Kipco Digital Multimeter User Manual
- June 7, 2024
- Kipco
Table of Contents
- Statement
- Introduction
- Safety instructions
- Safety standard operation
- Electrical symbol
- Meter indication
- Replacing the battery and fuze
- Doide
- Continuity Buzzer
- Capacitance
- Meter maintenance
- General maintenance
- Measuring guide
- Capacitance measurement
- AC current and DC Current measurement
- Overall index
- Precision index
- DC voltage
- AC voltage
- DC current
- AC current
- Resistance
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
**Kipco Digital Multimeter User Manual
**
Statement
Any content of this manual may not be reproduced in any form ( including
stored, retrieved or translated into other languages without the permission
and written consent in accordance with international copyright laws. This
manual is subject to change in future versions without further notice .
(Caution]
The “Caution” sign indicates conditions and actions that could cause damage to
the meter or equipment. It requires that the operation must be careful.
Misoperation or improper procedure may cause damage to the meter or equipment.
Do not proceed with any of the actions indicated by the caution signs If these
conditions are not met or are not fully understood.
[Warning]
The “Warning” sign indicates conditions and actions that are dangerous to the
user. It requires that the operation must be paid attention. Misoperation or
improper procedure may cause damage to the meter or equipment. Do not proceed
with any of the actions indicated by the caution signs If these conditions are
not met or are not fully understood. Please read the instructions carefully
and pay attention to the safety warnings before using the meter.
Introduction
This watch is a digital multimeter that can be carried around. It has stable
performance, high precision, low power consumption, novel structure, safety
and reliability, and is an ideal measuring meter for users.
The meter can measure DC voltage, AC voltage, DC current, AC current,
resistance, diode, continuity and capacitance with non-contact voltage
detection function to remind users operating safety, making the operation
safer for users. This manual contains relevant safety information and
warnings, etc. Please read the contents carefully before using the meter and
strictly abide by all warnings and precautions.
Safety instructions
This digital Multimeter is designed and manufactured in accordance with the the safety requirements of IEC-61010. It meets the requirements of double insulation, 600V CAT III and pollution level 2 of IEC61010. Before using the Multimeter, please read the users manual carefully, otherwise the protection function may be reduced or invalid.
Safety standard operation
Warning
To avoid possible electric shock or personal jury, please strictly abide by
the following specifications:
- Please read “Safety Information” before using the meter. And use the meter in accordance with the regulations. otherwise the protection function may be reduced or invalid.
- Check the case before using the meter. Check for cracks or missing plastic parts. Please carefully check the insulation near the input terminals
- Do not use the meter if it is not working properly or is damaged.
- It is forbidden to touch the charged body with voltage exceeding 30V hare RMS AC, 42V AC peak or 60V DC.
- The meter should be used according to the specified measurement category, voltage or current rating.
- Replace the the battery as soon as the insufficient battery indicator appears. Insufficient battery power may cause incorrect meter readings
- Please comply with local and national safety regulations, wear personal protective equipment (qualified rubber gloves, masks, and flame retardant clothing, etc.) to protect yourself from electric shock and arcing when live conductors are exposed
- The voltage applied between the input terminals or between each terminal and the grounding point shall not exceed the rated value specified by the Meter.
- Measure a sapoint voltage to determine if the meter is operating properly.
- Use the correct input terminal, function position and range position when measuring.
- Do not use the Meter around explosive gas, vapor or humid environment
- Do not use a damaged probe. Check if there are damage, exposed metal or signs of wear of the insulation layer of the probe. Check the continuity of the probe.
- W hen measuring, connect the neutral or ground wire first, then connect the live wire; when disconnecting, please cut off the live wire first, then disconnect the neutral wire and ground wire.
- W hen using probes, keep your fingers behind the finger guards on the probes.
- Disconnect the probe and the objects to be measured before opening the back cover of the Meter.
- Do not use the meter in an environment that exceeds the measurement category (CAT) rating of the individual component with the lowest rating in the meter,probe, or accessories.
Electrical symbol
| Warning of high voltage
---|---
| AC (Alternating current)
| DC (Direct current)
| AC or DC
| ARNIG, important safety signs
| Earth ground
| Fuse
| Equipment is protected by double insulted or reinforced insulation
| Insufficient power of the battery
| Conforms to European Union directive
| Do not discard such electrical/electronic products in household waste
| Category II measurements are suitable for testing and measuring circuits
| that are directly connected to the power points (sockets and similar points)
of a low voltage power supply unit
| Category IV measurements are suitable for testing and measuring circuits
connected to the low voltage power supply unit of a building
Meter indication
- illuminator
- non-contact voltage induction zone
- non contact voltage indicator
- display
- pushbutton
- red probe
- black probe
- function switch
•: switch of backlight and illumination and data hold button Click to open the data hold, then click to cancel the data hold Press and hold for more than 2 seconds, turn on the backlight and illumination turn off Clean the case with a damp cloth and a small amount of detergent. Do not use abrasives or chemical solvents. Input terminal that are dirty or damp may affect readings. .
Replacing the battery and fuze
ln order to avoid electric shock or personal injury caused by incorrect
reading, the battery should be replaced as soon as possible when the low
voltage symbol ” ” display appears. To ensure safety operation and maintain
the equipment, please remove the battery to avoid the damage to the equipment
of the leaked battery when not in use for a long time.
In order to avoid electric shock or personal injury, shut down and check that
the probe has been disconnected from the measuring circuit before open the
battery cover and replace the battery. Replace the battery as follows:
- Turn off the power of the Meter.
- Disconnected the probes from the the measuring circuit.
- Loosen the screws that secure the battery cover with a wire cutter and remove the battery cover
- Take away the old battery and replace with a new one.
- Attach the battery cover and tighten the screws.
200Ω | o.1 Ω | 41.0% + 3) |
---|---|---|
2KΩ | 0 001kΩ | |
20KΩ | 10.01kΩ | |
200KΩ | 0.1 kΩ | |
2MΩ | 0.00IMΩ | |
20 MΩ | 0.01MΩ | *0.2% + 15) |
Overload protection:600V DC/AC RMS
Doide
Function | Range | Resolution | Testing conditions |
---|---|---|---|
Diode testing it | IV | 0.001 V | Forward DC current: about I mA: |
open-circuit voltage: about 2.8V
Display shows the approximate value of
diodc forward voltage drop
Overload protection:600V DC/AC RMS
Continuity Buzzer
Function | Description | Testing conditions |
---|---|---|
The resistance of the circuit under test is |
not more than about 50, when the buzzer
emits a continuous sound.| Forward DC current: about
I mA: open-circuit voltage:
about /W
Overload protection:600V DC/AC RMS
Capacitance
Range | Resolution | Accuracy |
---|---|---|
20n1: | 0.01 nI, | *00% + 40) |
600nF | O.InF | 3(2.5% + 20 ) |
2uF | le | |
20uF | I OnF | |
200uF | 100nF | |
2000uF | I uF | gs%+ to) |
Overload protection:600V DC/AC RMS
Meter maintenance
This section provides basic maintenance information, including instructions
for replacing the fuse and replacing the battery. To avoid electric shock or
personal injury. repairs should be performed by qualified personnel with
relevant information of calibration. performance test and maintenance.
Warning : In order to avoid possible electric shock, fire or personnel
injury, do not perform any measurement with the Meter when the outer casing is
opened. Remove the input signal before clean the meter.
General maintenance
automatically after about 15 seconds or press again and keep it manually for
more than 2 seconds
‘: Non-contact voltage detection, AC current and DC current measurement
selection keys:
- Power switch and capacitance measurement selection button, long press to turn on or press and keep more than 2 seconds to shut down. short press to switch to capacitance measurement function, the meter will automatically cut off if there is no operation after about 15 minutes, and the buzzer will alert I minute before shutdown.
Measuring guide
- AC and DC voltage/resistance /diode/continuity testing
- AC DC voltage / resistance / diode measurement connectivity test
- Press the power button to turn on the meter and put the function selector switch at the position of
- Connect the test leads in parallel to the circuit, power supply, resistor or diode to be tested. The meter automatically determines the DC voltage, AC voltage, resistance, and diode.
- When the resistance of the circuit under test is not more than about 50f2, the buzzer emits a continuous sound.
- Read the measurement results from the display. When measuring DC voltage, the display also shows the voltage polarity of the test point of red probe.
- Press the power switch key and hold it for 2 seconds to turn off the meter power when the measurement is done.
Warning
- Do not input a voltage higher than 600V. It is possible to display a higher voltage value, but there may be damage to the meter.
- W hen measuring high voltage, be extremely careful of electric shock.
- After completing all measurement and measurement operations, disconnect the probe from the circuit under test.
Capacitance measurement
- Press the power button to turn on the meter and put the function selector switch at the position of
- Short press the key to switch to the capacitance measurement function.
- Connect the two ends of the probes of the capacitors and read the measurement results from the display. Note: When measuring high capacitance, it takes time to stabilize the readings
Warning :
- To avoid damage to the Meter or to the equipment under test, disconnected circuit power and discharged all high-voltage capacitors before measuring capacitance. To determine that the capacitor has been discharged adopting by the DC voltage file.
AC current and DC Current measurement
- Pull the function selector switch to the
- Turn off the power to the circuit under test and discharge all high voltage capacitors on the circuit under test.
- Disconnect the circuit to be tested and connect the meter in series to the circuit to be measured. Press the button to switch the DC or AC current measurement function.
- Connect the power to the circuit and read the measurement from the display. If the display only shows “”OL”, this means that the input exceeds the meter’s measurement range. When measuring DC current, the display also shows the voltage polarity of the test point of the red probe.
- Turn off the power to the circuit under test, remove the meter’s probe and restore the circuit to its original state.
Warning :
- In order to prevent possible electric shock, fire or personal injury, when measuring current, disconnect the power of the circuit under test firstly, and fully discharge all high-voltage capacitors, and then connect the meter to the circuit.
- D o not input 200mA higher than the maximum measured current value of the meter. Otherwise, the self-recovery fuse inside the meter may invalid and “cut off” the circuit.
- After completing all measurement operations, disconnect the test leads from the circuit under test 7.4 Non-contact voltage detection
- Press the power switch to turn on the power of the meter.
- Press the “NCV” button and hold it, then make the non-contact voltage induction zone of the meter close to the (in less than 5mm) line of the AC voltage.
- The meter non-contact voltage indicator will light up and there will be a buzzer tone indicating that there is an AC voltage on the line.
Overall index
Operating environmental: 600 V CATMV and 1000VCAT.III Pollution level: 2 The altitude is <2000m. Temperature and humidity of the working environment: 0 — 40C (<80% RH, when the temperature <10 ° C, it is not considered ) Temperature and humidity of storage environment: -10 — 60CC (<70% RH, remove the battery) Maximum voltage can be allowed between the measuring terminal and the earth ground: 600 V DC or AC RMS Protection of self-recovery fuse 200mA/265V Sampling rate: about 3 times /sec
Display: LCD display in 31/2. Overrange indication: The LCD will display “01:. Indication of low voltage of battery: When the battery voltage is lower than the normal working voltage, “ “‘ will display Indication of input polarity : The “-” sign is automatically displayed. Power: 2x I.5V AAA battery Dimensions: 128 x 61 x25
Precision index
Accuracy is suitable after one year from the date of calibration. Reference conditions: 18 ° C to 28 ° of the ambient temperature, relative humidity not more than 80%
DC voltage
Range | Resolution | Accuracy |
---|---|---|
2V | 0.00IV | -1(0.5% + 3 ) |
20V | 0.0IV | |
200V | 0.IV | |
600V | I V | ±(0.8% + 3 ) |
Input impedance: 10MΩ Maximum input voltage 600Vdc or RMS
AC voltage
Range | Resolution | Accuracy |
---|---|---|
2V | 0.001V | ±(0.8%+ 3) |
20V | 0.0IV | |
200V | 0.1V | |
600V | 1 V | ±(1.0%+3) |
Input impedance: 10MΩ
Maximum input voltage 600Vdc or RMS Frequency response: 40HZ;
DC current
Range Resolution Accuracy
20mA 0.0ImA ±(1.8% + 3)
200mA 0.1mA|
Input protection: self-recovery fuse of 200mA/265V
AC current
Range | Resolution | Accuracy |
---|---|---|
20mA | o.o1mA | =(2.0%+3) |
200mA | o.1mA |
Input protection: self-recovery fuse of 200mA/265V
Resistance
Range | Resolution | Accuracy |
---|
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>