FIXING METHODS FOR GREEN WALL PRODUCTS
Articles | On metal frame | On sheet | On masonry wall |
---|---|---|---|
Enclosures and distribution boards |
Junction boxes
Boxes for interlocked socket-outlets 67IB and 44IB
| |
(with tabs*)
|
Boxes for domestic ranges – 3, 4, 6/7 gangs
Boxes for round domestic ranges – 2 and 2+2 gangs
| |
(with clamps)
|
Box for domestic ranges – 8 gangs (4+4)| |
(with tabs*)
|
- Tabs on the sides of the horizontal walls. Boards (24, 36, 54, 72 modules) and box for interlocked socket-outlets (67 IB) equipped with fixing tabs on the sides of the vertical walls.
FIXING ON A METAL FRAME
The products can be fixed on a metal frame in two ways: for products with tabs
on the sides of the horizontal walls, use an extra horizontal frame; for
products with tabs on the sides of the vertical walls, use vertical uprights.
The structure is created with the aid of special screws for use with
plasterboard, then the back-mounting box is fixed to the frame by means of the
tabs.
FIXING ON PLASTERBOARD
METHOD A: WITH TABS
The back-mounting box is fixed to the back of the sheet with the aid of the
tabs, then anchored from the front of the sheet with special screws for use
with
plasterboard.
METHOD B: WITH CLAMPS
The boxes for modular domestic ranges (3,4,6 gangs) and the round boxes can be fixed directly to walls (even double sheet walls) using the metal clamps. To prepare the sheet for the installation of the boxes, use a hollow mill ø 68 (for rectangular boxes of 3,4,6 gangs) or a hollow mill ø 65 (for round boxes), using the references on the boxes themselves.
FIXING ON A MASONRY WALL
The back-mounting boxes of the PT DIN GREEN WALL and CM GREEN WALL junction boxes and of the boxes for interlocked switched socket-outlets are equipped with special reference points so they can be fixed to masonry walls with the aid of wall plugs.
40 CDKi GREEN WALL
MODULAR PROTECTED ENCLOSURES AND DISTRIBUTION BOARDS – IP40
TECHNICAL CHARACTERISTICS
Regulation: IEC EN 606070-1 (CEI 23-48); IEC EN 60670-24 (CEI 23-49) (*).
Suitable for assemblies in compliance with IEC EN 61439-1 and IEC EN 61439-3
Degree of protection: IP 40 (even with open door)
Protection against indirect contacts: double insulation – (•)
Installation temperature: max. +60°C, min. -15°C
Rated voltage: 400V
Rated insulation voltage: 750V
Rated current: 125A
Material: GW PLAST technopolymer, halogen-free in accordance with EN 60754-2 (CEI EN
50267-2-2)
Impact resistance: IK 08
Heat resistance: thermo-pressure with ball 70°C
Resistance to abnormal heat and fire: Glow wire test 850°C
Installation: for mobile and plasterboard walls
Use: Indoor
(•) Complete insulation, in accordance with Standard EN 61140.
Notes: H-type casing in compliance with EN60670-24, and Ha-type in compliance with IEC60670-24.
(*) Enclosure type: GP (CEI 23-51) and PD
BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS
Saline solution|
Acids
| Bases|
Solvents
| Mineral oil| UV rays
Concentrated| Diluted| Concentrated| Diluted| Hexane|
Benzol| Acetone| Ethyl alcohol
Resistant| Not resistant| Limited resistance| Not resistant| Limited
resistance| Resistant| Not resistant| Not resistant| Limited resistance|
Limited resistance| Limited resistance
ENCLOSURES AND BOARDS
48 PT DIN GREEN WALL
JUNCTION, CONNECTION AND DOMOTIC BOX – IP40
TECHNICAL CHARACTERISTICS
Regulation: EN 60670-1; EN 60670-22; IEC 60670-24
Degree of protection: IP 40
Installation temperature: max. +60°C; min. -15°C
Material: GW PLAST technopolymer, halogen-free in accordance with CEI EN 60754-2
(CEI EN 50267-2-2)
Impact resistance: IK 07
Heat resistance: thermo-pressure with ball 70°C
Resistance to abnormal heat and fire: Glow wire test 850°C
Installation: for mobile and plasterboard walls
Notes: H-type casing in compliance with EN60670-22, and Ha-type in compliance with IEC60670-22.
BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS
Agent| Saline solution| Acids| Bases| Solvents|
Mineral oil| UV rays
Concentrated| Diluted| Concentrated| Diluted| Hexane|
Benzol| Acetone| Ethyl alcohol
48 PT / PT DIN standard cover| Resistant| Not resistant| Not resistant|
Limited resistance| Limited resistance| Not resistant| Not resistant| Not
resistant| Limited resistance| Limited resistance| Limited resistance
Shockproof cover for 48 PT / PT DIN| Resistant| Not resistant| Limited
resistance| Not resistant| Limited resistance| Resistant| Not resistant| Not
resistant| Limited resistance| Limited resistance|
Limited resistance
JUNCTION BOXES
48 CM GREEN WALL
HIGH-CAPACITY CONNECTION AND JUNCTION BOX – IP40
TECHNICAL CHARACTERISTICS
Regulation: EN 60670-1; EN 60670-22; IEC 60670-24;
Degree of protection: IP 40 (IP 44 spare covers)
Installation temperature: max. +60°C, min. -15°C
Material: GW PLAST technopolymer, halogen-free in accordance with
EN 60754-2 (CEI EN 50267-2-2)
Impact resistance: IK 07 (IP40 box)
IK 10 (IP44 cover)
Heat resistance: thermo-pressure with ball 70°C
Resistance to abnormal heat and fire: Glow wire test 850°C
Installation: for mobile and plasterboard walls
Notes: H-type casing in compliance with EN60670-22, and Ha-type in compliance with IEC60670-22.
BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS
Saline solution
| Acids| Bases| Solvents| Mineral oil|
UV rays
Concentrated| Diluted| Concentrated| Diluted| Hexane|
Benzol| Acetone| Ethyl alcohol
Resistant| Not resistant| Not resistant| Limited resistance| Limited
resistance| Not resistant| Not resistant| Not resistant| Limited resistance|
Limited resistance| Limited resistance
HIGH-CAPACITY JUNCTION BOXES
24 SC GREEN WALL
FOR MODULAR RANGES, KNX DEVICES AND DIGITAL VISION
TECHNICAL CHARACTERISTICS
Regulation: IEC EN 60670-1 (CEI 23-48)
Degree of protection: IP 40
Installation temperature: max. +60°C, min. -15°C (min. -25°C for boxes with 3,4,6 gangs)
Material: GW PLAST technopolymer, halogen-free in accordance with EN 60754-2 (CEI
EN 50267-2-2)
Impact resistance: IK 07
Heat resistance: thermo-pressure with ball 70°C
Resistance to abnormal heat and fire: Glow wire test 850°C
Installation: for mobile and plasterboard walls
Notes: H-type casing in compliance with EN60670-1, and Ha-type in compliance with IEC60670-1.
BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS
****|
Saline solution
| Acids| Bases| Solvents| Mineral oil|
UV rays
Concentrated
| Diluted| Concentrated| Diluted| Hexane| Benzol| Acetone|
Ethyl alcohol
Boxes with 3, 4 and 6 gangs| Resistant| Not resistant| Not resistant| Limited
resistance| Limited resistance| Not resistant| Not resistant| Not resistant|
Limited resistance| Limited resistance| Limited resistance
Round boxes| Resistant| Not resistant| Not resistant| Limited resistance|
Limited resistance| Not resistant| Not resistant| Not resistant| Limited
resistance| Limited resistance| Limited resistance
Boxes (with fixing tabs)| Resistant| Not resistant| Not resistant| Limited
resistance| Limited resistance| Not resistant| Not resistant| Not resistant|
Limited resistance| Limited resistance| Limited resistance
BOXES FOR MODULAR RANGES, KNX DEVICES AND DIGITAL VISION
FLUSH-MOUNTING BOXES FOR INTERLOCKED SWITCHED SOCKET-OUTLETS
TECHNICAL CHARACTERISTICS
Regulation: EN 60670-1 (CEI 23-48)
Installation temperature: min -15°C, max. +60°C
Material: GwPlast technopolymer, Halogen Free according to EN 60754-2 (CEI EN 50267-2-2)
Impact resistance: IK07
Heat resistance: thermo-pressure with ball 70°C
Resistance to abnormal heat and fire: Glow wire test 850°C
Notes: H-type casing in compliance with EN60670-1, and Ha-type in compliance with IEC60670-1.
BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS
Saline solution| Acids| Bases| Solvents| Mineral oil|
UV rays
Concentrated| Diluted| Concentrated| Diluted| Hexane|
Benzol| Acetone| Ethyl alcohol
Resistant| Not resistant| Not resistant| Limited resistance| Limited
resistance| Not resistant| Not resistant| Not resistant| Limited resistance|
Limited resistance| Limited resistance