INSTALLATION INSTRUCTIONS
30” and 36”
Stainless Steel Gas Cooktops
Safety Information
Questions? Call Monogram at 800.444.1845 or visit
monogram.com
In Canada call 899.561.3344 or visit monogram.ca
IN THE COMMONWEALTH OF MASSACHUSETTS
- This product must be installed by a licensed plumber or gas fitter.
- When using ball type gas shut-off valves, they shall be the T-handle type.
- A flexible gas connector, when used, must not exceed 5 feet.
WARNING
FIRE OR EXPLOSION HAZARD
If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
Installation must be performed by a qualified installer.
Read these instructions completely and carefully.
Installation of this cooktop must conform with local codes, or in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA.54, latest
edition.
In Canada, installation must conform with the current Natural Gas Installation
Code, CAN/CGA-B149.1 or the current Propane (LP) Installation Code,
CAN/CGA-B149.2, and with local codes where applicable.
This product has been design-certified by UL according to ANSI Z21.1, latest
addition and Canadian Gas Association according to CAN/CGA-1.1 latest
addition.
When installing a gas appliance the use of old flexible connectors can cause
gas leaks and personal injury. Always use a NEW flexible connector.
Leak testing of the appliance shall be conducted according to the manufacturer
instructions.
The cooktop must be electrically grounded in accordance with local codes or,
in the absence of local codes, in accordance with the National Electrical Code
(ANSI/NFPA 70, latest edition). In Canada, electrical grounding must be in
accordance with the current CSA C22.1 Canadian Electrical Code Part 1 and/or
local codes. See Electrical Connections in this section.
Do not install this product with an air curtain hood or other cooktop hood
that operates by blowing air down on the cooktop. This airflow may interfere
with operation of the gas burners resulting in fire or explosion hazard.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
-
IMPORTANT — Save these instructions for local inspector’s use.
-
IMPORTANT — Observe all governing codes and ordinances.
-
IMPORTANT — Remove all packing material and literature from appliance before connecting gas and electrical supply to cooktop.
-
IMPORTANT — To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage.
This appliance has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C). -
Note to Installer — Be sure to leave these instructions with the consumer.
-
Note to Consumer — Keep these instructions with your Owner’s Manual for future reference.
-
Servicer — The electrical diagram is in an envelope inside of the cooktop.
-
Proper installation is the responsibility of the installer.
-
Product failure due to improper installation is not covered under warranty.
-
For Monogram local service in your area, 1.800.444.1845.
-
For Monogram Service in Canada, call 1.800.561.3344.
-
For Monogram Parts and Accessories, call 1.800.626.2002.
-
If you received a damaged cooktop, you should contact your dealer.
MOBILE HOME – ADDITIONAL INSTALLATION REQUIREMENTS
The installation of this product must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the
Federal Standard for Mobile Home Construction and Saftey, Title 24, HUD Part
280). When such standard is not applicable, use the Standard for Manufactured
Home Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this product must conform with the current
standards CAN/CSA-A240-latest edition, or with local codes.
When this cooktop is installed in a mobile home, it must be secured during
transit. Any method of securing the cooktop is adequate as long as it conforms
to the standards listed above.
IF SOLD OUTSIDE THE U.S. AND CANADA
WARNING
If you wish to use this product with Liquefied Petroleum (LP) gas containing
greater than 10% butane, you must purchase the butane conversion kit
WB28X29976. To order, please call 1.888.664.8403 or 1.787.276.4051. Failure
to do so may result in carbon monoxide or fire hazard.
VENT HOOD COMBINATIONS
A suitable overhead vent hood is recommended.
READ AND SAVE THESE INSTRUCTIONS
Design Information
PRODUCT DIMENSIONS AND CLEARANCES FOR 30” MODELS * As defined in the National Fuel Gas Code (ANSI 2223.1, Current
Edition). Clearances from non-combustible materials are not part of the ANSI
Z21.1 scope and are not certified by UL. Clearances less than 3-7/8”must be
approved by local codes and/or the authority having jurisdiction.
WARNING
Installations without a hood require 30” minimum to combustibles. A custom
hood installation with exposed horizontal combustible surfaces must have an
Auto-On feature. Refer to hood installation instructions for specific hood
clearances.
Clearances less than 3-7/8” from cutout to rear wall require the surface of
the entire back wall above the cooktop and below the hood to be covered with a
noncombustible material. The material should be no less than 0.25” (6.4 mm)
thick flame-retardant millboard covered with no less than No. 28 MSG sheet
metal 0.015” (0.38 mm) thick, 0.015″ (0.38 mm) thick stainless steel, 0.25”
(0.64 mm) aluminum or 0.020” (0.5 mm) copper.
CAUTION
To prevent drafts from affecting burner operation, seal all openings in floor
under appliance and behind appliance wall.
ADDITIONAL CLEARANCES:
Allow 12” minimum clearance to an adjacent wall on each side.
Working areas adjacent to the cooktop should have 18” minimum clearance
between countertop and the bottom of the wall cabinet.
NOTE: Allow 7/16” minimum vertical clearance from the cooktop bottom (or
4-9/16” minimum depth from the countertop) to any combustible surfaces, such
as a cabinet drawer.
For island installation, maintain 1-1/2 in. minimum from cutout to front and
2-1/2 in. minimum from cutout to back edge of countertop. Maintain 3 in.
minimum from cutout to side edges of countertop.
PRODUCT DIMENSIONS AND CLEARANCES FOR 36” MODELS
* As defined in the National Fuel Gas
Code (ANSI 2223.1, Current Edition). Clearances from non-combustible materials
are not part of the ANSI Z21.1 scope and are not certified by UL. Clearances
less than 3-7/8”must be approved by local , codes and/or the authority having
jurisdiction.
PRODUCT DIMENSIONS AND CLEARANCES FOR 30” AND 36” MODELS
For Americans with Disabilities Act (ADA) Forward Approach Installation
Only:
NOTE: The enclosure must be made of wood material.
Also, an access panel is required for the electrical outlet, pressure
regulator, shut-off valve, hold-down brackets, and service.
Installation Options
COOKTOP INSTALLATION WITH A MONOGRAM DOWNDRAFT VENT
(See Monogram.com for approved combo installations)
The installation of the downdraft vent with this cooktop requires careful
consideration. Both the cooktop and the vent must be installed according to
each specific installation instruction.
COOKTOP REQUIREMENTS
The countertop must have a deep flat surface to accommodate the cooktop and
vent. Countertops with a rolled front edge and backsplash will not provide the
flat surface area required.
- Review the illustration to determine the countertop surface requirements.
— All cutout clearances for this installation must be observed.
A | B | C | D |
---|---|---|---|
30” | 28-1/2” | 19-5/8” | 2-7/8” |
36” | 33-7/8” | 19-1/8” | 3-3/8” |
BASE CABINET REQUIREMENTS
The combined installation will fit in a standard 24” deep base cabinet. Use a
30” or wider base cabinet.
— The vent housing, blower and ductwork will occupy the base cabinet.
POWER SUPPLY
If local codes permit, the vent and cooktop may operate from the same 120V, 15
amp duplex outlet. Locate the gas and electrical supply.
COOKTOP INSTALLATION OVER A MONOGRAM WARMING DRAWER
(See Monogram.com for approved combo installations)
These cooktops may be installed over a 30” or 27” Warming Drawer. Both the
cooktop and the warming drawer must be installed according to each specific
installation instruction.
POWER SUPPLY
If local codes permit, the cooktop and warming drawer may operate from the
same 120V duplex outlet. Refer to installation instructions for
details.
Warming Drawer | A |
---|---|
30” | 28-1/2” |
27” | 25-1/2” |
Cooktop | B |
--- | --- |
30” | 28-1/2” |
36” | 33-7/8” |
NOTE: When installing a Monogram Warming Drawer below a cooktop, a solid
barrier must be installed at least 1″ from the lowest point of the bottom of
cooktop burner box to the top of cutout. See Warming Drawer Installation
Instructions for details.
Use a 30” or wider base cabinet.
- Plan gas supply location carefully to avoid interference with the warming drawer.
COOKTOP INSTALLATION OVER A 27” OR 30” MONOGRAM SINGLE OVEN
(SeeMonogram.com for approved combo installations)
These cooktops may be installed over the Monogram single oven. Both the
cooktop and the oven must be installed according to each specific installation
instruction.
— Allow 4″ Min. clearance from the top of the countertop to the top of the
oven cutout.
POWER SUPPLY
The oven requires a separate, properly grounded 20 Amp, 3-wire 208 or 240
volt, 60 Hz power supply. The cooktop requires a separate 120V power supply.
Where codes permit, the gas shut-off valve may be located in an adjacent
cabinet or other easily accessible location.
Ovens | A | B |
---|---|---|
30” | 28-1/2″ min. | |
28-5/8″ max. | 27-1/4″ min. |
27-5/16″ max.
27”| 25″ min. 25-1/4″ max.| 27-5/8″ min.
28-1/8″ max.
Cooktop| C| D
---|---|---
30”| 28-1/2”| 19-5/8”
36”| 33-7/8”| 19-1/8”
Use a 30” or wider base cabinet.
- For best appearance, the cooktop should be centered over the oven.
Installation Information
MATERIALS PROVIDED MATERIALS REQUIRED (not provided) NOTE: Purchase new flexible line; do not use previously used flexible gas line.
TOOLS REQUIRED
1 REMOVE PACKAGING
- Remove packaging tape and foam. Dispose of packaging materials properly.
- Slide the cooktop out of the end of the box. Remove packaging materials, grate boxes, regulator and literature package from the cooktop before beginning installation.
- Use the shipping carton as a pad to protect customer countertops or flooring.
2 CUT THE COUNTERTOP OPENING
Dimensions
| A| B| C| D
30” Cooktop| 2-7/8”| 19-5/8”| 28-1/2”| 30”
36” Cooktop| 3-3/8”| 19-1/8”| 33-7/8”| 36”
Use a 30″ or wider base cabinet.
• Cut the opening in the countertop. To ensure accuracy, it is best to make a
template for the opening. Make sure the sides of the opening are parallel and
the rear and front cuts are exactly perpendicular to the sides.
• Observe all minimum clearances.
3 INSTALLING THE COOKTOP
A. Locate electrical outlet and gas shut-off valve beneath cabinet.
B. Lay cooktop upside down on a towel or tablecloth covered countertop.
C. Locate and remove hold-down brackets from literature package.
D. Attach brackets to cooktop. Remove the screw from the side of the cooktop
and screw the holddown bracket to the side of the cooktop unit.
Repeat for opposite side of cooktop.
E. Insert the cooktop centered into the cutout opening. Make sure the front
edge of the countertop is parallel to the cooktop. Make final check that all
required clearances are met.
Once the unit is in place, screw the hold-down bracket into the cabinet sides
to secure the unit into place.
4 CONVERSION TO PROPANE (LP) OR NATURAL GAS
The pressure regulator and the burner orifices are set for natural gas at
the factory. To operate the cooktop with propane (LP), the regulator and
burner orifices must be converted. The conversion must be performed by a
qualified propane (LP) gas installer.
Keep these instructions and all orifices in case you want to convert back to
natural gas.
5 GAS SUPPLY
WARNING
Fire Hazard: Do not use a flame to check for gas leaks.
WARNING
Explosion Hazard: Do not exceed 25 ft-lbs of torque when making gas line
connections.
Overtightening may damage the pressure regulator resulting in fire or
explosion hazard.
Gas Pressure Regulator
You must use the gas pressure regulator supplied with this cooktop. For
proper operations the inlet pressure to the regulator should be as follows:
Natural Gas:
Minimum pressure: 6” of Water Column
Maximum pressure: 13” of Water Column
Propane (LP) Gas:
Minimum pressure: 11” of Water Column
Maximum pressure: 13” of Water Column
If you are not sure about the inlet pressure contact local gas supplier.
Shut off the main gas supply valve before disconnecting the old cooktop and
leave it off until the new hook-up has been completed. Don’t forget to relight
the pilot on other gas appliances when you turn the gas back on.
Because hard piping restricts movement of the cooktop, the use of a CSA
International-certified flexible metal appliance connector is recommended
unless local codes require a hard-piped connection.
If the hard piping method is used, carefully align the pipe; the cooktop
cannot be moved after the connection is made.
To prevent gas leaks, put pipe thread sealant on, or wrap pipe thread tape
with Teflon around all male (external) pipe threads.
A. Install provided pressure regulator directly to the gas inlet pipe of the
cooktop. Refer to the arrow on the back of the regulator for gas flow
direction.
Ensure the front of the regulator is facing towards the cabinet front, easily
accessible through the cabinet doors.
B. Install a manual shut-off valve in the gas line in a location easily
accessible through the cabinet doors.
C. When all connections have been made, ensure all gas controls are in the off
position and turn on the main gas supply valve. Use a liquid leak detector at
all joints and connections to check for leaks in the system.
Teflon: Registered trademark of DuPont
When using pressures greater than 1/2 psig to pressure test the gas supply
system of the residence, disconnect the cooktop and individual shut-off valve
from the gas supply piping. When using pressures of 1/2 psig or less to
pressure test the gas supply system, simply isolate the cooktop from the gas
supply system by closing the individual shut-off valve.
When checking for proper operation of the regulator, the inlet pressure must
be at least 1” greater than the operating (manifold) pressure as given on
rating label of product.
CONNECTOR HOOKUP
TYPICAL INSTALLATION WITH NO OBSTRUCTION BELOW COOKTOP A. 3/8″ NPT x 3/8”
NPT threaded adapter fitting (on some models)
B. Regulator provided with unit:
• Outlet – 3/8” NPT female pipe thread
• Inlet – 1/2” NPT female pipe thread
C. Adapter
D. Flexible connector
E. Adapter
F. Manual shut-off valve
G. Gas pipe 1/2” or 3/4”
ALTERNATE INSTALLATION WITH OBSTRUCTION BELOW COOKTOP A. 3/8” NPT x 3/8″ NPT
threaded adapter fitting (on some models)
B. Elbow
C. Adapter
D. Flexible connector (allows passage through cabinet wall)
E. Adapter
F. Regulator provided with unit:
• Outlet – 3/8” NPT female pipe thread
• Inlet – 1/2” NPT female pipe thread
G. Gas pipe
H. Manual shut-off valve
I. pipe 1/2” or 3/4”
6 ELECTRICAL CONNECTIONS
WARNING
Shock Hazard: This appliance must be properly grounded. Failure to do so can
result in electric shock.
Electrical Requirements – 120-volt, 60 Hertz, properly grounded dedicated
circuit protected by a 15-amp or 20-amp circuit breaker or time delay fuse.
NOTE: Use of automatic, wireless, or wired external switches that shut
off power to the appliance are not recommended for this product.
Grounding
The power cord of this appliance is equipped with a three-prong (grounding)
plug which plugs into a standard three-prong grounding wall receptacle to
minimize the possibility of electric shock hazard from this appliance.
The customer should have the wall receptacle and circuit checked by a
qualified electrician to make sure the receptacle is properly grounded.
Where a standard two-prong wall receptacle is encountered, it is the personal
responsibility and obligation of the customer to have it replaced with a
properly grounded three-prong wall receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE THIRD (GROUND) PRONG FROM
THE POWER CORD. DO NOT USE AN ADAPTER. DO NOT USE AN EXTENSION CORD.
Ground Fault Circuit Interrupters (GFCI’s) are not required or recommended for
gas cooktop receptacles.
Performance of the cooktop will not be affected if operated on a GFCl-
protected circuit but occasional nuisance tripping of the GFCI breaker may
occur.
7 CHECK BURNERS
WARNING
Fire or Explosion Hazard: Do not operate the burner without all burner
parts in place.
A. Burners – Place surface burners into corresponding positions on cooktop.
B. Caps – Place caps on proper size burner. C. Grates – The left and right
grates are interchangeable. Place the grates on the cooktop.
Place the two side grates so that a continuous “line” is formed with the
center ribs of both grates.
Make sure both grates are stable and level.
8 CHECK SURFACE BURNERS
Push and turn a knob to the LITE position. A clicking sound indicates
proper operation of the ignition system. When lighting any burner, sparks will
appear at all burners but gas flows from only the one selected.
Once air is purged from the supply line, burner should light within 4 seconds.
After burner lights, rotate the knob out of the LITE position. Try each burner
in succession until all burners have been checked.
Quality of Flames
Determine the quality of flames visually. Normal burner flames should look
like (A) or (B).
| (A) Soft blue flames—
Normal for natural gas
---|---
| (B) Yellow tips on outer cones—
Normal for propane (LP) gas
Long, bright yellow flames are not normal. Normal flames may show signs of an orange tint when well heated or signs of flickering orange due to particles in the gas or air.
WHEN ALL HOOKUPS ARE COMPLETED
Check that all packing materials and tape have been removed. This will include
tape on metal panel under control knobs (if applicable), adhesive tape, wire
ties, cardboard and protective plastic. Failure to remove these materials
could result in damage to the appliance once the appliance has been turned on
and surfaces have heated.
FINALIZE INSTALLATION
Place the burner grates over the burners. The grates should be seated and
should not rock.
INSTALLATION CHECKLIST
- Make sure all controls are left in the OFF position.
- Make sure the flow of combustion and ventilation air to the cooktop is unobstructed.
- Recheck Steps:
Double check to make sure everything in this manual has been completed. Rechecking steps will ensure safe use of the cooktop.
NOTE: The rating plate is located on the bottom of the cooktop. The model and serial number may also be found behind the left knob and is visible when the knob is pulled off.
Installation Instructions
Conversion to Propane (LP) or Natural Gas
WARNING
Explosion Hazard
Death or serious injury can result from failure to follow these
instructions.
- Service by a qualified service technician only.
- Shut off gas supply and disconnect power before servicing.
- Reconnect all grounding devices after service.
- Replace all parts and panels before operating.
The pressure regulator and the burner orifices are factory set for natural
gas. To operate the cooktop with propane (LP) gas, the regulator and burner
orifices must be converted by following these instructions:
WARNING
Do not operate the cooktop before converting the burner orifices for the
gas to be used.
Failure to do so could cause high flames and toxic fumes which can result in
serious injury.
TOOLS YOU WILL NEED FOR CONVERSION
1 CONVERT THE REGULATOR
Disconnect all electrical power at the main circuit breaker or fuse box.
A. Shut off the gas supply to the cooktop by closing the manual shut-off
valve.
B. Adjust the pressure regulator by the following instructions:
- Unscrew the cap.
- Carefully look at the spring retainer to locate the NAT or propane (LP) position.
- Turn the spring retainer over by rotating it 90 deg., pull it from the cap, turn the spring retainer over so that propane (LP) is showing, insert it back into the cap, and then rotate it 90 deg. into position.
- Screw the cap back onto the regulator and tighten.
2 CHANGE BURNER ORIFICES
INSTALLATION TIP: First remove all orifices and then start replacing
them. This will help to prevent the possibility that some may not be replaced.
A. Remove the burner grates, burner caps and burner heads.
B. Loosen the top burner orifices using a 7mm nut driver. Use small pliers to
carefully lift out the orifices. The main orifice is located low in the center
of the burner, while the simmer orifice is located higher beside the center of
the burner. A. Remove the propane (LP) orifices from the bracket attached to
the regulator. The top and side surface of the orifices are engraved for
identification. Use the table and figure to determine the placement of the
propane (LP) orifices.
B. Using a 7mm or 9/32” nut driver, install the propane (LP) orifices in their
precise locations.
To prevent leakage, make sure the orifices are securely screwed into the gas
injets.
C. Install the old orifices into the metal bracket along with these
instructions, and replace onto the regulator for possible future conversion.
D. Replace the burner heads, caps and top grates.
| 108 – Denotes 1.08mm orifice size opening
XL – Denotes propane (LP)
---|---
| 95 – Denotes 0.95mm orifice size opening
L – Denotes propane (LP)
BURNER OUTPUT RATINGS: BTU/HR
Propane (LP) Gas 10” W.C.P.
BURNER| BTU RATE| ORIFICE SIZE (mm)| MARKING
LF| 10,000| |
Main| N/A| 0.88| 88XL
Simmer| N/A| 0.34| 34SL
LR| 10,000| |
Main| N/A| 0.88| 88XL
Simmer| N/A| 0.34| 34SL
C| 18,000| |
C1| N/A| 0.686| 69L
C1| N/A| 0.686| 69L
C1| N/A| 0.686| 69L
C2| N/A| 0.41| 41L
RR| 10,000| |
Main| N/A| 0.88| 88XL
Simmer| N/A| 0.34| 34SL
RF| 12,000| |
Main| N/A| 0.97| 97XL
Simmer| N/A| 0.34| 34SL
3 CHECK SURFACE BURNERS
Push and turn a knob to the LITE position.
A clicking sound indicates proper operation of the ignition system.
When lighting any burner, sparks will appear at all burners but gas flows from
only the one selected. Once air is purged from the supply line, burner should
light within 4 seconds.
After burner lights, rotate the knob out of the LITE position. Try each burner
in succession until all burners have been checked.
Quality of Flames
Determine the quality of flames visually. Normal burner flames should look
like (A) or (B).
| (A) Soft blue flames—
Normal for natural gas
---|---
| (B) Yellow tips on outer cones—
Normal for propane (LP) gas
Long, bright yellow flames are not normal. Normal flames may show signs of an
orange tint when well heated or signs of flickering orange due to particles in
the gas or air.
NOTICE:
Save these orifices removed from the appliance for future use.
4 ADJUSTING LOW FLAME SETTING ON COOKTOP BURNERS
This procedure adjusts the low flow of the upper ring of flames on each of
the 4 dual stack burners. The lower row of flames is not adjustable.
Low setting adjustments must be made with 2 other burners in operation on a
medium setting.
This procedure prevents the low flame from being set too low, resulting in the
flame being extinguished when other burners are turned on.
A. Turn on surface burners to medium setting.
B. Turn the knob on the burner being adjusted to “LO”.
C. Remove the knob and insert a small flat blade screwdriver in the valve
shaft as shown.
Turn counterclockwise as far as possible while maintaining a stable flame.
Repeat for alli valves.
D. If flame appears too low or unstable, slowly tum adjustment screw clockwise
until a stable flame exists for each burner.
E. Additionally, for each burner being adjusted, quickly open and close the
cabinet doors while observing the flame. If flame is extinguished, turn
adjustment screw clockwise for a larger flame.
Repeat door openings until flame is stable.
Round Burners Center adjustment screw for all burners except the Multi-
Ring Burner
Multi-Ring Burner (on some models)
Multi-Ring Burner
- Turn on burner to MED setting to adjust the outer ring. Turn the outer ring adjustment screw (in the center of the valve shaft) counterclockwise so that the outer ring flames barely curl over the top edge of the burner cap.
- Turn on burner to SIM setting to adjust the center ring. Turn counterclockwise as far as possible while maintaining a stable flame.
- Open and close the cabinet doors while observing the flame. If flame is extinguished, turn adjustment screw clockwise for a larger flame. Repeat door openings until flame is stable.
Multi-Ring Burner
SPECIAL NOTE:
To convert the cooktop back to natural gas, reverse the instructions given in
making propane (LP) adjustments.
NOTICE:
Once the conversion is complete and confirmed, fill out the propane (LP)
sticker and include your name, organization and date conversion was made.
Apply the sticker to the cooktop near the regulator to alert others in the
future that this appliance has been converted to propane (LP). If converting
back to natural gas from propane (LP), please remove the sticker so others
know the appliance is set to use natural gas.
ADDITIONAL INFORMATION
BURNER OUTPUT RATINGS: BTU/HR
NG (Natural) Gas 5” W.C.P.
BURNER| BTU RATE| ORIFICE SIZE (mm)| MARKING
LF| 10,000| |
Main| N/A| 1.28| 128XN
Simmer| N/A| 0.51| 51SN
LR| 10,000| |
Main| N/A| 1.28| 128XN
Simmer| N/A| 0.51| 51SN
C| 20,000| |
C1| N/A| 1.1| 110N
C1| N/A| 1.1| 110N
C1| N/A| 1.1| 110N
C2| N/A| 0.63| 63N
RR Main| 10,000| |
Main| N/A| 1.28| 128XN
Simmer| N/A| 0.51| 51SN
RF| 12,000| |
Main| N/A| 1.45| 145XN
Simmer| N/A| 0.51| 51SN
| 190 – Denotes 1.90mm orifice size opening
XN – Denotes natural gas
---|---
| 198 – Denotes 1.98mm orifice size opening
N – Denotes Natural Gas
NOTE: While performing installations described in this book, safety
glasses or goggles should be worn.
NOTE: Product improvement is a continuing endeavor at GE Appliances.
Therefore, materials, appearance and specifications are subject to change
without notice.
MONOGRAM.COM
Printed in the United States
31-2001097 Rev. 0
04-22 GEA
Documents / Resources
|
MONOGRAM ZGU36ESLSS Stainless Steel Gas
Cooktops
[pdf] Instruction Manual
ZGU36ESLSS, ZGU36ESLSS Stainless Steel Gas Cooktops, ZGU36ESLSS, Stainless
Steel Gas Cooktops, Steel Gas Cooktops, Gas Cooktops, Cooktops
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>