SwissMadison Wall-Hung Carrier System Instruction Manual

June 7, 2024
SwissMadison

SwissMadison Wall-Hung Carrier System - · Once the-

Wall-Hung Carrier System
INSTALLATION INSTRUCTIONS

Residential Concealed In-Wall Toilet Tank
Carrier System for Wall-Hung Toilet
SM-WC424SwissMadison Wall-Hung Carrier System
-Residential

SwissMadison Wall-Hung Carrier System - ICON

PRIOR TO INSTALLATION:

  • Inspect carrier to ensure no damages have occurred while in shipping.

  • Observe all plumbing and building codes in accordance with your state and local requirements.

  • All dimensions are nominal! Be sure to measure your toilet prior to installation.

  • The step-by-step guidelines in the installation instructions are a general reference. Should there be any discrepancies, Swiss Madison cannot be held liable. It is recommended to install all Swiss
    Madison products by hiring a licensed professional.

  • Read installation and maintenance instructions thoroughly before installing. Be sure to use proper tools and always wear proper personal safety accessories for your protection.

  • Be sure to properly bleed all air from the piping system, trapped air can cause damage to the flushing system and toilet bowl.

  • Avoid outside wall installations to avoid possible freezing.

If you have any questions or concerns please contact us:
1-434-623-4766
info@swissmadison.com

SUGGESTED TOOLS & MATERIALS:

SwissMadison Wall-Hung Carrier System -SUGGESTED TOOLS

SwissMadison Wall-Hung Carrier System WALL-HUNG

1.SwissMadison Wall-Hung Carrier System WALL-HUNG01

  • Before fastening sides, you must first attach legs to framing. At this point it is possible to readjust your bowl rim to your desired height.
  • L-shaped mounting brackets are for masonry applications.
  • Fasten your frame into studs/framing using four mounting holes in the carrier frame (two on each side). It is recommended for framing installations to use 2 ¹⁄2” screws and 1 ¹⁄4” fender washers (needing four of each total).
  • Be sure to screw carrier to wood framing flush across the front.

diagram, engineering drawing

3. 4.SwissMadison Wall-Hung Carrier System WALL-HUNG CARRIER
SYSTEM

A
SwissMadison Wall-Hung Carrier System When connecting

  • When connecting to a 3” sewer line it is advised to drill a 3 5⁄8” hole before connecting the discharge pipe to the frame.

SwissMadison Wall-Hung Carrier System -For a vertical

  • For a vertical discharge, leave bracket as shown above.

B

SwissMadison Wall-Hung Carrier System When connecting

  • It is possible to offset the discharge pipe left or right. If offsetting is required, you must move the top bracket holding the discharge pipe to the back holes in the frame. This allows you to miss the carrier frame when connecting the necessary plumbing.

SwissMadison Wall-Hung Carrier System -Use this
mounting

  • Use this mounting position for an offset installation.

SwissMadison Wall-Hung Carrier System installation. -
·

SwissMadison Wall-Hung Carrier System -install dry

  • Install dry wall over carrier system in intended location.

SwissMadison Wall-Hung Carrier System Align template

  • Find cutout template that was included with your carrier.

  • Cut out the small marked holes (1) to align cutout with the threaded bolts.

  • 11. Ensure template is plumb.
    SwissMadison Wall-Hung Carrier System - ·· Ensure template is
plumb

  • Align template up on your wall so the threaded bolts fit through the precut holes.

  • Cut around the marked lines (2) to reveal pipe/actuator locations behind the drywall.

  1. SwissMadison Wall-Hung Carrier System -· Cut drywall
  • Cut drywall to reveal where to install flush plate and attach plumbing.
    NOTE: Swiss Madison is not responsible for any damage done to wall or carrier system.
  1. SwissMadison Wall-Hung Carrier System -· Install mud
  • Install mud guards into proper holes to ensure no debris enters pipes after sheetrock has been cut.
  1. SwissMadison Wall-Hung Carrier System -· Install mud0115 & 16
    SwissMadison Wall-Hung Carrier System -· Install mud0217.
    SwissMadison Wall-Hung Carrier System - Hold the· Hold the shutoff valve stationary while tightening your water connection.

  2. · Install the locknut as shown.
    SwissMadison Wall-Hung Carrier System - ·Install the

  3. SwissMadison Wall-Hung Carrier System Install the
locknu01t

  4. · Once the water connection is made to the water shutoff valve, undo the other side of the hose. Next, turn valve on to flush out any debris before reinstalling to the actuator.
    SwissMadison Wall-Hung Carrier System - Install the
locknut

  5. SwissMadison Wall-Hung Carrier System - · Install with
mounting-22.
    SwissMadison Wall-Hung Carrier System - · Install with
mounting22-
    25&26SwissMadison Wall-
Hung Carrier System WALL-HUNG CARRIER SYSTEM 0127&28SwissMadison Wall-Hung Carrier System - · Install
with mounting--27

Installing the Toilet.

SwissMadison Wall-Hung Carrier System -· Install pipes

· Install pipes. Be sure to seal them thoroughly.

SwissMadison Wall-Hung Carrier System -· With a ruler,

· With a ruler, against finished wall, on top of pipe, mark as shown.

SwissMadison Wall-Hung Carrier System Remove pipes

· Remove pipes from wall and install into back of bowl. Make sure pipes are sealed thoroughly.

SwissMadison Wall-Hung Carrier System - · With a ruler,
against

· With a ruler, against the back of the bowl, on top of pipe, mark as shown.

SwissMadison Wall-Hung Carrier System - ·Measure
distance

· Measure distance between both lines on pipes. Take measured distance, deduct from bald end of pipe and cut.

SwissMadison Wall-Hung Carrier System - Measure
distance01

SwissMadison Wall-Hung Carrier System - ·After cutting

· After cutting, take file and remove all burrs. Try and bevel edge.

SwissMadison Wall-Hung Carrier System - · After cutting
01

SwissMadison Wall-Hung Carrier System - · With grease

· With grease, sponge thoroughly to lubricate all ends.

SwissMadison Wall-Hung Carrier System · Before mounting
bowl

· Before mounting bowl, measure thickness of china and mounting hardware to get approximate depth of threaded rods.

SwissMadison Wall-Hung Carrier System - · Use slotted
end

· Use slotted end of thread bolt to adjust in or out. Do not damage the thread.

SwissMadison Wall-Hung Carrier System - · Install with
mounting

· Install with mounting hardware and ensure toilet bowl is level.

SwissMadison Wall-Hung Carrier System - · Once the-

1-434-MADISON
(623-4766)
19 Stults Road
Dayton, NJ 08810
www.swissmadison.com

ONE YEAR LIMITED WARRANTY

Swiss Madison® products are made with quality materials and excellent craftsmanship to provide our customers with beautiful, durable, long-lasting products. Should there be any defects in materials or craftsmanship under regular use that are discovered within the first year of installation, Swiss Madison® will provide replacement parts at no charge, or at its discretion, replace any product or part of the product that is deemed defective, under normal installation, use, service or maintenance. This warranty applies only to the original purchaser. Proof of purchase will be required in the instance of a claim.

Swiss Madison® recommends all installations of Swiss Madison® products to be conducted by a licensed, professional plumber or contractor. Swiss Madison® will not be held responsible for any damage or product failure due to improper installation, misuse, or failure to utilize a licensed professional for installation. Swiss Madison® is not responsible for any installation or removal costs.

This One Year Limited Warranty Will Be Voided If:

  • The installation recommendations were not followed by the installer
  • The product has been moved from its initial place of installation
  • The product has in any way been modified from its packaged state
  • The product has been subjected to improper maintenance, abuse, misuse, excessive use of chemicals, accidents, or other damages, etc.

Swiss Madison® makes no implication that its products comply with any local building or plumbing codes. It is the consumer’s responsibility and obligation to determine local code compliance prior to and during installation. This warranty extends only to the original purchaser and first consumer.

Swiss Madison® is not responsible for any special, incidental or consequential damages associated with the installation, replacement, return or use of the original purchaser’s product. This includes, but is not limited to: freight costs, labor, travel time, lost profit, home damages and other contingent liabilities and costs (including, without limitation, costs associated with ‘professionals’ or ‘experts’, investigations, audits, analyses, attorneys and any other professional/hired services).

The Swiss Madison® warranty is a comprehensive and explicit limit of liability. All items not disclosed within the warranty are not addressable within the responsibility of Swiss Madison®. Certain states have variances regarding implied warranties; in those situations, we remain fully compliant.

If you have any questions or concerns, please contact us directly at 1-434-MADISON (623-4766)

WARNING: Contents of your order may contain sharp and possibly other harmful pieces and may cause hazard to children and adults. Swiss Madison® is not responsible in any way for personal damages.