the t amp E-400 Power Amplifier User Manual
- June 29, 2024
- the t amp
Table of Contents
E-400 Power Amplifier
Product Information
Specifications
- Model: E-400, E-800, E-1200, E-1500 Power Amplifier
- Date: 08.05.2024
- IDs: 173888, 173889, 460282, 460283 (V6)
General Information
The E-400, E-800, E-1200, E-1500 Power Amplifier is designed to
amplify electric audio frequency signals to operate passive
speakers.
Safety Instructions
Intended Use
Use the device only as described in the user manual. Any other
use or use under different operating conditions may result in
personal injury or property damage. This device should only be used
by individuals with sufficient knowledge and experience.
Safety
DANGER! Risk of injury and choking hazard for
children. Danger to life due to electric current. Do not remove
covers as high voltages may be present. Do not use the device if
safety equipment is missing or damaged.
DANGER! A short circuit could lead to a fire
hazard and risk of death. Always use proper insulated mains cable
with a safety plug. Do not modify the cable or plug. Seek advice
from a qualified electrician in case of isolation damage.
WARNING! Possible hearing damage due to high
volumes on speakers or headphones. Avoid prolonged exposure to high
volume levels to prevent hearing impairment. Decrease volume
immediately if you experience hearing issues.
Product Usage Instructions
-
Connect the power amplifier to passive speakers using
appropriate cables. -
Ensure all connections are secure before powering on the
device. -
Refer to the user manual for specific setup instructions based
on your audio system. -
Avoid operating the device at excessively high volume levels to
prevent hearing damage. -
In case of any issues or doubts about the device’s operation,
seek assistance from a qualified technician.
FAQ
Q: How can I prevent hearing damage while using the power
amplifier?
A: Avoid prolonged exposure to high volume levels and decrease
the volume immediately if you experience any hearing impairment
symptoms like ringing in your ears.
Q: Can I use the power amplifier with active speakers?
A: No, this power amplifier is designed specifically for use
with passive speakers.
User Manual
E-400, E-800, E-1200, E-1500
Power Amplifier
Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0)
9546 9223-0 Internet: www.thomann.de
08.05.2024, ID: 173888, 173889, 460282, 460283 (V6)
Table of contents
Table of contents
1 General information………………………………………………………………………………………………………………… 5 1.1 Symbols
and signal words………………………………………………………………………………………………… 5
2 Safety instructions……………………………………………………………………………………………………………………. 7 3
Features……………………………………………………………………………………………………………………………………. 10 4 Installation
and starting up…………………………………………………………………………………………………. 11 5 Connections and
operating elements………………………………………………………………………………. 15 6 Technical
specifications……………………………………………………………………………………………………….. 23 7 Plug and
connection assignment………………………………………………………………………………………. 32 8
Cleaning……………………………………………………………………………………………………………………………………. 36 9 Protecting
the environment……………………………………………………………………………………………….. 37
3 E-400, E-800, E-1200, E-1500
Power Amplifier
4 E-400, E-800, E-1200, E-1500 Power Amplifier
General information
1 General information
This document contains important instructions for the safe operation of the
product. Read and follow the safety instructions and all other instructions.
Keep the document for future refer- ence. Make sure that it is available to
all those using the product. If you sell the product to another user, be sure
that they also receive this document. Our products and documentation are
subject to a process of continuous development. They are therefore subject to
change. Please refer to the latest version of the documentation, which is
ready for download under www.thomann.de.
1.1 Symbols and signal words
In this section you will find an overview of the meaning of symbols and signal
words that are used in this document.
5 E-400, E-800, E-1200, E-1500
Power Amplifier
General information
Signal word DANGER! WARNING! NOTICE!
Warning signs
Meaning This combination of symbol and signal word indicates an immediate
dangerous situation that will result in death or serious injury if it is not
avoided. This combination of symbol and signal word indicates a pos- sible
dangerous situation that can result in death or serious injury if it is not
avoided. This combination of symbol and signal word indicates a pos- sible
dangerous situation that can result in material and environmental damage if it
is not avoided.
Type of danger Warning high-voltage.
Warning danger zone.
6 E-400, E-800, E-1200, E-1500 Power Amplifier
Safety instructions
2 Safety instructions
Intended use
This device amplifies electric audio frequency signals to operate passive
speakers. Use the device only as described in this user manual. Any other use
or use under other operating con- ditions is considered to be improper and may
result in personal injury or property damage. No liability will be assumed for
damages resulting from improper use.
This device may be used only by persons with sufficient physical, sensorial,
and intellectual abilities and having corresponding knowledge and experience.
Other persons may use this device only if they are supervised or instructed by
a person who is responsible for their safety.
Safety
DANGER!
Risk of injury and choking hazard for children!
Children can suffocate on packaging material and small parts. Children can
injure themselves when handling the device. Never allow children to play with
the packaging material and the device. Always store packaging material out of
the reach of babies and small children. Always dispose of packaging material
properly when it is not in use. Never allow children to use the device without
supervi- sion. Keep small parts away from children and make sure that the
device does not shed any small parts (such knobs) that children could play
with.
DANGER!
Danger to life due to electric current!
Within the device there are areas where high voltages may be present. Never
remove any covers. There are no user-serviceable parts inside. Do not use the
device when covers, safety equipment or optical components are missing or
damaged.
7 E-400, E-800, E-1200, E-1500
Power Amplifier
Safety instructions
DANGER! Danger to life due to electric current! A short circuit could lead to
a fire hazard and risk of death. Always use proper ready-made insulated
triple-core mains cable with a safety plug. Do not modify the mains cable or
the plug. In case of isolation damage, disconnect immediately the power supply
and arrange repair. If in doubt, seek advice from a qualified electrician.
WARNING! Possible hearing damage due to high volumes on speakers or
headphones! With speakers or headphones connected, the device can produce
volume levels that may cause temporary or permanent hearing impairment. Over
an extended period of time, even levels that seem to be uncritical can cause
hearing damage. Do not operate the device permanently at a high volume level.
Decrease the volume level immediately if you experience ringing in your ears
or hearing impairment.
NOTICE! Risk of fire due to covered vents and neighbouring heat sources! If
the vents of the device are covered or the device is operated in the immediate
vicinity of other heat sources, the device can over- heat and burst into
flames. Never cover the device or the vents. Do not install the device in the
immediate vicinity of other heat sources. Never operate the device in the
immediate vicinity of naked flames.
NOTICE! Damage to the device if operated in unsuitable ambient conditions! The
device can be damaged if it is operated in unsuitable ambient conditions. Only
operate the device indoors within the ambient conditions specified in the
“Technical specifications” chapter of this user manual. Avoid operating it in
environments with direct sun- light, heavy dirt and strong vibrations. Avoid
operating it in environments with strong temperature fluctuations. If
temperature fluc- tuations cannot be avoided (for example after transport in
low outside temperatures), do not switch on the device immediately. Never
subject the device to liquids or moisture. Never move the device to another
location while it is in operation. In environments with increased dirt levels
(for example due to dust, smoke, nicotine or mist): Have the device cleaned by
qualified specialists at reg- ular intervals to prevent damage due to
overheating and other malfunctions.
8 E-400, E-800, E-1200, E-1500 Power Amplifier
Safety instructions
NOTICE! Damage to the device due to high voltages! The device can be damaged
if it is operated with the incorrect voltage or if high voltage peaks occur.
In the worst case, excess vol- tages can also cause a risk of injury and
fires. Make sure that the voltage specification on the device matches the
local power grid before plugging in the device. Only operate the device from
professionally installed mains sockets that are protected by a residual
current circuit breaker (FI). As a precaution, disconnect the device from the
power grid when storms are approaching or it the device will not be used for a
longer period. NOTICE! Interference with nearby electrical devices due to
magnetic fields! The device generates strong magnetic fields that can
interfere with the function of poorly shielded devices. The magnetic fields
are strongest directly above and below the Power Amplifier. You should
therefore never place sensitive devices such as pre-amplifiers, radio
transmission systems, or tape decks directly above or below the Power
Amplifier. When placing the Power Amplifier in a rack, you should place it at
the bottom thereof, and place any other equipment at the top of the rack.
NOTICE! Risk of fire due to installation of a wrong fuse! Using fuses of a
different type than compatible with the device may cause a fire and seriously
damage the device. Only use fuses of the same type. Observe the labelling on
the device casing and the information in the “Technical data” chapter. NOTICE!
Possible staining due to plasticiser in rubber feet! The plasticiser contained
in the rubber feet of this product may react with the coating of the floor and
cause permanent dark stains after some time. If necessary, use a suitable mat
or felt slide to prevent direct contact between the device’s rubber feet and
the floor.
9 E-400, E-800, E-1200, E-1500
Power Amplifier
Features
3 Features
n Shallow installation depth n Inputs: XLR, phone jack (balanced) and cinch (only for item no. 173888) n Outputs: Speaker Twist and terminal clamps for speakers n Protection circuits: DC, short circuit, over-temperature protection, limiter n Standby function, can be deactivated (only in item no. 173888 and item no. 173889)
10 E-400, E-800, E-1200, E-1500 Power Amplifier
Installation and starting up
4 Installation and starting up
Unpack and check carefully there is no transportation damage before using the
unit. Keep the equipment packaging. To fully protect the product against
vibration, dust and moisture during transportation or storage use the original
packaging or your own packaging material suitable for transport or storage,
respectively.
Create all connections while the device is off. Use the shortest possible
high-quality cables for all connections. Take care when running the cables to
prevent tripping hazards.
DANGER! Risk of death from electrical current! The output voltages of modern
high-performance amplifiers may result in death or serious injury. Never touch
the bare ends of loudspeaker cables when the amplifier is on.
11 E-400, E-800, E-1200, E-1500
Power Amplifier
Installation and starting up
NOTICE!
Interference with nearby electrical devices due to magnetic fields!
The device generates strong magnetic fields that can interfere with the
function of poorly shielded devices. The magnetic fields are strongest
directly above and below the Power Amplifier.
You should therefore never place sensitive devices such as pre-amplifiers,
radio transmission systems, or tape decks directly above or below the Power
Amplifier. When placing the Power Amplifier in a rack, you should place it at
the bottom thereof, and place any other equipment at the top of the rack.
12 E-400, E-800, E-1200, E-1500 Power Amplifier
Possible operation modes Stereo mode Parallel mode Bridged mode
Installation and starting up
Depending on the individual application, the amplifier can be used in
different operation modes:
The two amplifier channels operate independently of one another, either
channel (A and B) is amplified and connected to loudspeakers, the volume can
be controlled separately for the two outputs.
The two amplifier channels receive the same input signal from channel A and
loudspeakers are connected to each amplifier, the volume is controlled via the
control knob for channel A.
The two amplifier channels are internally connected in such a way that twice
the output power is available. Only the input signal from channel A is
amplified and loudspeakers are connected only to the correspondingly marked
output. The volume is controlled via the control knob for channel A. For each
output of the amplifier, the total impedance resulting from the loudspeakers
con- nected to it must not be below the allowed minimal impedance of the
amplifier output. If you connect more than one loudspeaker to an amplifier
output, please note the following: n If the loudspeakers are connected in a
series, the individual impedances will be added up.
13 E-400, E-800, E-1200, E-1500
Power Amplifier
Installation and starting up
Rack mounting
n If the loudspeakers are connected in parallel, the reciprocal of the total
impedance equals the sum of the reciprocals of the individual impedances.
Example: If you have two loudspeakers with the same impedance, their impedance
doubles if they are connected in a series, their impedance halves if they are
connected in parallel. For detailed information related to this topic please
refer to our Online Guide `PA Speakers’ (www.thomann.de).
The device has been designed for rack mounting in a standard 19-inch rack; it
occupies two rack units.
14 E-400, E-800, E-1200, E-1500 Power Amplifier
5 Connections and operating elements
Front panel
Connections and operating elements
$
%
1 [POWER] | Mains switch. Turns the device on and off. 2 LED panel
[SIG] | Indicates the presence of an input signal.
ö 15 E-400, E-800, E-1200, E-1500
Power Amplifier
Connections and operating elements
[CLIP] | Lights under the following conditions: n Channel overload
Reduce in this case the volume until the LED goes out. n Output short circuit
Turn off the device immediately, correct the short circuit and turn on the
device again. [PRO] | Lights under the following conditions: n Three to five
seconds after switching on or off when the device is in an unstable condition.
n The temperature of the amplifier blocks has reached 85°C. n One or more
protection circuits have been triggered, or the device is faulty. [POWER] |
Lights up green when the device is turned on. In standby mode, the LED lights
red. As soon as the unit receives a signal, it switches back to normal mode
and the LED will light up green again. [PAR] | Lights when the device is
operated in parallel mode. [BR] | Lights when the device is operated in
bridged mode. 3, 4 [CHANNEL A], [CHANNEL B] | Volume control for the
respective channel
16 E-400, E-800, E-1200, E-1500 Power Amplifier
Rear panel E-400
‘
STANDBY
Connections and operating elements
&
( ) *+,- .
/
5 IEC chassis plug with fuse holder 6 [ON] [OFF] [STANDBY] | On / off switch
for standby function. If the standby function is enabled, the device automati-
cally switches to standby mode after fifteen minutes without any input signal.
17 E-400, E-800, E-1200, E-1500
Power Amplifier
Connections and operating elements
7, 8 [OUTPUT] | Output channel B, A n Speaker Twist chassis connector for
speaker output (1+, 2+: positive; 1, 2: negative) n Screw terminals
9 [GROUND] [LIFT] | Ground / lift switch. If hum is caused by a ground loop,
you can use this switch to disconnect the connection between the earth pin of
the device and the signal ground of the device.
10 [LIMITER] | Limits the output level so that the maximum distortion is 5%.
11 Selector switch for operating mode
n [PAR]: Parallel mode n [STE]: Stereo mode n [BR]: Bridged mode 12 Selector
switch for input sensitivity 13, 14 [INPUT] | Input channel B, A n XLR chassis
socket n ¼-inch (6.35-mm) jack (balanced or unbalanced) n RCA socket
18 E-400, E-800, E-1200, E-1500 Power Amplifier
Rear panel E-800
12
:
STANDBY BREAKER
PUSH
PUSH
Bridge Stereo Parallel
1.4V 26dB 0.77V
LIMITER
0
3 4 56 78 9
Connections and operating elements ;
15 Power cord 16 [ON] [OFF] [STANDBY] | On / off switch for standby function.
If the standby function is enabled, the device automati-
cally switches to standby mode after fifteen minutes without any input signal.
19 E-400, E-800, E-1200, E-1500
Power Amplifier
Connections and operating elements
17 [BREAKER] | Resettable fuse. The fuse switches off when the power
consumption of the power amplifier is too high. Once the problem is resolved,
the fuse is automatically reset and the device is ready for use again. The
switch can be used to force the reset.
18, 19 [OUTPUT] | Output channel B, A n Speaker Twist chassis connector for
speaker output (1+, 2+: positive; 1, 2: negative) n Screw terminals
20, 22 [INPUT] | Input channel B, A n XLR chassis socket n ¼-inch (6.35-mm)
jack (balanced or unbalanced)
21 [GROUND] [LIFT] | Ground / lift switch. If hum is caused by a ground loop,
you can use this switch to disconnect the connection between the earth pin of
the device and the signal ground of the device.
23 [LIMITER] | Limits the output level so that the maximum distortion is 5%.
24 Selector switch for input sensitivity 25 Selector switch for operating mode
n [Parallel]: Parallel mode n [Stereo]: Stereo mode n [Bridge]: Bridged mode
20 E-400, E-800, E-1200, E-1500 Power Amplifier
Rear panel E-1200, E-1500
Connections and operating elements
PUSH
PUSH
<
= > ?A B
27 IEC panel plug 28, 29 [OUTPUT] | Output channel B, A
n Speaker Twist chassis connector for speaker output (1+, 2+: positive; 1,
2: negative) n Screw terminals
21 E-400, E-800, E-1200, E-1500
Power Amplifier
Connections and operating elements
30, 32 [INPUT] | Input channel B, A n XLR chassis socket (male) n XLR chassis
socket (female)
31 Selector switch for operating mode n [PAR]: Parallel mode n [STR]: Stereo
mode n [BRI]: Bridged mode
22 E-400, E-800, E-1200, E-1500 Power Amplifier
Technical specifications
6 Technical specifications
E-400 (item no. 173888) Amplifier class Input connections
Input impedance Output connections Output power
AB 1 × Rubber panel plug C14 2 × XLR socket, 3-pin 2 × 6.35-mm jack socket 2 × cinch socket 20 k (balanced) 10 k (unbalanced) 2 × Speaker Twist panel connector 4 × screw terminal Power @ 1 kHz, 1 % THD+N (continuous EN60268-3, peak CEA-2006, max. gain) Stereo/parallel, 8 : Stereo/parallel, 4 : Bridged, 8 :
Continuous
Peak
2 × 155 W 2 × 310 W 450 W
2 × 190 W 2 × 360 W 530 W
23 E-400, E-800, E-1200, E-1500
Power Amplifier
Technical specifications
Frequency response Signal-to-noise ratio Total harmonic distortion (THD)
Damping factor (1 kHz, 8 ) Sensitivity Gain Crosstalk at rated power @ 8 , 1
kHz Maximum power consumption @ 1 kHz, 0 dBu, 230 V
Inrush current Supply voltage Fuse
Dimensions (W × H × D) Weight Ambient conditions
20 Hz…20 kHz, ±0.1 dB
90 dB
0.01% at -3 dBu
220
0.775 V / 26 dB / … 1.4 V
34 dB (0.77 V), 28 dB (1.4 V)
-59 dB
900 W @ 4
550 W @ 8
50 A, 0.3 µs
230 V 50 Hz
DC: 5 mm × 20 mm, 12 A, 250 V, slow blow AC: 5 mm × 20 mm, 8 A, 250 V, slow blow
482 mm × 88 mm × 317 mm
8.6 kg
Temperature range
0 °C…40 °C
Relative humidity
20%…80% (non-condensing)
24 E-400, E-800, E-1200, E-1500 Power Amplifier
E-800 (item no. 173889) Amplifier class Input connections Input impedance
Output connections Output power
Frequency response Signal-to-noise ratio Total harmonic distortion (THD)
Damping factor (1 kHz, 8 )
Technical specifications
H, 2 stages 2 × XLR socket, 3-pin 2 × 6.35-mm jack socket 20 k (balanced) 10 k (unbalanced) 2 × Speaker Twist panel connector 4 × screw terminal Power @ 1 kHz, 1 % THD+N (continuous EN60268-3, peak CEA-2006, max. gain) Stereo/parallel, 8 : Stereo/parallel, 4 : Bridged, 8 : 20 Hz…20 kHz, ±0.1 dB 89 dB 0.04% at -8 dBu > 160
Continuous
2 × 360 W 2 × 490 W 990 W
Peak
2 × 420 W 2 × 590 W 1210 W
25 E-400, E-800, E-1200, E-1500
Power Amplifier
Technical specifications
Sensitivity Gain Crosstalk at rated power @ 8 , 1 kHz Maximum power
consumption @ 1 kHz, 0 dBu, 230 V
Inrush current Supply voltage Fuse
Dimensions (W × H × D) Weight Ambient conditions
0.775 V / 26 dB / … 1.4 V
36 dB (0.77 V), 31 dB (1.4 V)
-53 dB
1750 W @ 4
950 W @ 8
11.4 A, 4.6 µs
230 V 50 Hz
DC: 5 mm × 20 mm, 10 A, 250 V, slow blow DC: 5 mm × 20 mm, 15 A, 250 V, slow blow AC: RFMB-103-11D3N-B-A (88 series, 10 A, 250 V)
482 mm × 88 mm × 375 mm
12.8 kg
Temperature range
0 °C…40 °C
Relative humidity
20%…80% (non-condensing)
26 E-400, E-800, E-1200, E-1500 Power Amplifier
E-1200 (item no. 460282) Amplifier class Input connections Input impedance
Output connections Output power
Frequency response Signal-to-noise ratio Total harmonic distortion (THD)
Damping factor (1 kHz, 8 )
Technical specifications
H 1 × Rubber panel plug C14 4 × XLR socket, 3-pin 20 k (balanced) 10 k (unbalanced) 2 × Speaker Twist panel connector 4 × screw terminal Power @ 1 kHz, 1 % THD+N (continuous EN60268-3, peak CEA-2006, max. gain) Stereo/parallel, 8 : Stereo/parallel, 4 : Bridged, 8 : 20 Hz…20 kHz, ±0.1 dB 98 dB 0.03% at -7 dBu > 200
Continuous
2 × 680 W 2 × 990 W 1980 W
Peak
2 × 840 W 2 × 1300 W 2470 W
27 E-400, E-800, E-1200, E-1500
Power Amplifier
Technical specifications
Sensitivity Gain Crosstalk at rated power @ 8 , 1 kHz Maximum power
consumption @ 1 kHz, 0 dBu, 230 V
Inrush current Supply voltage Fuse
Dimensions (W × H × D) Weight Ambient conditions
0.77 V / 26 dB / … 1.4 V
41 dB
-61 dB
3200 W @ 4
2000 W @ 8
12 A, 4 µs
115/230 V 50/60 Hz
DC: 5 mm × 20 mm, 10 A, 250 V, slow blow DC: 5 mm × 20 mm, 20 A, 250 V, slow blow
482 mm × 88 mm × 362 mm
15.3 kg
Temperature range
0 °C…40 °C
Relative humidity
20%…80% (non-condensing)
28 E-400, E-800, E-1200, E-1500 Power Amplifier
E-1500 (item no. 460283) Amplifier class Input connections Input impedance
Output connections Output power
Frequency response Signal-to-noise ratio Total harmonic distortion (THD)
Damping factor (1 kHz, 8 )
Technical specifications
H 1 × Rubber panel plug C14 4 × XLR socket, 3-pin 20 k (balanced) 10 k (unbalanced) 2 × Speaker Twist panel connector 4 × screw terminal Power @ 1 kHz, 1 % THD+N (continuous EN60268-3, peak CEA-2006, max. gain) Stereo/parallel, 8 : Stereo/parallel, 4 : Bridged, 8 : 20 Hz…20 kHz, ±0.1 dB 97 dB 0.04% at -7 dBu > 200
Continuous
2 × 850 W 2 × 1220 W 2440 W
Peak
2 × 1050 W 2 × 1700 W 3360 W
29 E-400, E-800, E-1200, E-1500
Power Amplifier
Technical specifications
Sensitivity Gain Crosstalk at rated power @ 8 , 1 kHz Maximum power
consumption @ 1 kHz, 0 dBu, 230 V
Inrush current Supply voltage Fuse
Dimensions (W × H × D) Weight Ambient conditions
0.77 V / 26 dB / … 1.4 V
41 dB
-60 dB
4200 W @ 4
2500 W @ 8
12 A, 4 µs
115/230 V 50/60 Hz
DC: 5 mm × 20 mm, 12 A, 250 V, slow blow DC: 5 mm × 20 mm, 25 A, 250 V, slow blow
482 mm × 88 mm × 362 mm
16.0 kg
Temperature range
0 °C…40 °C
Relative humidity
20%…80% (non-condensing)
30 E-400, E-800, E-1200, E-1500 Power Amplifier
Further information
2- stable
No
DSP / crossover
No
Convection cooling
No
Technical specifications
31 E-400, E-800, E-1200, E-1500
Power Amplifier
Plug and connection assignment
7 Plug and connection assignment
Introduction
This chapter will help you select the right cables and plugs to connect your
valuable equip- ment in such a way that a perfect sound experience is ensured.
Please note these advices, because especially in Sound & Light’ caution is indicated: Even if a plug fits into the socket, an incorrect connection may result in a destroyed power amp, a short circuit or
just’ in poor
transmission quality!
Balanced and unbalanced trans- mission
Unbalanced transmission is mainly used in semi-professional environment and in
hifi use. Instrument cables with two conductors (one core plus shielding) are
typical representatives of the unbalanced transmission. One conductor is
ground and shielding while the signal is trans- mitted through the core.
Unbalanced transmission is susceptible to electromagnetic interference,
especially at low levels, such as microphone signals and when using long
cables.
In a professional environment, therefore, the balanced transmission is
preferred, because this enables an undisturbed transmission of signals over
long distances. In addition to the conduc- tors Ground’ and
Signal’, in a
balanced transmission a second core is added. This also transfers the signal,
but phase-shifted by 180°.
Since the interference affects both cores equally, by subtracting the phase-
shifted signals, the interfering signal is completely neutralized. The result
is a pure signal without any noise inter- ference.
32 E-400, E-800, E-1200, E-1500 Power Amplifier
1/4″ TS phone plug (mono, unbalanced)
1 2
1/4″ TRS phone plug (mono, bal- anced)
1 2 3
1/4″ TRS phone plug (stereo, unbalanced)
1 2 3
Signal Ground, shielding
Signal (in phase, +) Signal (out of phase, ) Ground
Signal (left) Signal (right) Ground
Plug and connection assignment
33 E-400, E-800, E-1200, E-1500
Power Amplifier
Plug and connection assignment
XLR plug (balanced) 1 2 3 4
XLR plug (unbalanced) 1 2 3
Ground, shielding Signal (in phase, +) Signal (out of phase, ) Shielding on
plug housing (option)
Ground, shielding Signal Bridged to pin 1
34 E-400, E-800, E-1200, E-1500 Power Amplifier
Plug and connection assignment
Speaker Twist chassis connector
1, +
1,
2, +
2,
ö
Signal 1 (in phase) Signal 1 (out of phase) Signal 2 (in phase) Signal 2 (out of phase)
RCA connection
Drawing and table indicate the pin assignment of an RCA plug.
1
Signal
2
Ground, shielding
35 E-400, E-800, E-1200, E-1500
Power Amplifier
Cleaning
8 Cleaning
Fan grids
The fan grids of the device must be cleaned of any contamination, such as dust, etc. on a reg- ular basis. Before cleaning, switch off the device and disconnect mains-operated devices from the mains. Only use pH-neutral, solvent-free and non-abrasive cleaning agents. Clean the unit with a slightly damp lint-free cloth.
36 E-400, E-800, E-1200, E-1500 Power Amplifier
Protecting the environment
9 Protecting the environment
Disposal of the packing material
Environmentally friendly materials have been chosen for the packaging. These
materials can be sent for normal recycling. Ensure that plastic bags,
packaging, etc. are disposed of in the proper manner.
Do not dispose of these materials with your normal household waste, but make
sure that they are collected for recycling. Please follow the instructions and
markings on the packaging.
Observe the disposal note regarding documentation in France.
37 E-400, E-800, E-1200, E-1500
Power Amplifier
Protecting the environment
Disposal of your old device
This product is subject to the European Waste Electrical and Electronic
Equipment Directive (WEEE) as amended.
Do not dispose of your old device with your normal household waste; instead,
deliver it for controlled disposal by an approved waste disposal firm or
through your local waste facility. If in doubt, consult your local waste
management facility. You can also return the device to a retailer if they
offer to take the device back for free or if they are legally obliged to do
so. When disposing of the device, comply with the rules and regulations that
apply in your country. You can also return your old device to Thomann GmbH at
no charge. Check the current conditions on www.thomann.de.
Proper disposal protects the environment as well as the health of your fellow
human beings. This is because the proper handling of old devices negates the
potential negative effects of hazardous substances, and because it conserves
resources by recycling them.
Also note that waste avoidance is a valuable contribution to environmental
protection. Repairing a device or passing it on to another user is an
ecologically valuable alternative to disposal.
If your old device contains personal data, delete those data before disposing
of it.
38 E-400, E-800, E-1200, E-1500 Power Amplifier
Musikhaus Thomann · Hans-Thomann-Straße 1 · 96138 Burgebrach · Germany · www.thomann.de
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>