GE APPLIANCESS Universal 36″ Telescopic Downdraft System UVD6361SP User Guide

June 7, 2024
GE APPLIANCESS

UVD6361SP
Universal 36″ Telescopic Downdraft System

GE APPLIANCESS Universal 36″ Telescopic Downdraft
-DIMENSIONS

DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)

NOTE: Telescopic downdraft vents are not recommended to be installed with cooktops that are flush-mounted.Approved for use with the following Monogram, GE Profile  ™ Series and GE  ®Series cooktops–36″  electric models, 36″ gas- sealed burner models and 36″ induction models.
NOT APPROVED FOR USE WITH STANDARD
BURNER GAS COOKTOPS.

NOTE: The countertop must be at least 26″ deep with a flat surface area of 23-1/2″ or more, front to back.  In addition, other clearances to the front edge of the countertop must be considered.

NOTE: Dimensions shown are for reference only. Before cutting out the countertop, refer to instructions packed with downdraft and cooktop.

NOTE: Installation on cabinets/countertops against the wall will not be possible in most applications. Against the wall, installations are limited to dimension requirements. Refer to installation instructions packed with the product for further details.

For answers to your Monogram, GE Café ™, GE Profile ™, or GE
Appliances product questions, visit our website at geappliances.com or
call GE Answer Center  ® Service, 800.626.2000.

VENTING DUCT INFORMATION

DUCT PIECES| EQUIVALENT LENGTH| DUCT PIECES| EQUIVALENT LENGTH
---|---|---|---
6″ ROUND STRAIGHT| 1 ft. (per foot length)| 3-1/4″ X 10″
TO 6″ ROUND
TRANSITION| 2 ft.
3-1/4’× 10″
STRAIGHT| 1 ft. (per foot length)| 6″ROUND
TO 3-1/4″ × 10″
TRANSITION
90° ELBOW| 4 ft.
6″
90º ELBOW|  12 ft| 3-1/4″×10″
Top 6″ ROUND TRANSITION
90° ELBOW| 4 ft.
6″
45º ELBOW|  14ft| 6″ ROUND WALL CAP  WITH DAMPER| 24 ft.
3-1/4” ×10″
90º ELBOW| 7ft| 3-1/4″ X 10″ WALL

WITH DAMPER

| 24 ft.
3-1/4” ×10″
45º ELBOW|  12ft
3-1/4 ×10″
45º ELBOW| 33 ft| 6″ ROUND ROOF CAP|

33 ft.

6” ROUND
TO 3-1/4×10″
TRANSITION| 2 ft| R* Equivalent length of duct pieces is based on an actual test conducted by  GE Evaluation Engineering and reflects requirements for good venting performance.

PLAN THE DUCTWORK

  1. This downdraft blower system is designed for use with 3-1/4″ x 10″ ductwork (can be transitioned to 6″ round). Two different discharge directions are available with side to- side adjustment for the accurate alignment of ductwork.
  2. For best performance: choose the ducting option which allows the shortest length of ductwork and a minimum number of elbows and transitions. Check the location of floor joists, wall joists, wall studs, electrical wiring or plumbing for possible interference.

GE APPLIANCESS Universal 36″ Telescopic Downdraft -
DUCTWORK

STEPS TO DETERMINE FLEXIBLE DUCTING’S EQUIVALENT LENGTH

  1. Measure the actual amount of offset (Maximum 3″ recommended). The effect upon airflow is dependent upon the amount of offset.
  2.  Calculate the equivalent ducting allowances using: (in. offset) x (14 ft. per inch) =ft. equivalent length.
  3. Total equivalent length of ducting should not exceed the maximum recommendation of 100 feet for optional venting performance.

FEATURES AND BENEFITS

GE APPLIANCESS Universal 36″ Telescopic Downdraft - FEATURES AND
BENEFITS

500 CFM – Make sure everyone is focused only on your food with a 500-CFM venting system that removes smoke, grease, odors and moisture from the air.
Adjustable fan speed – Adjust your vents to match your cooking techniques with infinite fan control that removes grease, odors and moisture.
Grease filters – Keep your clean-up to a minimum with a removable grease filter that helps eliminate hand scrubbing.
Aluminum mesh filters – Easy to remove, dishwasher safe.
Hides into countertop – Raises over cooktop surface and retracts when not in use.
Model UVD6361SPSS – Stainless Steel

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GE APPLIANCESS User Manuals

Related Manuals