TYPE: STRAIGHT CENTRIFUGAL
MOTOR: NEMA C FACE, 56J
HORSEPOWER: 3 HP (3450)
INLET : 2″ FNPT AND BUTTRESS THREAD PORTS
DISCHARGE: 2″ FNPT AND BUTTRESS THREAD PORTS
MATERIAL: 40% GLASS-FILLED POLYPROPYLENE
HARDWARE: STAINLESS STEEL
OPTIONS: SALTWATER SERVICE
ACCESSORIES: 90 CUBIC INCH STRAINER BASKETS (1.5″ & 2″) 500 CUBIC INCH STRAINER BASKET (2″) SWING CHECK VALVES (1.5″, 2″, 3″)

*MOTORS ARE SUBJECT TO CHANGE DUE TO AVAILABILITY OR SPECIFICATION REQUIREMENTS.

Model 11200PWR81 13200PWR81
INLET 2″ 2″
DISCHARGE 2″ 2″
MAX FLOW (gph) 11160 13200
MAX HEAD (feet) 80.8′ 81.7′
MAX POWER (watts) 2162 2595
MAX CURRENT (amps) 9.6 11.5
VOLTS 230 230
MOTOR HP 3 3
MOTOR ENCLOSURE TEFC TEFC
IMPELLER 6 7

Read this manual completely before you install or operate your new pump. This is an external “out-of-pond” pump.
It is not submersible. Do not allow this pump to become submerged. Never run dry. Maximum case pressure – 65 PSI.

We congratulate you on your choice of the Sequence® Power 4000 Centrifugal Pump. It has been carefully designed using the advantages of today’s technology and carefully constructed to give you the dependability of yesterday. To insure proper performance, we urge you to carefully follow the instructions in this manual. If you have any questions, please call your supplier for assistance or visit www.mdminc.com/support.

INSTALLATION

Please read carefully. When properly installed the Sequence® Power 4000 will provide dependable trouble-free service.

  1. Locate the pump as near the water source as possible. A flooded suction situation is preferred. The pump is not self-priming, therefore, if the fluid level is below the pump, a swing check valve must be installed and the pump primed prior to start-up (Figure 1).

  2. Mount motor base to a secure, immobile foundation.

  3. Use only plastic fittings on both the intake and discharge ports. Seal pipe connections with Teflon® paste. These fittings should be self-supported and in
    neutral alignment with each port (i.e. Fittings must not be forced into alignment which may cause premature line failure or damage to the pump volute). For non-flooded installations, a strainer basket and check valve are recommended.

  4. Never restrict the intake. Keep both input and discharge lines as free of elbows and valves as possible. Always use pipe of adequate diameter. This will reduce friction losses and maximize output.
    SEQUENCE Power 4000 Pump INSTALLATION 1

WARNING: ALWAYS SHUT OFF ELECTRICAL POWER BEFORE INSTALLATION AND / OR SERVICING THIS PUMP. ALL ELECTRICAL WIRING SHOULD MEET STATE AND LOCAL ORDINANCES. IMPROPER WIRING MAY NOT ONLY BE A SAFETY HAZARD BUT MAY PERMANENTLY DAMAGE THE MOTOR AND/OR PUMP. 230V 50HZ MOTORS ARE AVAILABLE. CONTACT YOUR SUPPLIER FOR INFORMATION. ****

ELECTRICAL HOOK-UP

  1. Check that supply voltage match the motor’s requirements.
  2. Check motor wiring and connect, according to instructions on motor, to match supply voltage.
  3. Power cord should be protected by conduit or by cable and be of proper gauge. It should be no longer than necessary.
  4. Power should be drawn directly from a box with circuit breaker protection or with a fused disconnect switch.

PUMP END ASSEMBLY

  1. Inspect all pump parts (O-ring, O-ring groove, impeller hub ID, motor shaft, etc.) and clean if necessary.

  2. Apply sealant to the bracket bore ID wall and around the seal case – follow sealant manufacturer’s instructions. We recommend using Gasgacinch®.
    Note: Silicone sealant can also be used.

  3. Press carbon graphite seal into bracket while taking care not to damage carbon graphite face.

  4. Place slinger (rubber washer) over motor shaft and mount bracket to motor.

  5. Carefully, lubricate the seal seat elastomer OD and impeller hub ID with water. Press the seal seat into the impeller hub making certain that the ceramic is in evenly – the sealing surface should be parallel with the impeller hub.

  6. Carefully lubricate carbon-graphite and ceramic sealing surfaces with clean water. Do not use silicon lubricants or grease.

  7. Assemble Bracket to motor with (4) M-bolts

  8. Thread impeller onto shaft and tighten. If required, remove motor end-cap and use a screwdriver on the back of motor shaft to prevent shaft rotation while tightening. Replace motor end cap.

  9. Seat large O-ring in volute slot and assemble volute to bracket with (7) 1/4-20 x 2 3/4″ hex cap screws, washers and nuts. Tighten in a cross pattern (30 inch-pound force).

  10. Install drain plug with its O-ring in volute drain hole.

  11. Before operating pump, allow a proper cure time for the sealant used in step 2.

SEQUENCE Power 4000 Pump INSTALLATION 2

NO DESCRIPTION SEQUENCE® P/N
1 DRAIN PLUG 1000.110
2 O-RING, DRAIN PLUG E014B70
3 VOLUTE 4000.070
4 LARGE O-RING 1000.061
5 IMPELLER 4000.05__*

6

| SEAL – BRASS| 1000.0415
SEAL – SS316| 1000.0414
SEAL – SS 18-8| 1000.0411
7| BRACKET| 1000.030P
8| SLINGER| 1000.010V
9| HARDWARE KIT
(7) P-BOLTS,  (14) WASHERS,
(7) LOCK NUTS, (4) M-BOLTS| 1000.502

Note: These part numbers are only for standard models within the Sequence® Power 4000. *4000.05__ Reference page one for Impeller numbers.
SEQUENCE Power 4000 Pump INSTALLATION 3

DISASSEMBLY

  1. Shut off power to motor before disconnecting any electrical wiring from the back of the motor.
  2. Disassemble volute from bracket by removing the (7) 1/4″ – 20 threads per inch x 2 3/4″ hex cap screws.
  3. Remove cap covering shaft at back of motor and with a large screwdriver, prevent shaft rotation while unscrewing impeller.
  4. Remove ceramic piece from impeller (If you are replacing the seal).
  5. Detach bracket from motor.
  6. Remove carbon-graphite seal from bracket by pressing out from the back. Do not dig out from the front (If you are replacing the seal).

MAINTENANCE

Lubrication
Motor – Permanently Lubricated ball bearings – no service required.
Rotary Seal – Requires no lubrication after assembly.

WARNING: EYE PROTECTION IS STRONGLY RECOMMENDED
*The pump must be drained before servicing or if stored below freezing temperatures. Periodic replacement of seals may be required due to normal carbon wear.

SYMPTOM PROBLEM RESOLUTION
No Flow Insufficient Prime Prime system with water and purge all air from

suction piping.
Install check valve.
Insufficient Power| Verify power supply and connection from panel to pump.
Verify proper voltage.  Some models are dual voltage (115/230).
Flow Restriction| Ensure valves are open.
Ensure plumbing is clear, including suction strainers, check valves, etc.
Verify check valve orientation and direction of permitted flow.
Clean out leaves or other debris from basket strainer (if applicable).
Air leak| Fix air leaks at fittings, connections, strainer basket etc.  This typically occurs on the intake side.
System Incompatibility| Verify hydraulic compatibility: i.e. pump & pipe are sized for the system.
Low Flow| Air leak| Fix air leaks at fittings, connections, strainer basket etc.  This typically occurs on the intake side.
System Incompatibility| Verify hydraulic compatibility: i.e. pump & pipe are sized for the system.
Insufficient Power| Verify power supply and connection from panel to pump.
Verify proper voltage.  Some models are dual voltage (115/230).
Flow Restriction Flow Restriction| Ensure valves are open.
Ensure plumbing is clear, including suction strainers, check valves, etc.
Clean out leaves or other debris from basket strainer (if applicable).
Insufficient Prime| Prime system with water and purge all air from suction piping.
Cavitation| Verify airtight plumbing on the suction plumbing especially fittings.
Clean out leaves or other debris from basket strainer (if applicable).
Increase pipe size where possible.
Decrease suction pipe length, reduce the number of elbows, etc.
Verify hydraulic compatibility: i.e. pump and pipe are sized for the system.
Sporadic Operation| Insufficient Power| Verify power supply and connection from panel to pump.
Verify proper voltage.  Some models are dual voltage (115/230).
Poor Ventilation| Ensure adequate airflow over motor to prevent overheating.
Excessive Noise| Cavitation| Verify airtight plumbing on the suction plumbing especially fittings.
Clean out leaves or other debris from basket strainer (if applicable).
Increase pipe size where possible.
Decrease suction pipe length, reduce the number of elbows, etc.
Verify hydraulic compatibility: i.e. pump and pipe are sized for the system.
Insufficient Power| Verify power supply and connection from panel to pump.
Verify proper voltage.  Some models are dual voltage (115/230).
Insufficient Power| Ensure valves are open.
Ensure plumbing is clear, including suction strainers, check valves, etc.
Verify check valve orientation and direction of permitted flow.

SEQUENCE Power 4000 Pump Logo2
MDM INCORPORATED
3345 N. Cascade Ave · Colorado Springs, CO · 80907
Phone 719-634-8202 · Fax 866-425-1346
www.mdminc.com · sales@mdminc.com

Gasgacinch® is a registered trademark of Porter Manufacturing.
Teflon® is a registered trademark of the Chemours Corporation.
Sequence® is a registered trademark of MDM Incorporated.
Sequence Power 4000 Installation Manual 2020.indd. Adobe Indesign CC. Updated 10/12/20.

PROUDLY MADE IN THE USA

Reliable. Efficient.
© MDM INCORPORATED WWW.MDMINC.COM P.4

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals