ideal lux Carlton PL12 Ceiling Lamp Instruction Manual

June 11, 2024
ideal lux

ideal lux Carlton PL12 Ceiling Lamp

Product Specifications:

  • Model: Carlton PL12
  • Maximum Wattage: E14 max 12 x 40W
  • Voltage: 220~240V, 50/60 Hz
  • Color Options: CROMO – 8021696168937, ORO – 8021696213507

Product Usage Instructions

Installation:

**** The lighting fixture should be installed by a qualifiedelectrician. Follow the assembly instructions in numerical order.

Safety Instructions:

  • Ensure the power supply is switched off before installation or maintenance.
  • Avoid looking directly at the light source.
  • Use appropriate fixing accessories and comply with safety regulations.
  • Do not attempt to replace the LED light source.

Electrical Safety Classes:

  • Class I: Requires mandatory grounding for electrical safety.
  • Class II: Does not require grounding due to double insulation or reinforced insulation.
  • Class III: Operates at very low voltage (<50V) and does not require grounding.

Protection Against Solid Objects and Dust:

  • Protection against solid objects with diameters exceeding 50mm, 12mm, 2.5mm, and 1mm.
  • Protection against dust ingress, with some models offering total dust protection.

Frequently Asked Questions

Q: Can the LED light source be replaced?

A: No, the LED light source in this product is non-replaceable.

Q: What should I do if the lamp does not turn on?

A: In case the lamp fails to light up, replace the fuse within the fixture.

Q: Is grounding mandatory for this product?

A: Grounding is mandatory for Class I electrical safety but not required for Class II or Class III models.

Product Information

Ceiling lamp

E14 max 12 x 40W / 220~240V 50/60 H

  • 8021696168937 CROMO
  • 8021696213507 ORO

Symbol

Installation Instruction

FOLLOW THE ASSEMBLY INSTRUCTIONS BY READING THE NUMERICAL PROGRESSION THE LIGHTING FITTING SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN

SAFETY INSTRUCTIONS

  1. This fitting is produced and tested in accordance with the strictest European safety standards (EN 60.598-1).
  2. This fitting cannot be disposed of as household waste. For disposal information ask the local authorities about how to collect it.
  3. As indicated by specific regulations, the lighting fitting should be installed by a qualified electrician.
  4. If the external wire is damaged it has to be replaced exclusively by the manufacturer, distributoror by a qualified electrician.
  5. Always isolate power before commencing installation, maintenance or repair.
  6. The luminaire contains certain parts which can be very hot.
  7. Each material requires specific mounting accessories. Use screws and wall plugs suitable for the material to which they are fastened. Those included may be unsuitable.
  8. Always tighten the screws firmly to avoid contact problems.
  9. This fitting should only be installed indoors.
  10. Luminaires are not suitable for recessed on normally flammable surfaces.
  11. Luminaire is not suitable for direct mounting on normal flammable surfaces.
  12. This fitting is only suitable for fixing to the ceiling.
  13. This fitting is only suitable for fixing to the wall.
  14. The weight of the lamp has to be supported by the chain. Adjust the length of the electric wire so that it is longer than the chain.
  15. Only use lamps which do not exceed the maximum specified wattage.
  16. Always observe the minimum distance between the lamp and the surface being lit, as shown in the icon. The lamp can cause a fire if the minimum distance is not observed.
  17. Auto-protected bulb. Only use bulbs marked with this symbol. Halogen bulbs get very hot. Wait until they cool down before replacing.
  18. Cracked or broken safety glass has to be replaced immediately. Use only manufacturer approved parts complying with regulations.
  19. Light source with not-substitutable light emitting diode (LED). Do not disassemble the products the diodes can damage the eyes. Do not immerse in water. Wipe with a damp cloth. Do not use solvents or strong detergents.
  20. This fitting is equipped with a fuse. If the lamp is out of order, replace the internal fuse.
  21. Class I Electrical safety is guaranteed by the main insulation and an additional protective conduc- tor (earthing) connected with the metal frame of the lamp. Earthing is obligatory.
  22. Class IL electrical safety is guaranteed by the main insulation and a double or reinforced insulation. Earthing not necessary.
  23. Class Ill Electrical safety guaranteed by very low power supply (less than 50 Volt). Earthing excluded.
  24. Not protected.
  25. Protected against solid objects greater than 50 mm.
  26. Protected against solid objects greater than 12 mm.
  27. Protected against solid objects greater than 2,5 mm.
  28. Protected against solid objects greater than 1mm.
  29. Dust protected.
  30. Totally protected against dust infiltration.
  31. Not protected.
  32. Protected against vertically falling water drops.
  33. Protected against water drops falling with a maximum angle of 15° to the vertical axis.
  34. Protected against rain.
  35. Protected against splashing water.
  36. Protected against water jets.
  37. Protected against strong water jets.
  38. Protected against temporary immersion.
  39. Protected against prolonged immersion.
  40. Luminaire not suitable for covering with thermally insulating material.
  41. Caution, risk of electric shock.
  42. Do not stare at the operating light source.

Contact

IDEAL LUX s.r.l.

IDEAL LUX Warehouse

  • Via delle Industrie, 8/D
  • 30036 Santa Maria di Sala (Venezia)
  • 8.00 – 12.00 / 13.30 – 17.00

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals