Specifications

  • General:
    • Net weight: 3 kg
    • Dimension : *
    • Capacity : Wh
    • Wi-Fi supported
  • Output:
    • AC output x
    • Maximum load
    • USB-A (x )
    • USB-A quick charge x2
    • USB-C (x )
    • Car charger DC5521 output x2
  • Input:
    • AC input power: W Max.
    • AC input voltage: – V~ Hz/ Hz
    • PV charge: V/ V battery supported, A by default
  • Battery:
    • Cell Type: lithium iron phosphate battery (LiFePO4)
    • Life cycle: remaining capacity still over % after , cycles
    • Protection type: over-temperature protection, low-temperature protection, over-discharge protection, overcharge protection, overload protection, short circuit protection, over current protection
  • Others:
    • Battery Expansion: Wh, support expansion battery packs at most, separate selling

Product Usage Instructions

  • On/Off Functionality:
    To turn on the device, press the main power switch. The screen will light up, and the main power indicator will enter breathing light mode. To turn off the device, long press the main power switch.

  • Charging Methods:
    The product supports AC charging, PV charging, and car charging. Use the respective input ports for each charging method according to your needs.

  • Battery Expansion:
    If you require additional battery capacity, the product supports expansion battery packs. These packs are sold separately and can be connected to increase the overall capacity.

  • APP Integration:
    The product comes with an accompanying mobile app that allows you to monitor and control various functions remotely. Download the app and follow the instructions for pairing with your device.

  • Error Messages & Solutions:
    If you encounter any error messages on the LCD screen, please refer to the detailed error code section in the manual for specific solutions to each error.

  • What’s in the Box:
    The product package includes the main unit, charging cables, user manual, and any additional accessories as specified by the manufacturer.

  • Maintenance:
    Regular maintenance of the product includes keeping the ventilation openings clear, ensuring proper charging methods are used, and monitoring battery levels for optimal performance.

ATG-PS-04-3kW0 parameters

Product overview

LCD screen

  • Battery capacity: When ATG-PS-04-3kW0 is being charged, the SOC icon will flicker.
  • Wi-Fi connection status: The flickering icon indicates that ATG-PS-04-3kW0 is ready for pairing. The icon will keep flickering if a mobile phone and ATG-PS-04-3kW0 are connected by a hotspot. After the network connection succeeds, the icon will always be on. If the connection fails, the icon will be off.

Please refer to clause 5 for more details regarding the error message.

Use

On and off

  • Press the main power switch to turn on the device, then the screen will be lit and the main power indicator will enter the breathing light mode.
  • If no operation is performed to ATG-PS-04-3kW0 for hibernation state and the LCD will automatically turn off. When there is a load change or operation to ATG-PS-04-3kW0 the LCD screen will be automatically lit. Press the main power switch to turn on or turn off the LCD.
  • Press and hold the main switch will turn off ATG-PS-04-3kW0.
  • The default standby time is 2 hours. If other output power switches are not turned on and not any loads are connected, ATG-PS-04-3kW0 will automatically shut down after 2 hours. Standby time can be set on the APP.

AC charging

Quick charging technology is designed for AC charging. You can control the charging power via the AC charging speed switch. The slow charge mode is on by default when ATG-PS-04-3kW0 is turned on, and can be switched to quick charge mode by the button. Quick and slow charging mode switching can also be set by APP. If the current is continuously higher than 20A, the charging input port will start the self-protection function, and the charging overload protection switch will automatically trip. Press the charge overload protection switch to restore charging after confirming no fault.

Quick charge and slow charge can be switched by the button.

The charging power range can be adjusted by the APP.
Please use the standard AC charging Cable for fast charging. AC Charging Cable should directly plug into a 15A (or above) wall-mounted socket. We take no responsibility for any damage caused by using unofficial AC charging cable, and other failures to follow instructions.

PV charging

Solar charging cable (DC7909)

  • Please follow the user manual to connect the solar panels.
  • Before connecting the solar panel, check whether its output voltage is within SR03KWL-SG1- US specifications to avoid damage to ATG-PS-04-3kW0.

Car charging

ATG-PS-04-3kW0 can be charged by a car charging port. It should be charged after the car starts, so as to avoid the car battery loss and failure to start. At the same time, ensure a good connection between the car charging port and the cigarette lighter. We take no responsibility for any loss caused by improper operation.

Battery expansion

ATG-PS-04-3kW0 supports connection with 6 expansion battery packs at the same time for larger capacity. Please refer to the user manual of the battery pack for details.

Notes

  • Before connecting the battery pack, please make sure both ATG-PS-04-3kW0 and the battery pack are off.
  • After the battery pack is connected, check if the battery icon is shown in the displays of both ATG-PS-04-3kW0 and the battery pack.
  • While in charging, please do not connect or remove the battery pack. If the connection or need to connect or cloth gently and carefully. remove it, turn off ATG-PS-04-3kW0 prior to operation.
  • Please do not touch the metal terminals. If there is foreign matter on the metal terminals, clean it with a dry Scenarios of battery pack connection

Scenario 1

  • Turn off the power station and expansion the battery pack
  • Plug one end of the cable to the expansion port of the power station, and the other end to the Power Output of the battery pack.
  • After parallelization, press the power button of the power station to enable the power station and battery pack to show the current capacity. The power station shows the paralleled quantity, and capacity is expanded.
  • After parallelization, connect the ports of the power station for charging or discharging (refer to clauses 3.3, 3.4, 3.5 and 3.6).

Remark : There are + and ‒ symbols on battery packs and cables in case of reverse polarities.

Scenario 2

  1. Turn off the power station and expansion battery packs.
  2. Plug one end of cable #1 to the expansion port of the power station, the other end to the Power Output of battery pack #1. Plug one end of cable #2 to Power Input of battery pack #1, the other end to Power Output of battery pack #2. Plug one end of cable #3 to Power Input of battery pack #2, the other end to Power Output of battery pack #3. 6 battery packs can be parallelized at most.
  3. After parallelization, press power button of the power station to enable the power station and battery packs to show the current capacity. The power station shows the paralleled quantity, and capacity is expanded.
  4. After parallelization, connect ports of the power station for charging or discharging (refer to clause 3.3, 3.4, 3.5 and 3.6).

Remark : There are + and ‒ symbols on battery packs and cables in case of reverse polarities.

 APP

You can control and view information and data about this product by App.

UPS function

This product supports the UPS function. When you connect the electrical appliance with ATG-PS-04-3kW0 by AC cable, the output enables the appliance to work. In such case, power is from grid instead of a battery. When the power grid is off, the power station can switch to battery-supplying mode within 14mS. Such function is unprofessional UPS, which does not support switch in 0mS, so do not connect it to equipment with strict UPS requirements, such as data server and workstation or please confirm compatibility after tests, and suggest only using one device instead of multiple devices at the same time so as not to cause overload to the power station. We shall not be liable for abnormal work or data loss arising from an operation not following this user manual.

Error messages & solutions

If there is a warning occurs during the use of this product, and the warning icon still does not disappear after restarting the device, please stop using it immediately (do not try to charge or discharge). If none of the above information can solve the problem you encounter, please contact customer service for consultation.

What’s in the box

Disclaimer

Before using the power station ATG-PS-04-3kW0, please read this user manual to ensure understanding and proper use. After reading the user manual, please keep it well for future reference. Improper operation may cause serious injury to yourself or others, or result in product damage and property loss. Once using ATGPS- 04-3kW0, you are deemed to have understood and accepted all terms and contents herein. Users promise to be responsible for their actions and all consequences arising therefrom. We shall not be liable for any loss arising from user’s not following this user manual.
In compliance with laws and regulations, the company reserves the right to the final interpretation of this document and all related documents of this product. Subject to update, revision or termination without prior notice, please visit the official website for the latest product information.

ISED Statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic DevelopmentCanada’s licence-exempt RSS(s).

Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any int er ference, including int er ference that may cause undesired operation of the device.

This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body

FCC Statement
This device complies with Part 15 of the FCC Rules.

Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any int er ference received, including int er ference that may cause undesired operation.

2. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Note : This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates uses and can radiate radio f frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular institution. if this equipmemt does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the difference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected
  • Consult the dealer or an experienced radio/ TV technician for help.

The device has been evaluated to meet general RF exposure requirements. The devicecan be used in por t able exposure conditions without restriction. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body.

FAQs

1. What kind of battery is used?

Lithium iron phosphate battery (LiFePO ). 4

2. What equipment can be connected to the AC output ports?

The AC output has high rating power and maximum power, which enables it to supply power to most household appliances. Suggest checking the equipment power prior to connecting and make sure the power of all equipment is lower than the rated power.

3. How to know the supply time?

Time shows in the LCD, which can be referred to for estimation for equipment with stable power consumption.

4. How to know it is charging?

When in charge, the LCD shows the remaining charging time. The SOC flickers and input power is shown.

5. How to clean the unit?

Clean the unit with a dry, soft and clean cloth or tissue.

6. How to store the unit?

Turn it off, and keep it in a dry and ventilated place. Do not expose it close to water. For long-term storage, suggest discharge to 0% and charge to 100% every 3 months to extend the service life.

7. Can it be taken on board?

No.