HYGIPLAS GG749 Infrared Thermometer User Manual

June 7, 2024
HYGIPLAS

HYGIPLAS - logo

Infrared Thermometer

HYGIPLAS GG749 Infrared Thermometer

Model
GG749/GL267

SAFETY TIPS

  • DO NOT submerge the unit in water
  • The product is not designed for use in medical evaluations. The product can only be used to measure food temperature.
  • Only qualified personnel should perform repairs not covered in this manual.

FEATURES

  • Ultra Low power consumption in shutdown mode
  • Backlit LCD display
  • Laser On/Off switch
  •  °C and °F selectable
  •  Temperature data storage

SPECIFICATION

Model GG749 :

Distance Spot Ratio: 12:1
Temperature Range -50°C to 400°C (-58°F to 752°F)
Accuracy ±3°C (±5°F) from -50°C to -30°C (-58°F to -22°F) ±2°C (±3°F) from

-30°C to 100°C (-22°F to 212°F) ±2% from 100°C to 400°C (212°F to 752°F)
Resolution| 0.1°C (0.1°F)
Response Time| 500ms
Auto Power Off| Automatically after approx 6 secs
Battery| 9V
Battery Life| 16hrs
Dimensions| 180(H) x 50(W) x 100(D)mm (7.08″x1.97″x3.94″)
Weight| 225g

Model GL267

Distance Spot Ratio: 8:1
Temperature Range -20°C to 320°C (-4°F to 605°F)
Accuracy ±2% of reading or ±2°C (±3°F) whichever is greater
Resolution 0.5°C (0.5°F)
Response Time 500ms
Auto Power Off Automatically after approx 6 secs
Battery 9V
Battery Life 16hrs
Dimensions 156(H) x 32(W) x 100(D)mm (6.14″x1.25″x3.94″)
Weight 135g

UNIT DIAGRAMS

1. Unit

HYGIPLAS GG749 Infrared Thermometer - UNIT DIAGRAMS
2. Battery cover

HYGIPLAS GG749 Infrared Thermometer - Battery cover

INSTALLATION

Battery

  1. The unit is supplied and powered by a 9V battery.
  2. When the battery is low, the battery symbol will appear.
  3. To change the 9V battery, pull open the battery cover, and replace it with a new one, and push back the cover to close.

OPERATION

  1. To measure a temperature. Point the unit at the target you want to measure, push the trigger and hold until the end of the shot.

  2. In SCAN mode, the LCD displays the current temperature in either °C or °F. To switch between °C
    or °F, use the button inside the battery cover (see diagram 2).

  3. The unit will HOLD the last reading for approx 6 seconds after the trigger is released, the word
    HOLD appears.

  4. Be sure to consider the target area inside the angle of vision on this instrument. The single spot of the laser is used for aiming only.

LCD Display

HYGIPLAS GG749 Infrared Thermometer - LCD Display

TECHIQUES OF INFRARED

  • The field of view (FOV) is the angle of vision at which the instrument operates, and is determined by the optics of the unit.
  • The FOV is the ratio of the distance from the target to the target diameter. The smaller the target, the closer you should be to it.
  •  When the target is small, it is important to bring the thermometer closer to the target to ensure that only the target is being measured, excluding the surroundings.

MAINTENANCE

  1. Cleaning the lens: Remove any loose particles using clean compressed air
  2. Carefully wipe the surface with a moist cotton swab. The swab may be moistened with water
  3. DO NOT use solvents to clean the lens

Compliance

Dispose of depleted batteries in accordance with local regulations, within the EC there are nominated disposal points for batteries.

The WEEE logo on this product or its documentation indicates that the product must not be disposed of as household waste. To help prevent possible harm to human health and/or the environment, the product must be disposed of in an approved and environmentally safe recycling process.  For further information on how to dispose of this product correctly, contact the product supplier, or the local authority responsible for waste disposal in your area.

HYGIPLAS parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international,  independent, and federal authorities.

HYGIPLAS products have been approved to carry the following symbol:

All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of HYGIPLAS.
Every effort is made to ensure all details are correct at the time of going to press, however, HYGIPLAS reserve the right to change specifications without notice.

DECLARATION OF CONFORMITY
• Conformiteitsverklaring

Equipment Type| Mini Infrared Thermometer
Infrared Thermometer
---|---
Model| GL267
GG749
Application of Council Directives(s)| ElectroMagnetic Compatibility (EMC) Directive 2014/30/EU
EN 55011 :2009 +A1:2010 Group 1, Class B
EN 61000-4-2:2009
EN 61000-4-3:2006 +A1:2008 +A2:2010
EN 61000-4-8:2010
Restriction of Hazardous Substances Directive
(RoHS) 2015/863 amending Annex II to Directive
2011/65/EU
Producer Name| Hygiplas
Producer Address| Fourth Way, Avonmouth,
Bristol, BS11 8TB United Kingdom| 42 North Point Business Park
New Mallow Road Cork Ireland

I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).

Date 4th  June 2019
Signature
Full Name Ashley Hooper
Position Technical & Quality Manager

UK| +44 (0)845 146 2887| Fourth Way, Avonmouth, Bristol, 8511 8TB United Kingdom
---|---|---
Eire| 42 North Point Business Park, New Mallow Road, Cork, Ireland
NL| 040 — 2628080|
FR| 01 60 34 28 80|
BE-NL| 0800-29129|
BE-FR| 0800-29229|
DE| 0800 — 1860806|
IT| N/A|
ES| 901-100 133|
PT| vendasOnisbets.pt|
AU| 1300 225 960| 15 Badgally Road, Campbelltown, 2560, NSW, Australia

HYGIPLAS - logo
GG749_GL267_ML_v3_20201210

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals