HYGIPLAS F338 Multi-purpose Stem  Model F338

Safety Tips

  • Clean the probe immediately after each measurement to avoid cross-contamination
  • Do not expose the appliance to temperatures over 50ºC/122ºF or use in ovens.

Installation

  1. Open the battery compartment on the bottom of the appliance.
  2. Insert the battery (Negative (-) terminal first).
  3. Pull out as much of the probe cable as required.
  4. Close the battery cover.

Operation

Temperature Measurement

  1. Press the On/Off button to power up the thermometer.
  2. Insert the probe approximately 25mm (1”) into the foodstuff.
  3. The temperature of the foodstuff is displayed when the value remains constant.

Units of Measurement
Press and hold the ºC/ºF button for three seconds to alternate between Centigrade and Fahrenheit.

Data Hold

  1. Press the HOLD button to keep the current reading displayed.
  2. Press the HOLD button again to resume normal operation.

Maximum/Minimum Readings
The thermometer can store and display the maximum and minimum temperature readings taken since the last reset:

  1. Press the MAX/MIN button. The MAX icon flashes and the maximum temperature taken displays on the screen.
  2. Press the MAX/MIN button again. The MIN icon flashes and the minimum temperature taken displays on the screen.
  3. Press the button again to resume normal operation.

Note: To reset the memory turn the thermometer Off and then On again.
Always reset the memory before taking new readings to ensure accuracy.

High/Low-Temperature Alarm
The thermometer can sound an alarm when a set temperature range is exceeded.

  1. Press the SET button. The HI value flashes on the display.
  2. Press the or button until the required maximum temperature is displayed.
  3. Press the SET button to confirm. The LO value flashes on the display.
  4. Press the or button until the required minimum temperature is displayed.
  5. Press the SET button to confirm and return to normal operation.
    • When the alarm sounds, press any button to turn it Off.
    Note: The appropriate icon on the display (HI or LO) continues to flash until the temperature returns to within the set range.
    • To permanently turn the alarm Off, follow the steps above but pressing the button when the HI and LO values flash on the display.

Technical Specification

Temperature range -50 to 200°C / -58 to 392°F
Temperature reading accuracy
  • ± 3°C/5.4°F between -50 200C/-58tv 40F
  • ± 1°C/1.8°F between -19.9 419.90C/-3.8 247.80F
  • ± 2°C/3.6°F between 120 2000C/248 3920F

Resolution| 0.1° over full range
Alarm Setting Resolution| 10 over full range
Temperature display refresh rate| 1 second
Display size| 19(h) x 48(w) mm
Battery| 1 x AAA 1.5v
Cable length| 1 meter
Probe size| 3.5 (0) x 125 (I) mm
Thermometer dimensions (h × w × d)| 116 x 78 x 28 mm
Ambient operating temperature| 0∼50 0 C / 32,4220F

Troubleshooting

If the appliance ceases to function correctly, press and hold the red RESET button (situated on the back of the appliance) using a pointed instrument.

Compliance

Dispose of depleted batteries in accordance with local regulations, within the EC there are nominated disposal points for batteries.
The WEEE logo on this product or its documentation indicates that the product must not be disposed of as household waste. To help prevent possible harm to human health and/or the environment, the product must be disposed of in an approved and environmentally safe recycling process. For further information on how to dispose of this product correctly, contact the product supplier, or the local authority responsible for waste disposal in your area.

HYGIPLAS parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international, independent, and federal authorities.
HYGIPLAS products have been approved to carry the following symbol:

UKCR CE

All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of HYGIPLAS.
Every effort is made to ensure all details are correct at the time of going to press, however, HYGIPLAS reserve the right to change specifications without notice.

UK 0845 146 2887 Fourth Way, Avonmouth, Bristol, BS11 8TB United Kingdom
Eire 42 North Point Business Park, New Mallow Road, Cork, Ireland
NL 040 — 2628080
FR 01 60 34 28 80
BE-NL 0800-29129
BE-FR 0800-29229
DE 0800 — 1860806
ES 901-100 133
PT [email protected]
AU 1300 225 960 15 Badgally Road, Campbelltown, 2560, NSW, Australia

DECLARATION OF CONFORMITY

Equipment Type| Insertion Thermometer
Insertion T-Shape Thermometer
Mini Fridge /Freezer  Thermometer
Oven Digital Cooking Thermometer
Multi-Purpose Stem Thermometer
Catertherm Thermometer
Digital Water Resistant Thermometer
---|---
Model| J229
F306
CB891
CE399
F338
GG748
GH628
Application of Council Directives(s)| ElectroMagnetic Compatibility (EMC) Directive
2014/30/EU
EN 61326-1:2013 
Restriction of Hazardous Substances Directive
(RoHS) 2015/863 amending Annex II to Directive
2011/65/EU
Producer Name| Hygiplas
Producer Address| Fourth Way,
Avonmouth,
Bristol,
BS11 8TB
United Kingdom| 42 North Point Business
Park
New Mallow Road
Cork
Ireland

I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).

Date 31 st May 2019
Signature ****
Full Name Ashley Hooper
Position Technical & Quality Manager

HYGIPLAS Logo F338_ML_130x210mm_v6_20210419

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HYGIPLAS User Manuals

Related Manuals