Homedics UHE-CM55 Cool Mist Ultrasonic Humidifier Instruction Manual and Warranty Information
- June 8, 2024
- Homedics
Table of Contents
Homedics UHE-CM55 Cool Mist Ultrasonic Humidifier Instruction Manual and Warranty Information
IMPORTANT SAFETY INSTRUCTIONS:
WHEN USING ELECTRICAL PRODUCTS, ESPECIALLY WHEN CHILDREN ARE PRESENT,
BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING
THE FOLLOWING:
READ ALL INSTRUCTIONS BEFORE USING
DANGER – TO REDUCE THE RISK OF ELECTRIC SHOCK:
-
Always place humidifier on a firm, flat surface. A waterproof mat or pad is recommended for use under the humidifier. Never place it on a rug or carpet, or
on a finished floor that may be damaged by exposure to water or moisture. -
Always unplug the unit from the electrical outlet immediately after using and before cleaning
-
DO NOT reach for a unit that has fallen into water. Unplug it immediately.
-
DO NOT use while bathing or in the shower.
-
DO NOT place or store the unit where it can fall or be pulled into a tub or sink.
-
DO NOT place or drop into water or other liquids.
-
DO NOT use water above 86° Fahrenheit.
WARNING – TO REDUCE THE RISK OF BURNS, ELECTRIC SHOCK, FIRE
OR INJURY TO PERSONS:
-
A unit should never be left unattended while plugged in.
-
Close supervision is necessary when this unit is used by or near children, invalids, or disabled persons.
-
Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by HoMedics; specifically any attachments not
provided with this unit. -
EVER drop or insert any object into any opening.
-
DO NOT operate where aerosol (spray) products are being used, or where oxygen is being administered.
-
Always hold the water tank firmly with both hands when carrying a full tank of water.
-
NEVER use the humidifier in an environment where explosive gasses are present.
-
DO NOT place the humidifier near heat sources, such as a stove, and do not expose the humidifier to direct sunlight.
-
DO NOT carry this unit by the power cord or use the power cord as a handle.
-
To disconnect, turn all controls to the “off” position, then remove the plug from the outlet.
-
This unit is designed for personal, non-professional use only.
-
DO NOT use outdoors. For indoor use only.
SAVE THESE INSTRUCTIONS
CAUTION – PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE
OPERATION
-
Never cover the unit while it is operating.
-
Always keep the cord away from high temperature and fire.
-
If the cord sustains damage, you must stop using this product immediately and contact HoMedics consumer relations (see Warranty section for consumer
relations contact information). -
Perform regular maintenance on the ultrasonic membrane.
-
Never use detergent to clean the ultrasonic membrane.
-
Never clean the ultrasonic membrane by scraping with a hard object.
-
Do not attempt to adjust or repair the unit. Servicing must be performed by professional or qualified personnel.
-
Stop using this unit if there is an unusual noise or smell.
-
Unplug this unit when not in use for a long period of time.
-
Do not touch the water or any parts of the unit that are covered by water while the unit is on or plugged in.
-
Never operate without water in the tank.
-
Only use water in the tank.
-
Never use any additive to the water.
-
Do not wash, adjust, or move this unit without first unplugging it from the electrical outlet.
-
Keep this unit out of reach of children. Do not allow children to use this unit without supervision.
Unique Features and Specifications
Ultrasonic Technology
This humidifier uses ultrasonic high frequency technology to convert the
water into 1–5 million
super particles that are dispersed into the air evenly.
Night Mode
Turns off display, mutes buttons, and sets humidistat to 40%.
Programmable Humidistat
Customize the level of humidity.
Built-In Timer
Programmable time, up to 9 hours.
Auto Shut-Off Protection
When the tank is empty the unit will shut off automatically.
Voltage Watts Capacity
120V/60Hz 25 1.3 gallon – 4.9 liters
Run Time: 48 hours
Run time is calculated based on using cool water and setting the mist level
between the low and medium settings. Based on the natural humidity level in
your home, the temperature of water you use, and the mist level setting you
choose, you may experience longer or shorter run times.
Cool Mist Ultrasonic Humidifier
Figure 1
CAUTION: This appliance has a polarized plug (one blade wider than the other).
To reduce the risk of shock, this plug is intended to fit only one way
in a polarized outlet. If the plug does not fit fully in the outlet, reverse
the plug. If it still does not fit, contact a qualified electrician.
DO NOT attempt to defeat this safety feature. To do so could result in an
electric shock hazard.
Figure 2
Power Button
Plug unit into a 120 volt AC electrical outlet. Press the POWER BUTTON ( )
once to turn the humidifier on.
ATTENTION: When the water in the tank is almost empty, the humidifying
function will power off to indicate to the user to refill the tank.
Dual Swivel Mist Spout
This unit has a dual swivel mist spout that allows you to direct the mist
360°. Simply adjust the outlets to aim the mist in whichever direction you
want.
Aroma Therapy
This humidifier includes an aroma therapy chamber. To access the aroma therapy
feature, remove the tank and locate the sponge. Drip a few drops of your
favorite aroma oil onto the sponge for a gentle aroma therapy effect.
Mist Adjustment Setting
Mist adjusts from MINIMUM ( 1 ) mist to MAXIMUM ( 3 ) mist. To increase the
mist output, press the MIST button. To decrease mist output, cycle through all
three mist settings.
Night Mode
Press the TIMER ( ) button for three seconds to turn off all display LED’s. To
turn night mode off, and control lights on, press and hold TIMER ( ) button
for three seconds.
Programmable Humidistat
This unit has a programmable humidistat that can be set in 5% increments from
35% – 60% humidity.
To program the humidity level, press the HUMIDISTAT button and cycle through
selections. After selection is made display will revert to showing existing
RH%. After 60% screen will display “–” and clear the program. Once the
programmed humidity level is reached, the unit will stop misting until the
humidity level drops below the programmed level. Then it will resume misting.
Timer
The timer will cycle through the following settings: 1 hour, 2 hours, 4 hours,
6 hours, 8 hours, 9 hours, and “0”. Press the TIMER button to activate the
timer. The timer setting indicator will read “1”. To select the desired timer
setting, keep pressing the TIMER button until the desired timer setting is
lit. To turn the timer off, press the TIMER button until “0” is displayed,
after 2 seconds the timer will turn off.
Using the Remote Control
BEFORE FIRST USE, REMOVE PLASTIC PULL TAB FROM BATTERY COMPARTMENT.
Battery Installation
One CR2025 3V battery is included with the remote control. To change the
battery, remove the battery door at the back of the remote by squeezing the
tab and pulling the
door away from the back of the remote. Please insert the battery into the
remote with the positive side up as shown on the drawer.
NOTE: Always keep the battery and remote control out of the reach of
children.
BATTERY NOTE
- If the unit is not going to be used for a long period of time, remove batteries to prevent damage due to possible battery leakage.
- Clean the battery contacts and also those of the device prior to battery installation.
- Remove used batteries promptly.
- Dispose of properly in accordance with all state, province, and country regulations.
- Do not dispose of batteries in fire. Batteries may explode or leak.
- Use only the size and type of batteries specified.
- When installing batteries, observe proper polarity +/-. Improper installation of batteries may cause damage.
Figure 3
How to Fill
CAUTION: Before filling unit with water, turn the power off and unplug
the unit from the outlet.
Note: Always use two hands to carry the water tank.
-
Grasp tank handle and lift up from humidifier base. (Fig. 3)
Figure 3
NOTE: Mist nozzle is removable for cleaning. Be sure to remove
mist nozzle before turning tank upside down for filling. -
Turn the tank upside down—remove the tank cap by turning it counter-clockwise. (Fig. 4)
Figure 4 -
Fill the water tank with clean, cool (not cold) water. We recommend using distilled water if you live in a hard water area. (Fig. 5)
Figure 5 -
Replace the tank cap by turning clockwise until tight. (Fig. 6)
Figure 6
-
NOTE: It is normal to have a small amount of water in the base during and after use.
About White Dust:
Use of high mineral content hard water may cause a white mineral residue to
accumulate on surfaces in the room near the humidifier. The mineral residue is
commonly called “white dust.” The higher the mineral content (or, the harder
your water is), the greater the potential for white dust. The white dust is
not caused by a defect in the humidifier. It is caused only by minerals
suspended in the water.
How and Why To Use Demineralization Cartridges:
The HoMedics demineralization cartridge will help reduce the potential for
white dust, a deposit of minerals left behind from using hard water in your
humidifier. The cartridge should be replaced every 30 – 40 fillings. The
cartridge may need to be replaced more often if you are using very hard water.
Replace the cartridge when you notice an increase in white dust build-up. If
white dust still forms around the humidifier after a new cartridge has been
installed, consider using distilled water. To purchase new demineralization
cartridges, model # UHE-HDC4, go back to the retailer (where you purchased
your humidifier), or visit www.homedics.com
If you live in an area with hard water, or use a water softener, we recommend using distilled water for better results from your humidifier. Never use water softening additives in your humidifier.
Installation Instructions
- Remove demineralization cartridge from packaging and let it soak in water for 10 minutes.
- Remove the tank from humidifier base and turn it over.
- Unscrew the tank cap by turning the cap counter-clockwise.
- Fill the tank with water as shown in the How to Fill section of the instructions included with your humidifier.
- Add the soaked demineralization cartridge into the tank.
- Replace the tank cap by turning clockwise.
- Place the tank back on the base.
Demineralization Cartridge
Cleaning and Care Troubleshooting
CAUTION: Before cleaning the unit, turn power off and unplug unit from
the outlet.
To Clean the Tank
Remove the water tank from the humidifier base by lifting it from the main
unit. Unscrew the tank cap and rinse inside the tank with clean water. To
remove any scale or build up, use a 50/50 mixture of vinegar and lukewarm
water to clean the inside of the tank. (Fig. 8) Suggestion: Clean the
water tank once every two to three
weeks, depending on your water conditions.
Figure 8
To Clean the Ultrasonic Membrane
Pour a 50/50 mixture of vinegar and water on the surface of the ultrasonic
membrane, then soak for five minutes. Brush
clean with a soft-bristle brush (not included) and rinse. NEVER touch the
ultrasonic membrane with your fingers as the natural oils in skin can damage
the membrane. (Fig. 9)
Suggestion: Clean the membrane once every two to three weeks, depending on
your water conditions.
NOTE: Never submerge the base in water or any liquid
Figure 9
To Clean the Surface
Clean the surface of the unit with a clean damp soft cloth as often as needed.
(Fig. 10)
Figure 10
Troubleshooting
FCC Disclaimer
NOTE: This product has been tested and complies with the requirements for
Federal Communication Commission, Part 18. Although this product is tested and
complies with FCC, it may interfere with other devices. If this product is
found to interfere with another device, separate the other device and this
product. Conduct only the user maintenance found in this instruction manual.
Other maintenance and servicing may cause harmful interference and can void
the required FCC compliance.
Limited One Year Warranty
HoMedics sells its products with the intent that they are free of defects in
manufacture and workmanship for a period of one year from the date of original
purchase, except as noted below. HoMedics warrants that its products will be
free of defects in material and workmanship under normal use and service. This
warranty extends only to consumers and does not extend to Retailers.
To obtain warranty service on your HoMedics product, contact a consumer
relations representative for assistance. Please make sure to have the model
number of the product available.
HoMedics does not authorize anyone, including, but not limited to, Retailers,
the subsequent consumer purchaser of the product from a Retailer or remote
purchasers, to obligate HoMedics in any way beyond the terms set forth herein.
This warranty does not cover damage caused by misuse or abuse; accident; the
attachment of any unauthorized accessory; alteration to the product; improper
installation; unauthorized repairs or modifications; improper use of
electrical/power supply; loss of power; dropped product; malfunction or damage
of an operating part from failure to provide manufacturer’s recommended
maintenance; transportation damage; theft; neglect; vandalism; or
environmental conditions; loss of use during the period the product is at a
repair facility or otherwise awaiting parts or repair; or any other conditions
whatsoever that are beyond the control of HoMedics.
This warranty is effective only if the product is purchased and operated in
the country in which the product is purchased. A product that requires
modifications
or adoption to enable it to operate in any other country than the country for
which it was designed, manufactured, approved and/or authorized, or repair of
products damaged by these modifications is not covered under this warranty.
THE WARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND EXCLUSIVE WARRANTY. THERE
SHALL BE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY
OF MERCHANTABILITY OR FITNESS OR ANY OTHER OBLIGATION ON THE PART OF THE
COMPANY WITH RESPECT TO PRODUCTS COVERED BY THIS WARRANTY. HOMEDICS SHALL HAVE
NO LIABILITY FOR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES. IN NO EVENT
SHALL THIS WARRANTY REQUIRE MORE THAN THE REPAIR OR REPLACEMENT OF ANY PART OR
PARTS WHICH ARE FOUND TO BE DEFECTIVE WITHIN THE EFFECTIVE PERIOD OF THE
WARRANTY. NO REFUNDS WILL BE
GIVEN. IF REPLACEMENT PARTS FOR DEFECTIVE MATERIALS ARE NOT AVAILABLE,
HOMEDICS RESERVES THE RIGHT TO MAKE PRODUCT SUBSTITUTIONS IN LIEU OF REPAIR OR
REPLACEMENT.
This warranty does not extend to the purchase of opened, used, repaired,
repackaged and/or resealed products, including but not limited to sale of such
products on Internet auction sites and/or sales of such products by surplus or
bulk resellers. Any and all warranties or guarantees shall immediately cease
and terminate as to any products or parts thereof which are repaired,
replaced, altered, or modified, without the prior express and written consent
of HoMedics.
This warranty provides you with specific legal rights. You may have additional
rights which may vary from country to country. Because of individual country
regulations, some of the above limitations and exclusions may not apply to
you.
For more information regarding our product line in the USA, please visit:
www.homedics.com. For Canada, please visit: www.homedics.ca.
Read More About This Manual & Download PDF:
Homedics UHE-CM55 Cool Mist Ultrasonic Humidifier Instruction Manual and
Warranty Information – Download [optimized]
Homedics UHE-CM55 Cool Mist Ultrasonic Humidifier Instruction Manual and
Warranty Information – Download