1 Product overview
1.1 Product profile
The POP 3D scanner adopts proprietary 3D camera module and embedded chip to deliver accurate and fast 3D scan. This scanner is designed compact and portable, with multi-type scanning capability. It meets the requirement for product development, prototyping, 3D printing users, and artistic creation.
1.2 Packing list
No.
| Item| Qty.
---|---|---
1| Scanner|
1
2
| USB cable| 1
3| Type-C adapter(optional)|
1
4
| Scanner Holder| 1
5| Black gloves|
1
6
| Markers| 1
7| Black plastic sheet|
1
8
| Sample sculpture| 1
9| Specification, Warranty Card, Certification|
1
10
| Turntable(optional)|
1
1.3 Specifications
Product model | 3D scanner |
---|---|
Technology | Dual camera infrared structured light |
Single capture accuracy | Up to 0.3mm |
Single capture range | 210mm x 130mm |
Working distance | 275mm ± 100mm |
Minimum scan volume | 50×50×50 (mm) |
Scan speed | 8 fps |
Light source | 1 class infrared Laser (eye-safe) |
Alignment | Feature alignment, marker point alignment |
Output format | STL, PLY, OBJ |
Texture scan | Yes |
Special object scanning | For the transparent and highly reflective objects, |
please spray powder before scanning
Outdoor scanning| Cover is needed to avoid interference of strong light
Scanner weight| ≤100g
Dimensions (mm)| 154.6×38.2×25.6
Printable data output| Able to export 3D model directly to 3D printing
Required computer configurations| Windows 8\10, 64-bit
Wifi| 2.4G
Note| *The aforesaid accuracy is acquired in standard lab environment, which
might vary subject to actual operating environment.
1.4 Computer configuration requirements
Recommended configuration: Graphics card memory >2GB; i7-6700 processor; 16GB RAM, USB3.0
1.5 Scannable objects
A single-frame scanning range of the 3D scanner is 210mm x 130mm, and the
scannable object size is from 50×50×50 (mm) to 2m.
Hair or flakes cannot be scanned directly. When scanning some objects (such as
human face), you need to keep the objects still.
If the scanned object doesn’t have enough shape features, you need to stick
marker points on its surface for alignment.
Transparent and highly reflective objects cannot be scanned directly, unless
powder is sprayed.
2 Hardware
2.1 Hardware profile
2.2 Hardware connection
3 Software
3.1 Obtaining software
Find the software installation package (Handyscan.exe) in the USB flash disk, or download it on our official website.
3.2 Software installation
Double-click the Handyscan.exe.
Read the agreement and choose “I accept the agreement”, and then click “Next”
to finish installation. After the installation is finished, two software
shortcuts will be generated as follows:
scanning software ,and the post-processing .
3.3 Software update
The scanning software, can be updated online. The system will inform you when a new version is detected. Follow the instructions to update to the latest version.
3.4 Software interface
Double click , the following UI is shown.
(1) Top navigation bar includes: Status (Preview-Scan-Finish), model type POP
and About buttons;
(2) Scanning distance prompt: (Scanning distance: Too near, Excellent, Good,
Too Far, when the scanning distance is in the Excellent zone, the result is
appropriate, when it is too close or too far, red color will be displayed.
Adjust to the optimal scanning distance according to the color prompt);
(3) RGB image display and infrared image display;
(4) Real-time scan data display;
(5) Function buttons: New, Open, Start/Pause, Stop/Complete, Undo, Delete,
Mesh, Texture, Export;
(6) Left mouse button: Rotate the model; Wheel: Zoom in/out
4 Start scanning
4.1 Create a new project
Name the project or import a model.
Select alignment method: feature alignment (suitable for object with rich
shape features on the surface), marker alignment and portrait mode.
Select scan mode: no colour scan (without texture), texture scan (with color
texture).
4.2 Open a project
★You can import a 3D file(.ply) that has been scanned before and capture a second scan.
5.3 Scan preview
Adjust the camera parameters in the left preview box. Two tuning modes are
supported: manual and auto.
In manual mode: the brightness value and the gain value can be set manually.
It is recommended to tune the brightness value in the case of accuracy is
prior and the gain value in the case of speed is prior. For example, to reach
high scan accuracy, please keep gain to 1 while tuning brightness to an
appropriate value. To reach high scan speed, please try gain 2 or 3 while
keeping brightness value as small as possible.
In auto mode, please place the object to be scanned in front of the scanner.
Choosing “auto” and gain value, the brightness value will be selected
automatically.
4.3 Start scanning
Click the “Start” button to start scanning. If you want to make a pause,
click the “Pause” button . Click the “Stop” button to finish the scan, or
restart a new scan.
At the beginning of scanning, target the object for 2 seconds, and then slowly
move the scanner around the object to start scanning. The captured frames
(shown in blue) and the current frame (shown in green) will display. In order
to improve scanning efficiency, it’s better to move the scanner slowly and
stably during scanning while keeping a relatively fixed distance.
Common problems:
(1) Miss track
When this prompt appears, you need to return to the previous scanned area and
re-align the model to continue the scan.
(2) Too few points
When this prompt appears, check whether the distance between the scanner and
the object is too close or too far, adjust the distance to the appropriate
range before scanning.
(3) Detect plane
This prompt appears when alignment error occurs in the case of scanning planes or objects with few features. To solve this problem, you can attach markers to the object surface, and select marker alignment mode before scanning.
4.4 Finish scanning
Click the “Stop” button to finish the scan, and then the point cloud data will be fused by default.
4.5 Meshing
Click the “Mesh” button to start converting the scanned point cloud into mesh.
4.6 Texturing
The texture function only applies to the color scan mode. Click the “Texture” button , the texture mapping will then be processed..
4.7 Export
Click the “Export” button , select the file type and a location for the files to be saved, and name the file, to export the 3D model data. The file formats of “obj, stl, ply” are supported.
5 Post-processing
Double click to open the post-processing software : 3DModel Process
(1) Click the drop-down button next to “Model” button and select local model ;
(2) Model processing: single model and multi-model processing are supported;
(3) The “Process” button at the bottom of the menu bar is for single-model
processing, and the “Merge” button is for multi-model processing, you can
select between the two;
Process
Mesh:
convert the point clouds into mesh.
Clip: clip the model plane.
Fill hole: fill holes on the model surface.
Smooth: smooth the flat/curved surface.
Undo: cancel the current operation and revert to the previous state.
Export: export models in PLY/STL/OBJ format.
Merge
(Multi models)
Align: align two imported models.
Merge: merge aligned models into one model.
Texture: map texture onto the model.
Undo: cancel the current operation and revert to the previous state.
Export: export models in PLY/STL/OBJ format.
(4) File formats: ply/obj/stl
At the bottom of the software interface, you can see specific operation
instructions.
6 FAQ
Q The preview image is stuck.
A (1) plug off and in to reconnect the USB data cable; (2) if the
software does not respond, restart the software.
Q The size of the object is too small, and the scan usually fails.
A The minimum scannable size is: 50×50×50 (mm). To scan objects smaller
than this size, a turntable is required to help the scanning.
7 Precautions
(1) Please use the device indoors at the temperature of -10°~35°. The
scanning effect would be better under dark light. If you need to use it
outdoors, please block the sunlight and ambient light properly.
(2) Do not dismantle or modify the device.
(3) Please do not use the device in where there is dust or cigarette
smoke.
(4) Do not wet it by exposure to liquid such as fresh water, sea water,
milk, soda or soap water.
(5) Do not use or store the device in extremely high temperature
environment, such as putting it near fire or heater.
(6) Do not hit the device fiercely. Do not hammer it, pile up heavy
objects on it, step on it or drop it down.
(7) In case of any device failure, please stop using the device and
contact your local distributor or authorized maintenance agent.
WARNING
The product cannot be returned if the “Warranty Void If Removed” label is damaged or removed.
Federal Communications Commission (FCC) Statement. This device complies with
part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide Reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician for help.
Warning: Changes or modifications made to this device not expressly approved
by Revopoint 3D Technologies Inc. may void the FCC authorization to
operate this device.
Note: The manufacturer is not responsible for any radio or TV interference
caused by unauthorized modifications to this equipment. Such modifications
could void the user’s authority to operate the equipment.
RF exposure statement:
The transmitter must not be colocated or operated in conjunction with any
other antenna or transmitter. This equipment complies with the FCC RF
radiation exposure limits set forth for an uncontrolled environment. The
device can be used in portable exposure condition without restriction.
Read User Manual Online (PDF format)