ZUBR MF2-40 Red Overvoltage Protection For Professionals Instruction Manual

June 1, 2024
ZUBR

ZUBR MF2-40 Red Overvoltage Protection For Professionals

ZUBR-MF2-40-Red-Overvoltage-Protection-For-Professionals-product-
image

Technical data sheet, installation and operation manual
MF2-40, MF2-50, MF2-63
MF2-40 red, MF2-50 red, MF2-63 red
Overvoltage protection for professionals
The multifunction relay ZUBR MF2 (hereinafter referred to as the device) is intended to protect single­ phase electrical equipment from deviation from the set limits for voltage, current or power with the ability to view the power factor in electric grids (cos q>).

IN THE BOX

  • Multifunction relay 1 piece
  • Technical data sheet, installation and operation manual, warranty card 1 piece
  • The packing box 1 piece

TECHNICAL DATA

Model MF2-40 MF2-50 MF2-63
Rated load current (max for 10 minutes) for category AC-1 40 A

(max 50 A)

| 50 A

(max 60 A)

| 63A

(max 80 A)

Rated powerfor category AC-1| 8 800 VA| 11 000 VA| 13 900 VA
Basic current limit| 0,1-40A| 0,1-50A| 0,1-63A
Power limitation| 0,1-8,8 kVA| 0,1-11 kVA| 0,1-13,9 kVA
Current measurement accuracy| 0,5-63 A
± 0,1-0,3 A
Voltage limit| upper 220-280 V, lower 120-210 V
Break-time at increasing| not more than 0,03 sec
Break-time at lower| >120V 0,1-10sec
< 120 V not more than 0,03 sec
Overcurrent or overpower shutdown time| 0-240 sec
Power Volt| not less than 100 V, not more than 420 V
Power consumption| not more than 0,35 kWl’h / month
The number of operating cycles under load| not less 10 000 cycles
The number of operating cycles without load| not less 500 000 cycles
Relay type| polarized
Connection| not more than 16 mm’
Device weight| 0,19 kg ±10 %
Overall dimensions
(w x h x d)| 36 x 85 x 66 mm
IP to GOST 14254| IP20

CONNECTION SCHEMES

  • The supply voltage (100–420 V, 50 Hz), in which the current or power is measured, is supplied to the terminals 1 {phase, L) and 2 ( neutral, N). If a circuit without a neutral bypass through MF2 is used, the neutral wire can also be connected to terminal 4.

  • The connecting wires of the load phases are connected to the corresponding terminals 3, 4 (phase (L) is connected to terminal location 3, and zero (N) is connected to terminal location 4).

  • Scheme 1. Option of wiring diagram with a neutral bypass through MF2-50 red

  • Scheme 2. Option of the connection diagram with a neutral bypass through MF2-50 red

  • Before the installation and operation of the device, PLEASE READ BY THE END OF THIS DOCUMENT.

  • This will help to avoid possible danger, mistakes and misunderstandings.

  • CURRENT AND POWER IS MEASURED at the phase input of the device.

  • All settings are stored in NON-VOLATILE MEMORY

  • Scheme 3. Option of wiring diagram without a neutral bypass through MF2-50 red

  • Scheme 4. Option of the connection diagram without a neutral bypass through MF2-50 red

INSTALLATION

  • The appliance is intended for installation inside residences The risk of moisture or humidity in the installation site should be minimal.The ambient temperature during the installation should be within -5 … +45 ‘C.
  • The appliance is installed in a special box, which allows to conduct the easy installation and operation. Cabinet should beequipped with standard mounting rail 35 mm width (DIN rail). The appliance takes in width of two standard module on 18 mm. The height of the appliance should be in the range 0,5 … 1,7 m from the floor.
  • The device is installed after the protective circuit breaker (QF), which duplicates the protective function (scheme 1, 3). To protect person from electric shock leak is set afety shutdown device (QD).
  • Terminals of the device designed for wire cross section 2 up to 16 mm2 • It is advisable to use a soft wire, which is tightened in the terminals with a screwdriver with a tip width of no more than 6 mm with a torque of 2,4 N·m.
  • A screwdriver with a blade more than 6 mm wide can cause mechanical damage to the terminals. Doing so will void your warranty claim.

WARRANTY TERMS

  • The warranty for ZUBR devices is valid for 60 months from the date of sale, provided that the instructions are followed. The warranty period for products without a warranty certificate is counted from the date of production.
  • If your device is not working properly, we recommend that you first read the section «Possible problems». If you cannot find an answer, contact Service Center. In most cases, these actions resolve all issues.
  • If you continue to have issues with the device, please send it to a Service Center or to the store where you purchased the device. If your device is defective due to our fault, we will repair or replace it under warranty within 14 business days.
  • Please see the full text of the warranty and the data you need to send to your Service Center on the website https://www.ds-electronics.company. If you have a warranty case, please, contact the General distributor in your area.

SERVICE CENTER CONTACT
+38 (091) 481-91-81
Viber WhatsApp Telegram
support@dse.com.ua

WARRANTY CARDZUBR-MF2-40-Red-Overvoltage-Protection-For-Professionals-
fig- \(7\)

EXPLOITATION

  • If the voltage is within acceptable limits, after the set delay time, the load is turned on and the green indicator starts to glow.
  • When switched on, the device first displays the parameter symbols, then the parameters themselves.
  • In case of an emergency, the alert type and its meaning will flash on the screen.
  • Use the « » button to navigate through the menu (table 1 ). To change the parameter, press «+» once, the flashing value of the parameter can be changed with «+» and«-». 5 seconds after pressing return to the settings menu, after other 5 seconds to the indication of line parameters.

Setting voltage tipping point
(factory setting 242 V / 198 V)

  • To view the upper limit, press the «+», button, to view the lower limit, press the«-» button. Then use the «+» and «-» buttons to change the limit as necessary.
  • WHEN SETTING THE VOLTAGE LIMITS USE THE PROTECTED EQUIPMENT TECHNICAL DOCUMENTATION

Delay in the load starting after a failure
(factory setting 3 sec)

  • Following the end of an emergency, the device does not immediately load the connected equipment, but after a set turn-on delay time.
  • After a power surge, the device will display the type of failure, then the current line voltage and start the countdown. If the delay time is set to less than 6 seconds, the device will skip this step.
  • In case of a long failure, the device will display the type of failure and its meaning, and the countdown will start when voltage stabilizes.

Viewing of temperature of a thermal protection sensor

  • It is required to control heating inside the case.
  • For example, to assess the degree of heating inside the case or to prevent overheating. To view hold the button « » for 20 sec.

Log for 100 accidents

  • The device stores in non-volatile memory the last 100 values of voltage, current, power or thermal protection operation «oht», where «n 0» is the last entry, «n99» is the oldest).
  • To enter the log, hold «i» for 3 seconds, the device will display the number of alarm entries in the log. After release, details of the last alarm (number, type and value) are shown.
  • To view the log press the «+» or«-» buttons.
  • To reset the log while viewing it, hold down «+» and «-» simultaneously until «Err rSt» appears. After releasing the buttons, the log will be cleared.

Examples of emergency log entries:ZUBR-MF2-40-Red-Overvoltage-
Protection-For-Professionals-fig- \(15\)

  • View all measured parameters
    Hold «i» for 6 seconds to start viewing. The upper screen will display the parameter, while the middle screen will display its value. Use «+» and «-» to switch between parameters. To quickly exit the view, press «+» and «-» simultaneously. 30 seconds after entering the view mode, the device will return to displaying the measured parameters.ZUBR-MF2-40-Red-Overvoltage-
Protection-For-Professionals-fig- \(16\)

  • Locking the controls
    To lock (unlock), hold down the «+» and «-» buttons for more than 6 seconds until the message «Loe» («unloc») appears on the screen.

  • Viewing of firmware version
    Hold the button «i» for 9 sec. The version will be displayed as running letters. The manufacturer reserves the right to modify the firmware to enhance the device technical characteristics.

  • A tripping counter
    To view hold the button «i» for 15 sec. It is used to estimate the number of switching’s of the power relay and its wear.

  • Reset to factory settings
    Hold the button « » for 30 seconds till the «dEF» sign appears on the screen. After releasing the buttons the device will restart and reset the settings to the factory settings.

Table 1. Settings

ZUBR-MF2-40-Red-Overvoltage-Protection-For-Professionals-fig-
\(18\) ZUBR-MF2-40-Red-
Overvoltage-Protection-For-Professionals-fig- \(19\) ZUBR-MF2-40-Red-Overvoltage-Protection-For-
Professionals-fig- \(20\) ZUBR-
MF2-40-Red-Overvoltage-Protection-For-Professionals-fig-
\(21\) Scheme 5. Relationship of current limits with the tripping time for such limits

continuation of Table 1. Setting the additional current limits ZUBR-MF2-40
-Red-Overvoltage-Protection-For-Professionals-fig-
\(22\)

Table 2.
Models shutdown exit time voltage beyond

Table 2.

| | |
The usual default Pro   oFF| Upper limit| 220-280 V| 0,04 sec
Lower limit| 120-210 V| 0,1…10 sec
< 120V| 0,04 sec
Professional pro on| Upper limit| > 264 V| 0,04 sec
220-264 V| 0,5 sec
Lower limit| 176-210 V| 10 sec
154-176 V| 0,1 ..10 sec
< 154 V| 0,04 sec

ADDITIONAL INFORMATION

  • Do not fire and do not throw away the device with the household waste.
  • After the end of its service life, the product must be disposed of in accordance with applicable law.
  • Transportation of goods carried in the package, ensuring the safety of the product.
  • The deive is transported by any kind of transport (rail, sea, motor, air transportation).
  • Date of manufacture is on the back side of device. Application time is unlimited.
  • The device does not contain harmful substances.
  • If you have any questions or you something will not clear, call the Service centre the telephone number listed below.

POSSIBLE PROBLEMS, CAUSES AND WAYS TO OVERCOME THEM

  • Frequent load trip
    Possible cause: underestimated (overestimated) value of the upper (lower) limit. Exceeding the set current limits or selected power.
    It is necessary to: check which line parameter is triggered, and set the limits of this parameter so that the protected equipment is tolerant of such values.

  • After turning on on the screen normal voltage level, but load is not turning on
    Possible cause: the current voltage in the network is close to the established limits and not stable.
    It is necessary to: check the values of the limits; increase their values so that the protected equipment is tolerated to them. In other cases, please, address to a service centre.

  • At turning on neither indicator nor screen do not shine
    Possible cause: There is no power supply voltage.
    It is necessary to: Ensure supply voltage presence.

  • The load is disabled, «oht» flashes on the screen

    • The temperature inside the housing exceeded 80 °C and triggered protection against internal overheating. «oht» and the temperature of the thermal protection sensor flash 1 time/sec on the screen.
    • Possible cause: inner overheating of the device to which can lead: bad contact in the terminals of the device, high ambient temperature or incorrectly selected cross-section of wires for connecting.
    • It is necessary to: check the tightness of the power wires in the terminals of the device and make sure that the cross section of the wires for connection is selected correctly.
  • Feature of protection against internal overheating:
    the device will resume operation if the temperature inside the housing drops below 60 ‘C. If the protection is triggered more than 5 times within 24 hours, the device will lock
    (then «oht» is displayed permanently, and the bottom two screens will keep flashing), until the temperature inside the housing drops below 50 ‘C (the display will not flash) and one of the buttons is pressed.

  • The load is disabled, the screen displays «rEP Err»

    • Possible cause: the maximum number of consecutive trips for exceeding current, power or voltage limits has been exceeded.
    • It is necessary to: check the cause of the operation according to the alarm log. Make sure that the protection operation settings are correct (see Table 1 «rEP» ).
    • If necessary, change the protection settings, if this does not conflict with the capabilities of the connected load. Unlock the relay by pressing any button.
  • Every 5 sec the screen displays «Ert»

    • Possible cause: open or short circuit of the internal overheating sensor. Control over inner overheating will not be done.
    • It is necessary to: Send the device to the Service Center. Otherwise, control over inner overheating will not be done.

If you don’t find the answer to your question

Please contact our technical support engineer via telegram bot
@dselectronics bot

SAFETY INSTRUCTIONS

  • Carefully read and become aware of yourself these instructions.
  • Connection of the device must be done by a qualified electrician.
  • Before the installation (dismantling) and connection (disconnection) of the device, turn off voltage supply and also act according to the «Rules of an arrangement of electric installations».
  • Turning on and off or and configure the device should be with dry hands.
  • Do not connect the device to the network disassembled.
  • Avoid hitting of water or moisture to the device.
  • Do not expose the device to extreme temperatures (higher than 40°C or below -5°C) and high humidity.
  • Never clean the device with the use of chemicals such as benzene, solvents.
  • Do not store the device and do not use it in areas with the dust.
  • Do not attempt to disassemble and repair the device.
  • Do not exceed the landmarks value adaptor and power.
  • To protect against overvoltage caused by lightning discharges, use a lightning protector.
  • Protect the children from games with the working device, ii is dangerous.

Low Voltage Directive 2014/35/EU

  • EMC Directive 2014/30/EU
  • Manufacturer and vendor: DS ELECTRONICS, LTD
  • 04136, Ukraine, Kyiv region, Kyiv, 1-3 Pivnichno-Syretska sir.
  • +38 (091) 481-91-81,
  • Service Center: +38 (091) 481-91-81
  • support@dse.com.ua
  • www.ds-electronics.company

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals