GARDENA 9010 Surface Water Pump Instruction Manual

June 9, 2024
Gardena

GARDENA 9010 Surface Water Pump Instruction Manual

Original instructions.

This product may be used under supervision, or if instruction regarding the safe use of the product has been provided and the resulting dangers have been understood, by children aged 8 and above, as well as by persons with physical, sensory or mental disabilities or a lack of experience and knowledge. Children must not be allowed to play with the product. Cleaning and user maintenance must not be performed by children without supervision. The use of this product by young people under the age of 16 is not recommended.

Never operate the product when you are tired, ill or under the influence of alcohol, drugs or medicine.

Intended use:
The GARDENA Garden Pump is intended for pumping ground water and rain water, tap water and water containing chlorine in private domestic gardens and allotments.

Liquids to be pumped:
The GARDENA Garden Pump must only be used to pump water.
When the pump is used for pressure boosting, the maximum permissible internal pressure of 6 bar (on the delivery side) must not be exceeded.
The increased delivery pressure and the pump pressure have to be added together.
– Example: Pressure at the tap = 2.5 bar, max. pressure of the Garden Pump Art. 9010 = 3.5 bar, total pressure = 6.0 bar.
The product is not intended for long term use (continuous circulation operation).

DANGER! Risk of injury!

  • The pump must not be used for the delivery of salt water, muddy water, corrosive, easily inflammable or explosive liquids (e. g. petrol, paraffin, thinners), oil, heating oil or foodstuffs.

1. SAFETY INSTRUCTIONS

IMPORTANT!
Read the operator’s manual carefully before use and keep for future reference.
Symbols on the product:

Read operator’s manual.

General safety warnings
Electrical safety

DANGER! Electric shock!
Risk of injury due to electric current.

  • The product must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.

DANGER! Risk of physical injury!
Risk of injury due to electric current.

  • Disconnect the product from the mains before you maintain or replace parts. Thereby the disconnected socket must be in the visual range.

Safe operating practices
The water temperature should not exceed 35 °C.
The pump must not be used when people are in the water.
Pollution of the liquid could occur due to leakage of lubricants.

Circuit breaker
Thermal protection switch:
In the event of an overload, the pump is switched off by the built-in thermal motor protection. After sufficient cooling of the motor, the pump is operational again.

Additional safety warnings
Electrical safety

DANGER! Cardiac arrest!
This product makes an electromagnetic field while it operates. This field may under some conditions interfere with active or passive medical implants. To decrease the risk of conditions that can possibly injure or kill, we recommend persons with medical implants to speak with their physician and the medical implant manufacturer before you operate the product.

Cables
If extension cables are used, these must comply with the minimum cross- sections in the table below:

DANGER! Electric shock!
Risk of injury due to electric current.

  • Disconnect the product from the mains before you put it into storage, maintain or troubleshoot.

The pump must be located on solid, even ground, protected from flooding. Take care that the pump cannot fall into water. Position the pump at a safe distance (min. 2 m) from the liquid to be pumped. As an additional safety device an authorised safety switch can be used.

Please ask your electrician for his advice.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Protect the mains plug and the mains power cable from heat, oil and sharp edges.
Do not use the power cable for carrying the pump or for unplugging.
Protect the pump from rain. Don’t use the pump in wet or moist areas.
Please regularly check the connecting line.
Before using, always subject the pump (especially the power cables and the power connections) to a visual inspection.
A pump which is damaged must not be used. In the event of damage, have the pump checked by GARDENA Service.
When using our pumps with a generator, the warnings of the generator manufacturer must be observed.

Personal safety
DANGER! Risk of suffocation!
Small parts can be easily swallowed. There is also a risk that the polybag can suffocate toddlers. Keep toddlers away when you assemble the product.

DANGER! Risk of injury due to hot water!
If the pump is operated for prolonged periods of time (> 5 min.) with the delivery side closed, the water in the pump may heat up so that there is a risk of scalding yourself with hot water.

  • The pump should not run against the closed delivery side for more than 5 minutes.

  • If the water supply on the intake side of the pump fails, the water in the pump can heat up so that if water emerges, injuries could be caused by the hot water.

  • Disconnect the pump from the mains via the main circuit breaker, let the water cool and secure the suction-side water supply before putting into operation again.
    When connecting the pump to the water supply system, the country-specific sanitary regulations must be observed to prevent water not of drinking water quality being drawn back in.

  • Please consult a specialist for sanitary installations.
    In order to avoid dry-running of the pump, take care that the end of the suction hose is always submerged into the liquid.

  • Before each operation, fill the pump to overflowing with approx. 2 to 3 l of the liquid to be pumped!
    Sand and other abrasive substances cause increased wear and reduce the pump’s output.

  • Use a pump pre-filter for pumping sandy liquids.
    Pumping dirty water, e.g. stones, pine needles etc., can cause damage to the pump.

  • Do not pump dirty water.

2. ASSEMBLY

DANGER! Risk of injury!
Injury when the product starts accidentally.

  • Disconnect the product from the mains before you assemble the product.

To set up the pump:
The site must be firm and solid in order to ensure safe and sturdy operating conditions for the pump.

  • Position the pump at a safe distance (min. 2 m) from the water.

The pump must be installed in a location with low air humidity and sufficient ventilation in the area of the ventilation slots. It must be at a distance of at least 5 cm from the walls. Dirt (e. g. sand or soil) must not be sucked in through the ventilation slots.
The plastic connection pieces on the intake and delivery sides may only be tightened by hand.

To connect the hose to the suction side [ Fig. A1 ]:
Don’t use any hose quick connection system fittings on the suction side!

  • A vacuum-resistant suction hose must be used, e. g. GARDENA Suction

Unit, Art. 1411 or GARDENA Bore Hole Suction Hose Art. 1729.
In order to reduce the suction time, it is advisable to use a suction hose with backflow preventer avoiding automatic draining of the suction hose when the pump has been switched off.

  1. Screw the pump connection piece (2) into the connector on the suction side (1).
  2. Connect the vacuum-resistant suction hose (3) airtight to the pump connection piece (2) of the pump.
  3. For suction heights exceeding 4 m: Also fix the suction hose (3) (e. g. by fastening it to a wooden post).

This relieves the pump of the weight of the suction hose.

To connect the hose to the pressure side [ Fig. A2 ]:
The pump connection (4) is equipped with a 33.3 mm (G 1″) internal thread.
E. g. a GARDENA pump connection piece Art. 1745 is required for the GARDENA Connection System (included in scope of delivery).
19 mm (3/4″) / 16 mm (5/8″) and 13 mm (1/2″) hoses can be connected via the GARDENA Connection System.

Optimised use of the pump capacity is achieved by connecting 19 mm (3/4″) hoses with e. g.

  • GARDENA Pump Connection Set Art. 1752, or by connecting 25 mm (1″) hoses with
  • GARDENA Quick Thread Coupling with external thread Art. 7115 / Quick Coupling Hose Connector Art. 7103.
  1. Only for Art. 9014: Use sealing tape (P) on the external thread of the pump connection piece.
  2. Screw the pump connection piece (2) into the connector on the delivery side (4).
  3. Connect the pressure hose (5) to the pump connection piece (2).

If more than one hose /accessory is connected simultaneously, we recommend using the
– GARDENA 2- or 4-Channel Water Distributor Art. 8193 / 8194, GARDENA Twin-Tap Connector Art. 940

which can be screwed directly onto the pump connection piece (2).

3. OPERATION

DANGER! Risk of injury!
Injury when the product starts accidentally.

  • Disconnect the product from the mains before you connect, adjust or transport the product.
    To pump water [ Fig. O1 / O2 ]:

CAUTION! Dry-Running of the pump!

  • Fill the pump with water up to the overflow (approx. 2 to 5 l) before each start-up.
  1. Unscrew the screw fitting (6) of the filler neck (7) by hand.
  2. Fill the pump via the filler neck (7) to overflowing with approx. 2 to 5 l of water.
  3. Tighten the screw fitting (6) of the filler neck (7) by hand (do not use pliers).
  4. Open any shut-off valves in the delivery line (accessories, water stop, etc.).
  5. Drain remaining water in pressure hose (5) so that air can escape during the suction process.
  6. Connect the pump to the mains.
  7. Lift and hold the delivery hose (5) at least 1 m vertically above the pump, press the On / Off switch (8) and wait until the pump has primed.
  • If the pump does not deliver water after approx. 5 minutes, switch off the pump (press On / Off switch (8)) (see 6. TROUBLESHOOTING).

The specified maximum self-priming suction height of 7 m is reached only if the pump is filled via the filler neck (7) up to the overflow and if, while doing so and during the self-priming, the delivery hose (5) is held up sufficiently high to prevent any water escaping from the pump via the delivery hose (5).

Rust formation: The pump Art. 9014 has a cast iron housing. After contact with water, rust will form (this does not damage the pump and is not covered by the warranty). Therefore rusting water may initially escape after switching on the pump.

4. MAINTENANCE

DANGER! Risk of injury!
Injury when the product starts accidentally.

  • Disconnect the product from the mains before you maintain the product.
    To flush the pump:

After pumping chlorinated water, the pump must be flushed.

  1. Pump lukewarm water (max. 35 °C), possibly adding a mild cleaning agent (e. g. detergent) until the pumped water runs clear.
  2. Remove residuals according to the waste disposal laws applicable in your area.

5. STORAGE

To put into storage [ Fig. S1 ]:
The pump is not frost-proof!
The product must be stored away from children.

1. Disconnect the pump from the mains.
2. If applicable, close all the shut-off devices on the intake side.
3. Open all the tapping points.
The pressure side is depressurized.
4. Open the screw fitting (6) of the filler neck (7) and the water drain screw (9).
The Garden Pump drains.
5. Store the pump in a dry, enclosed and frost-free place.

6. TROUBLESHOOTING

DANGER! Risk of injury!
Injury when the product starts accidentally.

  • Disconnect the product from the mains before you troubleshoot the product.
    To loosen the impeller [ Fig. T1 ]:
    An impeller blocked by dirt can be freed again.

Turn shaft of the impeller (10) with a screwdriver.
This will loosen the stuck impeller.

NOTE: For any other malfunctions please contact the GARDENA service department.
Repairs must only be done by GARDENA service departments or specialist dealers approved by GARDENA.

7. TECHNICAL DATA

8. ACCESSORIES / SPARE PARTS

9. WARRANTY / SERVICE

9.1 Product registration:
Please register your product at gardena.com/registration.

9.2 Service:
Please find the current contact information of our service on the back page and online:
• United Kingdom:
https://www.gardena.com/uk/support/advice/contact/
• Australia: https://www.gardena.com/au/support/advice/contact/
• New Zealand: https://www.gardena.com/nz/support/advice/contact/
• South Africa: https://www.gardena.com/za/support/contact/

10. DISPOSAL

10.1 Disposal of the pump:
(according to Directive 2012/19/EU)
The product must not be disposed of to normal household waste. It must be disposed of in line with local environmental regulations.

IMPORTANT!
v Dispose of the product through or via your municipal recycling collection centre.

Performance characteristics

EC Declaration of Conformity
The undersigned hereby certifies as the authorized representative of the manufacturer, GARDENA Germany AB, PO Box 7454, S-103 92, Stockholm, Sweden, that, when leaving our factory, the unit(s) indicated below is / are in accordance with the harmonised EU guidelines, EU standards of safety and product specific standards. This certificate becomes void if the unit(s) is / are modified without our approval.

Description of the product: Garden Pump

Product type:

GP 3000/4 BASIC
GP 3700/4 BASIC
GP 3700/4 P BASIC

EC-Directives:

2011/65/EU
2014/30/EU
2014/35/EU
2000/14/EG

Article number:

9010
9014
9015

GARDENA Technical

Conformity Assessment
Procedure:
according to 2000/14/EC
Art.14 Annex V

Documentation

Harmonisierte EN-Normen

EN 60335-1
EN 60335-2-41
EN ISO 12100

Noise level:

Art. 9010: 77 dB(A) / 80 dB(A)
Art. 9014: 77 dB(A) / 80 dB(A)
Art. 9015: 75 dB(A) / 78 dB(A)

Year of CE marking: 2021

Ulm, 01.02 2022

Authorised representative

Canada / USA
GARDENA Canada Ltd.
125 Edgeware Road
Unit 15 A
Brampton L6Y 0P5
ON, Canada
Phone: (+1) 905 792 93 30
gardena.customerservice@husqvarnagroup.com

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals