ADA TemPro 550 Infrared Thermometer Instruction Manual
- June 28, 2024
- ADA
Table of Contents
- ADA TemPro 550 Infrared Thermometer
- Product Usage Instructions
- Frequently Asked Questions
- Review
- Measurement considerations
- Complete set
- Technical data
- Safety requirements
- DESCRIPTION OF THE INSTRUMENT
- Operation
- Maintenance
- Specific reasons for instrument malfunctions
- Storage and transportation
- WARRANTY
- Appendix 1
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ADA TemPro 550 Infrared Thermometer
Specifications
- IR temperature range: Not specified
- Optical resolution, D:S: Not specified
- Resolution: Not specified
- Accuracy: Not specified
- Response time: Not specified
- Spectral response, um: Not specified
- Emissivity: Not specified
- Backlight: Available
- Data hold: Available
Product Usage Instructions
Overview
The TemPro 550 is an IR Thermometer designed for non-contact temperature measurements at the touch of a button. It features a built-in laser pointer for increased target accuracy, a backlight LCD, and convenient push buttons for ergonomic operation.
Measurement Foundation
The TemPro 550 can be used to measure the temperature of objects’ surfaces that are unsuitable for traditional contact thermometers, such as moving objects, surfaces with electrical currents, or objects that are difficult to touch.
Complete Set Contents
- Thermometer TemPro 550
- Battery 9V
- Plastic blister
- Operating manual
Technical Data
The functions of the TemPro 550 are not specified in the provided text.
Specifications
- IR temperature range: Not specified
- Optical resolution, D:S: Not specified
- Resolution: Not specified
- Accuracy: Not specified
- Response time: Not specified
- Spectral response, um: Not specified
- Emissivity: Not specified
- Backlight: Available
- Data hold: Available
Frequently Asked Questions
Q: How do I change the battery in the TemPro 550?
A: To change the battery in the TemPro 550, follow these steps.
- Locate the battery compartment on the back of the thermometer.
- Remove the cover by sliding it in the direction indicated.
- Replace the old battery with a new 9V battery, ensuring correct polarity.
- Close the battery compartment cover securely.
Q: Can the TemPro 550 measure the temperatures of moving objects accurately?
A: Yes, the TemPro 550 is designed to measure the temperature of moving objects accurately due to its non-contact infrared technology.
Review
- TemPro 550 is an IR Thermometer for non-contact temperature measurements at the touch of a button. The built-in laser pointer increases target accuracy while the backlight LCD and handy push-buttons combine for convenient, ergonomic operation.
- TemPro 550 can be used to measure the temperature of objects’ surfaces that is improper to be measured by a traditional (contact) thermometer (such as moving objects, the surface with electricity current, or objects that are uneasy to be touched).
Measurement considerations
- Holding the meter by its handle, point the IR Sensor toward the object whose temperature is to be measured. The meter automatically compensates for temperature deviations from ambient temperature.
- Infrared thermometers measure the surface temperature of an object. The unit’s optics sense emitted, reflected, and transmitted energy, which is collected and focused onto the detector.
- The unit’s electronics translate the information into a temperature reading, which is displayed on the unit. The laser is used for aiming purposes only.
Complete set
- Thermometer TemPro 550 Battery 9V
- Plastic blister
- Operating manual
Technical data
Functions
- Rapid detection function
- Precise non-contact measurements
- Built-in laser sighting
- Unique flat surface, modern housing design Automatic Data Hold
- Backlight LCD
- Low battery indicator
Specifications
IR temperature range | -50°С to +550°С |
---|---|
Optical resolution, D:S | 12:1 |
Resolution | 0.1°С |
Accuracy | ±1,5°С at 0<t≤550°С ±3°С at t≤0°С |
Response time | 0.5 sec. |
--- | --- |
Spectral response, um | 8 ~ 14 |
Emissivity | 0.95 |
Backlight | yes |
Data hold | yes |
Working temperature/relative humidity | 0..40°С / 10-95% at 30°С |
--- | --- |
Power supply | 9V (krona) |
Dimensions, mm | 175x100x49 |
Weight, gr | 130 |
Safety requirements
- Inaccurate readings will result from measuring shiny or polished metal surfaces (stainless steel, aluminum, etc.). To compensate, cover the measuring surface with masking tape or flat black paint.
- Allow time for the tape to reach the same temperature as the material under it. Measure the temperature of the tape or painted surface.
- The unit cannot be measured through transparent surfaces such as glass. It will measure the surface temperature of the glass instead.
- Steam, dust, smoke, etc., can prevent accurate measurement by obstructing the unit’s optics.
- Make sure that the target is larger than the unit’s spot size. The smaller the target, the closer you should be to it. When accuracy is critical, make sure the target is at least twice as large as the spot size.
DESCRIPTION OF THE INSTRUMENT
Features (Pic.2)
- Laser pointer
- IR sensor
- LCD display
- MEASUREMENT trigger
- Battery compartment
- °C/°F button
- Laser pointer On/Off button
- Backlight On/Off button
LCD display (Pic.3)
- A – Data hold icon (HOLD)
- B – Scanning icon (SCAN)
- C – Laser “ON” icon
- D – Backlight ON icon
- E – Low power symbol
- F – °C/°F symbol
- G – Current temperature value
Operation
Preparation before operation
- Read the operating manual before using the instrument.
- Take the instrument out of the case.
- Open the battery cover and put 9V battery.
Thermometer On/Off
- Pull and hold the trigger (4) to turn the meter on and begin testing. The display will light if the battery is good. Replace the battery if the display does not light.
- The meter will automatically power down after approximately 20 seconds after the trigger is released.
°C/°F
- To choose the measuring unit press button (6).
EMS adjustment
- The emissivity (EMS) – 0.95. To obtain more accurate values see appendix 1.
Laser pointer
- The laser pointer is on when you turn on the unit. To turn off the laser pointer, press button (7) LASER.
Backlight
- The backlight is on when you turn on the unit. To turn off the backlight, press button (8) BACKLIT.
Measurement operation
- Hold the meter by its handle grip and point it towards the surface to be measured. Pull and hold the trigger (4) to turn the meter on and begin testing.
- Release the trigger (4) and the HOLD display icon will appear on display indicating that the reading is being held.
Distance to spot size
- When taking measurements, pay attention to the Distance to Spot Size. As the Distance (D) from the target surface increases, the spot size (S) of the area measured by the unit becomes larger. The Distance to Spot size of the unit is 12:1.
- This unit is equipped with a laser, which is used for aiming.
Maintenance
- The maintenance of the thermometer includes the replacement of the power supply, cleaning the unit with a dry cloth, and also debugging. Periodically, one time per year it is necessary to check settings in an authorized service center.
Specific reasons for instrument malfunctions
Malfunction | A possible reason for the malfunction | Way of debugging |
---|
After pressing and holding the button MEASUREMENT (5) the instrument doesn’t turn on.| 1. Fully discharged battery
2. Bad contact between the battery and the jack of the thermometer
3. Broken jack wire in the battery compartment
| Change battery
Recover contacts Recover power lead
Contact with authorized service center if you have other malfunctions.
Storage and transportation
- Storage and transportation of the instrument should be only in case.
- Take out the battery if you are not going to use the instrument for a long time.
- Don’t expose the instrument to mechanical effects (heating, hits, strong vibrations, humidity, dust …).
- Store the instrument in normal conditions (temperature/humidity).
WARRANTY
- This product is warranted by the manufacturer to the original purchaser to be free from defects in material and workmanship under normal use for two (2) years from the date of purchase.
- During the warranty period, and upon proof of purchase, the product will be repaired or replaced (with the same or similar model at the manufacturer’s option), without charge for either part of labor.
In case of a defect please contact the dealer where you originally purchased this product. The warranty will not apply to this product if it has been misused, abused, or altered. Without limiting the foregoing, leakage of the battery, and bending or dropping the unit are presumed to be defects resulting from misuse or abuse.
EXCEPTIONS FROM RESPONSIBILITY
- The user of this product is expected to follow the instructions given in the operators’ manual.
- Although all instruments left our warehouse in perfect condition and adjustment the user is expected to carry out periodic checks of the product’s accuracy and general performance.
- The manufacturer, or its representatives, assumes no responsibility for the results of a faulty or intentional usage or misuse including any direct, indirect, consequential damage, and loss of profits.
- The manufacturer, or its representatives, assumes no responsibility for consequential damage, and loss of profits by any disaster (earthquake, storm, flood …), fire, accident, or an act of a third party and/or usage in other than usual conditions.
- The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits due to a change of data, loss of data interruption of business, etc., caused by using the product or an unusable product.
- The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits caused by usage other than explained in the users’ manual.
- The manufacturer, or its representatives, assumes no responsibility for damage caused by wrong movement or action due to connecting with other products.
WARRANTY CARD
- Name and model of the product ___
- Serial number ____
- date of sale____
- Name of commercial organization _____
stamp of the commercial organization
- The warranty period for the instrument exploitation is 24 months after the date of original retail purchase. It extends to the equipment, imported on the RF territory by the official importer.
- During this warranty period, the owner of the product has the right for free repair of his instrument in case of manufacturing defects.
- Warranty is valid only with the original warranty card, fully and filled (stamp or mark of thr seller is obligatory).
- Technical examination of instruments for fault identification which is under the warranty, is made only in the authorized service center.
- In no event shall the manufacturer be liable before the client for direct or consequential damages, loss of profit, or any other damage that occurs as a result of the instrument outage?
- The product is received in the state of operability, without any visible damages, in full completeness. It is tested in my presence. I have no complaints about the product quality.
- I am familiar with the conditions of the qarranty service and I agree.
- purchaser signature ___
- Before operating you should read service instructions!
WARRANTY DOESN’T EXTEND TO FOLLOWING CASES:
- If the standard or serial product number will be changed, erased, removed, or wil be unreadable.
- Periodic maintenance, repair, or changing parts as a result of their normal runout.
- All adaptations and modifications with the purpose of improvement and expansion of the normal sphere of product application, mentioned in the service instruction, without the tentative written agreement of the expert provider.
- Service by anyone other than an authorized service center.
- Damage to products or parts caused by misuse, including, without limitation, misapplication or negligence of the terms of service instruction.
- Power supply units, chargers, accessories, and wearing parts.
- Products, damaged from mishandling, faulty adjustment, maintenance with low-quality and non-standard materials, presence of any liquids and foreign objects inside the product.
- Acts of God and/or actions of third persons.
- In case of unwarranted repair till the end of the warranty period because of damages during the operation of the product, its transportation, and storing, the warranty doesn’t resume.
Appendix 1
Emissivity table (ЕТ)
Note:
- N – radiation towards в направлении normal.
- Н – radiation in the range of hemisphere.
- Linear interpolation between points is rather accurate.
- Source: reference books.
Certificate of acceptance and sale
- №_____
name and model of the instrument
- Corresponds to __
designation of standard and technical requirements
- Date of issue ___
Stamp of quality control department
- Price
- Sold ___
- Date of sale __
- name of commercial establishment
- Address:WWW.ADAINSTRUMENTS.COM
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>