wezzer Teo TH70 Noise Monitor Thermohygrometer User Manual
- June 3, 2024
- wezzer
Table of Contents
Levenhuk Wezzer Teo TH70
Noise Monitor Thermohygrometer
User Manual
Teo TH70 Noise Monitor Thermohygrometer
Parts overview and screen interface
1 Power button
2 Left button
3 Right button
4 MENU button
5 Power input
6 Sensor (microphone)| 7 Temperature
8 Humidity
9 Decibel display
10 Sound level indication
11 Positioning sticker
12 Screws
---|---
Levenhuk Wezzer Teo TH70
Noise Monitor Thermohygrometer
Caution! Please remember that mains voltage in most European countries is
220–240V. If you want to use your device in a country with a different mains
voltage standard, remember that use of a converter is absolutely necessary.
Getting started
- Connect the power cable to the device and the DC adapter (not included) via a USB plug and connect to the AC power supply.
- Press (1) to turn the device on.
- Press (4) to choose the measurement time of the sound sampling. There are three modes: fast, medium, and slow. Use the fast mode to measure sudden changes in sound levels, e.g. construction equipment sounds. The slow mode is used to measure sound signals that change slowly, e.g. noise from photocopiers, printers, etc.
- Press (2)/(3) to adjust brightness.
Comfort level indication
| Quiet/comfortable| Noisy| Loud| Extremely loud
---|---|---|---|---
Decibel readings| <60| 60-75| 75-85| >85
Indication| | | |
Temperature| 18… 26°C| <18°C / >26°C
Humidity| 30… 60%| <30%/ >60%
Specifications
Operating humidity range | 20… 85% |
---|---|
Operating temperature range | –10… +50°C (+14… +122°F) |
Screen | color, with an LED backlight |
Power supply | Li-ion battery (2000 mA∙h), DC adapter 5V 1000mA (not included) |
USB cable | 3m, included |
The manufacturer reserves the right to make changes to the product range and specifications without prior notice.
Care and maintenance
Take the necessary precautions when using the device with children or others who have not read or who do not fully understand these instructions. Do not try to disassemble the device on your own for any reason. For repairs and cleaning of any kind, please contact your local specialized service center. Protect the device from sudden impact and excessive mechanical force. Store the device in a dry cool place. Only use accessories and spare parts for this device that comply with the technical specifications. Never attempt to operate a damaged device or a device with damaged electrical parts! If a part of the device or battery is swallowed, seek medical attention immediately. Children should use the device under adult supervision only.
Battery safety instructions
Always purchase the correct size and grade of battery most suitable for the intended use. Always replace the whole set of batteries at one time; taking care not to mix old and new ones, or batteries of different types. Clean the battery contacts and also those of the device prior to battery installation. Make sure the batteries are installed correctly with regard to polarity (+ and –). Remove batteries from equipment that is not to be used for an extended period of time. Remove used batteries promptly. Never short-circuit batteries as this may lead to high temperatures, leakage, or explosion. Never heat batteries in order to revive them. Do not disassemble batteries. Remember to switch off devices after use. Keep batteries out of the reach of children, to avoid risk of ingestion, suffocation, or poisoning. Utilize used batteries as prescribed by your country’s laws.
Levenhuk International Lifetime Warranty
All Levenhuk telescopes, microscopes, binoculars, and other optical products,
except for their accessories, carry a lifetime warranty against defects in
materials and workmanship. A lifetime warranty is a guarantee on the lifetime
of the product on the market. All Levenhuk accessories are warranted to be
free of defects in materials and workmanship for six months from the purchase
date. The warranty entitles you to the free repair or replacement of the
Levenhuk product in any country where a Levenhuk office is located if all the
warranty conditions are met.
For further details, please visit:
www.levenhuk.com/warranty
If warranty problems arise, or if you need assistance in using your product,
contact the local Levenhuk branch.
Levenhuk Inc. (USA): 928 E 124th Ave. Ste D, Tampa, FL 33612,
USA, +1-813-468-3001,
contact_us@levenhuk.com
Levenhuk Optics s.r.o. (Europe): V Chotejně 700/7, 102 00 Prague 102,Czech
Republic, +420 737-004-919, sales-info@levenhuk.cz
Levenhuk®, Wezzer® are registered trademarks of Levenhuk, Inc.
© 2006–2022 Levenhuk, Inc. All rights reserved.
www.levenhuk.com
20221003
References
- Доживотна гаранция на Levenhuk – Официален уебсайт на Levenhuk в България
- Levenhuk’s official website in USA
- Levenhuk Limited Warranty – Levenhuk’s official website in USA
- Doživotní záruka společnosti Levenhuk – Oficiální webové stránky Levenhuk pro Českou republiku
- Levenhuk Lebenslange Garantie – Die offizielle Website von Levenhuk in Deutschland
- Garantía internacional de por vida Levenhuk – Web oficial de Levenhuk en España
- Levenhuk Lifetime Warranty – Levenhuk’s official website in USA
- A Levenhuk élettartamra szóló szavatossága – A Levenhuk hivatalos magyarországi weboldala
- Gwarancja bezterminowa Levenhuk – Oficjalna witryna internetowa Levenhuk w Polsce
- Поддержка - Гарантийное обслуживание Левенгук - Levenhuk Russia
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>