ALTA LABS AP6-Pro-Outdoor WiFi 6 Ceiling Wall Indoor and Outdoor Access Point User Guide

June 28, 2024
ALTA LABS

ALTA LABS AP6-Pro-Outdoor WiFi 6 Ceiling Wall Indoor and Outdoor Access

Point

Before You Begin
Create your free Alta account to manage your Alta devices. Visit manage.alta.inc or download the Alta Networks app from the Apple App store. (Note: Android app will be available soon)

Package Contents

Note : Metal mounting pole clamps are not included but are recommended for pole mounting.

Installation Requirements

  • Ethernet cabling (CAT 5 or above)
  • 48V PoE+ switch or PoE injector
  • Router
  • Phillips screwdriver
  • Drill and drill bit for wall or ceiling mounting

Hardware Overview

Front

LED Illuminates white by default when AP is online and functional. Can be changed to blue, white, or off in the Alta app or management interface. Flashes when booting.

Back

Reset Button Press down for 10 seconds until the LED begins flashing to reset the AP to factory defaults.
Ethernet Port Connects to an Ethernet cable from your PoE+ Switch. An optional 48V, 0.5A adapter can be purchased and used to power the AP.

Connecting Ethernet

  1. Disassemble the waterproof gland and connect an outdoor-rated CAT 6 Ethernet cable. Reassemble the pieces and seal tight.
  2. Connect the Ethernet cable to surge protection devices (not included) on both ends of the cable.

Note : Be sure to adhere to proper grounding techniques recommended by the surge protection device manufacturer.

Hardware Installation

Note : Installation and maintenance service should only be performed by qualified skilled personnel only.

Pole Mount
Note : Metal mounting pole clamps are not included but are recommended. Clamps should be 1/2″ height to fit into the back of the AP6-Pro-Outdoor.
Insert the two ends of the pole mount clamps or zip ties through the AP, around the pole, and into the other end of the clamps or zip ties. Tighten as needed.

Wall Mount

Mounting On Solid Wood

  1. Secure the Wall Mount to the wall using the Wall-Mount Screws and a Phillips screwdriver. Be sure to use the screws included with the product.
  2. Connect the AP6-Pro-Outdoor to the Wall Mount using the 4 Screws with Washers and a Phillips screwdriver.

Mounting on Dry Wall

  1. Position the Mounting Plate in the desired location and use a pencil to mark the holes.
  2. Use a 6 mm drill bit to drill the holes for the anchors.
  3. Insert the anchors into the wall and insert the screws into the anchors using a Phillips screwdriver. Note: Do not tighten the screws until they are flush with the wall. Leave a bit of a gap so the Wall Mount will be able to slide over the screws.
  4. Slide the Wall Mount down into place over the screws.
  5. Connect the AP6-Pro-Outdoor to the Wall Mount using the 4 Screws with Washers and a Phillips screwdriver.

Note : The device is only to be connected to indoor PoE equipment.

Connecting Power

The AP is powered over Ethernet, it can be powered by a PoE+ Switch or using an optional 48V, 0.5A PoE Injector.
Connect your Ethernet cable from your AP6-Pro-Outdoor to your PoE+ Switch (or optional PoE Injector).

Set Up Your Device

Follow the instructions in the Alta app or management interface to set up your AP.

Specifications

Model: AP6-Pro-Outdoor

Dimensions| 210 x 150 x 90 mm

(8.3 x 5.9 x 3.5″)

Weight| 0.9 kg (1.9 lbs)
Enclosure Material| Top Cover: Polycarbonate, Bottom Cover: Milled Aluminum
Wall Mount Material| Galvanized Steel
Weatherproofing| IP68
Network Interface| Ethernet, WiFi, Bluetooth
Management Interface| (1) GbE RJ45 Port
Button(s)| Reset/Factory Reset
LED| Blue, White
Power Method| PoE+

Power Supply

| PoE+ Enabled Network Switch or 48V, 0.5A PoE Adapter (Optional)
Supported Voltage Range| 42.5-57V DC
Max. Power Consumption| 25W Max, 7 – 15W Typical @ 23° C (73° F)
Max. Transmit Power| 2.4 GHz: 23 dBm @2NSS

5 GHz: 26 dBm @4NSS

MIMO

| 5 GHz: 4 x 4, DL/UL MU-MIMO, DL/UL MU-OFDMA

2.4 GHz: 2 x 2. DL/UL MU-OFDMA

Explicit TX beam-forming

Throughput Rate| 2.4 GHz: Up to 573 Mbps

5 GHz: Up to 5.8 Gbps

Mounting| Pole mount, wall mount
Operating Temperature| -40 to 70° C (-40 to 158° F)
Operating Humidity| 5 to 95% Noncondensing
Certifications| CE, FCC, IC

Federal Communication Commission

Interference Statement
This product has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Caution
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.

Non-Modification Statement
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

FCC Radiation Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

CAN ICES-003(B) / NMB-003(B)
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:

(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device.

ISED Radiation Exposure Statement
This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
The transmitter module may not be co-located with any other transmitter or antenna.
The Country Code Selection feature is disabled for products marketed in the US/Canada.
For product available in the USA/Canada market, only channel 1~11 can be operated. Selection of other channels is not possible.

Technical Supporthelp.alta.inc

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ALTA LABS User Manuals

Related Manuals