BLUETTI AC240P Portable Power Station
AC240P
Portable Power Station
User Manual v,.o
Please read this manual carefully before use and keep it for future reference.
Warning
- Charge the unit before first use.
- Do not use solar panels with open circuit voltage higher than 60VDC. Solar input voltage range for the unit is 72V-60VDC.
- Charge the unit immediately when the Soc drops below 5%. If the Soc drops to 0, power off the unit and charge it for at least 30 minutes before restarting.
- The unit is for off-grid use only. Do not connect its AC output to the grid.
- If not used for more than 3 months, charge the unit to 40%-60% Soc and store it with the power off. For optimum battery life, discharge and charge the unit every 3 months.
Thank You!
Thank you for making BLUETTI a part of your family.
From the very beginning, BLUETTI has tried to stay true to a sustainable
future through green energy storage solutions while delivering an exceptional
eco-friendly experience for our homes and our world.
That’s why BLUETTI makes its presence in 700+ countries and is trusted by
millions of customers across the globe.
Copyright© Shenzhen PowerOak Newener Co., Ltd. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by
any means without the prior written consent of Shenzhen PowerOak Newener Co.,
Ltd.
Notice
BLUETTl’s products, services, and features are subject to the agreed-upon
terms and conditions during purchase. Please note that some products,
services, or features described in this manual may not be available under your
purchase contract. Unless otherwise specified in the contract, BLU ETTI makes
no representations or warranties of any kind, express or implied, with respect
to the contents of this manual.
The contents of this manual are subject to change without notice. Please get
the latest version from: https://www.bluettipower.com/pages/user-guides
If you have any questions or concerns about this manual, please contact
BLUETTI support for further assistance.
Safety Instructions
Read this manual for instructions on the proper use and safety information for the product. The safety instructions provided herein are for illustrative purposes that include but are not limited to those listed in this manual. Actual operation shall comply with all applicable safety standards. If you have any questions, feel free to contact BLUETTI support or your local BLUETTI dealers.
Statement
To ensure a safe operation, it’s crucial to observe and adhere to the
following conditions:
- Always operate or store the product in the conditions specified in this manual.
- Avoid unauthorized disassembly, component replacement, or modification of software codes.
- BLUETTI shall not be liable for damages resulting from the following circumstances:
- Force majeure events such as earthquakes, fires, storms, floods, or mudslides.
- Damage caused by the customer’s own transportation.
- Damage resulting from inadequate storage conditions as specified in the manual.
- Damage caused by customer negligence, improper operation, or intentional actions.
- System or hardware damage caused by third parties or customers, including but not limited to improper handling and installation not in accordance with the instructions in this manual.
- Usage of the product with devices that require a high-performance Uninterruptible Power Supply (UPS), including but not limited to data servers, workstations, medical equipment, and other similar devices.
General Requirements
INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRIC SHOCK, OR INJURYTO PERSONS
IMPORTANT SAFETY INSTRUCTIONS
WARNING
When using this product, basic precautions should always be followed,
including the following:
-
Read all the instructions before using the product.
-
To reduce the risk of injury, close supervision is necessary when the product is used near children.
-
Do not put fingers or hands into the product. And do not insert foreign objects into any ports of the product.
-
Use of an attachment not recommended or sold by the manufacturer may result in a risk of fire, electric shock, or injury to persons.
-
To reduce the risk of damage to the electric plug and cord, pull the plug rather than the cord when disconnecting the product.
-
Do not use a battery pack or appliance that is damaged or modified, as they may exhibit unpredictable behavior resulting in fire, explosion, or personal injury.
-
Do not operate the product with a damaged cord or plug, or a damaged output cable.
-
Do not attempt to replace the i nterna I battery or any other component of the product by anyone other than authorized personnel. There are no end-user serviceable components.
-
Do not disassemble the product, take it to a qualified service person when service or repair is required. Incorrect reassembly may result in a risk of fire or electric shock.
-
To reduce the risk of electric shock, unplug the product from the outlet before attempting any instructed servicing.
-
WARNING – RISK OF EXPLOSIVE GASES. To reduce the risk of battery explosion, follow these instructions and those published by the battery manufacturer and manufacturer of any equipment you intend to use in the vicinity of the battery. Review cautionary markings on these products and engines.
-
PERSONAL PRECAUTIONS
-
Wear complete eye protection and clothing protection. Avoid touching eyes while working near the battery.
Never smoke or allow a spark or flame in the vicinity of the battery or engine. -
Be extra cautious to reduce the risk of dropping a metal tool onto the battery. It might spark or short-circuit the battery or other electrical parts which may cause an explosion.
-
-
When charging the internal battery, work in a well ventilated area and do not restrict ventilation in any way.
-
Under abusive conditions, liquid may be ejected from the battery; avoid contact. If contact accidentally occurs, flush with water. If liquid contacts eyes, additionally seek medical help. Liquid ejected from the battery may cause irritation or burns.
-
Do not expose the product to fire or excessive temperature. Exposure to fire or temperature above 80°C (776°F) may cause an explosion.
-
Have servicing performed by a qualified repair person using only identical replacement parts. This will ensure that safety is maintained.
-
Do not stack anything on top of the product while in storage or while in use. Do not move the product while operating as vibrations and sudden impacts may lead to poor connections to the hardware inside.
-
In case of fire, use only a dry powder fire extinguisher appropriate for the product.
-
WARNING – RISK OF ELECTRIC SHOCK. Never use the product to supply power tools to cut or access live parts or live wirings, or materials that may contain live parts or live wirings inside, such as building walls, etc.
Grounding Instructions
The product is designed for portable use and typically does not require earth
grounding. However, if you connect it to the power grid, it’s important to
ensure proper grounding for safety. If it should malfunction or break down,
grounding provides a path of least resistance for electric current to reduce
the risk of electric shock. This product is equipped with an AC power cord
having an equipment-grounding conductor and a grounding plug. The plug must be
plugged into an outlet that is properly installed and grounded in accordance
with all local codes and ordinances.
WARNING – Improper connection of the equipment-grounding conductor can result
in a risk of electric shock. Check with a qualified electrician if you are in
doubt as to whether the product is properly grounded. Do not modify the plug
provided with the product – if it does not fit the outlet, have a proper
outlet installed by a qualified electrician.
Handling Requirements
During transportation or storage, take care to avoid dropping, violently
impacting, or tilting the product as it may result in internal damage. If
necessary, use mechanical assistance such as carts or adjustable height
workbenches to ensure safe handling.
Storage Instructions
- When the Soc drops to 5%, please charge the product immediately.
- Before storing the product, charge it to 40% to 60% Soc to keep it in optimal condition. In addition, power off the unit and disconnect all electrical connections from it.
- Store the product in a cool and dry place, keeping it away from flammable or combustible materials and gases.
- The product can be safely stored within a temperature range of -20°C to 45°C ( -4° F to ll3° F). However, if the storage duration exceeds one month, it’s recommended to maintain an ideal storage temperature of around 30°C (86° F).
- Fully cycle the product for months to maintain the battery’s health. It’s NOT recommended to store the unit for extended periods of time, as it may affect its performance and overall lifespan.
If the Soc drops to O (during storage or upon startup), take the following actions to safely restart the product:
- Shut down immediately.
- Charge within 48 hours.
- Keep it at an ambient temperature of 5°C to 35°C (47° F to 95° F) for 6 hours before charging. It’s recommended to charge the product via an AC source. If charging via solar energy, ensure that your solar system provides an output of more than 700W.
- The symbol displayed is intended to remind you to read the instructions in the literature accompanying the product before operation and maintenance.
- Connect the product to a socket-outlet that has an earthing connection using the power cord provided.
- The socket-outlet should be installed near the product and easily accessible for safety purposes.
- Never dis pose of a battery by throwing it into f ire or a hot oven, or by mecha n ica I ly crushing or cutting it, as these may cause it to explode.
- Avoid leaving batteries in extremely high-temperature environments, as this can result in an explosion or the leakage of flammable liquid or gas.
- The battery subjected to extremely low air pressure may result in an explosion or the leakage of flammable liquid or gas.
- Attention should be drawn to the environmental aspects of battery disposal.
- Please refer to the information on the exterior bottom enclosure for electrical and safety information before installing or operating the apparatus.
SAVE THESE INSTRUCTIONS
BLUETTI shall not be liable for any equipment damage caused by the violation
of the above instructions.
Packing List
Standard Accessories
Optional Accessories
(Available on the official BLUETTI website:
https://www.bluettipower.com)
Product Introduction
Meet the BLUETTI AC240P Power Station, an exceptional energy solution for
travel enthusiasts who demand the best. With a massive 2,400W output, it can
power everything
from small electronics to large RV appliances. Plus, its IP65-rated water and
dust resistance makes it durable enough to withstand even the harshest weather
conditions. Not only that, but the AC240P also boasts an impressive battery
capacity that ranges
from 7,843Wh to a staggering 70,443Wh with four B270P expansion batteries. And
if you need even more power, you can simply connect another AC240P for
uninterrupted power for days on end.
Managing the AC240P is a breeze thanks to the BLUETTI App, which lets you
control the unit’s various functions and settings with ease. With features
like ECO Mode and UPS Mode, you can optimize your power consumption and
protect your device at all times. Whether you’re camping or on a road trip,
the AC240P provides a reliable and
easy-to-use energy solution for your on-the-go lifestyle.
Danger:
Do not connect the AC output of AC240P to the grid.
Product Overview
- Battery Expansion Port
- USB-C Port
- Cigarette Lighter Port
- USB-A Port
- Power Button
- RV Port
- DC Power Button
- DC Input
- LED Screen
- AC Input
- USB Power Button
- Grounding Pole
- AC Power Button
- Bleed Valve
- NEMA TT-30 Port
- Parallel Port
- AC Output
Power ON / OFF
Attention
Please place the unit on the platform firmly and stably.
- Power ON: Press and hold the Power Button for more than 2 seconds, and the button lights up indicating that the AC240P is now on standby.
- Power OFF: Press and hold the Power Button for 2 seconds to turn off the unit.
- AC ON/ OFF: When the AC240P is on, press the AC Power Button to turn it on/ off.
- USB ON/ OFF: When the AC240P is on, press the USB Power Button to turn it on/ off.
- DC ON/ OFF: When the AC240P is on, press the DC Power Button to turn it on/ off.
LED Screen
The AC240P features an informative LED screen that offers easy access to all the essential information about the unit’s status and performance. When you power on the unit, the LED screen lights up, and when you power off the unit, the screen turns off as well.
-
CD Expansion Battery
-
Grid Connection
-
Overcu rrent Alert
-
Silent Charging
-
DC Outpu
-
Fa u It Alert
-
DC Input
-
AC Output
-
DC Output Power
-
Bluetooth Connection
-
Power Lifting Mode
-
Low Battery Alert
-
WiFi Connection
-
Charge/ Discharge
-
Battery Ca pa city (SoC)
Remaining Time -
Fan Status
-
DC Input Power
-
Charge/ Discharge Status
-
CV Turbo Charging
-
ECO Mode
-
Parallel Connection
-
AC Input Power
-
Charge/ Discharge
-
Low Temperature Alert Progress
-
AC Output Power
-
High Temperature Alert
-
AC Output Voltage
-
Overload Alert
-
AC Output Frequency
-
Charging
AC240P supports five charging methods: AC, solar, car, generator, and Lead- acid battery.
Attention:
- Double-check that all cables are firmly plugged in.
- Avoid getting the plug and socket wet to prevent any potential damage.
AC Charging
Plug the AC240P into a standard wall outlet and start charging. Once it’s
fully charged, the AC240P automatically stops charging to prevent
overcharging. For a fast charge, you can enable Turbo Charging in the BLUETTI
App, which allows for an 80% capacity in just 45 minutes at an ambient
temperature of 25°C (77° F).
Solar Charging
Connect the solar panels (in series or parallel) to AC240P via the solar
charging cable. When receiving a continuous input of 7200W, the AC240P can be
charged up to 80% in about 7.3 hours. However, please be aware that the
charging time may vary based on weather conditions, sunlight intensity, panel
orientation, and other variables.
Note
- Make sure your solar panels meet the following requirements: Voe: llV-60V Current: 27A Max. Power: 7200W Max.
- Non-waterproof solar panels will lose efficiency if they get exposed in the rain for a long time.
Attention:
For solar panels with an open circuit voltage between 60V and 745V, you can
still use them to charge the AC240P. Simply connect the solar panels to the
AC240P via the PV Voltage Regulator, and you can enjoy seamless and hassle-
free solar charging.
Car Charging
Connect AC240P to the vehicle’s 72V cigarette lighter port via the car
charging cable. The AC240P automatically stops charging once it’s fully
charged.
Note: Make sure your vehicle meets the following conditions for charging:
The vehicle is capable of supplying power with a maximum current of SA.
The vehicle’s engine is running during the charging process.
Generator Charging
Connect theAC240Pto a generator via the AC charging cable. TheAC240P also
automatically stops charging when it ‘s fully charged.
Note: Make sure your generator delivers the AC output with charging voltage,
frequency, and Grid Self-adaption Mode voltage that meet AC240P’s
specifications.
If the total power demand of your connected devices exceeds the generator’s
output capacity, please turn on the Grid Self-adaption Mode to ensure a
seamless charging experience.
Lead-acid Battery Charging
In this method, the AC240P is charged by connecting the lead-acid battery and
the AC240P DC/PV port via the optional lead-acid battery charging cable, as
shown in the figure below.
Discharging
Besides the cigarette lighter port, USB-A, and USB-C, AC240P also features two types of AC outlets and an RV port, expanding your charging options.
AC Discharging
DC Discharging
Note:To ensure optimal performance, avoid short-circuiting the ports and keep them dry during use or storage. Additionally, do not block or cover the ports while ensuring proper ventilation.
Settings
The AC240P offers the convenience of adjusting its settings either via the LED screen or the BLUETTI App. With the unit’s LED screen,you have direct control over various settings such as Power Lifting Mode, ECO Mode, output frequency, and charging modes. Additionally, by using the BLU ETTI App, you can access a user-friendly interface on your phone to conveniently monitor and control the AC240P.
Setting Mode
When the screen is on, press and hold the AC and DC Power Buttons for about 2
seconds till the output frequency flashes to enter the Setting Mode.
ECO Mode
The AC240P has two ECO modes that help you save power and extend battery life:
- AC-ECO Mode In this mode, if the AC power output falls below a certain level for a set period of time, the AC power will automatically turn off.
Note: This mode is not available when the AC240P is charging from an AC source like a wall outlet or generator.
Note:This mode can only be configured using the BLUETTI App.
DC-ECO Mode
In this mode, if the DC power output falls below a certain level for a set
period of time, the DC power will automatically turn off.
Attention:
- The AC-ECO and DC-ECO modes are enabled by default to save energy, and it’s recommended to keep them enabled at all times.
- Use the BLUETTI App to enable or disable AC-ECO Mode and DC-ECO Mode separately.
- If you use the LED screen, they’ll be turned on or off at the same time.
- To avoid any interruption in charging, disable ECO Mode when charging a small device that consumes less than 60W of power. In the Setting Mode, press the DC Power Button to navigate through the setting items.
- When the ECO icon flashes on the screen, press the AC Power Button to enable or disable the ECO Mode.
Frequency Switching
The current output frequency (SO Hz/ 60Hz) is displayed in the lower right
corner of the screen. In the Setting Mode, press the DC Power Button to
navigate until the output frequency appears on the screen. Then, press the AC
Power Button to switch the frequency options based on your requirements.
Note: Turn off AC Power Button before setting Frequency.
WiFi & Bluetooth Connection
To connect the AC240P to the BLUETTI App, turn on the WiFi or Bluetooth first.
In the Setting Mode, press the DC Power button to navigate through the setting
items. When the * icon flashes on the screen, press the AC Power Button to
turn Bluetooth on. Similarly, when the icon flashes on the screen, press the
AC Power Button to toggle WiFi on.
Power Lifting Mode
The Power Lifting Mode is specifically designed to handle resistive loads up
to 3,600W, including electric blankets, kettles, hairdryers, and other heating
devices. To enable it, access the Setting Mode, navigate with the DC Power
Button until the C,: appears, and press the AC Power Button to enable the
mode.
Note: The Power Lifting Mode is not enabled by default and is only suitable
for resistive loads with a power rating between 2,400W-3,600W.
Although the AC240P can handle higher power demands, its actual operating
power remains at 2,400W. Also, the mode is not available when the AC240P is
working with another AC240P unit in parallel.
AC Charging Mode
The AC240P supports 3 AC charging modes – Standard, Turbo, and Silent to fit
your specific needs. In the Setting Mode, use the DC power button to navigate
until theWor?z icon starts flashing on the screen. Then, press the AC power
button to choose the charging modes.Please refer to the table below for useful
instructions.
UPS Mode
With the UPS mode enabled, the AC240P can provide uninterrupted power to your
essential appliances during a power outage. And there are four different
modes available through the BLUETTI App, allowing you to choose the best
option for your needs.
-
Standard UPS Mode
In this mode, the AC240P and its expansion batteries (if any) are always charged using available solar or grid power, ensuring that they are ready to provide backup power in case of a grid failure. When the grid fails, the AC240P units seamlessly take over to keep your devices running without any interruption.
Note: This mode is only available when two AC240P units are connected in parallel. -
Time Control UPS Mode
This mode allows you to program the AC240P to charge during off-peak hours when electricity is cheaper. Then, during peak hours when electricity is more expensive, the AC240P seamlessly switches over to power your devices, helping you to save money on your electricity bills. -
PV Priority UPS Mode
In this mode, the AC240P is mainly charged by solar energy to save power. You can also set a specific State of Charge (SoC) threshold. AC240P charges from the grid until reaching the designated SoC, and then seamlessly switches to solar charging for the remaining capacity. -
Customized UPS Mode
Tailor your UPS settings to match your unique needs in this mode. Create personalized schedules for charging and discharging, set battery SoC limits, and even control the grid charging switch and scheduled charging switch according to your diverse requirements.
Grid Self-adaption Mode
If you can not charge the AC240P using a generator or unstable grid voltage
because of unstable voltage, it is recommended that you enable the Grid Self-
adaption Mode through the BLUETTI App to ensure a stable, safe charging
experience for both theAC240P and your devices.
Max. Grid Input Current
The Max. Grid Input Current is set to 75A by default. If the grid current
doesn’t match this setting, adjust the setting in the BLUETTI App.
Attention:
A single AC240P unit allows a maximum grid input current of up to 20A.
If you need to increase the setting beyond the default 75A, please contact
BLUETTI Customer Service and request a password to make the necessary
adjustments.
Exit Setting Mode
To save your AC240P settings and exit the Setting Mode, press and hold down
both the DC and AC Power Buttons at the same time.
Note: If you do not perform any operation in l minute, the AC240P will
automatically exit the Setting Mode, and no changes will be saved.
AC240P + 8210P Expansion Connection
The AC240P unit supports up to 4 B270P expansion batteries, providing a total capacity of up to 70,443Wh. Follow these steps to connect the two units:
- Make sure both the AC240P and B270P are turned off.
- Connect them using the battery expansion cable.
- Power the AC240P on and the B270P turns on automatically. The ldisplays on the AC240P’s screen.
If you want to add more B270P units, please set up the system as shown.
Attention:
The AC240P connects to the upper battery expansion port of B270P.
Parallel Operation
To increase your power output, you can connect two AC240P units in parallel. When connected in this way, the two units can deliver up to 4,800W of power. To connect them, please follow these steps:
- Make sure both AC240P units are turned off.
- Connect them using the parallel box.
- Power on one AC240P unit, and the other unit will automatically turn on.
- When you connect your parallel system to a wall outlet, your devices will get power from either the grid or the system, depending on their power demand. If the demand is lower than 4,000W, they’ll get power directly from the grid. But if the demand is between 4,000W-4,800W, they’ll draw from the system.
Note:
All the settings made on one AC240P unit will be synchronized to the other
unit.
If you need to adjust the Max. Grid Input Current, please use the BLUETTI App
and make the necessary changes.
- Charge the two AC240Ps using the Parallel Charging Cable(with parallel box in Optional Accessories) in parallel mode.
BLUETTI App
Scan the QR code below or search “BLUETTI” in the App Store or Google Play to download the BLU ETTI App.
For more details, please refer to BLUETTI APP INSTRUCTIONS.
Specifications
Button Operation Instructions
Troubleshooting
In the Setting Mode press and hold the DC power button to switch the status page until the, Er icon and the error code appear simultaneously on the screen. Please refer to the table below for helpful guidance.
Appx. 1 Estimating Operation Time
To estimate the operation time of the AC240P, consider the load you’re
applying: Operation time = Battery Capacity (Wh) x DoD x ri -:- (Load Power+
AC240P Self-consumption)
Note: DoD refers to the depth of discharge. AC240P works at 95% DoD for longer
battery life. ri is the conversion efficiency of the inverter, typically over
85% for AC240P. Please keep in mind that the estimated operation time provided
is for reference purposes and may vary based on actual usage conditions.
Factors such as low temperature and excessive loads can significantly affect
the battery capacity, leading to a reduction in the average operation time.
Appx. 2 FAQ
-
Ql: How do I know whether my devices will work well with this product?
A: Please evaluate the total constant load of your devices. If it doesn’t exceed the Max. output power of AC240P (2400W), you can use this power station to run your devices.
Note: Some devices with built-in motors or compressors may start at 2-4 times the rated power, which can easily overload the AC240P. -
Q2: Can I use third-party solar panels to charge this product?
A: Yes, you can. However, make sure your solar panels have an open circuit voltage of llV-60V and are equipped with MC4 connectors. It’s also important not to mix different types of solar panels. -
Q3: Can it charge and discharge at the same time?
A: Yes. It supports pass-through charging. The AC240P comes with the premium LiFePO4 battery and proprietary Battery Management System to ensure that it can charge and discharge at the same time. -
Q4: Why is the charging power often too low?
A: AC240P has a built-in intelligent BMS that automatically adjusts the charging power in response to the battery temperature and Soc, thus protecting the battery and
Appx. 3 FCC Statement
This device complies with part 75 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 75 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio /TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
IMPORTANT NOTE: FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance of 20cm between the radiator &your body.
Appx. 4 IC Caution
This device contains licence-exempt transmitter(s) / receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
RF exposure statement: The equipment complies with IC Radiation exposure
limits set forth for uncontrolled environments. This equipment should be
installed and operated with a minimum distance of 20cm between the radiator
and your body.
CAN ICES-3 (B)/NMB-3(8) (Canada)
This Class B digital apparatus complies with Canadian ICES-003.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>