resideo E121S / E125S Braukmann Installation Guide

June 7, 2024
resideo

resideo E121S / E125S Braukmann Installation Guide
resideo E121S / E125S Braukmann

Safety Guidelines

  1. Follow the installation instructions.
  2. Use the appliance
    • according to its intended use
    • in good condition
    • with due regard to safety and risk of danger.
  3. Note that the appliance is exclusively for use in the applications detailed in these installation instructions (see 2 Technical Data). Any other use will not be considered to comply with requirements and would invalidate the warranty.
  4. Please take note that any assembly, commissioning, servicing and adjustment work may only be carried out by authorized persons.
  5. Immediately rectify any malfunctions which may influence safety.

Technical Data

E121S

Media

Medium:| Water
Operating temperatures
Max. operating temperature medium:| 150 °C
(not suitable for steam)
Pressure values
Nominal pressure:| 10 bar
Max. operating pressure:| 0.5 – 10 bar
Connections/Sizes
Connection sizes:| G3/8″ or G1/2″

E125S

Media

Medium:| Water or water-glycol mixture, quality according to VDI 2035 (up to 50 % glycol)
Operating temperatures
Max. operating temperature medium:| 150 °C*
Pressure values
Max. operating pressure:| 0.5 – 10 bar
Nominal pressure:| max. 18 bar
Connections/Sizes
Connection sizes:| G 3/8″ or G 1/2″

***** Not suitable for steam

Options

For Options visit homecomfort.resideo.com/europe

Assembly

Installation Guidelines
Install at the highest points of the system, as well as anywhere where air accumulations can form

  • Installation in the flow pipe on the pressure side of the pump is recommended
  • The valve cap should remain on the air vent in order to prevent functional disruption due to dirt particles that have entered from the outside
  • Therefore the air vent is drip free

Assembly instructions

  1. Blow out or rinse pipe line out well
    • Mount shut-off valve under the air vent
  2. enables maintenance without emptying the system
  3. The air vent must be installed vertically
  4. The lower part of the shut-off valve must be installed in a sufficiently large free cross-section of the pipe
  5. Sealing is produced by means of the O-rings (3/8″) or sealing’s (1/2″) at the housing floor

Commissioning

  1. Open knurled cap two rotations

Maintenance

In order to comply with EN 806-5, water fixtures must be inspected and serviced on an annual basis. As all maintenance work must be carried out by an installation company, it is recommended that a servicing contract should be taken out. In accordance with EN 806-5, the following measures must be taken:

Inspection
The air vent must be examined regularly, since malfunctions can occur due to dirt accumulation

Disposal
Observe the local requirements regarding correct waste recycling/disposal!

Accessories
For Accessories visit homecomfort.resideo.com/europe

Company Logo

Manufactured for and on behalf of Pittway Sàrl, Z.A., La Pièce 4, 1180 Rolle, Switzerland by its authorised representative Ademco 1 GmbH
For more information homecomfort.resideo.com/europe Ademco 1 GmbH, Hardhofweg 40, 74821 MOSBACH, GERMANY Phone: +49 6261 810 Fax: +49 6261 81309
© 2020 Resideo Technologies, Inc. All rights reserved. Subject to change. MU1H-13059GE23 R0420