ZUBR D2-32 Overvoltage Protection For Professional Instruction Manual
- June 30, 2024
- ZUBR
Table of Contents
- ZUBR D2-32 Overvoltage Protection For Professionals
- Technical data sheet, installation and operation manual
- INSTALLATION
- TECHNICAL DATA
- CONNECTION SCHEMES
- WARRANTY TERMS
- EXPLOITATION
- POSSIBLE PROBLEMS, CAUSES, AND WAYS TO OVERCOME THEM
- SAFETY INSTRUCTIONS
- ADDITIONAL INFORMATION
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ZUBR D2-32 Overvoltage Protection For Professionals
Technical data sheet, installation and operation manual
Voltage monitoring relay ZUBR D2 (hereinafter referred to as the device) designed to protect electrical equipment from high and low voltage and from zero break. In case of voltage deviations, ZUBR D2 turns off the load, and in case of normalization it turns it back on. Equipment that is easily affected to line voltage deviations: refrigerators, TVs, video and audio equipment, computers, etc. All settings are stored in non-volatile memory.
IN THE BOX
- Voltage monitoring relay1 piece
- Technical data sheet, installation and operation manual, warranty card1 piece
- The packing box1 piece
INSTALLATION
Important. Before the installation and operation of the device, please read this document to the end. This will help to avoid possible danger, mistakes and misunderstandings.
The appliance is intended for installation inside residences. The risk of moisture or humidity in the installation site should be minimal. The ambient temperature during the installation should be within -5 … +45 °C.
The appliance is installed in a special box, which allows to conduct an easy
installation and operation. Cabinet should be equipped with standard mounting
rail 35 mm width (DIN rail). The appliance takes of two standard module on 18
mm in width. The height of the appliance should be in the range 0,5 … 1,7 m
from the floor.
It’s important to set the automatic circuit-breaker (QF) in front of the
appliance in order to protect against short circuit and excess capacity in
circuit load. The automatic switch off is established in the open-phase fault
wire, as it is shown at the Scheme 1. Safety shutdown device is set to protect
a person from electric shock leak.
Terminals of the device are designed for wire cross section 2 up to 16 mm. It
is advisable to use a soft wire, which is tightened in the terminals with a
screwdriver with a tip width of no more than 6 mm with a torque of 2,4 N•m. A
screwdriver with a blade more than 6 mm wide can cause mechanical damage to
the terminals. Doing so will void your warranty claim.
TECHNICAL DATA
CONNECTION SCHEMES
The power supply voltage (100-420 V, 50 Hz) is applied to terminals 1 and 3,
with phase (L) connected to terminal 1 and neutral (N) to terminal 3.
The load connection wires are connected to terminal 2 and to the neutral
terminal block (not supplied).
Table 1. Load shutdown time when the voltage goes beyond the limits
WARRANTY TERMS
The warranty for ZUBR devices is valid for 60 months from the date of sale,
provided that the instructions are followed. The warranty period for products
without a warranty certificate is counted from the date of production.
If your device is not working properly, we recommend you to read the section
«Possible problems» firstly.
If you can not find an answer, contact Service Center. In most cases, these
actions resolve all issues. If you continue to have issues with the device,
please send it to a Service Center or to the store where you purchased the
device. If your device is defective due to our fault, we will repair or
replace it under warranty terms within 14 business days.
Please look through the full text of the warranty and the data you need to send to your Service Center on the website https://www.ds- electronics.company. If you have a warranty case, please, contact the General distributor in your area.
ERVICE CENTER CONTACT: +38 (091) 481-91-81 Viber WhatsApp Telegram support@dse.com.ua
EXPLOITATION
The device will immediately begin to display the voltage on phase. If the voltage is normal, the voltage will be applied to the load after the set time and the green indicator will light up.
Setting voltage limits
(factory setting 242 V / 198 V)
To see the upper limit press «+» button, lower limit press «-» button. To
change use «+» and «-» buttons.
IMPORTANT. During voltage limits settings use technical documentation for
protected equipment.
Menu
Use the «=» button to navigate through the menu. Use the «+» and «-» buttons
to change the parameters. After first pressing parameter will flash, after
second pressing it will change. After 10 sec after pressing – display returns
to the mains voltage.
To browse the abbreviation expansion of parameters, use the «i» button.
Alarm log for 100 values
The device stores in non-volatile memory the voltage values at which the load
was interrupted or overheat triggering «oht» (scan QR code for more details).
To view the alarms press «i». Log entries are displayed in order from the last
to the oldest ( «n 0» is the last entry, «n99» is the oldest). Hold down «i»
to browse through the log quickly. To browse up or down, use «+» or«-».
The value of each alarm is accompanied by a single flash of display with its number, where «n 0» – is the newest and «n99» -is the oldest.
To reset the log, wait until the device returns to the mains voltage display. Then hold down the «i» button for 3 sec until «rSt» appears. After releasing the button, the log will be cleared.
Button lock
Hold down the «+» and «-» for more than 6 sec until the message «Loc»/«unLoc»
appears on the screen.
View the temperature inside the case. If
overheating has occurred and «oht» is displayed, press the «i». If there is no
overheating, hold «i» for 24 seconds.
View the firmware version. Hold «i» for 6 seconds.
A tripping counter. Hold «i» for 12 sec. Viewing only.
Reset to factory settings
Hold «-» and «=» buttons simultaneously until the «dEF» message appears on the screen. When you release the button, the settings are reset and the device reboots.
POSSIBLE PROBLEMS, CAUSES, AND WAYS TO OVERCOME THEM
- At turning on neither the indicator nor the screen don’t light up Possible cause: there is no power supply voltage.
- It is necessary to: ensure supply voltage presence.
- Screen normal voltage level, load is not turning on Possible cause: the current voltage in the network is close to the established limits and not stable.
It is necessary to: check the values of the limits; and increase their values so that the protected equipment is tolerated to them. In other cases, please, address to a service centre.
The load is disabled, «oht» flashes on the screen
The temperature inside the enclosure is above 80 °C and the Overheat Protection has tripped.
It is necessary to: check the tightness of the power wires in the device
terminals; make sure that the power to be switched does not exceed the
permissible load and that the connection cross-section of the wires is
correct.
If the protection trips more than 5 times a day, the relay will lock and «oht»
will be displayed permanently. Eliminate the overheating problem and wait
until the temperature inside the relay drops below 60 °C – the relay will
indicate this by displaying a dot at the end of «oht.» Then, to unlock, press
any button on the relay.
The load is disabled, the screen displays «rEP»
The relay was locked to draw attention to the dangerous situation and protect
the equipment.
Cause: the maximum number of frequent operations in case of unstable network
has been exceeded.
Required: unlock the relay by pressing any button, then press «i» to find out
the cause of tripping in the Alarm log. Take steps to correct the problem, if
possible. Note that the relay will unlock automatically 1 hour after the «rEP»
is triggered, this measure will keep your equipment partially operational
until the network problem is corrected.
Every 5 sec the screen displays «Ert»
Possible cause: open or short circuit of the internal overheating sensor. Control over inner overheating will not be done. It is necessary to: send the device to the Service Center.
More information
Please note that your device only has the functions described in these
instructions.
SAFETY INSTRUCTIONS
- Carefully read and become aware of these instructions.
- Connection of the device must be done by a qualified electrician.
- Before the installation (dismantling) and connection (disconnection) of the device, turn off voltage supply and also act according to the «Rules of an arrangement of electric installations».
- Turning on and off, configure the device should be with dry hands.
- Do not connect the device to the network disassembled. Avoid hitting of water or moisture to the device.
- Do not expose the device to extreme temperatures (higher than 40 °C or below -5 °C) and high humidity.
- Never clean the device with the use of chemicals such as benzene, solvents.
- Do not store the device and do not use it in areas with the dust.
- Do not attempt to disassemble and repair the device.
- Do not exceed the landmarks value adaptor and power.
- To protect against overvoltage caused by lightning discharges, use a lightning protector.
Protect the children from games with the working device, it is dangerous.
ADDITIONAL INFORMATION
- Do not fire and do not throw away the device with the household waste.
- After the end of its service life, the product must be disposed of in accordance with applicable law.
- Transportation of goods carried in the package ensures the safety of the product.
- The device can be transported by any kind of transport (rail, sea, motor, air transportation).
- Date of manufacture is on the back side of device. Application time is unlimited.
- The device does not contain harmful substances.
- If you have any questions or something is not clear, call the Service centre, the telephone number is listed below.
d2.1.3G.33.4_2404
EMC Directive 2014/30/EU
Low Voltage Directive 2014/35/EU
Manufacturer and vendor: DS ELECTRONICS, LTD
Ukraine, 04136, Kyiv region, Kyiv, 1-3 Pivnichno-Syretska sir. Sales
Department: +38 (091) 481-91-81,
support@dse.com.ua www.ds-
electronics.company