BFT XPASS B 330-1200 Automatic Hydraulic Anti-Terrorism Crash Instruction Manual

June 3, 2024
BFT

BFT XPASS B 330-1200 Automatic Hydraulic Anti-Terrorism Crash Instruction Manual

The INSTALLATION, USE AND MAINTENANCE handbook is for installers, users and maintenance engineers.

Please read it carefully before installing the appliance, before using it and before routine or extraordinary maintenance work.

Operations that, if not carried out correctly, can be risky, are indicated with the following symbols : The manufacturer is not liable for injury to people or animals or damage to things in the case of applications that exceed the limits specified on the enclosed technical data sheet or by a use different from what the appliance has been designed.

GENERAL

The deterrent bollard is the ideal solution for managing vehicle traffic in compliance with modern urban furnishing requirements. It can be used to control entrances or to safeguard private areas in total safety

TECHNICAL SPECIFICATIONS

  • Power: 230 Vic ± 10% ; 50÷60 Hz; 500 W
  • Working frequency: 3.000 / 24
  • Protection level: IP67
  • Control unit: PERSEO CBD / PERSEO CBE
  • Working temp: 40 +60 °C
  • Working time: 6,5 s.
  • Weight: 260 kg
OVERALL SIZE DIMENSIONS

Product Dimensions

LAYOUT

Product Dimensions

A Road surface
B Cement RcK25
C Sheathing Ø50
D Connection to the sewer network Ø100
--- ---
E Fine sand
F Pebble gravel
G Ø20 Fe B44K (not provided)
WIRING NOTE

Product Overview

1 Single-phase line H05VV 2 x 1,5 + T
2 Receiver 4 x 0,5
3 SOS 4 x 0,5
4 Lampe 2 x 0,5
5 Key selector 2 x 0,5
6 XPASS B 800C SD Cable supplied by us
7 Detector-Request instruction Twisted cable
8 Transmitter photocell 2 x 0,5
9 Receiver photocell 4 x 0,5
10 Traffic light 3 x 0,5 + T

Installation Instruction
Installation Instruction
Installation Instruction
Installation Instruction

DRAINAGE

Ensure that the soil has a adequate water absorption by entering about 40 liters of water and checking that the emptying takes place in less than 30 minutes; otherwise realize the drainage of water through pipes connected to every single manhole and connected to the sewage network with siphon, or a collecting sump with a drainage system of water.

Installation Instruction
Installation Instruction
Installation Instruction
Installation Instruction
Installation Instruction
Installation Instruction
GENERAL SAFETY

  • For safety reasons and to comply with current standards, we recommend using the control unit.
  • The construction components of this product must comply with the following European Directives: 2004/108/CEE, 2006/108/EEC, 2006/42 EEC and subsequent amendments. As for all non-EEC countries, the above-mentioned standards as well as the current national standards should be respected in order to achieve a good safety level.
  • The Company declines all responsibility for any consequences resulting from failure to observe Good Technical Practice when installing the device described in the present manual.
  • Do not install the product in potentially explosive atmosphere or wherever there is a fi re risk.
  • Disconnect the electrical supply before carrying out any work on the installation. Also disconnect any buffer batteries, if fitted.
  • Fit an omnipolar or magnetothermal switch on the mains power supply, having a contact opening distance equal to or greater than 3,5 mm. Also fi t an adequate cut-out device for the buff er batteries.
  • Check that a diff eventual switch with a 0.03A threshold is fitted just before the power supply mains.
  • Check that earthing is carried out correctly.
  • Installation must be carried out using the safety devices and controls prescribed by the EN 12978 Standard.
  • Fit all the safety devices (photocells, electric edges etc.) which are needed to protect the area from any danger caused by squashing, conveying.
  • Position at least one luminous signal indication device (blinker) where it can be easily seen, and fi x a Warning sign next to the structure.
  • Only use original parts for any maintenance or repair operation. The Company declines all responsibility with respect to the automation safety and correct operation when other producers’ components are used.
  • Do not modify the automation components, unless explicitly authorised by the Company.
  • Scrap packing materials (plastic, cardboard, polystyrene etc) according to the provisions set out by current standards. Keep nylon or polystyrene bags out of children’s reach.
  • Anything which is not expressly provided for in the present instructions, is not allowed.
  • Instruct the product user about the control systems provided and the manual opening operation in case of emergency.
  • Do not allow persons or children to remain within the automation operation area.
  • Keep radio control or other control devices out of children’s reach, in order to avoid unintentional automation activation.

USE

  • Consult the control unit’s installation and operating manual.
  • Follow the instructions given in point 7 to release in the case of emergency

ROUTINE MAINTENANCE (EVERY 6 MONTHS)

  • Maintenance must be carried out by qualifi ed personnel only.
  • Visually check the overall state of wear and tear of the external parts of the deterrent bollard.
  • Make sure the rear-refl ecting fi lm is not worn.
  • Make sure the lights work.
  • Make sure the emergency maneuver is working properly.
  • Make sure the control unit and safety devices are in proper working order.

UNITED KINGDOM
BFT AUTOMATION UK LTD
Stockport, Cheshire, SK7 5DA
www.bft.co.uk

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BFT User Manuals

Related Manuals