Specifications

  • Output: 8A.58.9.024.1600 8 NO (SPST) – EMR 6 A, 250 V AC1; 8A.88.9.024.1600 8 NO (SPST) SSR 2 A, 24 V DC1
  • Input: 16 digital/analog (0 to 10 V)
  • Auxiliary port supports up to 5 expansion modules
  • Mounting: EN 60715 rail mounting
  • Environmental Conditions: Extended – Humidity 5-95 RH%, Altitude 2000 m, IP20
  • Torque: 0.8 Nm
  • Wire Size: (1×6/2×4) mm2 (1×10/2×12) AWG, (1×4/2×2.5) mm2 (1×12/2×14) AWG

Features

  • 16 digital / analog (0…10 V) INPUT
  • Auxiliary port, MAX 5 expansion modules
  • Open type, EN 60715 rail mounting
  • Environmental Conditions: Extended Humidity 5-95 RH%
  • Altitude 2000 m
  • IP20

Connections

Torque: 0.8 Nm

Wire Size:

  • (1×6/2×4) mm2 (1×10/2×12) AWG
  • (1×4/2×2.5) mm2 (1×12/2×14) AWG

Compliance

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Product Usage Instructions

Mounting Instructions:

  1. Ensure the mounting surface is compatible with EN 60715 rail mounting.
  2. Securely mount the unit on the rail using appropriate fasteners.

Wiring Instructions:

  1. Connect the input wires according to the specified wire size.
  2. Connect the output wires to the designated terminals based on the load requirements.

Expansion Modules Installation:

  1. If using expansion modules, carefully attach them to the auxiliary port of the main unit.
  2. Ensure proper alignment and secure connection between the main unit and expansion modules.

Powering On:

  1. After installation, apply power to the unit within the specified voltage range.
  2. Check for proper functioning of both input and output signals.

FAQs

What is the maximum humidity level this product can withstand?

The product can operate within a humidity range of 5% to 95% RH.

Can I use this product at high altitudes?

Yes, this product is designed to function at altitudes up to 2000 meters.

What is the maximum current for the 8A.58.9.024.1600 model?

The maximum current is 6 A at 250 V AC1.

What is the maximum current for the 8A.88.9.024.1600 model?

The maximum current is 2 A at 24 V DC1.

How many expansion modules can be connected?

A maximum of 5 expansion modules can be connected.

What is the environmental humidity range for this device?

The device can operate in humidity conditions ranging from 5% to 95% RH.

What is the altitude limit for the operation of this device?

The device can operate at altitudes up to 2000 meters.

What is the IP rating of the device?

The device has an IP20 rating.