Altronix NetWaySP4 4 Port Fiber Optic Transceiver for Composite Fiber Powered Cable Installation Guide
- June 27, 2024
- Altronix
Table of Contents
Altronix NetWaySP4 4 Port Fiber Optic Transceiver for Composite Fiber
Powered Cable
Specifications:
- Product Name: NetWaySP4 Fiber Solution
- Type: 4-port Fiber Optic Transceiver for Composite Fiber (Powered) Cable
- Ports: Four (4) 1Gb SFP ports and four (4) ports for up to 120W per port
- Power Supply: UL Listed ITE power supply, PoE+ (30W) or Hi-PoE (60W)
- Fiber Ports: Class 1 laser product compliant
Installation Instructions:
- Attach mounting brackets to unit for rack or wall mount installation.
- Affix rubber pads to unit for shelf installation.
- Secure the unit in a rack or on a wall, or place unit on a shelf as desired.
- Connect Composite (Powered) Fiber cable. Fiber portion connects to SFP port, copper portion connects to power output.
- Connect opposite end of Composite (Powered) Fiber cable. Fiber\ portion connects to SFP port on the switch, copper portion connects to power input.
Recommended Altronix SFP Modules:
- P1MM – For Multi-Mode Fiber up to 550m
- P1SM10 – For Single-Mode Fiber up to 10km
- P1AB2K – For Single Strand Single-Mode Fiber up to 2km
- P1GCE – For CAT5e or better up to 100m
FAQ
- Q: Can NetWaySP4 be used for standard fiber cable applications?
- A: Yes, NetWaySP4 can be used for standard fiber cable applications as well.
- Q: What are the power options for NetWaySP4?
- A: NetWaySP4 supports PoE+ (30W) or Hi-PoE (60W) power\ options.
- Q: What are the recommended Altronix SFP modules for NetWaySP4?
- A: The recommended Altronix SFP modules are P1MM, P1SM10, P1AB2K, and P1GCE for different fiber types and transmission distances.
NetWaySP4 4-port Fiber Optic Transceiver for Composite Fiber (Powered) Cable
Overview
Altronix NetWaySP4 Fiber Optic Transceiver with optional PoE power provides up four (4) 1Gb SFP ports and four (4) ports for up to 120W per port to be transmitted over composite fiber (powered) cable (fiber + copper combined) to NetWay Spectrum PoE+ Hardened Switches. NetWaySP4 can be used for standard fiber cable applications as well.
Specifications
Agency Listings:
- UL/cUL UL 60950-1 (Information Technology Equipment).
- CE European Conformity.
Input:
Options:
- 48-56V: UL Listed ITE power supply i.e. VertiLine563 (2 x 56V / 150W ports).
- PoE+ (30W) or Hi-PoE (60W) (midspan/endspan)
- Four (4) RJ45 inputs up to 60W max. \Power:
- Four (4) Gigabit (1000Mbps) outputs.* (All output power is dependent on input).
- IEEE 802.3af and IEEE 802.3at compliant (PoE/PoE+).
- Short circuit protection.
Environmental:
- Refer to Environmental Conditions
Ethernet:
- Four (4) ports.
- Wire type: 4-pair CAT5e and higher.
- Connectivity: RJ45, auto-crossover.
- Speed: Gigabit (1000Mbps).
- Distance: up to 100m.
Compatible PoE
Hardened Switches and Accessories:
- NetWaySP3WPN: 3-port PoE Hardened Switch with (1) SFP port.
- NetWay4EWPN: 4-port PoE Hardened Switch with (1) SFP port.
- NetWay4E1WPN: 4-port PoE Hardened Switch with (1) SFP port.
- NetWaySP4WPN: 4-port PoE Hardened Switch with (2) SFP ports.
- NetWaySP8WPN: 8-port PoE Hardened Switch with (2) SFP ports.
Fiber Ports:
- Four (4) Gigabit SFP ports.
- Use with SFP module 1000Base-X (1Gb), compliant to Class 1 laser product (not included).
- Outputs are Class 2 Power-Limited: when powered by PoE, PoE+, Hi-PoE unit or UL Listed power-limited supply. If supplied by a non-limited power source, the output of the device must be considered as a non-limited power source. For non-limited power sources, the unit must be installed in restricted access, and the need for additional protective circuitry and/or an appropriate fire enclosure for the products supplied by this device, shall be determined in the installation of the device.
Installation Instructions
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities having jurisdiction. NetWaySP4 is not intended to be connected to outside plant leads. This product is for indoor use only and must be installed within the protected premises.
-
Attach mounting brackets to unit for rack or wall mount installation (Fig. 2 or 4, pg. 5). Affix rubber pads to unit for shelf installation (Fig. 4, pg. 5).
-
Secure the unit in a rack or on a wall, or place unit on a shelf as desired.
Note: The following factors should be taken into consideration when installing these rack mount units:- a. The unit is to be installed in a space where the maximum ambient temperature does not exceed 104ºF (40ºC).
- b. Take care to ensure that there is sufficient air flow around the unit and that obstructions do not impede it.
- c. When mounting units in a rack, take care to avoid uneven loading which can cause a hazardous condition.
-
Input Power Options:
- Connect structured cable from ethernet (midspan or endspan) device to RJ45 jack marked [Ethernet] (Fig. 1, pg. 4).
- Connect 48-56V UL Listed ITE power supply (rated minimum ambient temperature of 50ºC, or the installation of the device must conform to the rated ambient temperature of the power supply) to terminals marked [– In +, 56VDC] (Fig. 1 pg. 4).
-
Daisy-chaining inputs: Connect terminals marked [– Pass +, 56VDC] to the next input terminals marked [– In +, 56VDC] (Fig. 1 pg. 4).
-
Connect Composite (Powered) Fiber cable. Fiber portion connects to port marked [SFP 1-4], copper portion connects to output marked [OUT 56VDC, 1-4] (Fig. 1, pg. 4).
-
Connect opposite end of Composite (Powered) Fiber cable. Fiber portion connects to SFP port on NetWaySP3WPN or NetWay4EWPN, copper portion connects to power input of NetWay Spectrum Hardened Switch, carefully observing correct polarity (Refer to NetWaySP3WPN/4WPN/8WPN / NetWay4EWPN Installation Guides).
Recommended Altronix SFP Modules:
Altronix P1MM, P1SM10, P1AB2K and P1GCE are hot-pluggable SFP fiber transceiver modules and are readily usable with all Altronix Spectrum fiber optic equipment for 1Gb transmission rates.
- P1MM – For use with Multi-Mode Fiber for distances up to 550m.
- P1SM10 – For use with Single-Mode Fiber for distances up to 10km.
- P1AB2K – For use with Single Strand Single-Mode Fiber for distances up to 2km.
- P1GCE – For use with CAT5e or better for distances up to 100m.
Technical Specifications
Parameter | Description |
---|---|
Number of Ports | Four (4) – Gigabit SFP Ports. Four (4) Gigabit (1000Mbps) |
ports.
Power Outputs| Four (4) outputs. All output power is dependent on input.
Input Power Requirements| – 48-56V: UL Listed ITE power supply i.e.
VertiLine563 (2 x 56V / 150W ports).
– PoE+ (30W) or Hi-PoE (60W) (midspan/endspan)
Environmental Conditions
| Operating Ambient Temperature (120W): – 40ºC to 50ºC (– 40ºF to 122ºF) Relative Humidity: 85%, +/– 5%
Storage Temperature: – 40ºC to 85ºC (– 40ºF to 185ºF). Operating Altitude: – 304.8 to 2,000m.
Weights (approx.)| Product: 2.55 lb. (1.16 kg) | Shipping: 4.7 lb. (2.13 kg).
NetWaySP4 Typical Application
Mounting Options
Rack Mount Installation
- Remove and discard factory-installed screws from both sides of rack chassis (Fig. 2a).
- Install mounting brackets (A) on the left and right side of rack chassis using the four (4) flat head screws (B) (included) (Fig. 2b).
- Place unit into desired EIA 19” rack position and secure with mounting screws (not included) (Fig. 2c).
Wall Mount Installation
- Install mounting brackets (A) on the left and right side of rack chassis using four (4) flat head screws (B) (included) (Fig. 3a).
- Place unit at the desired location and secure with #6 size screws or larger (not included) (Fig. 3b).
Caution: It is necessary to make sure mounting screws are securely fastened to a beam when installing the unit vertically.
Shelf Installation
- Position and affix rubber pads (C) (included) at each corner on the bottom of the unit (Fig. 4).
- Place unit in desired location
Mounting Hardware (Included):
NetWay SP4 Rack Mount Chassis
Mechanical Drawing and Dimensions
- The lightning flash with the arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient magnitude to constitute an electric shock.
- The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
- CAUTION: To reduce the risk of electric shock do not open the enclosure. \There are no user-serviceable parts inside. Refer servicing to qualified service personnel.
Altronix is not responsible for any typographical errors.
- 140 58th Street, Brooklyn, New York 11220 USA
- phone: 718-567-8181
- fax: 718-567-9056
- website: www.altronix.com
- e-mail: info@altronix.com
- Lifetime Warranty IINetWaySP4 G28V
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>