COOL15-100 Built In Dryers Instruction Manual

July 9, 2024
COOL

COOL15-100 Built In Dryers

Code

9828093120| 00
Edit. 05/2017

INSTRUCTION AND MAINTENANCE MANUAL
DRYERS
COOL15-100 (C0 – C6)

READ THIS MANUAL CAREFULLY BEFORE CARRYING OUT ANY OPERATIONS ON THE DRYER.

CONTENTS

PART A: INFORMATION FOR THE USER

UNPACKING

  1. GENERAL CHARACTERISTICS 12.0 INSTALLATION

  2.  INTENDED USE 13.0 DIMENSIONS AND TECHNICAL DATA

  3.  OPERATION 14.0 MACHINE ILLUSTRATION

  4. GENERAL SAFETY STANDARDS 15.0 PARTIAL ROUTINE MAINTENANCE

  5. DESCRIPTION OF DANGER SIGNALS 16.0 SCRAPPING THE DRYERS

  6. DANGER ZONES 17.0 TROUBLE-SHOOTING AND EMERGENCY REMEDIES

  7. SAFETY DEVICES PART B: INFORMATION RESERVED FOR TECHNICALLY SKILLED
    PERSONNEL

  8. POSITION OF PLATES 18.0 STARTING UP

  9. DRYERS ROOM

  10. TRANSPORT AND HANDLING

ATTENTION: THERE IS A COPY OF THE WIRING DIAGRAM INSIDE THE ELECTRIC PANEL
ADDRESSES OF ASSISTANCE CENTRES
In the event of breakdown or malfunction of the dryer, switch it off and do not tamper with it. If repairs are needed, apply only to a technical assistance centre approved by the manufacturer and insist on the use of original spare parts. Failure to comply with the above may endanger the safety of the machine.

INTRODUCTION

Keep this manual with care for future consultation; the use and maintenance manual is an integral part on the dryer. Read this manual carefully before carrying out any operations on the dryer.
The installation of the dryer and all operations involving it must be performed in conformity with the regulations in force concerning electric plants and personal safety.

CHARACTERISTICS AND SAFETY PRECAUTIONS

BEFORE REMOVING THE PROTECTIVE GUARDS TO CARRY OUT ANY MAINTENANCE ON THE MACHINE, SWITCH OFF THE ELECTRIC
POWER SUPPLY AND DISCHARGE THE RESIDUAL PRESSURE INSIDE THE UNIT.
ALL WORK ON THE ELECTRIC PLANT, HOWEVER SLIGHT, MUST BE CARRIED OUT BY PROFESSIONALLY SKILLED PERSONNEL.
The manufacturer does not accept responsibility for damage caused as a result of negligence of failure to abide by the instructions given above.

  • THIS MACHINE IS NOT SUITABLE FOR EXTERNAL INSTALLATION
  • THIS MACHINE CORRESPONDS TO THE ESSENTIAL SAFETY REQUIREMENTS FORESEEN FROM THE EUROPEAN STANDARD (2006/42 CE).
  • THE LUBRICATING LIQUIDS AND OTHER EVENTUAL FLUIDS MUST NOT BE DISCHARGED IN THE ENVIRONMENT. THESE POLLUTING AND HAZARDOUS PRODUCTS MUST COMPULSORY BE DISPOSED BY CHARGING
  • AUTHORISED AND SPECIALISED FIRMS ACCORDING TO THE DIFFERENT TYPOLOGIES OF PRODUCT.
  • DIFFERENTIATE THE COMPRESSOR COMPONENTS ACCORDING TO THE DIFFERENT CONSTRUCTION MATERIALS (PLASTIC, COPPER, IRON, OIL FILTER, AIR FILTER ECC…)

GENERAL CHARACTERISTICS

The dryer is a chilling machine with direct expansion and dry evaporator.
The air to be dried is sent to the heat exchanger in which the water vapour present is condensed: the condensate gathers in the separator and is discharged outside through a steam trap.

INTENDED USE

The dryer has been built to dry the compressed air for industrial use. The dryer cannot be used in premises where there is a risk of fire or explosion or where work is carried out which releases substances into the environment which are dangerous with regard to safety (for example: solvents, inflammable vapours, alcohol, etc.).
In particular the appliance cannot be used to produce air to be breathed by humans or used on direct contact with foodstuffs. These uses are allowed if the compressed air produced is filtered by means of a suitable filtering system
(Consult the manufacturer for these special uses.)
This appliance must be used only for the purpose for which it was specifically designed. All other uses are to be considered incorrect and therefore unreasonable. The Manufacturer cannot be held responsible for any damage resulting from improper, incorrect or unreasonable use.

OPERATION

The gaseous refrigerant coming from the evaporator (4) is sucked by the refrigeration compressor (1) and it is pumped into the condenser (2). This one allows its condensation, eventually with the help of the fan (3); the condensed refrigerant passes through the dewatering filter (8) and it expands through the capillary tube (7) and goes back to the evaporator where it produces the refrigerating effect.Due to the heat exchange with the compressed air which passes through the evaporator against the stream, the refrigerant evaporates and goes back to the compressor for a new cycle.
The circuit is equipped with a bypass system for the refrigerant; this intervenes to adjust the available refrigerating capacity to the actual cooling load. This is achieved by injecting hot gas under the control of the valve (9): this valve keeps constant the pressure of the refrigerant in the evaporator and therefore also the dew point never decreases below 0 °C (32 °F) in order to prevent the condensate from freezing inside the evaporator. The dryer runs completely automatically.

DRYER FLOW DIAGRAM
COOL15-100-Built -In-Dryers- \(2\)

  1. REFRIGERANT COMPRESSOR 7) EXPANSION CAPILLARY TUBE
  2. CONDENSER| 8) REFRIGERANT FILTER
  3. MOTOR FAN| 9) HOT GAS BYPASS VALVE
  4. EVAPORATOR| 10) AIR-TO-AIR EXCANGER
  5. DEMISTER CONDENSATE SEPARATOR| 11) DEW POINT THERMOMETER
  6. IMPURITY TRAP| 12) CONDENSATE DRAIN

GENERAL SAFETY STANDARD

The appliance may be used only by specially trained and authorized personnel.
Any tampering with the machine or alterations not approved beforehand by the Manufacturer relieve the latter of responsibility for any damage resulting from the above actions.
The removal of or tampering with the safety devices constitutes a violation of the European Standards on safety.

ALL WORK ON THE ELECTRIC PLANT, HOWEVER SLIGHT, MUST BE CARRIED OUT BY PROFESSIONALLY SKILLED PERSONNEL.

DESCRIPTION OF DANGER SIGNALS

COOL15-100-Built -In-Dryers- \(3\)

DANGER ZONES COOL15-100-Built -In-Dryers- \(5\)

SAFETY DEVICES

  1. Cooling fan shield|
    ---|---
  2. Earth|

COOL15-100-Built -In-Dryers- \(6\)

POSITION OF PLATES

POSITION OF THE DANGER PLATES (Fig. 4)
The plates fitted on the compressor unit are part of the machine; they have been applied for safety purposes and must not be removed or spoiled for any reason.
Warning label Code 1079 9926 55 COOL15-100-Built -In-Dryers-
\(7\)

POSITION OF THE DATA PLATES (Fig. 4)

Ref. 2) “IN” Ref. 4) Identification plate
Ref. 3) “OUT”

DRYERS ROOM

FLOOR
The floor must be even and of industrial type; the total weight of the machine is shown in Fig. 5
Remember the total weight of the machine when positioning it.

VENTILATION
The choice of an appropriate room will prolong the life of your dryer; the room must be spacious, dry, well ventilated and free from dust. The operating conditions to be complied with are the following:

Min. room temperature: + 5 °C (41 °F) (compulsory)| Min. temperature of incoming air: 10 °C (50 °F)
---|---
Max. room temperature: + 40 °C (104 °F) (compulsory)| Max. working pressure: 16 bar (232 psi)
Max. temperature of incoming air: 50 °C (122 °F)|

 TRANSPORT AND HANDLING

The machine must be transported as shown in the following fig. 5.

UNPACKING

CUTTING THE METAL STRAPPING IS A DANGEROUS OPERATION, DO NOT ABANDON THE CUT PIECES IN THE ENVIRONMENT.

After removing the packing, ensure that the machine is unbroken and that there are no visibly damaged parts.
If you are in doubt, do not use the machine but apply to the manufacturer technical assistance service or to your dealer.
The packing material (plastic bags, polystyrene foam, nails, screws, wood, metal strapping, etc.) must not be left within the reach of children or abandoned in the environment, as they are a potential source of danger and pollution.Dispose of these materials in the approved collection centres.

INSTALLATION

POSITIONING
After unpacking the equipment and preparing the dryers room, put the machine into position, checking the following items:

  • ensure that there is sufficient space around the machine to allow maintenance (see Fig. 6).
  • ENSURE THAT THE OPERATOR CAN SEE THE WHOLE MACHINE FROM THE CONTROL PANEL AND CHECK THE PRESENCE OF ANY UNAUTHORIZED PERSONS IN THE VICINITY OF THE MACHINE.

ELECTRICAL CONNECTION

  • Check that the supply voltage is the same as the value indicated on the machine data plate.
  • Check the condition of the line leads and ensure that there is an efficient earth lead.
  • Ensure that there is an automatic cut-out device upstream for the machine against overcurrents, with a differential device ( Ref. 1 Fig. 6 ), wiring diagram.
  • ONLY PROFESSIONALLY SKILLED PERSONNEL MAY HAVE ACCESS TO THE ELECTRIC PANEL. SWITCH OFF THE POWER BEFORE OPENING THE DOOR OF THE ELECTRIC PANEL. COMPLIANCE WITH THE REGULATIONS IN FORCE CONCERNING ELECTRIC PLANTS IS FUNDAMENTAL FOR OPERATOR SAFETY AND FOR THE PROTECTION OF THE MACHINE.

CONNECTION TO THE COMPRESSED AIR NETWORK
Fit a manual interception valve between the machine and the compressed air network so that the dryer may be isolated during maintenance operations. Drainage of condensate Rif. 2 Fig. 7 (automatic) are led outside the machine with a flexible pipe that may be inspected.
Drainage must comply with the local regulations in force.
ALL DAMAGE DUE TO THE FAILURE TO COMPLY WITH THESE NDICATIONS CANNOT BE ATTRIBUTED TO THE MANUFACTURER AND MAY CAUSE INVALIDITY OF THE GUARANTEE CONDITIONS.

STARTING UP
See part B of this manual, Chpter 18.0

COOL15-100-Built -In-Dryers- \(8\)

DIMENSIONS AND TECHNICAL DATA COOL15-100-Built -In-Dryers-
\(9\)

COOLMOD DIMENSIONS mm (in)
L W
15-100 (C0-C6)

233 (9,17)

|

550 (21,6)

|

560 (22)

Refrigerant gas (1) GWP 100 (2)
R-134a 1300
(1) According to ISO 817
(2) According to EN-378-1
MODD. A
--- ---
15-65 (C0-C4) 1/2” GAS (CE)

1/2” NPT (cULus)

| 1/2” GAS (CE)

1/2” NPT (cULus)

75 (C5)| 3/4” GAS (CE)

3/4” NPT (cULus)

| 3/4” GAS (CE)

3/4” NPT (cULus)

100 (C6)| 1” GAS (CE)

1” NPT (cULus)

| 1” GAS (CE)

1” NPT (cULus)

COOL15-100-Built -In-Dryers- \(10\)

Reference conditions: Limit conditions:
Ambient temperature 25 °C (77 °F) Max. ambient temperature 40 °C (104 °F)
Inlet air temperature 35 °C (95 °F) Min. ambient temperature 5 °C (41 °F)
Working pressure 7 bar (101 psi) Max. inlet air temperature 50 °C (122 °F)
Max. working pressure 16 bar (232 psi)

MACHINE ILLUSTRATION

GENERAL LAY-OUT

COOL15-100-Built -In-Dryers- \(11\)

1 Refrigerant compressor
2 Condenser
3 Motor fan
4 Evaporator
5 Condensate drain
6 Hot gas by-pass valve
7 Refrigerant filter
8 Expansion capillary tube

COMMAND AND CONTROL PANEL
BEFORE CARRYING OUT THE OPERATION TEST, READ CAREFULLY AND ACQUIRE A GOOD KNOWLEDGE OF THE COMMAND

FUNCTIONS.

  1. Ref. 1) Dew point indicator
  2. Ref. 2) Stop – Running button

PARTIAL ROUTINE MAINTENANCE

BEFORE CARRYING OUT ANY MAINTENANCE JOBS IT IS OBLIGATORY TO STOP THE MACHINE AND DISCONNECT IT FROM THE
POWER MAINS AND FROM THE COMPRESSED AIR DISTRIBUTION NETWORK.

MAINTENANCE SCHEDULE
These maintenance intervals are recommended for work environments that are not dusty and are will ventilated. For particularly dusty environments, double the frequency of controls.

Each Week
Condensate drain: Clean the filter of the steam trap Each Monthly
Condenser: Clean the condenser fins to remove eventual dust.

CLEANING OF THE AUTOMATIC CONDENSWATER DISCARGER FILTER (Fig. 10)Clean the filter of the steam trap.

Proceed as follows:

  • Close the cock Ref. 1 Fig. 10
  • Release the pressure in the dryer by pressing the condensate drain “TEST” pushbutton locate on the steam trap Ref. 2 Fig. 10.
  • Switch off the machine by pressing the STOP button Ref. 3 Fig. 10
  • Turn on the supply automatic differential switch Ref. 4 Fig. 10

HOT PARTS INSIDE

  • Remove the panel Ref. 5
  • Remove the stopper Ref. 6
  • Remove the filter Ref. 7
  • Clean the filter Ref. 7 with a jet of air, working from inside to outside
  • Install the filter, fix the plug Ref. 7 – 6
  • Close the panel Ref. 5 COOL15-100-Built -In-Dryers- \(13\)

CLEANING THE CONDENSER (Fig. 10)
The condenser must be cleaned every month.

Proceed as follows:

  • Switch off the machine by pressing the STOP button Ref. 3 Fig. 10
  • Turn on the supply automatic differential switch Ref. 4 Fig. 10
  • Remove the panel Ref. 5 Fig. 10
  • Clean the condenser fins Ref. 1 with compressed air (Fig. 10) DO NOT USE WATER OR SOLVENTS
  • Close the panel Ref. 5 Fig. 10

 SCRAPPING THE UNIT

If the machine is to be scrapped, it must be dismantled into parts of the same material, to be disposed of according to the local regulations in force.
ALWAYS RESPECT THE REGULATIONS IN FORCE FOR DISPOSING OF OLD OIL AND OTHER POLLUTING MATERIALS SUCH AS INSULATING FOAM, ETC.

 TROUBLESHOOTING AND EMERGENCY REMEDIES

ALL WORK MUST BE CARRIED OUT BY PROFESSIONALLY SKILLED PERSONNEL. BEFORE CARRYING OUT ANY MAINTENANCE JOBS IT IS OBLIGATORY TO STOP THE MACHINE AND DISCONNECT IT FROM THE POWER MAINS.
N.B. OPERATIONS MARKED  MUST BE CARRIED OUT BY PROFESSIONALLY SKILLED PERSONNEL APPROVED THE MANUFACTURERCOOL15-100-Built -In-Dryers-
\(14\)

THIS PART “B” OF THE INSTRUCTIONS MANUAL IS RESERVED FOR PROFESSIONALLY SKILLED PERSONNEL APPROVED THE MANUFACTURER.

STARTING UP

BEFORE CARRYING OUT ANYOPERATION ON THE MACHINE, ENSURE THAT THE ELECTRIC POWER SUPPLY HAS BEEN DISCONNECTED

PRELIMINARY CONTROLS
Before starting the dryer, check:

  • The correct connection to the compressed air piping: remember to remove eventual caps on the drier inlet and outlet.
  • The correct connection to the condensate drainage system.
  • That the power supply is right.

STARTING AND STOP
Start the system before the air compressor starts running and stop it after the air compressor has been stopped. The compressed air piping will be free of condensate only by doing so. The drier must be kept running during all the time the air compressor is running. WARNING: if the drier is switched off, before starting it again, wait at least 5 minutes in order to allow the pressure balancing.
BEFORE CARRYING OUT ANY MAINTENANCE JOBS IT IS OBLIGATORY TO STOP THE MACHINE AND DISCONNECT IT FROM THE POWER MAINS AND FROM THE COMPRESSED AIR DISTRIBUTION NETWORK.

PRESSURE DISCHARGE PROCEDURE (Fig. 10)

Proceed as follows:

  • Close the taps Ref. 1 Fig. 10
  • Release the pressure in the dryer by pressing the condensate drain “TEST” pushbutton locate on the steam trap Ref. 2 Fig. 10
  • Switch off the machine by pressing the STOP button Ref. 3 Fig. 10
  • Turn on the supply automatic differential switch Ref. 4 Fig. 10

CALIBRATIONS

BYPASS VALVE FOR HOT GAS
N.B.These valves have already been calibrated and they do not require any adjistment. A dew point different from the rated one generally
depends on causes which are not attributable to their operation.

  1. Ref. 1) Closing cap
  2. Ref. 2) Adiusting screw

WORKING PRESSURES AND TEMPERATURES OF R134A

| SUCTION SIDE OF REFRIGERATION COMPRESSOR
---|---
| Evaporat. Temperat.

°C (°F)

| Evaporating Pressure bar (psi)
RATED VALUES

(Temperat. 20°C – 68°F)

| **** 1 ÷ 2

(33,8 ÷ 35,6)

| **R134A**

**** 2,1 ÷ 2,3

(30,4 ÷ 33,3)

Read User Manual Online (PDF format)