BAVARIA 301 Sailing Yacht Main Panel Instruction Manual

June 3, 2024
BAVARIA

BAVARIA 301 Sailing Yacht Main Panel

Introduction and Overview

Two panels are available for the operation and power supply. Panel 301 is designed for central monitoring and control of all electrical functions on board the yacht. Panel 302 supplies the 230V devices with power when there is a land connection.BAVARIA-301-Sailing-Yacht-Main-Panel-
fig-1

Fig. 1 Overview – panel 301/302

Key

  1. Panel 301
  2. Panel 302

Panel 301 ControlsBAVARIA-301-Sailing-Yacht-Main-Panel-
fig-2 Fig. 2 Overview of panel 301

Key

  1. Display
  2. Scroll and acknowledgment buttons
  3. Socket 12V/20A
  4. Function buttons
  5. Lighting buttons

The current status of the function and lighting buttons is shown by the respective LED.

LED Status Meaning
Yellow LED on Button function is switched on
Yellow LED flashes Malfunction
Yellow LED off Button function is switched off

Function ButtonsBAVARIA-301-Sailing-Yacht-Main-Panel-
fig-3BAVARIA-301-Sailing-Yacht-Main-Panel-
fig-4

Lighting Buttons
These buttons are used to switch the various lighting sources on and off. The button status is saved when the power supply has been switched off and is kept until the power is switched back on again.

Fig. 3 Detailed view of the lighting buttons

Outside lighting
The yellow LED will flash in the event of a malfunction.

  • Stern
  • Bow
  • Steam
  • Mast head

No function monitoring for:

  • Deck flood

Inside lighting

  • Cabin 1
  • Cabin 2

This section describes how to access the various menu functions and how to change settings. 1 As soon as the panel is connected to the power source, a function test will be performed and the LEDs will light up for approx. 1 second. After this, the panel is ready for operation. Alarms will be shown when triggered. See also section 1.2.2.
After activating the main switch, you will see the following start screen on the display:

With the help of the scroll buttons and the acknowledgment button, you can select and view the various information and menus.BAVARIA-301-Sailing-Yacht-
Main-Panel-fig-6

You can now perform the required settings at the panel.

BAVARIA-301-Sailing-Yacht-Main-Panel-fig-7

Alarms

If an alarm is triggered, the red LED next to the display will flash. The display will show the menu which has issued the alarm and the alarm itself will be shown by a flashing exclamation mark next to the menu bar. To acknowledge the alarm, press the acknowledgment button for 2 seconds. 1BAVARIA-301-Sailing-Yacht-Main-Panel-fig-8

The red LED extinguishes when you acknowledge the alarm.

Overview of Panel 302

Panel 302 supplies the 230V devices with power when there is a land connection.

WARNING
Observe the current consumption and power input

  • The consumer devices connected must not exceed a total power input of 3.600 W and a max current consumption of 16 A.BAVARIA-301-Sailing-Yacht-Main-Panel-fig-9

Fig. 6 Overview of panel 302

Key

  1. Installation point for radio (optional)
  2. LED (green) for residual current circuit breaker
  3. Residual current circuit breaker FI /B16
  4. Observe warning symbols
  5. Automatic circuit breaker – kitchen (16A)
  6. Automatic circuit breaker – shower (16A)
  7. Automatic circuit breaker – boiler (16A)
  8. Socket 220V (9) LED (red) for boiler on

Function description

  • When the residual current circuit breaker is switched on, a green LED indicates the existing land connection.
  • The red LED indicates that the heating boiler is switched on.
  • The residual current circuit breaker and fuse B16 are connected upstream of the three auto-matic circuit breakers (5,6,7).
  • The kitchen fuse also serves the integrated socket (8).

Warning Symbols on Panel 302BAVARIA-301-Sailing-Yacht-Main-Panel-
fig-10

Electrical Connections

Safety Instructions

DANGER
Panel 302 is supplied with 230 V~ ± 5 %, 50/60 Hz line voltage.

  • Potentially lethal voltages are therefore still present at some parts on the rear of this panel (in-put B16/FI) – even when the panel has been switched off at the residual current circuit breaker.
  • Measurement and service work to panels 301/302 may only be performed by specially quali-fied personnel.
  • Incorrect usage of panels 301/302 may cause serious or even lethal injuries and considerable damage to property.
  • The safety instructions and hazard warnings in the boatbuilder’s operating manual take prece-dence when using panels 301/302.
  • Observe the applicable accident prevention and DIN regulations (particularly DIN EN 60 204, Part 1) or the respective regulations in your country.
  • Before performing any service or maintenance work, always switch off panel 302 at the resid-ual current circuit breaker and disconnect it from the power supply.
  • Secure the panel to prevent unauthorized reconnection of the power supply. Touching live parts can lead to serious or lethal injuries.

Rear View of Panel 301

The connections and micro-fuses can be found on the rear of the operating panel 301. Loosen the two fastening screws at the front and swing the panel open to the side.BAVARIA-301-Sailing-Yacht-Main-Panel-
fig-11

Fig. 7 Rear view of the panel 301 – terminal assignment

Key

  1. Monitoring of fresh water tank 2 (bow)
  2. Monitoring of waste tank 2
  3. Monitoring of fresh water tank 1 (AC)
  4. Monitoring of waste tank 1
  5. Monitoring of charger
  6. Monitoring of diesel tank (not used)
  7. Bow cable (not used)
  8. Stern cable
  9. Bilge pump
  10. Anchor
  11. Battery – negative pole
  12. Socket 12V with fuse
  13. Battery – positive pole 12C DC
  14. Reserve function buttons F1-F5
  15. Shower suction extractor pump
  16. Light cable
  17. Shower suction extractor pump
  18. Fridge

Terminal Assignment

Connector [1] Monitoring fresh water tank 2 (bow) Cable
1 Fresh water tank 2 4/4, wt
2 Fresh water tank 2 3/4, br
3 Fresh water tank 2 2/4, gr
4 Fresh water tank 2 1/4, ye
5 Fresh water tank 2 COM/GND
Connector [2] + [4] Monitoring waste tank Cable
--- --- ---
1 Waste tank 1 3/4
2 Waste tank 2 COM/GND
Connector [3] Monitoring fresh water tank 1 (stern) Cable
--- --- ---
1 Fresh water tank 1 4/4, wt
2 Fresh water tank 1 3/4, br
3 Fresh water tank 1 2/4, gr
4 Fresh water tank 1 1/4, ye
5 Fresh water tank 1 COM/GND
Connector [5] Monitoring charger Cable
--- --- ---
1 GND input
2 LED input
Connector [6] Monitoring diesel tank Cable
--- --- ---
1 Not used
2 Not used
3 Not used
Connector [7] Bow cable (only for Match series) Cable
--- --- ---
1 Top light – not used 1
2 Steam light – not used 2
3 Sailing light – not used 3
4 Fresh water pump – not used 12

Connector

| [8] Stern cable, plus option cable|

Cable

|

Description

| Connectio n
---|---|---|---|---
1| Stern light| 1| Function monitoring

Button

| 10W/2A
2| Compass light| 2| No function monitoring

Button

| 10W/1A
3| Fresh water pump| 3| No function monitoring

Button

| 90W/8A
4| Navigation instrument| 4| Monitoring fuses| 240W/20A
 | (autopilot and chart plotter option)| [item14] factory configuratio n or [item15] optional| Button|
5| Fresh water pump| 5| No function monitoring

Button

| 90W/8A

Connector

|

[9] Bilge pump

|

Cable

|

Description

| Connectio n
---|---|---|---|---
 | Bilge pump| 11| Function monitoring Button

Pump 12V

| 80W/10A

Connector

|

[10] Windlass

|

Cable

|

Description

| Connectio n
---|---|---|---|---
 | Windlass| 10| No function monitoring Button

Control external power relay

| 60W/5A

Connector

|

[12] Socket

|

Cable

|

Description

| Connectio n
---|---|---|---|---
 | Socket 12V| 17| No function monitoring

NOT switched

| 192W/16A

Connector

| [14] Reserved for function buttons F1-F5|

Cable

|

Description

| Connectio n
---|---|---|---|---
1| Reserve button 1| —| No function monitoring

Button

| 60W/5A
2| Reserve button 2| —| No function monitoring

Button

| 60W/5A
3| Reserve button 3| —| No function monitoring

Button

| 60W/5A
4| Reserve button 4| —| No function monitoring

Button

| 180W/15A
5| Reserve button 5| —| No function monitoring

Button

| 240W/20A

Connector

|

[16] Light cable

|

Cable

|

Description

| Connectio n
---|---|---|---|---
1| 12 V battery 1+, starter battery, connection only for measuring battery| 1| —| —
2| !Not connected, occupied internally!| —| —| —
3| Top light| 3| Function monitoring

Button

| 10W/1A
4| Steam light| 4| Function monitoring

Button

| 25W/2A
5| Bow light| 5| Function monitoring

Button

| 25W/2A
6| Sailing light| 6| No function monitoring

Button

| 50W/4A
7+8| Inside lighting 1+2| 7+8| No function monitoring

Button

| 240W/20A
9+10| Inside lighting 3+4| 9+10| No function monitoring

Button

| 240W/20A

Connector

|

[16] Light cable

|

Cable

|

Description

| Connectio n
---|---|---|---|---
11| Heating| 11| No function monitoring Button

Control line for thermostat

| 60W/5A
12| Radio (optional)| 12| Function monitoring

Button

| 120W/10A
 | CB radio (optional)| —| Function monitoring

Button

|

Connector

| [17] Sower suction extractor pump|

Cable

|

Description

| Connectio n
---|---|---|---|---
 | Shower suction extractor pump| 13+13a+

13b

| No function monitoring

Button

| 270W/30A
Connector| [18] Fridge| Cable|  | Cable
---|---|---|---|---
 | Cooling unit| 16+16a+

16b+16c

| Monitoring fuses

Button

| 360W/30A

BAVARIA-301-Sailing-Yacht-Main-Panel-fig-12

Fig. 8 Rear view of the panel 301 – micro-fuses

Key

  1. Water pump (10A)
  2. Cooling unit (30A)
  3. Shower pump (30A)
  4. Inside lighting cabin 1 (20A)
  5. Inside lighting cabin 2 (20A)
  6. Navigation (20A)
  7. Reserve button (20A)
  8. Reserve button (15A)
  9. Socket (16A)

WARNING
Note the current value for the micro fuses

Rear View of Panel 302

DANGER
Panel 302 is supplied with 230 V~ ± 5 %, 50/60 Hz line voltage.

  • Observe the safety instructions in section „Safety Instructions“

Terminal AssignmentBAVARIA-301-Sailing-Yacht-Main-Panel-
fig-13

Fig. 9 Rear view of the panel 302 – terminal assignment

Key

  1. 1 x Boiler
  2. 3 x Shower
  3. 3 x Kitchen
  4. AC mains for land connection
  5. Mains socket

NOTE:
The protective earth conductor (PE) must be attached to the middle pin

Circuit Diagram

BAVARIA-301-Sailing-Yacht-Main-Panel-
fig-14