kryo PLUNGE Coldest Portable Cold Tub User Manual

July 5, 2024
kryo

kryo PLUNGE Coldest Portable Cold Tub

kryo PLUNGE Coldest Portable Cold Tub

DISCLAIMER

  1. Consultation with a Medical Professional:
    Before engaging in cold plunging activities using Krýo Health & Wellness products, consult with a qualified medical professional to assess your individual health condition. Cold plunging effects vary, and your health is our utmost concern.

  2. Awareness of Risks:
    Cold plunging involves exposure to cold temperatures with potential risks, especially for individuals with cardiovascular or respiratory conditions. Be aware of the potential dangers associated with cold plunging.

  3. Acceptance of Responsibility:
    By purchasing and using Krýo Health & Wellness products, you acknowledge and understand the risks of cold plunging.
    You accept full responsibility for potential health risks and complications.

  4. Disclaimer of Liability:
    Krýo Health & Wellness and its affiliates are not liable for any health risks, injuries, or adverse effects resulting from product use. Your use of our products is at your own risk.

  5. Waiver of Claims:
    You waive any claims against Krýo Health & Wellness, its owners, employees, and affiliates arising from the use of our products.

  6. Agreement to Terms:
    By purchasing from Krýo Health & Wellness, you confirm your understanding and agreement to these terms, constituting
    a binding agreement.

  7. Contact Information:
    For questions or concerns, contact our customer support at support@thekryo.com.

WARNINGS

BEFORE ENGAGING WITH YOUR KRÝO HEALTH & WELLNESS TUB, IT IS IMPERATIVE THAT YOU SEEK EXPLICIT APPROVAL FROM A MEDICAL PROFESSIONAL to ensure you are physically fit for its use. Understand the precise risks, the gravity of these risks, and potential consequences associated with cold water usage. Just as in any water receptacle, there is an inherent risk of drowning, which can be fatal. It is your responsibility to to ensure that minors are under constant, rigorous supervision in The Krýo Tub, guaranteeing their continuous safety above water. It is also your responsibility to ensure that anyone who enters can stay above water. Do not, under any circumstances, utilize The Krýo Tub if impaired by any substance that may compromise your ability to remain fully awake, conscious, and operate with a clear mind. With cold water, there is the risk of hypothermia and anyone using the tub should exercise extreme caution and sensible judgment to exit The Krýo Tub before the onset of any such complications. Extreme caution should be used because as your body becomes colder, movements and circulation in your body may slow down. Exercise the utmost caution to exit The Krýo Tub well before any potential complications may arise due to cold water usage. The Krýo Tub is designed exclusively for recreational cold plunge purposes only and must not be repurposed for any other use. To minimize risks, maintain constant awareness of your physical condition while using The Krýo Tub and err on the side of caution. It is underscored that, by using The Krýo Tub, you unequivocally acknowledge and accept the sole responsibility for its hygiene, sanitation, and adherence to its intended use as a recreational cold plunge. This explicit understanding is critical to ensure a secure and enjoyable experience with The Krýo Health & Wellness Tub.

DROWNING

  • To reduce the risk of injury, do not permit children to use this product unless closely supervised at all times.
  • Extreme caution must be exercised to prevent unauthorized access by children.
  • Tub Cover is not a Safety Cover.

ELECTRICAL

This product is provided with a ground-fault circuit-interrupter integrated. The GFCI must be tested before each use. To perform the test, first ensure the blue Power Switch on the back of the Chiller is up in the “on” position and then press the orange “T” Test Button above the Power Switch. The Power Switch should flip to the down “off” position.
Now flip up the Power Switch to the “on” position. If this test does not cause the Power Switch to turn off, DO NOT proceed, and contact support for assistance. DO NOT USE IF THIS TEST FAILS.

  • Do not handle electrical outlet with wet hands.
  • Do not permit any electric appliance within 5 feet of this product.
  • Only use this product with 120v/60hz electrical circuit; outlet must be grounded appropriately.
  • Never submerge machine or expose to direct water spray.

HEALTH

  • Elderly persons, pregnant women, infants, and those with health conditions requiring medical care – especially cardiovascular and neurological – should consult with a physician before using this product.
  • Cold Water Immersion while under the influence of alcohol, narcotics, drugs or medicines may lead to serious injury and is not recommended.
  • Do not use alone.
  • Long exposure may result in hyper or hypothermia, nausea, dizziness, or fainting.
  • Do not exceed 5 minutes in cold; excessive exposure may be harmful to health.
  • Always enter and exit the tub slowly and cautiously. Wet surfaces are slippery

ADVISORY

  • Pool owners may need to comply with local or provincial/state laws relating to childproof fencing, safety barriers, lighting, and other safety requirements. Customers should contact their local building code enforcement office for further details.
  • Keep hair, fingers, towels, and other items away from the fan.
  • Only professional technicians may work on the system.

CONTROL PANEL

  • UP BUTTON
  • DOWN BUTTON
  • SET BUTTON
  • ON/OFF BUTTON
    Control Panel

POWERON/OFF

Hold the ON/OFF Button (1) for 2 seconds to turn the chiller On or Off.

TEMPERATURESET

Hold the Set Button (2) until “SET:” is flashing on the screen. Then press the UP (4) or DOWN (3) Button to set target temperature (9).

CELSIUSOR FAHRENHEIT

Hold the DOWN (3) Button for 10 seconds to switch from Celsius to Fahrenheit or visa versa.

WIFIACTIVATION

Hold the SET Button (2) for 5 seconds to engage Wifi setup mode. Wifi Icon should start blinking (6). If it is solid that means it is connected.

CHILDLOCK

Hold the UP (4) and DOWN (3) button together for 5 seconds to lock or unlock the control panel (7).

OZONESANITIZATION

(8) When this icon is showing that means that ozone sanitization is turned on. DO NOT turn the chiller off when it is blinking or damage will occur.
Blinking indicates that ozone is being generated.

TUB TEMPERATURE

(10) This number shows the temperature coming from the tub.

WATER FLOWINDICATOR

(11) This number shows the water flow of the chiller in litres per minute. If this number ever drops below 13.0L you must replace the filter with a new one.

PARTSREFERENCES

Parts references

PROTECTIVE CAPS

The protective caps that thread on the chiller Inlet and Outlet ports.
Keep these for when you transport your chiller.

WATERHOSES

The flexible hoses are used to flow water from The Krýo Tub to the Chiller. The fittings on the end of each hose connect the Water Hoses to the Chiller Inlet/Outlet and Tub Valve Fittings (Inlet/Outlet).

CHILLER INLET (RED)

The connection on the chiller, which incoming water enters through. This is marked with a red ring.

CHILLEROUTLET (GREEN)

The connection on the chiller, which outgoing water leaves through. This is marked with a green ring.

EXTERNALWATERSTRAINER

The assembly of parts that is used to prevent any debris from entering the chiller. It connects to the Chiller Inlet (red).

20MICRONWATER FILTER

The water filter is used to filter debris from the water running through the chiller. This is placed inside the Water Filter Housing.

Parts references

TUB COVER

The insulated protective cover that locks to your Krýo tub to keep debris out and help maintain the internal temperature.

DOUBLEACTIONAIR PUMP

The air pump used to inflate and deflate the Krýo Tub and Tub Cover.

TUB INLET (GREEN)

The connection on the Krýo tub, which incoming water enters through.
This is marked with a green ring.

TUBOUTLET (RED)

The connection on the Krýo tub, which outgoing water leaves through.
This is marked with a red ring.

INFLATIONVALVES

The ports used to inflate the Krýo Tub and Cover with the Double Action Air Pump. Includes the Inflation Valve Cap, and Inflation Valve Pin.

VALVE FITTINGS

The connection elbow/valve that connects the Tub Fittings to the Chiller Hoses running from the chiller.

O-RINGS

Ensuring O-Rings are in place is always crucial to maintain watertight seals and prevent any leakage. Always check for O-Rings inside both ends of the Water Hose Connections, at the base of the External Water Strainer connection (Chiller Inlet), and inside the upper part of the Water Filter Housing Cap.

LET’SGETSTARTED

  1. Choose a flat, clean, and smooth surface for your Krýo Tub/Chiller setup, ensuring accessibility to both a water source and a 120v power source. If outdoors, opt for a sheltered area for product longevity.
    Avoid placing the chiller in a small enclosed space and keep the fan at least 1ft away from any wall to prevent any hot air recirculation. Allow the chiller to rest for 4 hours before initial use to prevent potential chiller failure
    Let’sgetstarted

  2. Before inflating the Krýo tub, connect the Valve Fittings to the Tub’s “Water Outlet” (red) and “Water Inlet” (green) fittings.
    Turn them clockwise until hand tight, avoiding the use of tools or damage may occur. Align the Valve Fittings according to the indicated orientation.
    Let’sgetstarted

  3. Begin inflation preparation by unscrewing the cap counterclockwise to expose the Inflation Valve. Ensure the Inflation Valve Pin is in the depressed (out) position; failing to do so will result in air release upon detaching the hose.
    Let’sgetstarted

  4. Using the Double Action Air Pump, connect the hose to the “Inflate” side.
    Attach the Inflation Hose to the Tub’s Inflation Valve with a quarter turn clockwise. Inflate until the gauge reaches 10 PSI. Avoid over inflation to prevent damage. Secure the Inflation Valve cap with a clockwise turn.
    Let’sgetstarted

  5. Now that the tub is inflated, it’s time to prepare it for use by washing the inside. To eliminate any residual ‘new tub smell,’ use a small amount of warm water and dish soap. Take a microfiber cloth and gently scrub the interior walls and tub base. This step ensures a clean and fresh start for your cold plunge experience.Let’sgetstarted
    After cleaning the tub, make sure to fully rinse out all the soap. This is crucial to avoid having soapy water when you fill the tub. Thoroughly rinse the interior walls and base until no soap residue remains. This step is best to be done outside or near a drain so you can tip the tub on its side while rinsing.

  6. Take off the red “Inlet” fitting’s Protective Cap on the chiller by turning counterclockwise. Check that the O-Ring is still intact at the base of the Inlet. Insert the External Water Strainer onto the red “Inlet” by rotating clockwise. Ensure to only hand-tighten securely, avoiding excessive force.
    Let’sgetstarted

  7. Take off the green “outlet” fitting’s Protective Cap on the chiller by turning counterclockwise, then ensure there’s a Hose O-Ring in each of the four hose connection fittings. If absent, use a spare o-ring from the parts bag. Connect onewater hose end to the Chiller Outlet (green). To secure, screw on the Hose Connection Fitting and turn clockwise; the threading should be smooth. If resistance occurs, attempt reattachment. Hand tighten solely, as excessive force may lead to leaks or damage.
    Let’sgetstarted

  8. Extend the process by attaching one of the hose connection fittings of the other water hose to the rear of the External Water Strainer, located on the Chiller Inlet (red).
    Employing the prior approach, only handtightening for a secure connection.

  9. Unscrew the Lower Water Filter Housing, place a 20 micron water filter inside and fill with water. Confirm the Filter Housing O-Ring is properly positioned inside the Upper Water Filter Housing. Secure the Lower Water Filter Housing by turning clockwise (right when facing the back of the Chiller) until hand-tight. Refrain from using the filter wrench for tightening; it is designed for loosening purposes only.
    Let’sgetstarted

  10. Link the Chiller to the Krýo Tub by connecting the green “Water In” Tub fitting to the green “Outlet” on the Chiller with the water hose. Similarly, connect the red “Water Out” Tub fitting to the red “Inlet” on the Chiller with the other water hose. Secure the connection by threading on the Hose Connection Fittings and rotating clockwise. Ensure smooth tightening; if resistance is felt, reattach the hose. Han tighten only to prevent potential leaks or damage.
    Let’sgetstarted

  11. Now, using a water hose fill the Krýo Tub with water up to the “MAX” level line.
    Be cautious not to overfill, as it may cause water overflow for some users. Adjust the water level to your preference.
    Let’sgetstarted

  12. After filling the tub, ensure that the Tub Valve Fittings are positioned in the open (parallel) state. DO NOT forget this step before powering on the chiller or damage may occur.

  13. Connect the Chiller to a standard 120v grounded power outlet with a minimum 15-amp circuit and check the GFCI functionality. First, make sure the Power Switch on the back of the Chiller is in the ‘on’ position. Press the orange ‘T’ Test Button located above the Power Switch.
    The Power Switch should flip to the ‘off’ position. Next, flip the Power Switch back to the ‘on’ position. If the Power Switch does not turn off during this test, stop and contact support for assistance.