care ai PSK0203 Ambient Monitoring Sensor User Manual
- June 28, 2024
- care ai
Table of Contents
- PSK0203 Ambient Monitoring Sensor
- Specifications:
- Product Usage Instructions:
- Power On and Camera Activation:
- Light Adjustment:
- Functionality Overview:
- Power Management:
- 1. What is the purpose of the Type-C interface?
- 2. How can I reset the device?
- 3. How do I know the status of the device based on the
PSK0203 Ambient Monitoring Sensor
“`html
Specifications:
- Camera
- LED: 18 beads
- Light Sensor
- IR Receiver
- Indicator: LED status light
- LAN: RJ45 network cable interface
- RST: Reset button
- USB interface
- TYPE-C interface
- HDMI IN
- HDMI OUT
- IR transmitter
- DC IN
Product Usage Instructions:
Power On and Camera Activation:
1. Connect the power supply to the device.
2. The camera will automatically turn on and start video
recording based on your actions.
Light Adjustment:
1. The device has 18 LED beads that illuminate in dark
environments.
2. The light sensor adjusts the lens brightness according to the
surrounding light conditions.
Functionality Overview:
1. Use the LAN port for network connectivity.
2. The reset button can be used for resetting the device.
3. The USB interface allows for connecting external peripherals
like a mouse or keyboard.
4. HDMI ports enable input and output of video data.
5. The IR transmitter sends relevant signals.
Power Management:
1. Use the ON/OFF interface for powering on and shutting down
the device, while DC maintains power supply.
2. Connect the DC interface to power the machine.
Frequently Asked Questions (FAQ):
1. What is the purpose of the Type-C interface?
The Type-C interface is used for manufacturers and engineers to
upgrade the device firmware and is not intended for consumer
use.
2. How can I reset the device?
To reset the device, use a long needle object to press and hold
the reset button for more than 5 seconds.
3. How do I know the status of the device based on the
indicator light?
The LED indicator light flashes blue during normal boot-up and
red during quality inspection.
“`
Ambient Monitoring Sensor
1
2
1 Camera 2 LED 3 Light Sensor 4 IR Receivere 5 Indicator
3
45
6
7
8
9
10 11 12
13 14
6 LAN 7 RST 8 USB
11 HDMI IN 12 IR 13 DC IN
9 TYPE-C
14 ON/OFF
10 HDMI OUT
1
1 After the power supply is powered on,
the camera will automatically turn on and conduct video admission according to
your further operations.
2 18 LED beads to fill the
light, and automatically open the light when the environment reaches the dark
state.
3 The light sensor hole will
automatically adjust the brightness of the lens according to the use
environment.
4 infrared wireless reception
stage, receive the new number issued from the hole 12 position.
5 Machine LED status
indicator light,the light flashing, blue indicates the normal boot,red
indicates in the quality inspection.
2
6 RJ 45 network cable
interface, external local
network, connected to
the network cable network.
7 Reset button, using a long
needle object, long press the machine for more than 5 seconds to reset
9 Type-C interface, which is
used for manufacturers and engineers to upgrade the brush machines, and is not
recommended for consumers.
10 HDMI OUT, external HDMI wire, understand other display can be camera video
source playback.
8 USB interface, can be
external mouse, keyboard, etc.
3
11 HDMI IN, external HDMI wire, can input other external video data to the camera.
12 IR transmitter, the relevant signal sent by the use.
14 ON / OFF interface, switch on and shutdown while DC keeps power supply.
13 DC interface, connect to the DC interface, to supply the power to the
machine.
41
FCC Warning This device complies with part 15 of the FCC rules. Operation is
subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any inte rference received,
including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interferenceto radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures: · Reorient or relocate the receiving antenna. ·
Increase the separation between the equipment and receiver. · Connect the
equipment into an outlet on a circuit different from that to which the
receiver is connected. · Consult the dealer or an experienced radio/TV
technician for help.
Radiation Exposure Statement This equipment complies with FCC radiation
exposure limits set forth for an uncontrolled environment. This equipment
should be installed and operated with minimum distance 20cm between the
radiator and your body.