HongShang B300 LED Therapy Red Light
Red Light Therapy Panel
Red Light Therapy Panel is our most advanced series of flights, developed for users who want to take their LED light therapy sessions to the next level. Combining five powerful wavelengths of light, the Red Light Therapy Panel features our patent-pending R+NIR+ spectral output utilizing a perfect blend of deep red light consisting of both 630nm wavelengths and660nm alongside an optimized near-infrared blend of 810nm, 830nmand 850nm wavelengths. Additionally, the Red Light Therapy Panel includes fully digital controls with a built-in timer, allowing the ability to connect multiple panels together to create custom sizes, unique to your treatment needs.
Model Specifications
B300
Rating Power | 450W |
---|---|
Net Weight | 9.5kg |
Material | Met al |
G.W. | 13.5kg |
LED QTY | 300LED*1.5W |
Lifespan | 50,000 Hour s |
lrr adiance | 0 inch>220mW/c© O |
Wavelengths | 600nm-850nm *300pcs |
Product Size | 30091075mm |
Single w eight | 11.5kg |
Single size | 3501000120mm |
Carton size | 1140465175mm |
Timer | 5/10/15/20/25/30 minut es |
OVERVIEW
Getting to Know Your Red Light Therapy Pane
WHAT IN THE BOX
Package Contents
- A. LED Therapy Light
- B. Eye Protection
- C. Door Hook
- D. Power Cable
- E. Patch Cable
- F. Hanging Hardware
- G. Cable Assembly & Snap Links
Connecting to the App
Before beginning the assembly of your therapy light, we recommend downloading our companion app. The app will guide you through the setup and configuration of your therapy light.
USING INSTRUCTION
Get Ready
Lay your red light therapy and all of the included hardware out on a padded
surface. For a list of included parts see page 5.
Attach Hanging Hardware
Screw the threaded posts into the top of your light. Next, screw the cable
supports to the top of the threaded posts.
Attach Door Hook(s)
Hang the door hook on the top of any standard-sized door.
Connect Hanging Cables
Connect cable supports to the snap-link. Then, hang the other end of the
cable assembly directly on the door hook. The snap link and attached cable
gripper allows you to adjust the height of your therapy light.
Assembling Your Therapy Light
Adjust light Height
To raise the height of your therapy light, pull down on the height
adjustment cable while supporting the bottom of your light with your other
hand. To lower your light, press the lever on the cable box.
Connect Power Cables
Plug the power cord into the female socket of your therapy light. Next,plug
the other end of the power cord into a wall socket. Be sure to support your
light during adjustment to avoid causing damage or injury.
Red Light Therapy Panel
Your Red Light Therapy Panel has one red power switches, one on either side
of the power cord socket. Each switch controls 100% of the LEDs in your
light.All Red or All NlR Red Light Therapy Panel Combo Red/NIR Red Light
Therapy Panel: lf you purchased a combo light, one switch will control all Red
LEDs and will control all NIR LEDs. To distinguish between the two
wavelengths, note that the Red LEDs will light up bright red, while the NIR
LEDs will not give off any color. On a Red Light Therapy Panel, flip both
power switches to the ‘On’ position to use both Red and NlR wavelengths. To
use only Red or only NlR wavelengths,simply turn off the power switch for the
wavelength you don’t want to use.
Powering On Your Red Light Therapy Panel
Initial Startup
Flip the red power switch to the ‘On’ position and make sure that it is
illuminated. The logo will display on the screen.The main menu will be
displayed later.
Main Menu
- From the Main Menu, you may further select the sub-menus of the light.
- Press 0N/0FF to enter the (6) 0peration screen, begin the timer and turn the light on using the existing settings in memory.
- Press TlMER to enter the (3) Timer screen
- Press CUSTOM MODE(4) Custom Mode screen
- Press SET to enter the (5) Set screen
Timer
From the Timer screen, you may select a pre-set time or create your own
time using the + and -keys.0nce selected. this time will stay in memory and
the light will default to this when started.Press RUN if creating a custom
time to proceed to the (6) Operation screen, begin the timer and turn the
light on using the existing settings.
Custom Mode
From the Custom Mode screen. you may dim the individual R+ and NlR+ arrays
and create a custom time. Use the + and-keys to adjust the time if desired and
press RUN to proceed to the (6) Operation screen. The settings you make to the
LED arrays and timer will stay in memory each time the light is turned on
until you change them again.
Additional Treatment Tips
Set
From the Set screen, you may select to put the light in PRIMARY, SECONDARY
or SOLO mode. This setting will stay in memory and you will not need to select
it each time. Press PRlMARY if this light Will be used as the first light in a
chain of connected lights. Press SECONDARY if this light will be used as a
connected light anywhere in a chain connected to a primary light.Press SOLO if
this light is to be used by itself with no other lights connected in any way.
This function turns off the wireless connectivity feature.
Operation
The Operation screen displays the countdown of the timer as well as the
status of the light that was selected in the (5) Set screen.
Session Duration & Frequency
For optimal cellular benefit in deep tissue treatment. we recommend 10-20
minute sessions for each desired treatment area at a distance of approximately
8 -14″nches from the device with a max of two to three treatment areas per
day. For skin/superficial therapy,we recommend using a greater distance from
the light at around 18″-24″. Time and distance may vary depending on the
individual’s response to the therapy.
Eye Protection
Eye protection isn’t necessary, but we don’t recommend looking directly into
the LEDs as it can be uncomfortable. For this reason,we include a pair of
sunglasses in each package for your comfort.
Clothing
Make sure the area of your body you are treating is fully exposed to the light
and not covered by any fabric or clothing. Areas not being treated may be
covered if you are more comfortable, but clothing is not necessary.
Effects
lt is common to feel gentle warmth during and after your treatment. Over time,
and with consistent treatment, you can expect to feel more muscle relaxation,
reduced stiffness & inflammation, and pain relief. lf any type of discomfort
or excessive sensitivity is felt, please decrease your exposure time or
increase the distance to the light.
Set light types
lf you have more than one light unit, you’ll need to connect your
additional lights together. First, set one unit to be your”PRIMARY”unit using
the instructions found on pages 13-14. Second,set all additional units to be
your “SECONDARY” unit(s) using the same instructions. NOTE -These settings
should be made before assembling the lights on any stands!
Connecting Units Vertically
To connect units vertically, first, hang your Primary unit on the door
hook. Next, lift the second light and line up its threaded posts with the
holes in the bottom of the upper device. Slide the lower threaded posts up
into the holes and then push back to lock them into place.
Connecting Cables
First, connect the power cable to your Primary unit and plug into a wall
socket. Leave the main red power switch off for now. Then, connect your
Primary unit to your Secondary unit using the patch cable. This allows power
to flow through both units. Lastly, connect the units using the coiled digital
connection cable. You may plug this cable into either of the jacks. Now flip
both main red power switches to ON. When connecting more than two lights
together, repeat the chaining process to each light. Connect the first light
to the second, the second to the third, the third to the fourth.
CAUTION: Never exceed a 15A total load when connecting multiple lights!
Connecting Multiple Red Light Therapy Panel
Troubleshooting
Why do some of the LEDs look like they are not working?
Remember that we use NlR (Near-infrared) LEDs in all BIO R/NIR Lights and Red
Light Therapy Panel. These LEDs will appear to not be working or be very dim
because infrared light is virtually invisible to human eyes. They may not look
like it, but they are EXTREMELY bright to your body! lt is normal for the NlR
LEDs to appear in this manner.
Why is my panel not lighting up?
First, please check to make sure that the power cord is fully pushed into the
plug on the light. The first time that the plug is inserted, you may need to
use a little force since the materials are new, Next, try plugging the light
into an alternate outlet. lf the panel is still not lighting up and it is a
Red Light Therapy Panel, check to make sure that the red, master power switch
on the back of the light is flipped on and illuminated. Second, check the
plug-in on the light for the removable fuse. Remove and check. Please contact
us for further assistance if none of the remedies work.
Why is the second Red Light Therapy Panel connected not lighting up? Why is
it not being controlled by the first panel?
First, please check to make sure that the jumper power cord is fully pushed in
into the plug on the light and that the red, master power switch is flipped to
the on position and is illuminated. lf the panel is still not lighting up,
check the plug-in on the light for the removable fuse. For digital control,
make sure that the small. the black cord is plugged into both lights in either
hole. Make sure that the light that is plugged in from the wall – the
“PRlMARY” light – has its menu option set to”PRIMARY”. Make sure that the
other light that is plugged into the “Primary” light has its menu option set
to “SECONDARY”. lf you are still experiencing problems, please contact us for
further assistance.
FCC WARNING
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, under Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used by the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
To maintain compliance with FCC’s RF Exposure guidelines, This equipment should be installed and operated with a minimum distance between 20cm of the radiator and your body: Use only the supplied antenna.