ZOOZ Multirelay ZEN16 User Manual
- June 7, 2024
- ZOOZ
Table of Contents
ZOOZ Multirelay ZEN16
FEATURES
- Powerful dry contact relays to control loads up to 15 A and 20 A
- Perfect for outdoor lighting, pool pumps, garage door, or gas fireplace
- Control up to 3 connected loads independently or together
- Z-Wave or optional wall switch control (toggle or momentary type)
- Built-in timers for each relay to simplify automation
- Remembers and restores on/off status after power failure
- Built-in Z-Wave Plus signal repeater to extend network range
- Powered by 12-24 V DC/AC or USB C port for easy set-up
- Wall mounting and minimal design for clean installation
- S2 security protocol and the latest 500 Z-Wave chip
SPECIFICATIONS
- Model Number: ZEN16
- Z-Wave Signal Frequency: 908.42 MHz
- Power: 12-24 V DC/AC or USB C (DON’T use laptop / tablet chargers)
- Maximum Load: Relay 1: 15A (1/3HP), R2: 15A (1/3HP), R3: 20A (¾HP)
- Range: Up to 100 feet line of sight
- Operating Temperature: 32-104
- Installation and Use: Indoor only.
CAUTION:
This is an electrical device – please use caution when installing and
operating the Multi Relay. Remote control of appliances may result in
unintentional or automated activation of power.
BEFORE YOU INSTALL
This device is intended for installation in accordance with the National Electric Code and local regulations. It is recommended that a licensed electrician perform this installation. USE A SINGLE POWER SOURCE AT ALL TIMES.
WIRING: READ IT!
- CHECK THE LOAD: make sure that the connected appliance does not exceed 15 A for Relay 1 and Relay 2 or 20 A for Relay 3.
- POWER OFF: turn the circuit power off in the breaker panel before you start. If handling wiring from a box with multiple circuits, turn power off at all of the circuits.
- REMOVE THE WALL SWITCH: if the load is currently controlled by a wall switch, carefully remove it from the box and disconnect the wires from the switch.
- CONNECT THE MULTI RELAY: follow the instructions in the appropriate diagram for your set-up. If you can’t find your scenario in the diagrams below, please request custom instructions from our support team, we’re happy to help: ask@getzooz.com
WIRING TIPS
TAKE PICTURES
Before you disconnect any wires, document your set-up and send us images of your existing installation so we can help if needed.
GATHER YOUR TOOLS
Always use the correct screwdriver size for the terminal screws on your Multi Relay and wall switches (if connecting them). Use appropriate electrical tools when cutting, prepping, and stripping electrical wires. If you don’t have the necessary tools to perform the installation or are not sure which tools to use or how, please hire an electrician to complete the installation for you.
SAFETY FIRST
Follow the National Electrical Code and your local safety regulations when performing the installation, including (but not limited to), choosing the correct gauge of jumper wires. The recommended gauge for 15 Amp circuits is 14 AWG and 12 AWG for 20 Amp circuits.
HOW TO SECURE WIRES IN TERMINALS:
first, unscrew the appropriate terminal’s screw just far enough so there is a
clear opening in the terminal for the wire to go in. Make sure the wire is
stripped at the right length and perfectly straight before you insert it into
the terminal. Once you put the wire in the terminal, carefully screw the
terminal screw back in to hold down the wire. Check the connection by gently
pulling on the connected wire to make sure it’s fixed securely.
POWER THE MULTI RELAY:
connect the USB C power source to the Multi Relay or use the”+””-” terminals
on the device to bring low voltage power to it. Never use both at the same
time. In both cases you’ll need a standard 1 A power adapter to plug into a
standard 120 VAC receptacle. Do NOT use with laptop or tablet chargers, they
require a large battery on load to activate.
MULTI RELAY 2EN16 WIRING DIAGRAMS
WIRING DIAGRAM FOR GARAGE DOOR OPENERS
Connect to simple wall momentary opener switches only! “Fancy” switches with electronic displays will not work with the MultiRelay. Use with traditional motorized garage door openers only. The Multi Relay will NOT work with smart openers like the myQ system.
ZEN16 WIRING DIAGRAM FOR GAS FIREPLACE MILLIVOLT VALVE
ZEN16 WIRING DIAGRAM FOR POOL LIGHT AND POOL PUMP
Z-WAVE CONTROL
-
ADD DEVICE to your hub
Initiate inclusion (pairing) in the app (or web interface). Not sure how? Use the camera on your phone to scan the QR code below for hub specific instructions. -
Finalize inclusion at the device. Click the 2-Wave button 3 times quickly to add the Multi Relay to your network.
The LED indicator will blink to signal communication and remain on for 2 seconds to confirm inclusion.
Choose your hub and scan the QR code with your phone’s camera. Then click on the link to access step-by-step pairing instructions. Get more tutorials and helpful tips at www.support.getzooz.com
NEED SOME HELP? ask@getzooz.com
TROUBLESHOOTING
The Multi Relay won’t add to your system? Try this:
- Initiate EXCLUSION and click the Z-Wave button 3 times quickly.
- Click the Z-Wave button 4-5 times quickly when adding it.
- Bring your Multi Relay closer to the gateway controller (hub), it may be out of range.
- Get troubleshooting tips for your hub at www.support.getzooz.com
EXCLUSION (REMOVING/ UNPAIRING DEVICE)
- Bring your Multi Relay close to the Z-Wave gateway (hub) and power it
- Put the Z-Wave hub into exclusion mode (not sure how to do that?ask@getzooz.com)
- Click the Z-Wave button 3 times quickly
- Your hub will confirm exclusion and the Multi Relay will disappear from your controller’s device list.
FACTORY RESET
If your primary controller is missing or inoperable, you may need to reset the
device to factory settings. To complete the reset process manually, click the
2-Wave button 4 times quickly, the LED indicator will light up, then quickly
click the 2-Wave button 4 times again. The LED indicator will flash 3 times to
confirm successful reset and will then turn off.
NOTE: All previously recorded activity and custom settings will be erased
from the device’s memory.
WARNING:
- This product should be installed indoors upon completion of any building renovations.
- Prior to installation, the device should be stored in a dry, dust-and-mold-proof place.
- Do not install the device in a place with direct sun exposure, high temperature, or humidity.
- Keep away from chemicals, water, and dust.
- Ensure the device is never close to any heat source or open flame to prevent fire.
- Ensure the device is connected to an electric power source that does not exceed the maximum load power.
- No part of the device may be replaced or repaired by the user.
This product can be included and operated in any Z-Wave network with other
Z-Wave certified devices from other manufacturers and/or other applications.
All non-battery operated nodes within the network will act as repeaters
regardless of vendor to increase reliability of the network.
This product features the latest Security 2 (S2) framework to remove smart
home network hacking risks. This device is equipped with a unique
authentication code for trusted wireless communication. This is an ETL
certified device. ETL, just like UL, is a Nationally Recognized Testing
Laboratory. The ETL mark is proof of product compliance with North American
safety standards.
COMMAND CLASSES
This device requires the following command classes to be supported and
recognized by your Z-Wave controller:
COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
COMMAND_CLASS_ASSOCIATION_GRP _INFO
COMMANDCLASS TRANSPORT _SERVICE
COM MAN DCLASS VERSION
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COM MAN D_CLASS_DEVICE_RESET _LOCALLY
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_MULTI_CHANNEL
COM MAN D_CLASS_SECU Rl1Y _2
COM MAN D_CLASS_SUPERVISION,
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
ADVANCED SETTINGS
Please refer to your controller’s user guide for advanced programming instructions as they are a little different for every software. Not sure where to start? Go to www.support.getzooz.com for detailed instructions on how to change the settings on SmartThings, Vera, and more. Or just email us: ask@getzooz.com
ASSOCIATION
This device supports Group 1 with up to 1 devices for lifeline communication
and Groups 2 (for Relay 1), 3 (for R2), 4 (for R3) with up to 5 devices each
to send BASIC_SET reports when operated manually.
CUSTOMIZE YOUR MULTI RELAY
On Off Status After Power Failure
Parameter 1: Set the on off status for the relays after power failure.
Values: 0 -ALL relays forced to OFF (regardless of state prior to power
outage); 1-ALL relays remember and restore on/off status after power failure
(default); 2 -ALL relays forced to ON (regardless of state prior to power
outage); 3 -Relay 1 and Relay 2 remember and restore on/off status after power
failure, Relay 3 forced to OFF; 4
-Relay 1 and Relay 2 remember and restore on/off status after power failure, Relay 3 forced to ON. Size: 1 byte dee. Switch Type for Relay 1 (Swl)
Parameter 2: Choose the wall switch type you want to connect to the Swl
terminal. Values: 0 -momentary for lights only; 1-toggle switch (light on when
the switch is toggled up, light off when the switch is toggled down); 2
-toggle switch (state changes whenever the switch is toggled); 3 -garage door
(momentary mode for Z-Wave control). Default: 2. Press and hold the Z-Wave
button for 5 seconds to change mode manually. Size: 1 byte dee. Switch Type
for Relay 2 (Sw2)
Parameter 3: Choose the wall switch type you want to connect to the Sw2
terminal. Values: O -momentary for lights only; 1-toggle switch (light on when
the switch is toggled up, light off when the switch is toggled down); 2
-toggle switch (state changes whenever the switch is toggled); 3 -garage door
(momentary mode for Z-Wave control). Default: 2. Click-click’n’hold the Z Wave
button for 5 seconds to change mode manually. Size: 1 byte dee.
Switch Type for Relay 3 (Sw3) Parameter 4: Choose the wall switch type you
want to connect to the Sw3 terminal.
Values: 0 -momentary for lights only; 1-toggle switch (light on when the
switch is toggled up, light off when the switch is toggled down); 2 -toggle
switch (state changes whenever the switch is toggled); 3 -garage door
(momentary mode for Z-Wave control). Default: 2. Click-click-click’n’hold the
Z-Wave button for 5 seconds to change mode manually. 1 byte dee.
LED Indicator Control
Parameter 5: Choose if you want the LED indicator to turn on when any of the
relays are on or if all of them are off, or if you want it to remain on or off
at all times. O -LED indicator is on when ALL of the relays are off, LED
indicator is off when any of the relays is on
(default); 1-LED indicator is on when any of the relays is on, LED indicator
is off when ALL of the relays are off; 2 – LED indicator is always OFF; 3 -LED
indicator is always ON.
Click the Z-Wave button 5 times quickly to change mode manually. Size: 1 byte
dee. Auto Turn-Off Timer for Relay 1
Parameter 6: Use this parameter to set the time after which you want the
device connected to Relay 1 to automatically turn off once it has been turned
on. The number entered as value corresponds to the number of minutes, seconds,
or hours (set the unit in Par.15). Values: 0 -timer disabled (default);
1-65535.
Size: 4 byte dee.
Auto Turn-On Timer for Relay 1
Parameter 7: Use this parameter to set the time after which you want the
device connected to Relay 1 to automatically turn on once it has been turned
off. The number entered as value corresponds to the number of minutes,
seconds, or hours (set the unit in Par.16). Values: 0 -timer disabled
(default); 1-65535. Size: 4 byte dee.
Auto Turn-Off Timer for Relay 2
Parameter 8: Use this parameter to set the time after which you want the
device connected to Relay 2 to automatically turn off once it has been turned
on. The number entered as value corresponds to the number of minutes, seconds,
or hours (set the unit in Par.17). Values: 0 -timer disabled (default);
1-65535. Size: 4 byte dee.
Auto Turn-On Timer for Relay 2
Parameter 9: Use this parameter to set the time after which you want the
device connected to Relay 2 to automatically turn on once it has been turned
off. The number entered as value corresponds to the number of minutes,
seconds, or hours (set the unit in Par.18). Values: 0 -timer disabled
(default); 1-65535. Size: 4 byte dee.
Auto Turn-Off Timer for Relay 3
Parameter 10: Use this parameter to set the time after which you want the
device connected to Relay 3 to automatically turn off once it has been turned
on. The number entered as value corresponds to the number of minutes, seconds,
or hours (set the unit in Par. 19). Values: 0 -timer disabled (default);
1-65535. Size: 4 byte dee.
Auto Turn-On Timer for Relay 3
Parameter 11: Use this parameter to set the time after which you want the
device connected to Relay 3 to automatically turn on once it has been turned
off. The number entered as value corresponds to the number of minutes,
seconds, or hours (set the unit in Par. 20). Values: 0 -timer disabled
(default); 1-65535. Size: 4 byte dee.
Enable/Disable Manual Control for Swl
Parameter 12: Enable or disable physical on/off control of Relay 1 from the
wall switch connected to Swl terminal. If disabled, you’ll only be able to
control the connected device via Z-Wave.
Values: 0 -local control disabled. 1-local control enabled (default). 2 -local
control disabled with enabled on/off reports (connected switch won’t control
the relay but it will send on/off reports to the hub when triggered). lbyte
dec.
Enable/Disable Manual Control for Sw2
Parameter 13: Enable or disable physical on/off control of Relay 2 from the
wall switch connected to Sw2 terminal. If disabled, you’ll only be able to
control the connected device via Z-Wave.
Values: 0 -local control disabled. 1-local control enabled (default). 2 -local
control disabled with enabled on/off reports. Size: 1 byte dee.
Enable/Disable Manual Control for Sw3
Parameter 14: Enable or disable physical on/off control of Relay 3 from the
wall switch connected to Sw3 terminal. If disabled, you’ll only be able to
control the connected device via Z-Wave.
Values: 0 -local control disabled. 1-local control enabled (default). 2 -local
control disabled with enabled on/off reports. Size: 1 byte dee.
Auto Turn-Off Timer Unit for Relay 1
Parameter 15: Choose between seconds, minutes, and hours as the unit for the
auto turn-off timer for Relay 1. O -minutes (default); 1-seconds; 2 -hours.
Size: 1 byte dee.
Auto Turn-On Timer Unit for Relay 1
Parameter 16: Choose between seconds, minutes, and hours as the unit for the
auto turn-on timer for Relay 1. Values: 0 -minutes (default); 1-seconds; 2
-hours. Size: 1 byte dee.
Auto Turn-Off Timer Unit for Relay 2
Parameter 17: Choose between seconds, minutes, and hours as the unit for the
auto turn-off timer for Relay 2. Values: 0 -minutes (default); 1-seconds; 2
-hours. Size: 1 byte dee.
Auto Turn-On Timer Unit for Relay 2
Parameter 18: Choose between seconds, minutes, and hours as the unit for the
auto turn-on timer for Relay 2. Values: 0 -minutes (default); 1-seconds; 2
-hours. Size: 1 byte dee.
Auto Turn-Off Timer Unit for Relay 3
Parameter 19: Choose between seconds, minutes, and hours as the unit for the
auto turn-off timer for Relay 3. Values: 0 -minutes (default); 1-seconds; 2
-hours. Size: 1 byte dee.
Auto Turn-On Timer Unit for Relay 3
Parameter 20: Choose between seconds, minutes, and hours as the unit for the
auto turn-on timer for Relay 3. Values: 0 -minutes (default); 1-seconds; 2
-hours. Size: 1 byte dee.
DC Motor Mode
Parameter 24: Sync Rl and R2 together to prevent them from being activated at
the same time. Values: 0 -DC motor mode disabled (relays will activate
whenever they’re triggered); 1-DC motor mode enabled (relay will check the
status of the other relay after being triggered and will shut the other relay
off before activating so that only one of the relays is on at the same time).
Default: 0. Size: 1 byte dee.
QUESTIONS?
ask@getzooz.com /
www.support.getzooz.com
WARRANTY
This product is covered under a 12-month limited warranty. To read the full
warranty policy or file a warranty claim, please go to
www.getzooz.com/warranty
IN NO EVENT SHALL ZOOZ OR ITS SUBSIDIARIES AND AFFILIATES BE LIABLE FOR ANY
INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL, OR CONSEQUENTIAL DAMAGES, OR DAMAGES
FOR LOSS OF PROFITS, REVENUE, OR USE INCURRED BY CUSTOMER OR ANY THIRD PARTY,
WHE-THER IN AN ACTION IN CONTRACT, OR OTHERWISE EVEN IF ADVISED OF THE
POSSIBILl1Y OF SUCH DA-MAGES. ZOOZ’S LIABILl1Y AND CUSTOMER’S EXCLUSIVE REMEDY
FOR ANY CAUSE OF ACTION ARISING IN CON-NECTION WITH THIS AGREEMENT OR THE SALE
OR USE OF THE PRODUCTS, WHETHER BASED ON NEGLIGENCE, STRICT LIABILl1Y, BREACH
OF WARRANTY, BREACH OF AGREEMENT, OR EQUITABLE PRINCIPLES, IS EXPRESSLY
LIMITED TO, AT ZOOZ’S OPTION, REPLACEMENT OF, OR REPAYMENT OF THE PURCHASE
PRICE FOR THAT POR-TION OF PRODUCTS WITH RESPECT TO WHICH DA-MAGES ARE
CLAIMED. ALL CLAIMS OF ANY KIND ARISING IN CONNECTION WITH THIS AGREEMENT OR
THE SALE OR USE OF PRODUCTS SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING
WITHIN THIR1Y (30) DAYS FROM ZOOZ’S DELIVERY, OR THE DATE FIXED FOR DELI-VERY
IN THE EVENT OF NONDELIVERY.
FCC NOTE THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE
CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS
COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. STORE INDOORS WHEN
NOT IN USE. SUITABLE FOR DRY LOCATIONS ONLY. DO NOT IMMERSE IN WATER. NOT FOR
USE WHERE DIRECTLY EXPOSED TO WATER.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following conditions:
- This device may not cause harmful interference,
- This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used according to instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in any given installation. If this equipment causes harmful interference to radio or television reception, the user may try to correct the interference by taking one or more of the following measures:
- Reorient or relocate receiving antenna
- Increase the separation between equipment and receiver
- Connect equipment into a separate outlet or circuit from receiver
- Consult the dealer or an experienced radio/TV technician for additional assistance.
All brand names displayed are trademarks of their respective holders. © Zooz 2020.
Read User Manual Online (PDF format)