Nobol PP0002 PhysioPedal Motorized Arm and Leg Exerciser User Manual
- July 10, 2024
- Nobol
Table of Contents
User Manual Plug-In/ Resistance
Hello
Welcome
Safety Instructions
When using The PhysioPedal, basic precautions should always be followed,
including the following:
Read all instructions before using The PhysioPedal.
Warning
To Reduce the risk of burns, fire, electric shock, or injury to persons:
Disconnect the charger from the PhysioPedal when not in use, and before
putting on or taking off parts.
Use The PhysioPedal only for its intended use as described in this manual.
Do not use attachments not recommended by the manufacturer.
- Never operate The PhysioPedal if it’s damaged, or not working properly, if it has been dropped or damaged, or dropped into water.
- Return The PhysioPedal to a service center for examination and repair.
- Never drop or insert any object into any opening.
- Do not use it in the rain.
- Do not operate where aerosol (spray) products are used or where oxygen is administered.
- For household use only.
This appliance can be used by children aged 8 years and above and by individuals with reduced physical, sensory, or mental capabilities, or a lack of experience and knowledge, if they have been given supervision or instruction regarding the safe use of the appliance and understand the hazards involved. Children should not play with the appliance. Cleaning and user maintenance should not be performed by children without supervision. The appliance is intended to be used only with the power supply unit provided with it.
What’s in the box
A. PhysioPedal Body
B. Base
C. Wireless Remote
D. Plug-In Cable & Adapter
E. Oversized Pedals x 2
F. Handles x 2
G. Base Screws x 4
H. Wrench
Specifications
Product Model: PP0002
Rated Power: 72W
Product Size: 20.2 x 10.6 x 14.6 in.
Output: 24V=3A
Input: 110~220V AC
Net Weight: 8.61 Kg. | 19 Lbs.
Gross Weight: 11.25 Kg. | 24.8 Lbs.
Body: 5.4 Kg. | 12 Lbs.
Handles: 0.3 Kg. | 0.7 Lbs.
Comfort Pedals: 1.6 Kg. | 3.6 Lbs.
Cleaning and Storing
Make sure the power is OFF. Use a damp, clean cloth and gently wipe your
PhysioPedal. Store in a clean, cool, dry place, not in direct sunlight, when
not in use. Any other servicing should be performed by an authorized service
representative.
Features
| Tilt-sensitive safety
feature
10° angle triggers alarm and auto-stops motor
---|---
| Quick Release Pedal
Pull the shaft and easily insert or release the pedal
| Motor
Medical grade DC electric motor
| Ergonomic Base
Enhanced stability, lightweight design
| Remote Control
Senior friendly Intuitive Interface
| Interactive Screen
Tracking and reporting of all usage, calories, distance, time used
Remote Control / Display
A. Start/Stop
B. Decrease Speed
C. Increase Speed
D. Menu
E. Timer
F. Switch Direction| A. Rotations per minute
B. Timer
C. Timer Countdown
D. Calories
E. Steps
Remote Control Buttons
| Press the Start/Stop button once to start the Pedals or Handles to move.
Press Start/Stop button again to stop.
---|---
| The unit will start a slow speed of 30 RPM, to increase the speed press the
Plus button.
To decrease the speed press the Minus button.
| To set the timer, press the Clock button.
The PhysioPedal will start at 10 minutes.
Each press will increase the time by 10 minutes up to 90 minutes total.
| To change between Time, Calories, and Steps, press the Menu button.
| To switch the rotational direction of pedals, push the Two Arrows button.
If the remote control stops working, you may need to reconnect the remote control to your PhysioPedal. Turn the PhysioPedal ON then, on the remote control, press and hold the Switch Direction button for 3 seconds until you hear a beep.
Getting Started
Assembly
To assemble the PhysioPedal, use the Tool to screw the 4 Screws to attach
the base to the body of the PhysioPedal.
Attach the Pedals or Handles into the Cranks. Switch from Pedals to Handles
with a simple action, simply pull the knob back and slide the Pedals or
Handles in or out .
Plug the Power Cord into the Front of the Unit, screw until hand tight.
Put the Remote Control over the magnetic screen.
Resistance Mode
(Default Mode)
| To activate the PhysioPedal, ensure it is connected to an electrical
outlet. Press the Power Button located on the front of the unit to initiate
power.
---|---
| When activating the
PhysioPedal, start at Level I. Sit comfortably and position both feet on the
pedals. Begin pedaling.
| To increase resistance, simply use the Remote Control’s + button and select
your preferred resistance level.
Assisted Mode
| To activate Assisted Mode, simply press the play button on the Remote
Control.
To increase speed in the assistance level, press the + button on the Remote
Control to your preferred level. Sit comfortably and position both feet on the
pedals.
Begin pedaling.
---|---
| For upper body exercise, place the PhysioPedal on an elevated platform or
table, and position your hands on the grips.
| Upon
completion, simply turn off the PhysioPedal by pressing the Switch OFF button.
Troubleshooting
If you encounter any issues while using this product, please consult the provided tips and troubleshooting methods. If the problem persists, power off the device.
Use Failure | The reason | Solution |
---|---|---|
Product Not Functioning (Cannot be Turned On) | The power switch is in the off | |
state | Put the power switch on | |
The adapter is not powered on | Power on the adapter and check if the DC |
interface is in good contact
Remote control not working| The battery insulation sheet has not been removed|
Remove the insulation sheet
The battery of the remote control is depleted| Replace with a new battery
After turning on, the buzzer will sound an alarm and display| The product is
tilted or has not been positioned on a flat surface| Place the product on the
flat ground
Product Stops during operation| Incorrect setting for the timer| Press the
power button to restart
Stop working during use, alarm display| When the pedaling speed exceeds the
set RPM, an overspeed alarm is activated, which is part of the normal
overspeed alarm function| Reducing pedal speed will restore normal operation
Warranty
Contact our customer service by emailing us at
cs@Neobol.com to start your warranty period.
If within one year from the date of purchase, this device fails due to a
defect in material or workmanship, Nobol Inc. will repair or replace the
device or necessary components, free of charge.
This warranty excludes:
A. Damage caused by accident, abuse, mishandling, or transport
B. Units subjected to unauthorized repair
C. Damage exceeding the cost of the product
D. Deterioration of the delivered product resulting from abnormal storage
and/or safeguarding conditions on the client’s premises
E. Products taken apart or repaired by anyone other than an authorized service
representative
F. Failure to provide the dated proof of purchase and serial number on your
device
G. Products purchased from an unauthorized retailer
H. Please do not try and repair the unit yourself, as this will void your
warranty
*Some states and countries do not allow a limitation of damages, so the foregoing limitation may not apply to you. This warranty guarantees specific legal rights, but other rights may vary between countries and from state to state. This warranty service is available through the operating policies and procedures of Nobol Inc., and all Nobol international distributors. If you are a client, please contact the appropriate Nobol business entity dealer, or retailer, from whom you directly purchased the device for warranty and return authorization procedures. This warranty is initiated and executed by Nobol Inc.
8935 Research Drive, Irvine, CA 92618
Designed with ❤ in California by Nobol, Inc. Assembled in China
Documents / Resources
|
Nobol PP0002 PhysioPedal Motorized Arm and Leg
Exerciser
[pdf] User Manual
PP0002 PhysioPedal Motorized Arm and Leg Exerciser, PP0002, PhysioPedal
Motorized Arm and Leg Exerciser, Motorized Arm and Leg Exerciser, Arm and Leg
Exerciser, Leg Exerciser
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>