1| 70398| 1
3| FRONT| FRENTE| 70414| 1| |
4| LEFT CORNER POST| POST ESQUINERO LEFT| 70475| 1| |
4| RIGHT CORNER POST| POST ESQUINERO RIGHT| 70384| 1| |
4| CORNER POST| POSTE ESQUINERO| | | 70481| 4
5| BLOWER HOUSING| CAJA DEL VENTILADOR| 70402| 1| 70402| 1
6| CUTOFF| TAPA DE LA CAJA DEL VENTILADOR| 70395| 1| 70395| 1
7| MOTOR MOUNT| MONTAJE DEL MOTOR| 70408| 1| 70408| 1
8| BEARING ANGLE| ANGULO PARA CHUMACERA| 70393| 2| 70393| 2
9| SPLASH BAFFLE| DEFLECTOR| | | 70444| 2
10| BLOWER WHEEL| EL SOPLADOR RUELA| 70403| 1| 70403| 1
11| BLOWER SHAFT| EJE DEL VENTILADOR| 70438| 1| 70438| 1
12| KEY| PASADOR| 589041| 2| 589041| 2
13| SET COLLAR| COLLAR FIJO| 501243| 2| 501243| 2
14| BEARING| CONJINETE| 583004| 2| 583004| 2
15| PULLEY| POLEA DEL VENTILADOR| 583035| 1| 583035| 1
16| LOUVER| LA REJILLA| 70385| 3| 70385| 4
17| WATER TRAY| LA AGUA EL BANDEJA| 70397| 3| 70397| 4
18| FILTER SET| FIJO DE FILTRE| 70485| 1| 70486| 1
19| PAD RETAINER| RELLENE RETENEDOR| 70396| 15| 70396| 20
*| LOUVER ASSEMBLY| JUEGO DE REJILLA| 70399| 3| 70399| 4
20| WATER DISTRIBUTOR| DISTRIBUIDOR DE AGUA| 70405| 1| 70404| 1
21| WATER TUBE HOLDER| EL TENEDOR DE CAÑO DE AGUA| 524304| 6| 524304| 8
22| FLOAT BRACKET| ABRAZADERA DEL FLOTADOR| 70413| 1| |
23| FLOAT VALVE| VÁLVULA FLOTADORA| 524198| 1| 524198| 1
24| PUMP| BOMBA| 506605| 1| 506605| 1
25| PUMP BRACKET| ABRAZADERA DE LA BOMBA| 70488| 1| 70488| 1
26| WATER HOSE| MANGUERA DEL AGUA| 598400| 60”| 598400| 60”
27| OVERFLOW KIT| EQUIPO DE DESBORDIMENTO| 515100| 1| 515100| 1
28| DUCT FLANGE| LA BRIDA| 70419| 1| |
29| BOTTOM DUCT FLANGE| LA BRIDA BOTTOM| 70576| 2| |
30| BLOWER BRACE| ABRAZADERA DEL VENTILADOR| 70483| 2| 70394| 4
Motor, pulley and belt sold separately. Louver assembly includes louver, water tray, pad and El juego de rejilla incluye la rejilla, la charola para agua, pad retainers.
CS75/85 & CD75/85 REPLACEMENT PARTS / REPUESTOS
To order replacement parts, please call “The Cooler Hotline” at 1-800-643-8341. To ensure prompt service, have the following information available.
- Cooler Model #_____
- Manual # and Revision Date___
- Purchased From_____
CS11/16, CD11/16 & CD21 REPLACEMENT PARTS / REACCIONES
To order replacement parts, please call “The Cooler Hotline” at 1-800-643-8341. To ensure prompt service, have the following information available.
- Cooler Model #__
- Manual # and Revision Date____
- Purchased From_____
CS11/16, CD11/16 & CD21 REPLACEMENT PARTS
ITEM
|
DESCRIPTION
|
DESCRIPCIÓN
| CS11/16| CD11/16 & CD21
---|---|---|---|---
PART NO. NO. DE REF.| QTY. CAN.| PART NO. NO. DE REF.| QTY. CAN.
1| FRONT| FRENTE| 70697| 1| |
2| BOTTOM| FONDO| 70702| 1| 70681| 1
3| BLOWER HOUSING| CAJA DEL VENTILADOR| 70703| 1| |
4| CUTOFF| TAPA DE LA CAJA DEL VENTILADOR| 70705| 1| 70694| 1
5| TOP| SUPERE| 500220| 1| 500220| 1
6| MOTOR MOUNT| MONTAJE DEL MOTOR| 70687| 1| 70687| 1
7| WATER DISTRIBUTOR| DISTRIBUIDOR DE AGUA| 500713| 1| 500712| 1
8| BLOWER BRACE| ABRAZADERA DEL VENTILADOR| 500852| 2| 500852| 2
9| CENTER POST| POSTE CENTRO| 501466| 3| 501466| 4
10| PAD RETAINER| RELLENE RETENEDOR| 500603| 6| 500603| 8
11| FILTER| FILTRE| 524093| 6| 524093| 8
12| LOUVER| LA REJILLA| 501352| 6| 501352| 8
13| WATER TRAY| LA AGUA EL BANDEJA| 500677| 6| 500677| 8
*| LOUVER ASSEMBLY| JUEGO DE REJILLA| 503396| 6| 503396| 8
14| CORNER POST| POST ESQUINERO| 500098| 1| 500098| 2
15| WATER HOSE| MANGUERA DEL AGUA| 598400| 60”| 598400| 60”
16| PUMP BRACKET| ABRAZADERA DE LA BOMBA| 70488| 1| 70488| 1
17| OVERFLOW KIT| EQUIPO DE DESBORDIMENTO| 515100| 1| 515100| 1
18| FLOAT VALVE| VÁLVULA FLOTADORA| 524198| 1| 524198| 1
19| SET COLLAR| COLLAR FIJO| 501242| 2| 501242| 2
20| BLOWER WHEEL| EL SOPLADOR RUELA| 70640| 1| 70640| 1
21| BLOWER SHAFT| EJE DEL VENTILADOR| 70672| 1| 70672| 1
22| KEY| PASADOR| 589041| 2| 589041| 2
23| PULLEY| POLEA DEL VENTILADOR| 583095| 1| 583095| 1
24| BEARING| CONJINETE| 583005| 2| 583005| 2
25| BEARING ANGLE| ANGULO PARA CHUMACERA| 514498| 2| 514498| 2
26| BLOWER HOUSING| CAJA DEL VENTILADOR| | | 70688| 1
27| MOTOR MOUNT (CD21)| MONTAJE DEL MOTOR (CD21)| | | 512491| 1
28| SPLASH BAFFLE| DEFLECTOR| | | 501464| 2
29| PUMP| BOMBA| | 1| | 1
References
- Repair Your Grill: Shop Replacement Parts for 24,880 Models
- Essick Evaporative Cooler Parts - Select From 70 Models
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>