ideal lux Eclissi Indoor LED Wall Light Small Big Instruction Manual
- July 4, 2024
- ideal lux
Table of Contents
ideal lux Eclissi Indoor LED Wall Light Small Big
Product Specifications:
- Model: Eclissi AP Small
- LED: 11W / 220~240V 50/60Hz
- EAN: 8021696259048 ORO
- Manufacturer: IDEAL LUX s.r.l.
- Country of Origin: Italy
Product Usage Instructions
Assembly Instructions:
Follow the assembly instructions by reading the numerical progression
provided in the manual.
Installation:
The lighting fitting should be installed by a qualified electrician.
Light Source Information:
- Model: ECLISSI SMALL
- Efficiency Class: F
- Light Source: Module Round, Module Strip
- Light Source Current/Voltage: 300 mA 4 W / 18 V DC 12 V DC
Additional Information:
- This product contains a replaceable light source.
- The LED light source is replaceable by an end-user.
- Control gear can be replaced by the end-user.
Frequently Asked Questions (FAQ):
-
Q: Can I replace the light source myself?
A: Yes, the light source is replaceable by the end-user. Follow the instructions provided in the manual for replacement. -
Q: Is it safe to install this product without professional help?
A: It is recommended to have a qualified electrician install the lighting fitting for safety reasons.
LED
LED 11W / 220~240V 50/60Hz – 8021696259048 ORO
FOLLOW THE ASSEMBLY INSTRUCTIONS BY READING THE NUMERICAL PROGRESSION.
THE LIGHTING FITTING SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN.
THE SAFETY AND RELIABILITY ARE GUARANTEED ONLY WHEN INSTALLATION INSTRUCTIONS ARE PROPERLY FOLLOWED. PLEASE KEEP THIS INSTRUCTION SHEET FOR FUTURE REFERENCE.
This product is provided with a light source with efficiency energy class
of:
8021696259048
Light Source
Model
ECLISSI SMALL
MODULE ROUND, ECLISSI SMALL MODULE STRIP
Energy
Effificiency Class
F
Light Source (mA)
300 mA
4 W
Light Source (V)
18 V DC
12 V DC
LEGENDA ICONE
Replaceable light source by an end-user.
Replaceable LED light source by an end-user.
Replaceable light source by authorized personnel only.
Non-replaceable light source. Upon end
of life of the light source, the whole product will be replaced.
Replaceable control gear by an end-
user.
Replaceable light source by authorized personnel only.
Upon end of life of the control gear, the whole product will be replaced.
SAFETY INSTRUCTIONS
- This fitting is produced and tested in accordance with the strictest European safety standards (EN 60.598-1).
- This fitting cannot be disposed of as household waste. For disposal information ask the local authorities about how to collect it.
- As indicated by specific regulations, the lighting fitting should be installed by a qualified electrician.
- If the external wire is damaged it has to be replaced exclusively by the manufacturer, distributor or by a qualified electrician.
- Always isolate power before commencing installation, maintenance or repair.
- The luminaire contains certain parts which can be very hot.
- Each material requires specific mounting accessories. Use screws and wall plugs suitable for the material to which they are fastened. Those included may be unsuitable.
- Always tighten the screws firmly to avoid contact problems.
- This fitting should only be installed indoors.
- Luminaires not suitable for recessed on normally flammable surfaces.
- Luminaire not suitable for direct mounting on normal flammable surfaces.
- This fitting is only suitable for fixing to the ceiling.
- This fitting is only suitable for fixing to the wall.
- The weight of the lamp has to be supported by the chain. Adjust the length of the electric wire so that it is longer than the chain.
- Only use lamps which do not exceed the maximum specified wattage.
- Always observe the minimum distance between the lamp and the surface being lit, as shown in the icon. The lamp can cause a fire if the minimum distance is not observed.
- Auto-protected bulb. Only use bulbs marked with this symbol. Halogen bulbs get very hot. Wait until they cool down before replacing.
- Cracked or broken safety glass has to be replaced immediately. Use only manufcturer approved parts complying with regulations.
- Light source with not-substitutable light emitting diode (LED). Do not disassemble the product since the diodes can damage the eyes. Do not immerse in water.
- Wipe with a damp cloth. Do not use solvents or strong detergents.
- This fitting is equipped with a fuse. If the lamp is out of order, replace the internal fuse.
- Class I Electrical safety guaranteed by the main insulation and an additional protective conductor (earthing) connected with the metal frame of the lamp. Earthing is obligatory.
- Class II Electrical safety guaranteed by the main insulation and a double or reinforced insulation. Earthing not necessary.
- Class III Electrical safety guaranteed by very low power supply (less than 50 Volt). Earthing excluded.
- Not protected.
- Protected against solid objects greater than 50 mm.
- Protected against solid objects greater than 12 mm.
- Protected against solid objects greater than 2,5 mm.
- Protected against solid objects greater than 1mm.
- Dust protected.
- Totally protected against dust infiltration.
- Not protected.
- Protected against vertically falling water drops.
- Protected against water drops falling with a maximum angle of 15° to the vertical axis.
- Protected against rain.
- Protected against splashing water.
- Protected against water jets.
- Protected against strong water jets.
- Protected against temporary immersion.
- Protected against prolonged immersion.
- Luminaire not suitable for covering with thermally insulating material.
- Caution, risk of electric shock.
- Do not stare at the operating light source.
Eclissi AP Big
LED
LED 30W / 220~240V 50/60Hz – 8021696259062 ORO
FOLLOW THE ASSEMBLY INSTRUCTIONS BY READING THE NUMERICAL PROGRESSION.
THE LIGHTING FITTING SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN.
THE SAFETY AND RELIABILITY ARE GUARANTEED ONLY WHEN INSTALLATION INSTRUCTIONS ARE PROPERLY FOLLOWED. PLEASE KEEP THIS INSTRUCTION SHEET FOR FUTURE REFERENCE.
This product is provided with a light source with efficiency energy class
of:
8021696259062
Light Source Model
ECLISSI BIG MODULE ROUND, ECLISSI BIG MODULE STRIP
Energy
Effificiency Class
E
Light Source (mA)
250 mA
14,28 W
Light Source (V)
30 V DC
12 V DC
LEGENDA ICONE
Replaceable light source by an end-user.
Replaceable LED light source by an end-user.
Replaceable light source by authorized personnel only.
Non-replaceable light source. Upon end of life of the light source, the whole
product will be replaced.
Replaceable control gear by an end-
user.
Replaceable light source by authorized
personnel only.
Upon end of life of the control gear,
the whole product will be replaced.
SAFETY INSTRUCTIONS
-
This fitting is produced and tested in accordance with the strictest European safety standards EN 60.598-1).
-
This fitting cannot be disposed of as household waste. For disposal information ask the local authorities about how to collect it.
-
As indicated by specific regulations, the lighting fitting should be installed by a qualified electrician.
-
If the external wire is damaged it has to be replaced exclusively by the manufacturer, distributor or by a qualified electrician.
-
Always isolate power before commencing installation, maintenance or repair.
-
The luminaire contains certain parts which can be very hot.
-
Each material requires specific mounting accessories. Use screws and wall plugs suitable for the material to which they are fastened. Those included may be unsuitable.
-
Always tighten the screws firmly to avoid contact problems.
-
This fitting should only be installed indoors.
-
Luminaires not suitable for recessed on normally flammable surfaces.
-
Luminaire not suitable for direct mounting on normal flammable surfaces.
-
This fitting is only suitable for fixing to the ceiling.
-
This fitting is only suitable for fixing to the wall.
-
The weight of the lamp has to be supported by the chain. Adjust the length of the electric wire so that it is longer than the chain.
-
Only use lamps which do not exceed the maximum specified wattage.
-
Always observe the minimum distance between the lamp and the surface being lit, as shown in the icon. The lamp can cause a fire if the minimum distance is not observed.
-
Auto-protected bulb. Only use bulbs marked with this symbol. Halogen bulbs get very hot. Wait until they cool down before replacing.
-
Cracked or broken safety glass has to be replaced immediately. Use only manufacturer approved parts complying with regulations.
-
Light source with not-substitutable light emitting diode (LED). Do not disassemble the product since the diodes can damage the eyes. Do not immerse in water. Wipe with a damp cloth. Do not use solvents or strong detergents.
-
This fitting is equipped with a fuse. If the lamp is out of order, replace the internal fuse.
-
Class I Electrical safety guaranteed by the main insulation and an additional protective conductor (earthing) connected with the metal frame of the lamp. Earthing is obligatory.
-
Class II Electrical safety guaranteed by the main insulation and a double or reinforced insulation.
Earthing not necessary. -
Class III Electrical safety guaranteed by very low power supply (less than 50 Volt). Earthing excluded.
-
Not protected.
-
Protected against solid objects greater than 50 mm.
-
Protected against solid objects greater than 12 mm.
-
Protected against solid objects greater than 2,5 mm.
-
Protected against solid objects greater than 1mm.
-
Dust protected.
-
Totally protected against dust infiltration.
-
Not protected.
-
Protected against vertically falling water drops.
-
Protected against water drops falling with a maximum angle of 15° to the vertical axis.
-
Protected against rain.
-
Protected against splashing water.
-
Protected against water jets.
-
Protected against strong water jets.
-
Protected against temporary immersion.
-
Protected against prolonged immersion.
-
Luminaire not suitable for covering with thermally insulating material.
-
Caution, risk of electric shock.
-
Do not stare at the operating light source.
IDEAL LUX s.r.l.
Via Taglio Destro 32
30035 Mirano (VE) Italy
www.ideal-lux.com
IDEAL LUX Warehouse
Via delle Industrie, 8/D
30036 Santa Maria di Sala (Venezia)
8.00 – 12.00 / 13.30 – 17.00
Read User Manual Online (PDF format)