ATG Epower ATG-PS-04-1kW8 Portable Energy Storage Power Supply User Manual
- June 11, 2024
- ATG Epower
Table of Contents
ATG-PS-04-1kW8 Portable Energy Storage Power Supply
“`html
Specifications:
- Net weight: kg / lbs
- Dimension: mm ( . . in)
- Capacity: ** Wh
- Wi-Fi: supported
Output:
- USB-A (x )
- USB-A quick charge x2
- USB-C (x )
- Car charger DC5521 output x2
-
- Car charge and DC share power
Input:
-
(ATG-PS-04-1kW8) AC input voltage: 100-120V~
(50Hz/60Hz) -
AC input power charge only mode: 1200W, 15A
Max. -
AC input power (bypass mode): 1800W, 15A
Max. -
Car charging input: V/ V battery supported, A
by default -
PV charge: W, 1 -4 V ADC A Max.
Battery:
-
Cell Type: lithium iron phosphate battery
(LiFePO ) -
Life cycle: remaining capacity still over %
after , cycles -
Protection type: over temperature, low
temperature, over discharge, over charge, over load, short circuit,
over current protection -
Charge temperature:
-
Discharge temperature:
Product Usage Instructions:
1. Product Overview:
Provide an overview of the product and its main
functionalities.
2. LCD Screen:
Explain the information displayed on the LCD screen and how to
interpret it.
3. Usage:
Guide users on how to operate the product efficiently and
effectively.
4. AC Charging:
Instructions on how to charge the product using an AC power
source.
5. PV Charging:
Explain how to charge the product using solar panels.
6. Car Charging:
Instructions for charging the product using a car charger.
7. Intelligent Inversion:
Detail the intelligent inversion feature and how it benefits
users.
8. APP:
Information on how to use the product’s accompanying mobile
application.
9. EPS Function:
Explain the Emergency Power Supply function and when to utilize
it.
FAQs (Frequently Asked Questions):
1. Question 1?
Answer 1.
2. Question 2?
Answer 2.
“`
ATG-PS-04-1kW8
USER MANUAL
Content
. Parameters . Safety guidelines
2.1 Use 2.2 Discard
. Guideline for users
3.1 Product overview 3.2 LCD screen 3.3 Use 3.4 AC charging 3.5 PV charging
3.6 Car charging 3. Intelligent inversion 3. APP 3. EPS function
. FAQs (Frequently Asked Questions) . Error messages & solutions . What’s in
the box . Maintenance
8. Disclaimer
1. Parameters
General
Net weight Dimension Capacity Wi-Fi
kg . lbs
** Wh
mm ( . . in)
supported
1 Output
USB-A (x ) USB-A quick chargex2 USB-C (x ) Car charger DC5521 outputx2 * Car charge and DC share power,
5V 2.4A (constant voltage), 12W Max./output 5V 3A 9V 2A 12V 1.5A (constant voltage), 18W Max./output 5/9/12/15V 3A 20V 5A (constant voltage),100W Max./output 12.6V 10A, 126W Max. 12.6V 3A W Max.
Input
(ATG-PS-04-1kW8) AC input voltage
AC input powercharge only mode AC input power (bypass mode)
100-120V~ (50Hz/60Hz) 1200W, 15A Max. 1800W, 15A Max.
Car charging input PV charge
V/ V battery supported, A by default W, 1 -4 V ADC A Max.
13
Battery
Cell Type Life cycle
lithium iron phosphate battery (LiFePO ) remaining capacity still over % after ,
cycles
Protection type
over temperature protection, low temperature protection, over discharge protection, over charge protection, over load protection, short circuit protection, over current protection
Charge temperature
~ ( ~ °F
Discharge temperature
– ~ (- ~ °F)
*Whether the product can be charged or discharged is subject to the actual battery pack temperature.
2. Safety guidelines
2.1 Use
. Do not let a working ATG-PS-04-1kW8 be close to the heat source, such as
fire or heater. . Do not make ATG-PS-04-1kW8 contact with any liquid. . Do not
use ATG-PS-04-1kW8 in a strong electrostatic or strong magnetic field
environment. . Do not disassemble ATG-PS-04-1kW8 in any way or pierce it with
a sharp object. . Do not short ATG-PS-04-1kW8 by wire or other metal objects.
. Do not use ingenuine parts or accessories. For part or accessory
replacement, please visit official sales channel for purchase information. .
When using ATG-PS-04-1kW8, please follow the operating temperature defined in
this user manual strictly. If the temperature is too high, battery may catch
fire or even explode. If the temperature is too low, ATG-PS-04-1kW8
performance will be seriously impaired, even normal use will be impacted. . Do
not stack heavy objects on ATG-PS-04-1kW8. . Do not stop the fan by force or
expose SR KW L-SG in an unventilated or dusty environment when it is working.
. Please avoid collision, drop, and violent vibration. If severe impact
happens, shut down the power supply immediately. Please fix ATG-PS-04-1kW8
firmly during transportation to avoid vibration and impact.
. If ATG-PS-04-1kW8 falls into water accidentally, place it in a safe and wide
area, and keep yourself away from it until it’s dry. Dried product shall not
be used again. Dispose it properly according to chapter . in this user manual.
If ATG-PS-04-1kW8 is on fire, please use fire extinguishing equipment in the
recommended order: water or water mist, sand, fire blanket, dry powder,
dioxide carbon fire extinguisher.
. If there is dirt, use a dry cloth to wipe it. . Place ATG-PS-04-1kW8
carefully to prevent damage. If ATG-PS-04-1kW8 is tipped over and seriously
damaged, turn off TTPS1800WUS immediately and place the battery in a spacious
place and keep it away from flammable materials and people, and scrap it in
accordance with the requirements of local laws and regulations. . Keep ATG-
PS-04-1kW8 out of the reach of children and pets. . Keep ATG-PS-04-1kW8 in a
dry and ventilated place. . In humid environment (seaside, water, etc.), it is
recommended to equip ATG-PS-04-1kW8 with moisture-proof bag. If water is found
inside product, do not use/start it again. Please take countermeasures to
prevent electric shock before touching ATG-PS-04-1kW8. Put it in a safe and
waterproof open area, and contact customer service immediately. . It is not
recommended to use ATG-PS-04-1kW8 to supply power for safety-related emergency
medical equipment, including but not limited to medical grade breathing
machine (hospital version CPAP: Continuous Positive Airway Pressure),
artificial lung (ECMO, Extracorporeal Membrane Oxygenation). It can be used to
supply power for home version CPAP at home and does not require continuous
professional monitoring. Please follow your doctor’s advice and consult the
manufacturer for any restrictions on the use of the device. For general
medical equipment, please pay attention to the power condition to ensure that
power does not run out. . Power supplies will inevitably generate
electromagnetic fields when it is in use, which might affect the implantable
medical device or normal operation of personal medical device, such as
pacemaker devices, cochlear implants, hearing AIDS, defibrillators, etc. If
any of these medical devices are used, please consult the manufacturer about
the restrictions on the use to ensure that ATG-PS-04-1kW8 is operated at a
safe distance from implanted medical devices such as pacemakers, cochlear
implants, hearing AIDS, defibrillators, etc.
19. When the power station is connected to a refrigerator, it may
automatically shut down because of the power fluctuation property of the
refrigerator. When connecting the power supply to a refrigerator that stores
medicine, vaccines or other valuable items, it is recommended to set the AC
output to “Never off” in the APP, so as to ensure continuous power. Users
should pay attention to power consumption.
2.2 Discard
. Conditions permitting, be sure to discharge the battery completely, and then
put ATG-PS-04-1kW8 in the specified battery recycling bin. ATG-PS-04-1kW8
contains batteries, which are dangerous. It is strictly prohibited to discard
them in ordinary dust bins. For details, follow local laws and regulations on
battery recycling and disposal.
. If the battery cannot be discharged completely due to product failure, do
not discard the battery directly in the battery recycling bin. Contact a
professional battery recycling company for further disposal.
. The battery will not start after over discharge. Please dispose it as
discarded.
3. Guideline for users 3.1 Product overview
LCD LCD button USB-C output port x2 AC output button
SR1KW8L-SG1-UK
AC output socket x3 SR1KW8L-SG1-FR
AC output socket x3
Ventilation opening
ON/OFF button USB-A quick charge output x USB-A output port x
ATG-PS-04-1kW8
AC output socket x4 SR1KW8L-SG1-AU AC output socket x3
SR1KW8L-SG1-EU
AC output socket x3 SR1KW8L-SG1-ZA
AC output socket x3
AC input socket
Quick charge / slow charge switch
Ventilation opening
Overload protection switch Solar / car charge input
3.3 Use
NotePress and hold the ON/OFF button for 10 seconds to restart the BMS and
clear the fault information.
Cigarette lighter DC plug X DC output ON/OFF
3.2 LCD screen
PV charge
Slow charge
Fan status
Quick charge
Car charge
Remaining battery percentage Remaining charge /
discharge time Over temperature
warning
Overload Input power Bluetooth Output power
Error code
Low temperature
USB-A output
AC output
warning DC output
USB-C output Wi-Fi connection status
Battery capacity: When SR KW L-SG is being charged, SOC icon will flicker.
Wi-Fi connection status: The flickering icon indicates that SR KW L-SG is
ready for pairing. The icon will keep flickering if a mobile phone and SR KW
L-SG are connected by hotspot. After network connection succeeds, the icon
will always be on. If connection fails, the icon will be off.
- Please refer to clause for more details regarding error message.
On and off
Short press to turn on Long press to turn off
Y Press the main power switch to turn on the device, then the screen will be
lit and the main power indicator will enter the breathing light mode.
Y If no operation is performed to ATG-PS-04-1kW8 for minutes, ATG-PS-04-1kW8
will enter hibernation state and the LCD will automatically turn off. When
there is load change or operation to ATG-PS-04-1kW8 the LCD screen will be
automatically lit. Press the main power switch to turn on or turn off the LCD.
Y Press and hold the main power switch will turn off ATG-PS-04-1kW8 . Y The
default standby time is hours. If other output power switches are not turned
on and not any loads
are connected, ATG-PS-04-1kW8 will automatically shut down after hours.
Standby time can be set on the
APP.
05
Note: When no AC input, long press the above AC output button, you can switch the AC off-grid output
frequency (
/
), long press 2s to switch, the AC output icon will flash 3 times after successful
switching.
3.4 AC charging
Quick charging technology is designed for AC charging. You can control the
charging power via the AC charging speed switch. The slow charge mode is on by
default when ATG-PS-04-1kW8 is turned on, and can be switched to quick charge
mode by the button. Quick and slow charging mode switching can also be set by
APP. If the current is continuously higher than A, the charging input port
will start the self-protection function, and the charging overload protection
switch will automatically trip. Press the charge overload protection switch to
restore charging after confirming no fault.
Short press AC output power switch
USB output
·USB output is enabled by default after the main power switch is turned on.
AC wire
Fully charged in less than hours
SR1KW8L-SG1-UK
ATG-PS-04-1kW8
SR1KW8L-SG1-EU
SR1KW8L-SG1-FR
SR1KW8L-SG1-AU
SR1KW8L-SG1-ZA
AC output
· After the main power is on, press the AC output power switch to enable the
AC output port. Press the AC output power switch again to turn it off.
· The default standby time of the AC output is hour. After hour without any
loads, the AC output power switch will be automatically off.
·When the AC output is not in use, turn it off to save power consumption.
Quick charge and slow charge can be switched by the button. Quick charge enabled
Short press V DC output power switch
V DC output
· After the main power switch is turned on, press the V DC output power switch
to enable the DC output port.
·Press the V DC output power switch again to turn it off. · When the V DC
output power switch is turned on,
SR KW L-SG does not shut down automatically.
The charging power range can be adjusted by APP.
Please use the standard AC charging Cable for fast charging. AC Charging Cable
should directly plug into A (or above) wall-mounted socket. We take no
responsibilities for any damage caused by using unofficial AC charging cable,
and other failures to follow instructions.
3.5 PV charging
Charge the power station by solar panel. *Solar charging cable (DC ) · Please
follow the user manual to connect the solar panels. · Before connecting the
solar panel, check whether its output voltage is within ATG-PS-04-1kW8
specifications to avoid damage to ATG-PS-04-1kW8
3.6 Car charging
ATG-PS-04-1kW8 can be charged by a car charging port. It should be charged
after the car starts, so as to avoid the car battery loss and failure to
start. At the same time, ensure good connection between the car charging port
and cigarette lighter. We take no responsibilities for any loss caused by
improper operation.
3. APP You can control and view information and data about this product by
App.
3. EPS function
This product supports the EPS function. When the grid is connected with ATG-
PS-04-1kW8 AC input port by AC cable, the output port enables the electrical
appliance to work. In such case, power is from grid instead of battery. When
power grid is off, the power station can switch to battery-supplying mode
within mS. Such function is unprofessional EPS, which does not support switch
in mS, so do not connect it to equipment with strict EPS requirement, such as
data server and workstation or please confirm compatibility after tests, and
suggest only use one device instead of multiple devices at the same time so as
not to cause overload to the power station. We shall not be liable for
abnormal work or data loss arising from operation not following this user
manual.
electrical appliance
socket
SR1KW8L-SG1-UK
SR1KW8L-SG1-US
SR1KW8L-SG1-EU
SR1KW8L-SG1-FR
SR1KW8L-SG1-AU
SR1KW8L-SG1-ZA
. Intelligent inversion
To avoid operation faults arising from charging overload, when the total
output power is over the rated output power, the constant output power will be
automatically enabled, so that ATG-PS-04-1kW8 can supply power to the high
power device at rated output power.
Please take note of the following while using constant power:
. The constant power output function is not enabled by default, which can be
turned on or off by App. . In the following cases, constant power output
function is not enabled: ( ) AC output turned on in charging status (bypass
mode). ( ) Constant power output turned off. . Constant power output function
is more suitable for heater and motor instead of all electrical equipment. It
is not suitable forsome electrical appliances with voltage protection (such as
precision instruments). Constant power output function application
is subject to actual testing.
. FAQs (Frequently Asked Questions)
. What kind of battery is used? Lithium iron phosphate battery (LiFePO ).
. What equipment can be connected to the AC output ports? The AC output has
high rating power and maximum power, which enables it to supply power to most
household appliances. Suggest check the equipment power prior to connecting
and make sure power of all equipment lower than rated power.
. How to know the supply time? Time shows in the LCD, which can be referred to
for estimation for equipment with stable power consumption.
. How to know it is charging? When in charge, the LCD shows remaining charging
time. The SOC flickers, and input power is shown.
. How to clean the unit? Clean the unit with a dry, soft and clean cloth or
tissue.
. How to store the unit? Turn it off, and keep it in a dry and ventilated
place. Do not expose it close to water. For long-term storage, suggest
discharge to % and charge to % every months to extend the service life.
. Can it be taken on board? No.
5. Error messages & solutions
Icon Error code always on
Fault Description Serious battery fault
Solution
Turn on and off, contact after sales if still not fixed.
Error code always on Error code always on
V too big BMS voltage fault
Auto shutdown, fault will be cleared after reboot.
High temperature icon flickers
Battery OTP (over
Error code always on
temperature protection) fault
Low temperature icon flickers
Battery UTP (under
Error code always on
temperature protection) fault
Error code always on
OCP (over current protection) fault
Auto shutdown, temperature recovery enables starting up.
Auto shutdown, fault will be cleared after reboot.
High temperature icon flickers Error code always on
Error code always on
OTP fault Pre-charge fault
Auto shutdown, delayed start.
Auto shutdown, fault will be cleared after reboot.
Error code always on Error code always on
Battery under voltage fault Abnormal parallelization
Auto shutdown and charge, contact after sales if still not fixed after
multiple charging failures.
Check the connection cable. Contact after sales if still not fixed. Single
power station function is not affected.
Error code always on
Abnormal INV battery voltage
Auto recover after fault is cleared.
Error code always on
Grid voltage or frequency fault
The fault is cleared when the grid returns to normal.
Error code always on Error code always on
Abnormal INV BUS voltage Abnormal INV output
Auto recover after fault is cleared.
Overload icon always on Error code always on
Overload icon always on Error code always on
Error code always on
INV discharge overload Charge overload INV Tz
Remove over-power device. Auto recover after fault is cleared.
Auto recover after fault is cleared.
Error code always on Error code always on
Battery short INV output short
Fault will be cleared after reboot.
High temperature icon flickers Error code always on
MOSFET OTP fault
Auto recover after product is cooled down.
If there is a warning occurs during the use of this product, and the warning icon still does not disappear after restarting the device, please stop using it immediately (do not try to charge or discharge).
5. Error messages & solutions
Icon Error code always on
Fault Description Fan stop
Solution
Turn on and off, contact after sales if still not fixed.
Error code always on Error code always on
Discharge soft start fault Charge soft start fault
Auto recover after fault is cleared.
Low temperature icon flickers Error code always on
MOSFET UTP fault
Error code always on
Anderson hardware OCP fault
Turn on and off, contact after sales if still not fixed.
Remove PV charge, auto recover after connecting PV and turn on.
Error code always on
Anderson software OCP fault
Turn off output, manual recover after fault is cleared.
Error code always on Error code always on Error code always on
PV hardware OCP fault PV software OCP fault PV software OCP fault
Remove PV charge, auto recover after connecting PV and turn on.
Stop PV charging, auto recover after connecting PV and turn on.
Stop PV charging, auto recover after connecting PV and turn on.
Error code always on Error code always on
Car charge output OCP fault
Turn off output, manual recover after fault is cleared.
PV output OVP
Stop PV. Auto recover after fault is cleared.
(over voltage protection) fault
Error code always on
PV input OVP fault
Stop PV . Auto recover after fault is cleared.
Error code always on
PV input OVP fault
Stop PV . Auto recover after fault is cleared.
High temperature icon flickers Error code always on
Anderson OTP fault
Turn off output, manual recover after fault is cleared.
High temperature icon flickers Error code always on
PV OTP fault
Stop PV . Auto recover after fault is cleared.
High temperature icon flickers Error code always on
PV OTP fault
Stop PV . Auto recover after fault is cleared.
High temperature icon flickers Error code always on
Car charge output OTP fault
Turn off output, manual recover after fault is cleared.
Error code always on
USB icon flickers Error code always on
Abnormal communication
Turn on and off, or change operation environment. Contact after sales if still not fixed.
Abnormal USB
Auto recover after removing abnormal USB.
Type C icon flickers Error code always on
Abnormal type C
Auto recover after removing abnormal type C.
If none of the above information can solve problem you encounter, please contact the customer service for consultation.
6. What’s in the box
. Disclaimer
ATG-PS-04-1kW8
AC cable
Car charge cable
User manual
7. Maintenance
· It is recommended to use or store ATG-PS-04-1kW8 under ~ ambient
temperature. Keep it away from water, heater and metal parts.
· For long-term storage, charge and discharge every months, i.e. discharge to
% then charge to %. · For safety, do not store ATG-PS-04-1kW8 with temperature
above or below – . · If the capacity is lower than %, please charge to %.
Long-term storage with serious power shortage will
cause irreversible damage to the cell and shorten the service life of the
product. · If the capacity is seriously insufficient and idle time is too
long, the product will enter deep sleep mode, and
the product can only be used after being charged.
The product has a built-in battery management system, which has protections
such as overcharge, overdischarge, overcurrent, short circuit, high and low
temperature, and abnormal communication. During the use of this product,
protection may occur and cause output interruption. Power supply to special
equipment, such as medical equipment, server, the indirect loss caused by
accidental power failure has nothing to do with the company; all accidents
caused by illegal use, self-dismantling, and man-made damage have nothing to
do with the company.
Before using the power station ATG-PS-04-1kW8, please read this user manual to
ensure understanding and proper use. After reading the user manual, please
keep it well for future reference. Improper operation may cause serious injury
to yourself or others, or result in product damage and property loss. Once
using ATG-PS-04-1kW8, you are deemed to have understood and accepted all terms
and contents herein. Users promise to be responsible for their actions and all
consequences arising therefrom. We shall not be liable for any loss arising
from user’s not following this user manual.
In compliance with laws and regulations, the company reserves the right of
final interpretation of this document and all related documents of this
product. Subject to update, revision or termination without prior notice,
please visit the official website for the latest product information.
13
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1)This device may not cause harmful
interference. (2)This device must accept any interference received, including
interference that may cause undesired operation. 2. Changes or modifications
not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment. Note:This equipment has been tested
and found to comply with the limits for a class B digital device,pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequence energy and,if
not installed and used in accordance with the instructions,may cause harmful
interference to radio communications.However,there is no guarantee that
interference will not occur in a particular installation.if this equipmemt
does cause harmful interference to radio or television reception,which can be
determined by turning the equipment off and on,the user is encouraged to try
to correct the interference by one or more of the following measures: ·
Reorient or relocate the receiving antenna. · Increase the separation between
the equipment and receiver. · Connect the equipment into an autlet on a
circuit different from that to which the receiver is connected. · Consult the
dealer or an experienced radio/TV technician for help. The device has been
evaluated to meet general RF exposure requirement,This equipment should be
installed and operated with a minumum distance of 20 cm between the radiator
and your body.
ISED Statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s). Operation is subject to the following two conditions: 1.This device
may not cause interference. 2.This device must accept any interference,
including interference that may cause undesired operation of the device. This
equipment should be installed and operated with a minumum distance of 20 cm
between the radiator and your body. Le présent appareil est conforme aux CNR
d’Industrie Canada applicables auxappareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes : (1)l’appareil ne
doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit
accepter toutbrouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre lefonctionnement. CAN ICES-3(B)/NMB-3(B) Cet
équipement doit être installé et utilisé à une distance minimale de 20 cm
entre le radiateur et votre corps.