Experience the power and efficiency of Macro Air’s AVD5, a cutting edge direct-drive fan for industrial and commercial spaces. The captivating five- blade AVD5 is a perfect composition of purposeful design, superior performance, and cost efficiency. Elevate your projects with the AVD5, a commanding revelation in air movement.
STANDARD FEATURES:
- 1.0 HP (equivalent) Direct Drive motor, rated for indoor/outdoor use*
- Clearcoat anodized airfoil blades
- Industry leading onboard electronics for unmatched reliability
- Forward, reverse, variable speed
- Integrated VFD/Mount Enclosure
- Safety Components: safety cable, Universal Mount with guy wires, blade retainer links
Pending AMCA Certification
*Pending Conformity to UL Std 507
Certified to CSA Std C22.2 No, 113
STEP 1:
STEP 1: POWER UNIT| |
---|---|---
Item #| Options| Qty
M500-0025-MA| 8-14 ft Power Unit, 1.0 HP Equivalent|
M500.0035-MA| 16-18 ft Power Unit, 1.0 HP Equivalent|
M500-0050-MA| 20-24 ft Power Unit, 1.0 HP -suivalent|
STEP 2: BLADES| |
Item #| Diameter| Qty
60-80008-00| 8 ft / 2.44 m|
60-80010-00| 10ft/ 3.05m|
60-80012-00| 12ft/ 3.66m|
60.80014-00| 14ft/4.27m|
60-80016-00| int/Assn|
60-80018-00| 1811/5.49m|
6040020-00| 20 ft / 6.07 m|
60-80024-00| 24 ft / 7.32 m|
STEP 3:VOLTAGE/PHASE|
Item #
33.21017-00| Options| Qty
208.240V Single Phase, 50/60 Hz AVD5 DROP ENCL (for use with Universal Mount)|
33-21038-00| 208-240V Three Phase, 50/60 Hz AVD5 DROP ENCL (for use with
Universal Mount)|
33.41038-00| 480V Three Phase, 50/60 Hz AVD5 DROP ENCL (for use with Universal
Mount)|
35-21017-00| 208.240V Single Phase, 50/60 Hz AVD5 SCHNEIDER CONT PNL (for use
with Rapid Mount Industrial)|
35-21038-00| 208-240V Three Phase, 50/60 Hz AVD5 SCHNEIDER CONT PNL (for use
with Rapid Mount Industrial)|
35-41038-00 480V Three Phase, 50/60 Hz AVD5 SCHNEIDER CONT PNL (for use with
Rapid Mount Industrial)|
STEP 4:MOUNTING| |
Item #| Options| Qty
60-50150-00| AVD Universal Mount with I-beam Hardware Kit|
60-40049-00| Glulam Hardware Kit|
60-50136-00| Rapid Mount Industrial with I-Beam Hardware Kit (requires drive
in control panel, offboard)|
STEP 5 CONTROLS| |
Item #| Description| Qty
30-90308-00| Digital Remote Assembly (Standard)|
30-04006-00| Controller 4|
30040117-00| Controller 4+ Single Temperature Sensor|
30-04030-01| Controller 30|
30-10012-00| AirLynk – BacNet|
30-10011-00| AirLynk – Lon works|
304403002| Dual Control Enabled Controller 30 (requires AirLynk-BacNet)|
STEP 6 STOCK DROP LENGTHS| Length (m)| Qty
---|---|---
:tern #
5140200-02| Length (ft/in)*
2 ft•| 0.61 m|
51-X0300-02| 3 ft (Standard)| 0.91 m|
51-X0400-02| 4 ft| 1.22 m|
51-X0500-02| 5 ft| 1.52 m|
51-X0600-02| 6 ft| 1.83 m|
51-X0700-02| 7 ft| 2.13 m|
51-X0800-02| 8 ft| 2.44 m|
51-X0900-02| 9 ft| 2.74 m|
51-X1000-02| 10 ft| 3.05 m|
51-F1tin-02| Customization fee|
• Lengths are+- 1″ depending on power unit selection/fan diameter.
X= substitute D for drops with UMH mount, F for drops with Rapid Mount
Industrial (i.e. 51-F0500-02 describes a 5′ drop for use with a Rapid Mount
Industrial).
ft = length n feet (i.e. 04 for 4 feet, 10 for 10 feet)
n = length in inches (i.e. 05 for 5 inches, 10 for 10 niches)
**2 ft is the shortest allowed drop length for AVD5. Lengths shorter than the
standard drop length are not recommended and will not work for some fan
diameters. Consult MacroAir for more details.
DROP LENGTH is the distance from fan mounting point to the blades.
AVD5 fans can only be connected with a single-piece of custom length drop
tube.
Measure the distance from the fan’s mounting point down to the desired fan
blade position and provide this information with the fan order to receive the
correct custom drop length.
For custom drop lengths, order a length longer and Macro Air will cut it down
to the requested length. Estimated lead time is 10 business days.
Do you have a custom color in mind? Custom powder coating is available for all
our blades, mounts and drop lengths.
OPTIONAL: POWDER COATING
Item #| Diameter| Estimated Lead Time| Qty
60-80008-02| 8 ft / 2.44 m| 15 business days|
60-80010-02| 10 ft / 3.05 m| 15 business days|
60-80012-02| 12 ft / 3.66 m| 15 business days|
60-80014-02| 14 ft / 4.27 m| 15 business days|
60-80016-02| 16 ft / 4.88 m| 15 business days|
60-80018-02| 18 ft / 549 m| 15 business days|
60-80020-02| 20 ft / 6.07 m| 15 business days|
60-80024-02| 24 ft / 7.32 m| 15 business days|
ADDITIONAL OPTINS
Item # | Description | Qty |
---|---|---|
1 0-60200-00 | AVD Fuse Disconnect* |
*IEC Compliance requires a fused disconnect switch. Fuse selection is input voltage specific, so fuses are not provided w th purchase of a disconnect.
BASIC SPECIFICATIONS
“For spacing between fan units based on the dimensions of a specific space
please refer to https://macroairfans.com/airviz.
**Sound testing taken with the sensor 5 ft above the ground and 20 ft from the
center of the fan at 20 ft high. Carrier frequency will be audible to some
listeners and s considered normal during operation.
Supplemental nformation on Carrier Frequency and Decibel levels are supplied
with the full product selection guide.
***Applicable to the fan unit only, does not include controller, control panel
and accessories.