IMPORTANT SAFEGUARD

When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following:

DANGER:
To reduce the risk of electrocution

  • Do not handle charger with wet hands.
  • Do not place charger in or drop charger into water or other liquid.
  • Check the charger cord for damage before the first use and during the life of the product.

WARNING:

  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Oral irrigators shall be used only with cold or warm water, or specific solutions as defined in the manufacturer’s instructions.
  • Children shall not play with the appliance.
  • It must only be supplied at safety extra low voltage corresponding to the marking on the appliance.
  • The product contains batteries that are non-replaceable.
  • Do not plug this device into a voltage system that is different from the voltage system specified on the device or charger.
  • If product is opened/disassembled for ANY reason, warranty is VOID.
  • Do not use this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Please contact your local distributor.
  • Do not direct water under the tongue, into the ear, nose or other delicate areas. This product is capable of producing pressures that may cause serious damage in these areas.
  • Do not direct water into the nose or ear. The potentially deadly amoeba, Naegleria fowleri, may be present in some tap water or unchlorinated well water and may be fatal if directed into these areas.
  • Use this product only as indicated in these instructions or as recommended by your dental professional.
  • Magnetic field: Pacemakers and similar implanted medical devices may be affected by magnet.
  • Do not drop or insert any foreign object into any opening on the product.
  • Keep charging unit and cord away from heated surfaces.
  • Do not use this product outdoors or operate where aerosol (spray) products are being used or where oxygen is being administered.
  • Do not use iodine, saline (salt solution), or water insoluble concentrated essential oils in this product. Use of these can reduce product performance and will shorten the life of the product. Use of these products may void warranty.
  • Remove any oral jewelry prior to use of this product.
  • Do not use if you have an open wound on your tongue or in your mouth.
  • If your physician advised you to receive antibiotic premedication before dental procedures, you should consult your dentist before using this instrument or any other oral hygiene aid.
  • Close supervision is necessary when this product is used by, on, or near children or invalids.

PRODUCT DISCRIPTION

image 1

PRODUCT ACCESSORIES

image 2

OPERATING PROCEDURES

Preparation Work

image 3

Open the water tank lid and pour water into the water tank.
Note: please ensure that when pouring water into the tank, the device is switch off.
Make PPM touch water in the tank, and then temperature and water quality will be showed.

image 4

Insert and remove tips

image 5

Modes selecting
Irrigation modes can be selected by pressing mode button lightly

image 6

How to close
The machine switches off automatically after 2 minutes or press On/Off button to turn it off while irrigating.
When turn off the machine, the display will be off after 3 seconds.

image 7

USAGE INSTRUCTIONS

  • If when battery symbol is flashing, means it is in low battery, pls charge it on time.
  • When charging in first 5 seconds, there is battery symbol lighting and digital proportional display. After 5 seconds, it will be in eye-protection screen, and then show 100% when fully charged.
  • OLED screen shows: working mode/water temperature/water quality(PPM) battery capacity/working time.
  • This product cannot be used during charging
  • We can select mode first before switch on the machine.
  • This product has memory function the mode remains the same as last usage when switched on again.

Recommended Techniques

Direct the jet stream at a 90 angle to your gumline.

image 9

image 10

Disassembly Example

After usage

Please switch off the power, as well as empty the water tank.

image 11

Disassemble water tank or store nozzle tips
Using both hands as indicated in Diagram 2,3 – use your left hand to hold the product body, and your right hand to hold the water tank. At the same time rotate downwards in an anti-clockwise direction, in order to remove the water tank.

image 12

Storage for nozzle tips
The water tank can store nozzle tips, when using, disassemble water tank and take out the nozzle tip, install it in the knob. After finish using, take nozzle tip off and put it in the tank. pls check the diagram 4.

image 13

Battery Maintenance and Handling

Battery Maintenance

  • For first use battery must be charged, for 5 hours.
  • If device will be stored for long time, please fully charged it in advance.

Battery handling

The device includes a lithium battery which cannot be changed. To preserve the environment, do not throw away the appliance with the normal household waste at the end of its life, but handle it in at an official collection point for recycling.

Common problems and solutions

Leakage of water between jet tip and screw part| The seal ring on the fixed socket for the jet tip is damaged, and the jet tip can not be installed properly| Contact the retailer for repair, and install the jet tip properly
---|---|---
Water tank leaks water| Seal ring is loose| Re-install correctly
Inadequate pressure| Low voltage usage| Use after recharging
Device can not be switched on| Low voltage usage| Use after recharging
Water is not coming out| Nozzle clogging

Water valve plate is too dry

| Suck the jet tip by mouth inject water to jet tip or fill water into water tank and shake
No temperature and PPM showing| Water no touch sensor| Lean the irrigator to make water touch the sensor  completely